Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Dement. neuropsychol ; 18: e20230089, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1564440

RESUMO

ABSTRACT Active aging is based on four pillars: health, safety, participation, and lifelong learning. These pillars help individuals improve their quality of life throughout the aging process. Objective: To analyze the effectiveness of the Active Aging Program; identify the sociodemographic profile of the participants; identify prevalent diseases in the initial evaluation; and assess the results of the program after one year of follow-up. Methods: This is a quantitative, cross-sectional, exploratory, desk research, and descriptive study. Data from 545 employees of University of São Paulo participating in the Active Aging Program of the University Teaching Hospital of the University of São Paulo (HU-USP) between 2015 and 2018 were analyzed using the Minitab Program. For data analysis, Pearson's chi-square test was used to determine the association between Groups A and B. For continuous measures, the paired t-test was used to verify differences in means, adopting a 95% confidence interval and significance level of 0.05. Results: Statistically significant correlations were found when crossing sex with smoking; sex with triglycerides; age with risk factors for cardiovascular diseases, being the age group 40-59 statistically more significant; physical activity with risk factors for cardiovascular diseases; and body mass index at program entry with the one-year result. Conclusion: The study expanded knowledge about risk factors for cardiovascular diseases and provided important information for the continuity of the program.


RESUMO O envelhecimento ativo se apoia em quatro pilares: saúde, segurança, participação e aprendizagem ao longo da vida. Esses pilares auxiliam os indivíduos na qualidade de vida ao longo do processo de envelhecimento. Objetivo: Analisar a efetividade do Programa Envelhecimento Ativo; identificar o perfil sociodemográfico dos participantes; identificar patologias predominantes na avaliação inicial; e verificar os resultados do programa após um ano de acompanhamento. Métodos: Trata-se de pesquisa quantitativa, de caráter transversal, exploratória, documentária e descritiva. Foram analisados os dados de 545 funcionários da Universidade de São Paulo que participaram do Programa do Envelhecimento Ativo do Hospital Universitário da Universidade de São Paulo (HU-USP) no período de 2015 a 2018. Os dados foram analisados pelo Programa Minitab. Na análise de dados, usou-se o Qui-quadrado para testar a associação entre os grupos. Já para medida contínua, utilizou-se o Teste T Pareado, para verificar se as médias eram diferentes. Nas análises, foi usado um período de confiabilidade de 95% e nível de relevância de 0,05. Resultados: Foram encontradas correlações estatisticamente expressivas no cruzamento de sexo com tabagismo; sexo com triglicérides; idade com fatores de risco para doenças cardiovasculares sendo que a faixa etária de 40-59 foi estatisticamente mais significativa; atividade física com prevalência de fatores de riscos para doenças cardiovasculares; e índice de massa corpórea inicial com o resultado após um ano. Conclusão: A pesquisa ampliou o conhecimento a respeito dos fatores de risco para doenças cardiovasculares e forneceu informações importantes para a continuidade do programa.

2.
Acta Paul. Enferm. (Online) ; 36: eAPE00461, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS, BDENF | ID: biblio-1419856

RESUMO

Resumo Objetivo Comparar o número de acertos dos estudantes na avaliação da dilatação cervical em simuladores de dilatação com e sem o uso de uma validação visual direta. Métodos Estudo transversal com 40 alunos de graduação em Obstetrícia de uma Universidade Pública de São Paulo, que avaliaram as dilatações cervicais em simuladores de dilatação às cegas, em três etapas: na primeira, estimaram as dilatações nos simuladores, na segunda, compararam sequencialmente os achados nos simuladores com uma ferramenta de validação visual direta usando a mão dominante e depois a mão não dominante, e na terceira etapa, compararam simultaneamente as estimativas encontradas nos simuladores com a validação visual direta com a mão dominante e não dominante. O desfecho foi o acerto da dilatação cervical nos simuladores de dilatação ou não acerto, com valor de p ≤ 0,05 considerado estatisticamente significativo. Resultados Foram analisadas 240 avaliações e computados os acertos dos estudantes relacionados a avaliação da dilatação cervical dos simuladores. Houve aumento da taxa de acerto de 47,1% com o uso da validação visual direta (OR= 4,689; IC95%: 2,601-8,452; p<0,001). Conclusão O uso de uma validação visual direta aumenta a probabilidade de acertos dos alunos na avaliação da dilatação cervical em simuladores de dilatação.


Resumen Objetivo Comparar el número de aciertos de los estudiantes en la evaluación de la dilatación cervical en simuladores de dilatación con y sin uso de una validación visual directa. Métodos Estudio transversal con 40 alumnos de la carrera de Obstetricia de una universidad pública de São Paulo, quienes evaluaron las dilataciones cervicales en simuladores de dilatación a ciegas, en tres etapas: en la primera, estimaron las dilataciones en los simuladores; en la segunda, compararon secuencialmente los resultados en los simuladores con una herramienta de validación visual directa usando la mano dominante y después la mano no dominante; y en la tercera etapa, compararon simultáneamente las estimativas encontradas en los simuladores con la validación visual directa con la mano dominante y no dominante. El criterio de valoración fue el acierto de la dilatación cervical en los simuladores de dilatación o el no acierto, con un valor de p ≤ 0,05 considerado estadísticamente significativo. Resultados Se analizaron 240 evaluaciones y se computaron los aciertos de los estudiantes relacionados con la evaluación de la dilatación cervical de los simuladores. Hubo un aumento del índice de acierto del 47,1 % con el uso de la validación visual directa (OR= 4,689; IC 95 %: 2,601-8,452; p<0,001). Conclusión El uso de una validación visual directa aumenta la probabilidad de aciertos de los alumnos en la evaluación de la dilatación cervical en simuladores de dilatación.


Abstract Objective To compare the number of hits of students in cervical dilation assessment in dilation simulators with and without the use of direct visual validation. Methods This is a cross-sectional study with 40 undergraduate obstetrics students from a public university in São Paulo, who assessed cervical dilatations in blind dilatation simulators, in three stages: in the first, they estimated dilations in the simulators; in the second, they sequentially compared the findings in simulators with a direct visual validation tool using the dominant hand and then the non-dominant hand; and in the third step, they simultaneously compared the estimates found in simulators with direct visual validation with the dominant and non-dominant hands. The outcome was the success of cervical dilation in dilation simulators or not, with a p-value ≤ 0.05 considered statistically significant. Results We analyzed 240 assessments and computed the hits of students related to cervical dilatation assessment of simulators. There was an increase in the hit rate of 47.1% with the use of direct visual validation (OR= 4.689; 95%CI: 2.601-8.452; p<0.001). Conclusion The use of direct visual validation increases the probability of hits by students in cervical dilation assessment in dilation simulators.

3.
Rev. saúde pública ; 46(6): 1023-1029, Dez. 2012. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-667615

RESUMO

OBJETIVO: Analisar a frequência e os fatores maternos e neonatais associados ao mecônio no líquido amniótico no parto. MÉTODOS: Estudo transversal com 2.441 nascimentos em um centro de parto normal hospitalar em São Paulo, SP, em março e abril de 2005. A associação entre mecônio no líquido amniótico e as variáveis independentes (idade materna, paridade, ter ou não cesariana prévia, idade gestacional, antecedentes obstétricos, uso de ocitocina no trabalho de parto, dilatação cervical na admissão, tipo do parto atual, peso do RN, índice de Apgar de 1º e 5º minutos de vida) foi expressa como razão de prevalência. RESULTADOS: Verificou-se mecônio no líquido amniótico em 11,9% dos partos; 68,2% desses foram normais e 38,8%, cesarianas. O mecônio esteve associado a: primiparidade (RP = 1,49; IC95% 1,29;1,73), idade gestacional ≥ 41 semanas (RP = 5,05; IC95% 1,93;13,25), ocitocina no parto (RP = 1,83, IC95% 1,60;2,10), cesariana (RP = 2,65; IC95% 2,17;3,24) e índice de Apgar < 7 no 5º minuto (RP = 2,96, IC95% 2,94;2,99). A mortalidade neonatal foi 1,6/1.000 nascidos vivos; mecônio no líquido amniótico foi encontrado em 50% das mortes neonatais e associado a maiores taxas de partos cirúrgicos. CONCLUSÕES: Emprego de ocitocina, piores condições do recém-nascido logo após o parto e aumento de taxas de cesariana foram fatores associados ao mecônio. A utilização rotineira de ocitocina no intraparto poderia ser revista por sua associação com mecônio no líquido amniótico.


OBJECTIVE: To identify the frequency and maternal and neonatal factors associated with meconium-stained amniotic fluid at birth. METHODS: Cross-sectional study carried out with 2,441 births at an in-hospital birth center in the city of São Paulo (Southeastern Brazil) in March and April, 2005. The association between meconium-stained amniotic fluid and the independent variables (maternal age, parity, previous c-section or not, gestational age, obstetric history, oxytocin use in the labor, cervical dilation at admission, mode of current delivery, newborn weight, Apgar score at the 1st and 5th minute) was expressed as prevalence ratio (PR). RESULTS: Meconium-stained amniotic fluid was verified in 11.9% of the births; 68.2% of these were normal births and 38.8% c-sections. Meconium was associated with: primiparity (PR=1.49, 95%CI 1.29; 1.73), gestational age ≥ 41 weeks (PR = 5.05, 95%CI 1.93;13.25), oxytocin in labor (PR = 1.83, 95%CI 1.60; 2.10), c- section (PR = 2.65, 95%CI 2.17; 3.24) and Apgar scores < 7 at the 5th minute (PR = 2.96, 95%CI 2,94;2,99). Neonatal mortality was 1.6/1,000 live births. Meconium-stained amniotic fluid was found in 50% of neonatal deaths and it was associated with higher rates of surgical deliveries. CONCLUSIONS: Oxytocin use, worse conditions of the newborn after the delivery and increased c-section rates were factors associated with meconium-stained amniotic fluid. Routine use of oxytocin in the intrapartum period could be evaluated due to its association with meconium-stained amniotic fluid.


OBJETIVO: Analizar la frecuencia y los factores maternos y neonatales asociados al meconio en el líquido amniótico en el parto. MÉTODOS: Estudio transversal con 2.441 nacimientos en un centro de parto normal hospitalario en Sao Paulo, SP, en marzo y abril de 2005. La asociación entre meconio en el líquido amniótico y las variables independientes (edad materna, paridad, tener o no cesárea previa, edad de gestación, antecedentes obstétricos, uso de ocitocina en el trabajo de parto, dilatación cervical en la admisión, tipo de parto actual, peso del RN, índice de Apgar de 1º y 5º minutos de vida) fue expresada como el cociente de prevalencia. RESULTADOS: Se verificó meconio en el líquido amniótico en 11,9% de los partos; 68,2% de estos fueron normales y 38,8%, con cesárea. El meconio estuvo asociado a: primiparidad (RP = 1,49; IC95% 1,29;1,73), edad de gestación ≥ 41 semanas (RP = 5,05; IC95% 1,93;13,25), ocitocina en el parto (RP = 1,83, IC95% 1,60;2,10), cesárea (RP = 2,65; IC95% 2,17;3,24) e índice de Apgar < 7 no 5º minuto (RP = 2,96, IC95% 2,94;2,99). La mortalidad neonatal fue 1.6/1.000 nacidos vivos; meconio en el líquido amniótico fue encontrado en 50% de las muertes neonatales y asociado a mayores tasas de partos quirúrgicos. CONCLUSIONES: Empleo de ocitocina, peores condiciones del recién-nacido posterior al parto y aumento de tasas de cesárea fueron factores asociados al meconio. La utilización rutinaria de ocitocina en el intraparto podría ser revisada por su asociación con meconio en el líquido amniótico.


Assuntos
Feminino , Humanos , Recém-Nascido , Gravidez , Líquido Amniótico , Síndrome de Aspiração de Mecônio/epidemiologia , Complicações do Trabalho de Parto/epidemiologia , Índice de Apgar , Peso ao Nascer , Brasil/epidemiologia , Cesárea/estatística & dados numéricos , Estudos Transversais , Parto Obstétrico/estatística & dados numéricos , Idade Gestacional , Mortalidade Infantil , Idade Materna , Síndrome de Aspiração de Mecônio/etiologia , Resultado da Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA