Comparison of laser and traditional lancing devices for capillary blood sampling in patients with diabetes mellitus and high bleeding risk.
Park, Min Jeong; Hwang, Soon Young; Jang, Ahreum; Jang, Soo Yeon; Song, Eyun; Park, So Young; Lee, Da Young; Kim, Jaeyoung; Park, Byung Cheol; Yu, Ji Hee; Seo, Ji A; Choi, Kyung Mook; Baik, Sei Hyun; Yoo, Hye Jin; Kim, Nan Hee.
Afiliación
  • Park MJ; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Hwang SY; Department of Biostatistics, Korea University College of Medicine, Seoul, 08308, Korea.
  • Jang A; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Jang SY; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Song E; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Park SY; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Lee DY; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Kim J; Research Institute for Skin Imaging, Korea University College of Medicine, Seoul, Korea.
  • Park BC; LAMEDITECH, Seoul, Korea.
  • Yu JH; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Seo JA; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Choi KM; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Baik SH; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea.
  • Yoo HJ; Division of Endocrinology and Metabolism, Department of Internal Medicine, College of Medicine, Korea University, Seoul, Korea. deisy21@korea.ac.kr.
  • Kim NH; Division of Endocrinology and Metabolism, Department of Internal Medicine, Korea University Guro Hospital, Seoul, 152-050, Korea. deisy21@korea.ac.kr.
Lasers Med Sci ; 39(1): 170, 2024 Jul 03.
Article en En | MEDLINE | ID: mdl-38958779
ABSTRACT

PURPOSE:

Despite the importance of self-monitoring blood glucose (SMBG) for management of diabetes mellitus (DM), frequent blood sampling is discouraged by bleeding risk due to dual-antiplatelet agent therapy (DAPT) or thrombocytopenia.

METHODS:

We compared the bleeding time (BT) of sampling by using a laser-lancing-device (LMT-1000) and a conventional lancet in patients with DM and thrombocytopenia or patients undergoing DAPT. BT was measured using the Duke method, and pain and satisfaction scores were assessed using numeric rating scale (NRS) and visual analog scale (VAS). The consistency in the values of glucose and glycated-hemoglobin (HbA1c) sampled using the LMT-1000 or lancet were compared.

RESULTS:

The BT of sampling with the LMT-1000 was shorter than that with the lancet in patients with thrombocytopenia (60s vs. 85s, P = 0.024). The NRS was lower and the VAS was higher in laser-applied-sampling than lancet-applied sampling in the DAPT-user group (NRS 1 vs. 2, P = 0.010; VAS 7 vs. 6, P = 0.003), whereas the group with thrombocytopenia only showed improvement in the VAS score (8 vs. 7, P = 0.049). Glucose and HbA1c sampled by the LMT-1000 and lancet were significantly correlated in both the DAPT-user and the thrombocytopenia groups.

CONCLUSION:

The LMT-1000 can promote SMBG by shortening BT in subject with thrombocytopenia and by increasing satisfaction score, as well as by showing reliable glucose and HbA1c value.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Glucemia / Automonitorización de la Glucosa Sanguínea / Hemorragia / Rayos Láser Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Glucemia / Automonitorización de la Glucosa Sanguínea / Hemorragia / Rayos Láser Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Lasers Med Sci Asunto de la revista: BIOTECNOLOGIA / RADIOLOGIA Año: 2024 Tipo del documento: Article