Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | SES-SP, CONASS, SESSP-IDPCPROD, SES-SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
2.
Am. j. cardiol ; 125(9): 1369-1377, May., 2020. graf.
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1099637

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)


Assuntos
Substituição da Valva Aórtica Transcateter , Valva Aórtica
3.
Can J Cardiol ; 36(5): 747-755, May., 2020. tab., graf.
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1102329

RESUMO

BACKGROUND: We evaluated the association of pulse pressure (PP) and different antiplatelet regimes with clinical and safety outcomes in an all-comers percutaneous coronary intervention (PCI) population. METHODS: In this analysis of GLOBAL LEADERS (n = 15,936) we compared the experimental therapy of 23 months of ticagrelor after 1 month of dual-antiplatelet therapy (DAPT) vs standard DAPT for 12 months followed by aspirin monotherapy in subjects who underwent PCI and were divided into 2 groups according to the median PP (60 mm Hg). The primary end point (all-cause death or new Q-wave myocardial infarction) and the composite end points: patient-oriented composite end points (POCE), Bleeding Academic Research Consortium (BARC) 3 or 5, and net adverse clinical events (NACE) were evaluated. RESULTS: At 2 years, subjects in the high-PP group (n = 7971) had similar rates of the primary end point (4.3% vs 3.9%; P = 0.058), POCE (14.9% vs 12.7%; P = 0.051), and BARC 3 or 5 (2.5% vs 1.7%; P = 0.355) and higher rates of NACE (16.4% vs 13.7%; P = 0.037) compared with the low-PP group (n = 7965). Among patients with PP < 60 mm Hg, the primary end point (3.4% vs 4.4%, adjusted hazard ratio [aHR] 0.77, 95% confidence interval [CI] 0.61-0.96), POCE (11.8% vs 13.5%, aHR 0.86, 95% CI 0.76-0.98), NACE (12.8% vs 14.7%, aHR 0.85, 95% CI 0.76-0.96), and BARC 3 or 5 (1.4% vs 2.1%, aHR 0.69, 95% CI 0.49-0.97) were lower with ticagrelor monotherapy compared with DAPT. The only significant interaction was for BARC 3 or 5 (P = 0.008). CONCLUSIONS: After contemporary PCI, subjects with high PP levels experienced high rates of NACE at 2 years. In those with low PP, ticagrelor monotherapy led to a lower risk of bleeding events compared with standard DAPT.


Assuntos
Humanos , Pessoa de Meia-Idade , Idoso , Inibidores da Agregação Plaquetária/uso terapêutico , Intervenção Coronária Percutânea
4.
Am. j. cardiol ; 124(12): 1833-1840, dez., 2019. tab., graf.
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1050065

RESUMO

Abstract: Q-wave myocardial infarction (QWMI) comprises 2 entities. First, a clinically evident MI, which can occur spontaneously or be related to a coronary procedure. Second, silent MI which is incidentally detected on serial electrocardiographic (ECG) assessment. The prevalence of silent MI after percutaneous coronary intervention (PCI) in the drug-eluting stent era has not been fully investigated. The GLOBAL LEADERS is an all-comers multicenter trial which randomized 15,991 patients who underwent PCI to 2 antiplatelet treatment strategies. The primary end point was a composite of all-cause death or nonfatal new QWMI at 2-years follow-up. ECGs were collected at discharge, 3-month and 2-year visits, and analyzed by an independent ECG core laboratory following the Minnesota code. All new QWMI were further reviewed by a blinded independent cardiologist to identify a potential clinical correlate by reviewing clinical information. Of 15,968 participants, ECG information was complete in 14,829 (92.9%) at 2 years. A new QWMI was confirmed in 186 (1.16%) patients. Transient new Q-waves were observed in 28.5% (53 of 186) of them during the follow-up. The majority of new QWMI (78%, 146 of 186) were classified as silent MI due to the absence of a clinical correlate. Silent MI accounted for 22.1% (146 of 660) of all MI events. The prevalence of silent MI did not differ significantly between treatment strategies (experimental vs reference: 0.88% vs 0.98%, p = 0.5027). In conclusion, we document the prevalence of silent MI in an all-comers population undergoing PCI in this large-scale randomized trial. (AU)


Assuntos
Stents , Intervenção Coronária Percutânea , Infarto do Miocárdio
5.
JACC cardiovasc. interv ; 12(5): 433-443, Mar. 2019. tabela, gráfico
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1024526

RESUMO

Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)


Assuntos
Humanos , Substituição da Valva Aórtica Transcateter
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA