Your browser doesn't support javascript.
loading
Transverse interlaminar ultrasound-guided C1-C2 puncture for the intrathecal administration of nusinersen in patients with spinal muscular atrophy.
Yuan, Qing; Cui, Xulei; Zhang, Jiao; Dai, Yi; Feng, Feng; Huang, Yuguang; Zhang, Shuyang.
Afiliación
  • Yuan Q; Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Cui X; Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Zhang J; Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Dai Y; Department of Neurology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Feng F; Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Huang Y; Department of Anesthesiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Zhang S; State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Muscle Nerve ; 2024 Jul 25.
Article en En | MEDLINE | ID: mdl-39049699
ABSTRACT
INTRODUCTION/

AIMS:

Severe spinal deformities and previous spinal orthopedic instrumentation may result in substantial technical challenges for nusinersen delivery through lumbar puncture in patients with spinal muscular atrophy (SMA). The aim of this paper was to review our experience with ultrasound-guided cervical puncture as an alternative approach for the intrathecal administration of nusinersen.

METHODS:

This was a retrospective medical record review of transverse interlaminar ultrasound-guided C1-C2 puncture for nusinersen delivery in SMA patients. The details of puncture, complications, and success rate of the procedure were summarized.

RESULTS:

There were four patients who received a total of 13 cervical punctures for nusinersen delivery. All procedures were technically successful with no major complications. Full doses of nusinersen were delivered intrathecally.

DISCUSSION:

Transverse interlaminar ultrasound-guided C1-C2 puncture is an alternative approach for administering nusinersen if lumbar puncture fails. The success of the technique requires a thorough preprocedural evaluation of cervical spine imaging, sound knowledge of the cervical sonoanatomy and careful manipulation of the needle.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Muscle Nerve Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Muscle Nerve Año: 2024 Tipo del documento: Article País de afiliación: China