Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J. med. virol ; 94(1): 178-185, 2022. tab, graf
Artigo em Inglês | Coleciona SUS - BR, SES-SP, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: biblio-1393242

RESUMO

Many aspects of the humoral immune response to severe acute respiratory syn-drome coronavirus 2 (SARS­CoV­2), such as its role in protection after natural in-fection, are still unclear. We evaluated IgA and IgG response to spike subunits 1 and2 (S1 and S2) and Nucleocapsid proteins of SARS­COV­2 in serum samples of 109volunteers with viral RNA detected or seroconversion with different clinical evolu-tion (asymptomatic, mild, moderate, and severe coronavirus disease 2019), using theViraChip®Test Kit. We observed that the quantification of antibodies to all antigenshad a positive correlation to disease severity, which was strongly associated with thepresence of comorbidities. Seroreversion was not uncommon even during the short(median of 77 days) observation, occurring in 15% of mild­asymptomatic cases at amedian of 55 days for IgG and 46 days for IgA. The time to reach the maximalantibody response did not differ significantly among recovered and deceased vo-lunteers. Our study illustrated the dynamic of anti­S1, anti­N, and anti­S2 IgA andIgG antibodies, and suggests that high production of IgG and IgA does not guaranteeprotection to disease severity and that functional responses that have been studiedby other groups, such as antibody avidity, need further attention. (AU)


Assuntos
Nucleocapsídeo , Análise Serial de Proteínas , Glicoproteína da Espícula de Coronavírus , SARS-CoV-2 , COVID-19
2.
J Bras Patol Med Lab. ; 57: 1-10, 20 jul. 2021. ilus, tab
Artigo em Português | SES-SP, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: biblio-1393122

RESUMO

Introdução: Em função da urgência e demanda de uma resposta à pandemia do novo coronavírus (Covid-19), vários testes de detecção de anticorpos para a síndrome respiratória aguda grave do coronavírus 2 (Sars-CoV-2) têm sido desenvolvidos. Objetivo: Este estudo teve como objetivo avaliar o desempenho do teste rápido utilizado em um inquérito epidemiológico para Sars-CoV-2 em comparação com outros ensaios sorológicos. Métodos: Foram avaliadas 86 amostras de soro em três ensaios sorológicos: um imunoensaio de fluxo lateral ­ Wondfo Sars-CoV-2 Antibody Test (TRW) ­ e dois imunoensaios de quimioluminescência: Elecsys anti-Sars-CoV-2 (ECLIA) e Sars-CoV-2 IgG (CMIA-IgG). Resultados: As sensibilidades diagnósticas estimadas dos testes sorológicos na avaliação dessas amostras foram: TRW 59% [95% intervalo de confiança (IC) 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) e CMIA-IgG 61,5% (47,1%-73%). Enquanto isso, a especificidade diagnóstica estimada para TRW foi 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) e CMIA-IgG 76,6% (74%-95,5%). Os valores de sensibilidade e especificidade foram inferiores aos afirmados pelos fabricantes. Embora 16,2% (14/86) dos resultados tenham sido discordantes entre os três ensaios serológicos para Sars-CoV-2, o grau de concordância pelo índice Kappa foi adequado: TRW/CMIA-IgG [0,757 (95% IC 0,615-0,899)], TRW/ECLIA [0,715 (0,565-0,864)] e ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusão: O teste sorológico pode ser uma ferramenta diagnóstica útil, o que reforça sua avaliação criteriosa, bem como o momento correto de sua utilização. (AU)


Introduction: Due to urgency and demand of a response to the Covid-19 pandemic, numerous Sars-CoV-2 immunoassays have been rapidly developed. Objective: This study aimed at assessing the performance of rapid Sars-CoV-2 antibody test in comparison to high-throughput serological assays. Methods: A total of 86 serum samples were evaluated in the three assays: a lateral flow immunoassay ­ Wondfo Sars-CoV-2 Antibody Test (WRT) ­ and two chemiluminescence immunoassays: Elecsys Anti-Sars-CoV-2 (ECLIA), and Sars-CoV-2 IgG (CMIA-IgG). Results: The estimated diagnostic sensitivities of serological tests in the evaluation of serum samples from the epidemiological survey were: WRT 59.0% [95% confidence interval (CI) 43.4%-72.9%], ECLIA 66.7% (51%-79.4%), and CMIA-IgG 61.5% (47.1%-73%). Meanwhile, the estimated diagnostic specificity was for WRT 78.7% (95% CI 65.1%-88%), ECLIA 72.3% (58.2%-83.1%), and CMIA-IgG 76.6% (74%-95.5%). The sensitivity and specificity values were lower than manufacturers' claimed. Although 16.2% (14/86) of serological results were discordant among the three Sars-CoV-2 serological assays, the degree of agreement by the kappa index was adequate: WRT/CMIA-IgG [0.757 (95% CI 0.615-0.899)], WRT/ECLIA [0.715 (0.565-0.864)], and ECLIA/CMIA-IgG [0.858 (0.748-0.968)]. Conclusion: The serological testing may be a useful diagnostic tool, which reinforces its careful evaluation, and, as well as the correct time to use it. (AU)


Assuntos
Sorologia , Imunoensaio , Infecções por Coronavirus , Testes Imediatos , Betacoronavirus , SARS-CoV-2 , Anticorpos
3.
J. Bras. Patol. Med. Lab. (Online) ; 57: e4252021, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1350880

RESUMO

ABSTRACT Introduction: Due to urgency and demand of a response to the Covid-19 pandemic, numerous Sars-CoV-2 immunoassays have been rapidly developed. Objective: This study aimed at assessing the performance of rapid Sars-CoV-2 antibody test in comparison to high-throughput serological assays. Methods: A total of 86 serum samples were evaluated in the three assays: a lateral flow immunoassay - Wondfo Sars-CoV-2 Antibody Test (WRT) - and two chemiluminescence immunoassays: Elecsys Anti-Sars-CoV-2 (ECLIA), and Sars-CoV-2 IgG (CMIA-IgG). Results: The estimated diagnostic sensitivities of serological tests in the evaluation of serum samples from the epidemiological survey were: WRT 59% [95% confidence interval (CI) 43.4%-72.9%], ECLIA 66.7% (51%-79.4%), and CMIA-IgG 61.5% (47.1%-73%). Meanwhile, the estimated diagnostic specificity was for WRT 78.7% (95% CI 65.1%-88%), ECLIA 72.3% (58.2%-83.1%), and CMIA-IgG 76.6% (74%-95.5%). The sensitivity and specificity values were lower than manufacturers' claimed. Although 16.2% (14/86) of serological results were discordant among the three Sars-CoV-2 serological assays, the degree of agreement by the kappa index was adequate: WRT/CMIA-IgG [0.757 (95% CI 0.615-0.899)], WRT/ECLIA [0.715 (0.565-0.864)], and ECLIA/CMIA-IgG [0.858 (0.748-0.968)]. Conclusion: The serological testing may be a useful diagnostic tool, which reinforces its careful evaluation, and, as well as the correct time to use it.


RESUMEN Introducción: Debido a la urgencia y la demanda de una respuesta a la pandemia de Covid-19, se han desarrollado rápidamente numerosos inmunoensayos del Sars-CoV-2. Objetivo: Este estudio tuvo como objetivo evaluar el rendimiento de la prueba rápida de anticuerpos contra el Sars-CoV-2 en comparación con los ensayos serológicos de alto rendimiento. Métodos: Se evaluaron un total de 86 muestras de suero en los tres ensayos: un inmunoensayo de flujo lateral - Wondfo Sars-CoV-2 Antibody Test (TRW) - y dos inmunoensayos de quimioluminiscencia: Elecsys Anti-Sars-CoV-2 (ECLIA) y Sars-CoV-2 IgG (CMIA-IgG). Resultados: Las sensibilidades diagnósticas estimadas de las pruebas serológicas en la evaluación de muestras de suero de la encuesta epidemiológica fueron: WRT 59% [intervalo de confianza (IC) del 95%: 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) y CMIA-IgG 61,5% (47,1%-73%). Mientras tanto, la especificidad diagnóstica estimada fue para WRT 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) y CMIA-IgG 76,6% (74%-95,5%). Los valores de sensibilidad y especificidad fueron más bajos que los declarados por los fabricantes. Aunque el 16,2% (14/86) de los resultados fueron discordantes entre los tres ensayos serológicos del Sars-CoV-2, el grado de concordancia del índice kappa fue adecuado: WRT/CMIA-IgG [0,757 (IC del 95%: 0,615-0,899)], WRT/ECLIA [0,715 (0,565-0,864)] y ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusión: La prueba serológica puede ser una herramienta diagnóstica útil, lo que refuerza su evaluación cuidadosa, así como el momento adecuado para usarla.


RESUMO Introdução: Em função da urgência e demanda de uma resposta à pandemia do novo coronavírus (Covid-19), vários testes de detecção de anticorpos para a síndrome respiratória aguda grave do coronavírus 2 (Sars-CoV-2) têm sido desenvolvidos. Objetivo: Este estudo teve como objetivo avaliar o desempenho do teste rápido utilizado em um inquérito epidemiológico para Sars-CoV-2 em comparação com outros ensaios sorológicos. Métodos: Foram avaliadas 86 amostras de soro em três ensaios sorológicos: um imunoensaio de fluxo lateral - Wondfo Sars-CoV-2 Antibody Test (TRW) - e dois imunoensaios de quimioluminescência: Elecsys anti-Sars-CoV-2 (ECLIA) e Sars-CoV-2 IgG (CMIA-IgG). Resultados: As sensibilidades diagnósticas estimadas dos testes sorológicos na avaliação dessas amostras foram: TRW 59% [95% intervalo de confiança (IC) 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) e CMIA-IgG 61,5% (47,1%-73%). Enquanto isso, a especificidade diagnóstica estimada para TRW foi 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) e CMIA-IgG 76,6% (74%-95,5%). Os valores de sensibilidade e especificidade foram inferiores aos afirmados pelos fabricantes. Embora 16,2% (14/86) dos resultados tenham sido discordantes entre os três ensaios serológicos para Sars-CoV-2, o grau de concordância pelo índice Kappa foi adequado: TRW/CMIA-IgG [0,757 (95% IC 0,615-0,899)], TRW/ECLIA [0,715 (0,565-0,864)] e ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusão: O teste sorológico pode ser uma ferramenta diagnóstica útil, o que reforça sua avaliação criteriosa, bem como o momento correto de sua utilização.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA