RESUMO
OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.
Assuntos
Marca-Passo ArtificialRESUMO
BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. AIMS: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. METHODS: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. RESULTS: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). CONCLUSIONS: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.
Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , HemodinâmicaRESUMO
Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)
Assuntos
Substituição da Valva Aórtica Transcateter , Valva AórticaRESUMO
Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)
Assuntos
Humanos , Substituição da Valva Aórtica TranscateterRESUMO
Aims: We describe the first-in-human experience with a novel cerebral embolic protection device used duringtranscatheter aortic valve implantation (TAVI). One current challenge of TAVI is the reduction of proceduralstroke. Procedural mobilisation of debris is a known source of cerebral embolisation. Mechanicalprotection by transient filtration of cerebral blood flow might reduce the embolic burden during TAVI. Weaimed to evaluate the feasibility and safety of the Claret CE Pro cerebral protection device in patientsundergoing TAVI.Methods and results: Patients scheduled for TAVI were prospectively enrolled at three centres. The ClaretCE Pro (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device was placed via the right radial/brachial artery prior to TAVI and was removed after the procedure. The primary endpoint was technical successrate. Secondary endpoints encompassed procedural and 30-day stroke rates, as well as device-related complications.Deployment of the Claret CE Pro cerebral protection device was intended for use in 40 patients,35 devices were implanted into the aortic arch. Technical success rate with delivery of the proximal and distalfilter was 60% for the first generation device and 87% for the second-generation device. Delivery times for thefirst-generation device were 12.4±12.1 minutes and 4.4±2.5 minutes for the second-generation device (p<0.05).The quantity of contrast used related to the Claret CE Pro System was 19.6±3.8 ml. Captured debris was documentedin at least 19 of 35 implanted devices (54.3%). No procedural transient ischaemic attacks, minor strokesor major strokes occurred. Thirty-day follow-up showed one minor stroke occurring 30 days after the procedure,and two major strokes both occurring well after the patient had completed TAVI.Conclusions: The use of the Claret CE Pro system is feasible and safe.