Your browser doesn't support javascript.
loading
Theory and application of robust linear phase-shift algorithm for phase-shift deflectometry method.
Yang, Song; Zhu, Xianyong; Cao, Zhirui; Zhao, Jiali; Xiao, Xiong; Lv, Changchun; Du, Yang; Wang, Ruiqing; Wu, Peng; Wang, Zheyuan.
Afiliación
  • Yang S; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, Jilin, China.
  • Zhu X; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, Jilin, China. zhuxy@jlu.edu.cn.
  • Cao Z; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, Jilin, China.
  • Zhao J; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, Jilin, China.
  • Xiao X; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, Jilin, China.
  • Lv C; School of Mechanical and Aerospace Engineering, Jilin University, Changchun, 130025, Jilin, China.
  • Du Y; FAW-VOLKSWAGEN, Changchun, 130000, Jilin, China.
  • Wang R; The Second Hospital of Jinlin University, Changchun, 130041, Jilin, China.
  • Wu P; Changchun Baoze Technology Co., Ltd., Changchun, 130051, China.
  • Wang Z; The Internet Information Center of Tiexi, Siping, 136000, China.
Sci Rep ; 14(1): 18424, 2024 Aug 08.
Article en En | MEDLINE | ID: mdl-39117710
ABSTRACT
Based on the polynomial theory, the error propagation characteristics of the widely used N-step discrete Fourier transform (N-DFT) phase-shift algorithm were analyzed via theoretical analysis, under the effect of Gamma distortion and phase detuning. The results showed that the N-DFT algorithm could not simultaneously suppress both types of error. A robust linear phase-shift (RLPS) algorithm was designed, the performance of the RLPS and 8-DFT algorithms in terms of spectral response, detuning robustness, and G S / N was briefly analysis by Manuel Servin method. The Simulation analysis and comparison of the results show that the RLPS algorithm could suppress both types of error simultaneously, which exhibited better stability and accuracy than N-DFT and exponential algorithms, particularly in gradient measurement stability, peak-to-valley (PV) and root-mean-square (RMS) error suppression. Moreover, a physical experiment apparatus was built to test unidirectionally inclined plane mirror and concave mirror using the RLPS, N-DFT, and exponential algorithms. The results showed that the RLPS algorithm could significantly improve the measurement stability and accuracy in the presence of detuning and without screen Gamma calibration.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Sci Rep Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Revista: Sci Rep Año: 2024 Tipo del documento: Article País de afiliación: China