Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | SES-SP, CONASS, SESSP-IDPCPROD, SES-SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
2.
Clin. infect. dis ; 73(11): 3750-e:3758, Dec. 2021. graf, tab
Artigo em Inglês | CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1353336

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE (CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite , Substituição da Valva Aórtica Transcateter
3.
Circulation ; 142(15): 1497-1499, Oct. 2020. graf
Artigo em Inglês | SES-SP, CONASS, SESSP-IDPCPROD, SES-SP | ID: biblio-1148174
4.
Circ. cardiovasc. interv ; 12(11): 1-8, nov., 2019. ilus., graf., tab.
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1049984

RESUMO

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field. (AU)


Assuntos
Sistema de Registros , Incidência , Endocardite , Substituição da Valva Aórtica Transcateter
5.
JACC cardiovasc. interv ; 12(5): 433-443, Mar. 2019. tabela, gráfico
Artigo em Inglês | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1024526

RESUMO

Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)


Assuntos
Humanos , Substituição da Valva Aórtica Transcateter
6.
Arch. cardiol. Méx ; 85(2): 96-104, abr.-jun. 2015. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-754931

RESUMO

Objetivo: El sistema de atención en red por infarto con elevación del segmento ST «Codi Infart¼ se implementó en Cataluña (España) en junio de 2009. El objetivo del estudio fue evaluar el beneficio de la instauración del Codi Infart para las mujeres atendidas en nuestra institución. Método: Las mujeres referidas para angioplastia primaria se dividieron en 2 grupos de acuerdo con el Codi Infart: grupo no-Codi Infart (enero de 2003 a mayo de 2009) y grupo Codi Infart (junio de 2009 a diciembre de 2012); y se compararon lugar de procedencia, periodos, tratamientos recibidos y tasa de eventos cardiovasculares mayores definida como muerte por todas las causas, reinfarto o accidente cerebrovascular durante el ingreso, a 30 y 180 días. Resultados: De una población total de 2,426 pacientes, 501 (20.7%) eran mujeres. De ellas, 186 mujeres (2,09 casos/mes) pertenecían al grupo no-Codi Infart y 315 mujeres (10,16 casos/mes) al grupo Codi Infart. El porcentaje de mujeres atendidas aumentó desde la introducción del Codi Infart(22.2% vs. 18.5%, p = 0.028). Además, inicialmente el grupo Codi Infart presentó mayor porcentaje de mujeres atendidas fuera de nuestra institución (84.1% vs. 16.7%, p < 0.001), y menores tiempos totales de isquemia (220 [155-380] vs. 272 [196-456], p = 0.003), pero no se detectaron diferencias en eventos cardiovasculares mayores a 180 días (14.2% vs. 15.6%, p = 0.692). Conclusiones: La instauración del Codi Infart permitió aumentar de manera notable la tasa y el porcentaje de mujeres con infarto de miocardio con elevación del segmento ST tratadas mediante angioplastia primaria y reducir los tiempos totales de isquemia.


Objective: The ST-segment elevation myocardial infarction network "Codi Infart" was implemented in Catalonia (Spain) in June 2009. The objective of this study was to evaluate the impact of the implementation of the Codi Infart on women. Method: Women referred for primary percutaneous coronary intervention, were divided into two groups according to Codi Infart: Non-Codi Infart group (January 2003 to May 2009) and Codi Infart group (June 2009 to December 2012). Place of first medical contact, time intervals in diagnosis and treatment, treatments received and rate of major cardiovascular adverse events defined as all-cause death, reinfarction or stroke in-hospital, at 30 and 180 days were compared. Results: From a total population of 2,426 patients, 501 (20.7%) were women. One-hundred eighty-six women (2.09 cases/month) belonged to Non-Codi Infart group and 315 women (10.16 cases/month) to Codi Infart group. The percentage of women attended increased since the introduction of CI (22.2% vs. 18.5%, P = .028). In addition, the Codi Infart group had a higher percentage of women initially attended outside our institution (84.1% vs. 16.7%, P < .001), and lower total ischemia time (220 [155-380] vs. 272 [196-456], P = .003). However, no differences in 180-day major cardiovascular adverse events were detected (14.2% vs. 15.6%, P = .692). Conclusions: The implementation of the major cardiovascular adverse events allowed to increase the rate and the percentage of women with ST-segment elevation myocardial infarction treated with primary percutaneous coronary intervention and reducing total ischemic time.


Assuntos
Idoso , Feminino , Humanos , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea , Atenção à Saúde/organização & administração , Estudos Prospectivos , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA