Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Arq. bras. oftalmol ; Arq. bras. oftalmol;88(2): e2023, 2025. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1574013

RESUMO

ABSTRACT Purpose: To compare the outcomes of intravitreal dexamethasone implant used as either an adjuvant or a switching therapy for diabetic macular edema in patients with poor anatomic response after three consecutive monthly injections of ranibizumab. Methods: This retrospective study included patients with diabetic macular edema who received three consecutive doses of ranibizumab as initial therapy and demonstrated poor response. A single dose of intravitreal de xamethasone implant was administered to these patients. The patients were divided into two groups according to the treatment modalities: the adjuvant therapy group, consisting of patients who continued treatment with ranibizumab injection after receiving intravitreal dexamethasone implant, and the switch therapy group, consisting of patients who were switched from ranibizumab treatment to intravitreal dexamethasone implant as needed. The main outcome measurements were best corrected visual acuity and central retinal thickness at baseline and at 3, 6, 9, and 12 months of follow-up. Results: In this study that included 64 eyes of 64 patients, the best corrected visual acuity and central retinal thickness values did not significantly differ between the groups at baseline and at 6 months of follow-up (p>0.05). However, at 12 months, the best corrected visual acuity values in the adjuvant and switch therapy groups were 0.46 and 0.35 LogMAR, respectively (p=0.012), and the central retinal thickness values were 344.8 and 270.9, respectively (p=0.007). Conclusions: In a real-world setting, it seems more reasonable to use intravitreal dexamethasone implant as a switch therapy rather than an adjuvant therapy for diabetic macula edema refractory to ranibizumab despite three consecutive monthly injections of ranibizumab. Patients switched to intravitreal dexamethasone implant were found to have better anatomic and visual outcomes at 12 months than those who continued ranibizumab therapy despite their less-than-optimal responses.

2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(2): e2021, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527830

RESUMO

ABSTRACT A 42-year-old female patient had vision loss and chronic epiphora in her left eye. Her best-corrected visual acuity was 10/10 in the right eye and 0.3/10 in the left eye. The anterior segment examination results were normal. In fundus examination, choroidal folds were detected. Optical coherence tomography showed elevation on the macula and choroidal folds. Ultrasonography revealed a T-sign. Magnetic resonance imaging revealed an ethmoidal mucocele that compresses the orbital tissues. Surgical treatment was performed in the otorhinolaryngology department. Postoperatively, choroidal folds recovered, and the best-corrected visual acuity improved, but subretinal fluid accumulated. During the follow-up period without any treatment, subretinal fluid totally disappeared.


RESUMO Paciente do sexo feminino, 42 anos, com perda visual e epífora crônica no olho esquerdo. Sua acuidade visual melhor corrigida foi de 10/10 no olho direito e 0,3/10 no olho esquerdo. O exame do segmento anterior foi normal. No exame de fundo de olho, foram detectadas pregas coroidais. A tomografia de coerência óptica revelou elevação na mácula e pregas coroidais. A ultrassonografia revelou sinal T. A imagem de ressonância magnética mostrou mucocele etmoidal que comprime os tecidos orbitários. O Departamento de Otorrinolaringologia realizou o tratamento cirúrgico. No pós-operatório, as dobras coroidais se recuperaram, a acuidade visual melhor corrigida foi melhorada, mas ocorreu líquido sub-retiniano. Durante o período de acompanhamento sem qualquer tratamento, o líquido sub-retiniano recuperou-se totalmente.

3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(3): e2022, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550034

RESUMO

ABSTRACT We report a case of acute methanol toxicity with unique optical coherence tomography findings. A 56-year-old man was referred to our ophthalmology clinic with a history of handmade vodka consumption and vision loss. On ophthalmologic examination, his vision was 20/100 in his right eye and 20/200 in his left eye. Bilateral mild optic disk hyperemia was detected on fundus examination. Because of the severity of systemic symptoms in such cases, it is very difficult to include optical coherence tomography in the ophthalmologic examination. However, we managed to perform optical coherence tomography and recorded shallow subretinal fluid and a prominent middle limiting membrane sign as acute retinal structural changes in the patient. The patient was treated with hemodialysis, intravenous ethanol, and sodium bicarbonate. On the fourth day of treatment, visual acuity improved to 20/20 in both eyes. In addition, the prominent middle limiting membrane sign and subretinal fluid disappeared. In this unusual case, retinal pigment epithelium damage and retinal ischemia may have contributed to the prominent middle limiting membrane and subretinal fluid, which are novel optical coherence tomography findings of methanol toxicity.

4.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(6): e2021, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513691

RESUMO

ABSTRACT This case report identified paracentral acute middle maculopathy as the cause of severe and irreversible vision loss after cataract surgery. Cataract surgeons should be aware of known risk factors for the development of paracentral acute middle maculopathy. In those patients, extra care regarding anesthesia, intraocular pressure, and some other aspects of cataract surgery must be taken. Paracentral acute middle maculopathy is currently understood as a clinical sign evident on spectral-domain optical coherence tomography, and it is probably evidence of deep ischemic insult to the retina. It should be a differential diagnosis in cases of marked low vision acuity associated with no fundus abnormalities in the immediate postoperative period, as demonstrated in the presented case.


RESUMO O presente relato de caso identificou a maculopatia média aguda paracentral como a causa de baixa de acuidade visual severa e irreversível após cirurgia de catarata. Existem fatores de risco bem estabelecidos para o desenvolvimento da maculopatia média aguda paracentral que devem ser conhecidos pelos cirurgiões de catarata. Nesse contexto cirúrgico, precauções extras no tocante a procedimentos anestésicos, pressão intraocular e alguns outros aspectos da cirurgia devem ser consideradas. A maculopatia média aguda paracentral é descrita como um sinal clínico observado no exame de tomografia de coerência óptica por domínio espectral e se trata, provavelmente, da evidência de um evento isquêmico no tecido vascular retiniano. Esse diagnóstico deve ser cogitado nos casos de perda de acuidade visual súbita no pós-operatório imediato associada com exame fundoscópico normal, como evidenciado no caso apresentado.

5.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(3): e2022, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520212

RESUMO

ABSTRACT Purpose: This study aimed to compare four depths of manual dissection for the preparation of Descemet stripping endothelial keratoplasty lamellae. Methods: Eye bank corneas were randomized into four groups according to dissection depths: Pachy-100 (incision depth = central corneal thickness-safety margin of 100 µm), Pachy-50 (safety margin of 50 µm), Pachy-0 (no safety margin), and Pachy+50 (incision depth = central corneal thickness + 50 µm). All endothelial lamellae were prepared using a standardized method of manual dissection (Pachy-DSEK). The central, paracentral (3.0-mm zone), and peripheral (6.0-mm zone) lamella thicknesses and incision depths were measured by optical coherence tomography. The 3.0-mm and 6.0-mm zone central-to-peripheral thickness ratios were calculated. Results: Endothelial perforation occurred only in the Pachy+50 group (n=3, 30%). Central lamella's thickness in Pachy-100, Pachy-50, Pachy-0, and Pachy+50 groups measured 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, and 58 ± 31 µm, respectively (p<0.001). The overall 3.0- and 6.0-mm C/P ratios were 0.97 ± 0.06 and 0.92 ± 0.14, respectively. Preoperative donor characteristics were not correlated with most thickness outcomes. The planned incision depth correlated significantly with most lamella's thickness parameters (p<0.001). The overall thickness of the lamella negatively correlated with the planned incision depth (p<0.001, r=-0.580). The best outcome was found in the Pachy-0 group, as 75% of the lamellae measured <130 µm and there was no endothelial perforation. Conclusions: By using a standardized method of dissection, most manually prepared lamellae presented a planar shape. Setting the incision depth to the central corneal thickness did not result in endothelial perforation and a high percentage of ultrathin lamellae was achieved.


RESUMO Objetivo: Comparar quatro profundidades de dissecção manual usadas no preparo de lamelas para transplante endotelial. Métodos: Córneas humanas de treinamento disponibilizadas foram randomizadas em quatro grupos: Pachy-100 (profundidade de incisão = espessura corneana central - margem de segurança de 100 µm), Pachy-50 (margem de segurança de 50 µm), Pachy-0 (sem margem de segurança) e Pachy+50 (profundidade de incisão = espessura corneana central + 50 µm). Todas as lamelas foram dissecadas através um método padronizado e já publicado (Pachy-DSEK). As espessuras das lamelas (centro, zona de 3,0mm e zona de 6,0mm) foram medidas com tomografia de coerência óptica. A razão de espessura centro-periferia foi calculada aos 3,0 e 6,0 mm de diâmetro. Resultados: Perfuração endotelial ocorreu apenas no grupo Pachy+50 (n=3, 30%). A espessura central da lamela nos grupos Pachy-100, Pachy-50, Pachy-0 e Pachy+50 foi de 185 ± 42 µm, 122 ± 29 µm, 114 ± 29 µm, e 58 ± 31 µm, respectivamente (p<0,001). As razões C/P aos 3,0 e 6,0 mm foram de 0,97 ± 0,06 e 0,92 ± 0,14, respectivamente. Os parâmetros de características do doador não se correlacionaram com os resultados de espessura de lamela. A profundidade planejada de incisão se correlacionou com a maioria dos parâmetros de espessura de lamela (p<0,001). A espessura de lamela se correlacionou negativamente com a profundidade planejada da incisão (p<0.001, r=-0,580). O melhor resultado foi observado no grupo Pachy-0, em que 75% das lamelas mediram abaixo de 130 µm e não houve perfuração endotelial. Conclusão: Através de um método padronizado de dissecção, a maioria das lamelas endoteliais apresentou uma configuração planar. O planejamento de profundidade de incisão igual à espessura corneana central resultou em alta porcentagem de lamelas ultrafinas sem ocorrência de perfuração.

6.
Arq. bras. oftalmol ; Arq. bras. oftalmol;87(6): e2022, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520246

RESUMO

ABSTRACT Purpose: To evaluate using optical coherence tomography angiography the macular and optic nerve head blood flow in pediatric patients with epilepsy treated with levetiracetam for at least 12 months. Methods: This study included 33 pediatric patients with epilepsy and 30 sex- and age-matched healthy volunteer children were included in the study. Optical coherence tomography angiography was used to evaluate the optic nerve head and macular perfusion changes. The mean ocular perfusion pressures were also calculated. Patients who were using multiple antiepileptic drugs or had a prior history of using different drugs were excluded. Results: The choriocapillaris flow area was significantly lower in the Study Group than in the Control Group (p=0.006). However, the foveal avascular zone and vessel densities of the macula in the superficial capillary plexus, deep capillary plexus, and optic nerve head of the study group were not significantly different from those of the control group (p>0.05). Moreover, no significant difference in means of mean ocular perfusion pressure was found between the two groups (p=0.211). No obvious correlation was found between treatment duration and optical coherence tomography angiography parameters or mean ocular perfusion pressure. Conclusion: Choroidal perfusion was reduced in children taking levetiracetam compared with that in the control group, whereas retinal perfusion was not affected in this optical coherence tomography angiography study.


RESUMO Objetivo: Avaliar através de angiotomografia de coerência óptica o fluxo sanguíneo macular e da cabeça do nervo óptico em pacientes pediátricos com epilepsia tratados com levetiracetam por pelo menos 12 meses. Método: Trinta e três pacientes pediátricos com epilepsia e 30 crianças voluntárias saudáveis pareadas por sexo e idade foram incluídos no estudo. A angiotomografia de coerência óptica foi utilizada para avaliar as alterações da perfusão da cabeça do nervo óptico e da macular. As médias das pressões de perfusão ocular também foram calculadas. Pacientes em uso de múltiplas drogas antiepilépticas ou com história prévia de uso de diferentes drogas foram excluídos do estudo. Resultado: A área do fluxo coriocapilar foi significativamente menor no Grupo Estudo do que no Grupo Controle (p=0,006). Entretanto, a zona avascular foveal e as densidades vasculares no plexo capilar superficial e profundo da região macular e na cabeça do nervo óptico não foram significativamente diferentes daquelas de olhos saudáveis (p>0,05). Também não houve diferença significativa entre os dois grupos em relação às médias da pressão de perfusão ocular (p=0,211). Nenhuma correlação aparente foi encontrada entre a duração do tratamento e os parâmetros da angiotomografia de coerência óptica ou a média da pressão de perfusão ocular. Conclusão: Em crianças usando levetiracetam, a perfusão coroidal mostrou-se reduzida em comparação ao grupo controle, enquanto a perfusão retiniana não foi afetada neste estudo com angiotomografia de coerência óptica.

7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(2): 97-104, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1429843

RESUMO

ABSTRACT Purpose: Neovascular age-related macular degeneration is the leading cause of vision loss in the elderly. We aimed to identify baseline predictors of visual prognosis after intravitreal conbercept injection for neovascular age-related macular degeneration. Methods: We conducted a retrospective review of 58 patients with neovascular age-related macular degeneration who were treated with intravitreal injections of conbercept 0.5 mg in routine clinical practice. Basic information such as age, sex, intraocular pressure, and disease course was collected. Best-corrected visual acuity, mean retinal sensitivity, and optical coherence tomography findings were recorded at baseline and 6 months after treatment. Logistic regression analysis was used to identify independent predictors of best-corrected visual acuity at 6 months after treatment. Results: After the 6-month treatment, the mean best-corrected visual acuity improved from 1.10 ± 0.42 logarithm of the minimum angle of resolution (logMAR) to 0.41 ± 0.18 logMAR, the mean retinal sensitivity increased from 5.13 ± 0.86 dB to 7.32 ± 1.21 dB, the mean central retinal thickness decreased from 440.38 ± 61.05 μm to 260.01 ± 24.86 μm, and the total number of hyperreflective dots and the number of hyperreflective dots in each retina layer were significantly reduced as compared with those before treatment (all p<0.05). Twenty-two patients showed improved vision, and 36 had unimproved vision. Multivariate analyses revealed that the number of subretinal hyperreflective dots, the state of external limiting membrane, baseline best-corrected visual acuity, and age were independent predictors of best-corrected visual acuity (all p<0.05). Conclusion: Poor recovery of patients after intravitreal conbercept injection may be related to the number of subretinal hyperreflective dots, the state of external limiting membrane, baseline best-corrected visual acuity, and age, which may be used as predictors of short-term visual outcomes and should be fully evaluated before operation.


RESUMO Objetivo: A degeneração macular neovascular relacionada à idade é a principal causa de perda de visão em idosos. O objetivo deste estudo foi identificar os preditores iniciais que afetam o prognóstico visual após a injeção intravítrea de combercepte para degeneração macular neovascular relacionada à idade. Métodos: Esta é uma revisão retrospectiva de 58 pacientes com degeneração macular neovascular relacionada à idade que foram tratados com injeções intravítreas de 0,5 mg de combercepte na prática clínica de rotina. Foram coletadas informações básicas, tais como idade, sexo, pressão intraocular e evolução da doença. A melhor acuidade visual corrigida, as sensibilidades retinianas médias e varreduras de tomografia de coerência óptica foram registradas no início do estudo e 6 meses após o tratamento. Foi efetuada uma análise de regressão logística para determinar os preditores independentes da melhor acuidade visual corrigida 6 meses após o tratamento. Resultados: Após 6 meses de tratamento, a média da acuidade visual melhor corrigida melhorou de 1,10 ± 0,42 para 0,41 ± 0,18 logMAR; as sensibilidades retinianas médias aumentaram de 5,13 ± 0,86 para 7,32 ± 1,21 dB; a espessura retiniana central média diminuiu de 440,38 ± 61,05 para 260,01 ± 24,86 μm; e os pontos hiper-reflexivos, tanto em números totais quanto em cada camada de retina, foram significativamente reduzidos em comparação com os valores de antes do tratamento (todos com p<0,05). Houve 22 pacientes com visão melhorada e 36 pacientes com visão não melhorada. As análises multivariadas mostraram que o número de pontos hiper-reflexivos sub-retinianos, o estado da membrana limitante externa, a melhor acuidade visual corrigida inicial e a idade foram preditores independentes para a melhor acuidade visual corrigida (todos com p<0,05). Conclusão: A má recuperação de pacientes após a injeção de combercepte intravítreo pode estar relacionada ao número de pontos hiper-reflexivos sub-retinianos, ao estado da membrana limitante externa, à acuidade visual corrigida inicial e à idade, parâmetros que podem ser usados como preditores de resultados visuais de curto prazo e devem ser totalmente avaliados antes da cirurgia.

8.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(1): 20-26, Jan.-Feb. 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1403478

RESUMO

ABSTRACT Purpose: This study aimed to examine optical coherence tomography findings in patients with opiate use disorder by comparing them with healthy controls. Methods: The study included 30 opiate use disorder patients and 30 controls. The participants' detailed biomicroscopic examinations, visual acuity, intraocular pressure, and both eye examinations were evaluated. A total of 120 eyes were evaluated using optical coherence tomography, measuring the central macular thickness, mean macular thickness, mean macular volume and retinal nerve fiber layer thickness. Moreover, all participants filled in the demographic data form and Barratt Impulsiveness Scale. Results: Upon examination of the optical coherence tomography findings, central macular thickness, mean macular thickness, and mean macular volume were thinner in both eyes in patients with opiate use disorder (p<0.01 in all measurements in both eyes). Similarly, the total values of the superior quadrant and retinal nerve fiber layer thickness were statistically significant in both eyes compared to that in the control group (p=0.007, p=0.002; p=0.049, p=0.007, in the right and left eyes, respectively). Only the left eye was positively correlated with retinal nerve fiber layer superior quadrant measurement and hospitalization (r=0.380, p=0.039). Conclusion: Our results revealed that the patients' central macular thickness, mean macular thickness, and mean macular volume values were thinner. Increase in the retinal nerve fiber layer thickness superior quadrant thickness and total value was also observed. Further studies with larger sampling groups that evaluate neuroimaging findings should be conducted.


RESUMO Objetivo: O objetivo foi investigar foi, os achados da tomografia de coerência óptica em pacientes com transtorno do uso de opiáceos, comparando-os com controles saudáveis. Métodos: O estudo incluiu 30 pacientes com transtorno do uso de opiáceos e 30 controles. Os exames biomicroscópicos detalhados de todos os participantes, acuidade visual, pressão intraocular e ambos os exames oculares foram avaliados com tomografia de coerência óptica. Um total de 120 olhos foram avaliados usando tomografia de coerência óptica, e a espessura macular central, espessura macular média, volume macular médio e a espessura da camada de fibra nervosa da retina dos participantes foram medidos. Além disso, todos os participantes preencheram o Formulário de Dados Demográficos e a Escala de Impulsividade Barratt (BIS-11). Resultados: Quando os achados de tomografia de coerência óptica foram examinados, espessura macular central, espessura macular média e volume macular médio eram mais finos de acordo com controles saudáveis em ambos os olhos em pacientes com transtorno do uso de opiáceos (p<0,01 em todas as medições em ambos os olhos). Da mesma forma, os valores totais do quadrante superior e espessura da camada de fibra nervosa da retina estavam mais em níveis estatisticamente significativos em ambos os olhos em comparação com o grupo controle (p=0,007, p=0,002; p=0,049, p=0,007, no olho direito e esquerdo, respectivamente). Estar internado em hospital e apenas a medida do quadrante superior da espessura da camada de fibra nervosa da retina do olho esquerdo associou-se positivamente (r=0,380, p=0,039). Conclusão: Em nossos resultados, descobrimos que os valores de espessura macular central, espessura macular média e volume macular médio dos pacientes eram mais finos. Verificamos também espessamento no quadrante superior e valor total da espessura da camada de fibra nervosa da retina. Nosso estudo deve ser apoiado por novos estudos com grupos de amostragem maiores, nos quais os achados de neuroimagem são avaliados.


Assuntos
Humanos , Tomografia de Coerência Óptica , Alcaloides Opiáceos , Olho , Transtornos Relacionados ao Uso de Opioides , Acuidade Visual , Estudos de Casos e Controles , Olho/diagnóstico por imagem , Pressão Intraocular , Transtornos Relacionados ao Uso de Opioides/patologia , Transtornos Relacionados ao Uso de Opioides/diagnóstico por imagem
9.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(1): 27-32, Jan.-Feb. 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1403483

RESUMO

ABSTRACT Purpose: To evaluate the relationship between subfoveal choroidal thickness and plasma asymmetrical dimethylarginine level and the severity of diabetic retinopathy in patients with type 2 diabetes mellitus. Methods: A total of 68 cases, including 15 patients without diabetic retinopathy, 17 patients with nonproliferative diabetic retinopathy, 16 patients with type 2 diabetes mellitus and proliferative diabetic retinopathy, and 20 healthy patients (control group), were enrolled in this study. Subfoveal choroidal thickness was measured manually using the enhanced depth imaging optical coherence tomography scanning program, and plasma asymmetrical dimethylarginine level was measured using a commercial micro enzyme-linked immunosorbent assay kit. Results: The subfoveal choroidal thickness values and plasma asymmetrical dimethylarginine levels were significantly different between the four groups (p<0.001 and p<0.001). The subfoveal choroidal thickness values were significantly lower in the proliferative diabetic retinopathy group than in the other three groups (no diabetic retinopathy, nonproliferative diabetic retinopathy, and control groups; p<0.001, p=0.045, and p<0.001, respectively). The plasma asymmetrical dimethylarginine levels were significantly higher in the proliferative diabetic retinopathy group than in the other three groups (p<0.001, p<0.04, and p<0.001, respectively). In addition, a significant negative correlation was also found between plasma asymmetrical dimethylarginine level and subfoveal choroidal thickness (p<0.001, r=-0.479). Conclusion: Asymmetrical dimethylarginine is an important marker of endothelial dysfunction and endogenous endothelial nitric oxide synthase inhibitor. The severity of diabetic retinopathy was related to increased plasma asymmetrical dimethylarginine level and reduced subfoveal choroidal thickness in type 2 diabetic patients with diabetic retinopathy.


RESUMO Objetivo: Avaliar a relação da espessura subfoveal da coroide e dos níveis plasmáticos de dimetil-arginina assimétrica com a gravidade da retinopatia diabética em pacientes com diabetes mellitus tipo 2. Métodos: Foram incluídos 68 casos, compreendendo 15 pacientes sem retinopatia diabética, 17 pacientes com retinopatia diabética não proliferativa, 16 pacientes com retinopatia diabética proliferativa, e 20 casos saudáveis (grupo de controle). A espessura subfoveal da coroide foi medida manualmente, usando o programa de varredura com tomografia computadorizada óptica com imagem profunda aprimorada, e os níveis plasmáticos de dimetil-arginina assimétrica foram medidos usando um kit microELISA comercial. Resultados: Os valores da espessura subfoveal da coroide e os níveis plasmáticos de dimetil-arginina assimétrica foram significativamente diferentes nos quatro grupos (p<0,001 para ambos os parâmetros). Os valores da espessura subfoveal da coroide foram significativamente menores no grupo com retinopatia diabética proliferativa do que nos outros três grupos (sem retinopatia diabética, retinopatia diabética não proliferativa e grupo de controle, com p<0,001, p=0,045 e p<0,001, respectivamente). Já os níveis plasmáticos de dimetil-arginina assimétrica foram significativamente maiores no grupo com retinopatia diabética proliferativa do que nos outros três grupos (p<0,001, p=0,04 e p<0,001, respectivamente). Além disso, também foi encontrada uma correlação negativa significativa entre os níveis plasmáticos de dimetil-arginina assimétrica e a espessura subfoveal da coroide (p<0,001, r=-0,479). Conclusão: A dimetil-arginina assimétrica é um importante marcador de disfunção endotelial e um inibidor endógeno da óxido nítrico sintase. Foi encontrada uma relação da gravidade da retinopatia diabética e de níveis elevados de dimetil-arginina assimétrica no plasma com a redução da espessura subfoveal da coroide em pacientes diabéticos tipo 2 com retinopatia diabética.


Assuntos
Humanos , Arginina , Diabetes Mellitus Tipo 2 , Retinopatia Diabética , Arginina/sangue , Arginina/análogos & derivados , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/diagnóstico
10.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(1): 79-82, Jan.-Feb. 2023. graf
Artigo em Inglês | LILACS | ID: biblio-1403484

RESUMO

ABSTRACT A 53-year-old man with a 3-day history of periorbital swelling and vision loss in the left eye was found to have septic cavernous sinus thrombosis with bilateral orbital vein involvement causing congestive orbitopathy. He was treated with an emergent canthotomy and cantholysis, intraocular pressure-lowering drops, antibiotics, anticoagulation, and serial examinations. Optical coherence tomography ultimately revealed diffuse ischemic destruction of both layers of the retina, which suggested occlusion of the ophthalmic artery or the short posterior ciliary arteries and central retinal artery without intracavernous internal carotid artery involvement. The patient remained without light perception in the left eye after treatment.


RESUMO Um homem de 53 anos, com história de 3 dias de edema periorbital e perda de visão no olho esquerdo, apresentou trombose séptica do seio cavernoso com envolvimento bilateral das veias orbitais, causando uma orbitopatia congestiva. O paciente foi tratado com uma cantotomia e cantólise de emergência, colírios para redução da pressão intraocular, antibióticos, anticoagulantes e exames seriados. A tomografia de coerência óptica finalmente demonstrou destruição isquêmica difusa de ambas as camadas da retina, sugerindo uma oclusão da artéria oftálmica ou das artérias ciliares posteriores curtas e da artéria retiniana central, com ausência de envolvimento do segmento intracavernoso da artéria carótida interna. O paciente permaneceu sem percepção luminosa no olho esquerdo.


Assuntos
Humanos , Pessoa de Meia-Idade , Trombose do Corpo Cavernoso , Trombose do Corpo Cavernoso/etiologia , Trombose do Corpo Cavernoso/diagnóstico por imagem
11.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(1): 13-19, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1403485

RESUMO

ABSTRACT Purpose: To investigate the effects of epiretinal membrane formation on the clinical outcomes of intravitreal dexamethasone implantation for macular edema secondary to branch retinal vein occlusion. Methods: This retrospective interventional case series includes the treatment of naive patients with macular edema secondary to non-ischemic branch retinal vein occlusion who underwent intravitreal dexamethasone implantation. The patients were divided into two groups as follows: Group 1 (n=25), comprised of patients with macular edema secondary to branch retinal vein occlusion without epiretinal membrane, and Group 2 (n=16), comprised of patients with macular edema secondary to branch retinal vein occlusion with an epiretinal membrane. Corrected visual acuity, central macular thickness, and central macular volume values were measured before and after treatment. The clinical outcomes of the groups were compared. Results: Mean age and male-to-female ratio were similar between the two groups (p>0.05, for both). The baseline and final corrected visual acuity values, central macular thickness, and central macular volumes of the groups were similar (p>0.05, for all). All the parameters were significantly improved after intravitreal dexamethasone implantation treatment (p<0.001, for all). The changes in central macular thickness and volume were also similar (p>0.05, for both). The mean number of intravitreal dexamethasone implantations was 2.1 ± 1.0 (range, 1-4) in Group 1 and 3.0 ± 1.2 (range, 1-5) in Group 2 (p=0.043). Conclusion: Epiretinal membrane formation had no effects on the baseline and final clinical parameters, including corrected visual acuity and central macular thickness and volume. The only parameter affected by the presence of epiretinal membrane formation is the number of intravitreal dexamethasone implantations, a greater number of which is needed for macular edema secondary to branch retinal vein occlusion with an epiretinal membrane.


RESUMO Objetivo: Investigar os efeitos da formação de uma membrana epirretiniana nos resultados clínicos da implantação intravítrea de dexametasona para edema macular secundário à oclusão de um ramo da veia retiniana. Métodos: Esta série retrospectiva de casos intervencionais inclui o tratamento de indivíduos com edema macular secundário à oclusão não isquêmica de um ramo da veia retiniana, sem tratamento prévio e que foram submetidos a implantação intravítrea de dexametasona. Os indivíduos foram divididos em dois grupos: Grupo 1 (n=25), composto por indivíduos com edema macular secundário à oclusão de um ramo da veia retiniana sem a presença de uma membrana epirretiniana, e Grupo 2 (n=16), composto por indivíduos com edema macular secundário à oclusão de um ramo da veia retiniana com a presença de uma membrana epirretiniana. Os valores da acuidade visual corrigida, espessura macular central e volume macular central foram obtidos antes e após o tratamento. Os resultados clínicos dos grupos foram comparados. Resultados: A média de idade e a proporção entre homens e mulheres foram semelhantes nos dois grupos (p>0,05 para ambos os valores). Os valores iniciais e finais da acuidade visual corrigida, espessura macular central e volume macular central foram semelhantes nos dois grupos (p>0,05 para todos os valores). Todos os parâmetros melhoraram significativamente após o tratamento com implante de dexametasona intravítrea (p<0,001 para todos os parâmetros) e as alterações na espessura macular central e no volume macular central também foram semelhantes (p>0,05 para ambos os valores). O número médio de implantações intravítreas de dexametasona foi 2,1 ± 1,0 (faixa de 1-4) no Grupo 1 e 3,0 ± 1,2 (faixa de 1-5) no Grupo 2 (p=0,043). Conclusão: A formação de uma membrana epirretiniana não tem efeitos sobre os parâmetros clínicos iniciais e finais, incluindo a acuidade visual corrigida, a espessura macular central e o volume macular central. O único parâmetro afetado pela formação de uma membrana epirretiniana é o número de implantações intravítreas de dexametasona, sendo necessário um número maior de implantações em casos de edema macular secundário à oclusão de um ramo da veia retiniana com a presença de uma membrana epirretiniana.


Assuntos
Humanos , Feminino , Masculino , Oclusão da Veia Retiniana , Edema Macular , Membrana Epirretiniana , Oclusão da Veia Retiniana/complicações , Oclusão da Veia Retiniana/tratamento farmacológico , Dexametasona , Edema Macular/etiologia , Edema Macular/tratamento farmacológico , Estudos Retrospectivos , Membrana Epirretiniana/complicações
12.
Rev. bras. oftalmol ; 82: e0026, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1441323

RESUMO

ABSTRACT Occult macular dystrophy is characterized by a slowly progressive bilateral reduction of visual acuity in patients with normal fundus and fluorescein angiography. We describe a case of a 36-year-old male patient diagnosed with this condition, after extensive investigation with multimodal imaging, electrophysiology tests, and systemic screening.


RESUMO A distrofia macular oculta é caracterizada por perda visual, lentamente progressiva, em pacientes com fundoscopia e angiografia fluoresceínica normais. Relatamos o caso de um paciente de 36 anos do sexo masculino diagnosticado com essa condição após extensa investigação com exames de imagem multimodais, eletrofisiológicos e rastreio de doenças sistêmicas.

13.
Braz. oral res. (Online) ; 37: e081, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1505910

RESUMO

Abstract: This study tested a novel in vitro dental erosion-abrasion model and the performance of cross-polarization optical coherence tomography (CP-OCT) in longitudinally monitoring the simulated lesions. Thirty human enamel specimens were prepared and randomized to receive three dental erosion-abrasion (EA) protocols: severe (s-EA, lemon juice/pH:2.5/4.25%w/v citric acid), moderate (m-EA, grapefruit juice/pH:3.5/1.03%w/v citric acid) and no-EA (water, control). EA challenge was performed by exposing the specimens to acidic solutions 4x/day and to brushing 2x/day with 1:3 fluoridated toothpaste slurry, for 14 days. Enamel thickness measurements were obtained using CP-OCT at baseline (D0), 7 (D7) and 14 days (D14) and micro-computed tomography (micro-CT) at D14. Enamel surface loss was measured with both CP-OCT and optical profilometry at D0, D7 and D14. Data was analyzed with repeated-measures ANOVA and Pearson's correlation (r) (α = 0.05). CP-OCT enamel thickness decreased over time in the s-EA group (D0 >D7 > D14, p < 0.001) and m-EA group (D0 > D14, p = 0.019) but did not change in the no-EA group (p = 0.30). Overall, CP-OCT and micro-CT results at D14 correlated moderately (r = 0.73). CP-OCT surface loss was highest for s-EA (p <0.001) but did not differ between moderate and no-EA (p = 0.25). Enamel surface loss with profilometry increased with severity (no-EA>m-EA>s-EA, p < 0.001). D14 surface loss was higher than D7 for both methods except for the no-EA group with profilometry. CP-OCT and profilometry had moderate overall correlation (r = 0.70). Our results revealed that the currently proposed in vitro dental erosion-abrasion model is valid and could simulate lesions of different severities over time. CP-OCT was a suitable method for monitoring the EA lesions.

14.
Arq. bras. oftalmol ; Arq. bras. oftalmol;86(5): e2021, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513686

RESUMO

Abstract Purpose: The purpose of this study was to assess the optic nerve head microvascular changes in pseudoexfoliative and primary open-angle glaucoma and define the relationship between vessel density and retinal nerve fiber layer thickness. Methods: This observational cross-sectional study assessed 72 eyes with primary open-angle glaucoma, 41 eyes with pseudoexfoliative glaucoma, and 60 healthy eyes. On the basis of optic nerve head-centered, 4.5 mm × 4.5 mm scan size images, we evaluated the vessel density, as well as the peripapillary sector, inside disk, and all sectoral quadrants. Results: Both glaucoma Groups had lower vessel density in all regions compared with the healthy Group (p<0.05 for all variables). Vessel densities of the nasal inferior, inferior nasal, and inferior temporal sectors in both glaucoma Groups showed similar results (p=0.157, p=0.128, p=0.143, respectively). Eyes with pseudoexfoliative glaucoma had significantly lower vessel densities than eyes with primary open-angle glaucoma in all other regions (p<0.05 for all variables). For both glaucoma Groups, the average retinal nerve fiber layer thickness positively correlated with vessel density in all peripapillary sectors (p<0.05 for all variables). Conclusions: Reduction in vessel density correlated with the thinning of retinal nerve fiber layer in both glaucoma Groups. Decreased vessel density in the optic nerve head can be used to demonstrate the microvascular pathologies and possible ischemic changes that lead to faster progression and worse prognosis in pseudoexfoliative glaucoma.


Resumo Objetivo: Atribuir variações microvasculares à cabeça do nervo óptico no glaucoma pseudoesfoliativo e primário de ângulo aberto, e definir a relação entre a densidade dos vasos e a espessura da camada de fibras nervosas da retina. Métodos: Este estudo foi projetado como observacional e transversal. Foram incluídos 72 olhos com glaucoma primário de ângulo aberto, 41 olhos com glaucoma pseudoesfoliativo e 60 olhos saudáveis. Foram obtidas imagens do nervo óptico centralizadas na cabeça do nervo com 4,5 × 4,5 mm de tamanho de varredura. A densidade vascular foi avaliada em toda a imagem, na área peripapilar, dentro do disco óptico e em todos os quadrantes setoriais. Resultados: Em todas as regiões, a densidade vascular foi menor em ambos os grupos com glaucoma que nos olhos saudáveis (p<0,05 para todas as variáveis). Em ambos os grupos com glaucoma, a densidade vascular mostrou resultados semelhantes nos setores nasal inferior, inferior nasal e temporal inferior (respectivamente, p=0,157, p=0,128 e p=0,143). Os olhos com glaucoma pseudoesfoliativo mostraram densidade vascular acentuadamente menor que nos olhos com glaucoma primário de ângulo aberto em todas as outras regiões (p<0,05). A espessura média da camada de fibras nervosas da retina demonstrou uma correlação positiva com a densidade vascular em todos os setores peripapilares em ambos os grupos com glaucoma (p<0,05 para todas as variáveis). Conclusões: A redução da densidade vascular foi correlacionada a uma redução da espessura da camada de fibras nervosas da retina em ambos os grupos com glaucoma. A densidade vascular reduzida na cabeça do nervo óptico poderia ser usada para provar patologias microvasculares e possíveis alterações isquêmicas responsáveis por uma evolução mais rápida e um prognóstico pior no glaucoma pseudoesfoliativo.

15.
An. bras. dermatol ; An. bras. dermatol;98(6): 781-786, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520044

RESUMO

Abstract Background Previous studies have generally focused on dry eye test abnormalities and ocular involvements such as uveitis, and blepharitis in psoriasis. Psoriasis area severity ındex (PASI), which is used to assess psoriasis severity, is a time-consuming and complex tool. Objective To evaluate the relationship between disease severity and central corneal epithelial thickness (CCET) in psoriasis. Methods 175 eyes of 175 psoriasis patients and 57 eyes of 57 healthy individuals as a control group was included in this study. Psoriasis patients were divided into three subgroups according to PASI score as < 10 mild, 10‒20 moderate and > 20 severe. CCET was measured by spectral domain-optical coherence tomography (SD-OCT), and mean values were recorded. Mean CCET values were compared between the psoriasis groups and the control group. Additionally, the relationship between PASI score and CCET was examined. Results The mean CCET value was 58.06 ± 3.1 μm in the mild group, 60.10 ± 5.0 μm in the moderate group, 65.75 ± 6.3 μm in the severe group and 56.16 ± 3.1 μm in the control group. It was determined that the mean CCET value was significantly higher in all psoriasis groups compared to the control group (p < 0.001). The mean CCET value was significantly higher in the moderate psoriasis group than in the mild psoriasis group (p = 0.018), and in the severe psoriasis group compared to the moderate psoriasis group (p < 0.001). There was a strong positive correlation between PASI score and CCET (p < 0.001, r = 0.519). Study limitations Cross-sectional design and a relatively small number of participants. Conclusions There is a strong positive correlation between psoriasis severity and CCET. Contactless measurement of CCET by SD-OCT can be an indicator of psoriasis severity.

16.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(6): 584-589, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403451

RESUMO

ABSTRACT Purpose: To determine the effects of vitamin D deficiency on retinal microvascularity using optical coherence tomography angiography. Methods: This study was designed as an observational case-control study. Ninety-eight eyes of patients with vitamin D deficiency and 96 eyes of healthy participants with serum vitamin D level >30 ng/mL were studied. Macula centered, 6.00 × 6.00 mm scan size images were taken. The vessel densities in the superficial and deep retinal capillary plexus, foveal avascular zone area, and choriocapillaris flow area were measured. Results: The groups were comparable in terms of best-corrected visual acuity, sex, axial length, refractive error, age, and adjusted intraocular pressure. The average vitamin D level was significantly lower in the study group (p=0.021). The whole, parafoveal, and perifoveal vessel densities in the deep capillary plexus were considerably higher in the study group than in the control group (p=0.012, p=0.014, and p=0.023, respectively). The foveal avascular zone area and the choriocapillaris flow area were similar in both groups (p=0.37 and p=0.27, respectively) there was a strong negative correlation between the serum vitamin D level and vessel density in the whole image, parafoveal, and perifoveal regions of the deep capillary plexus in the study group (Spearman's rho=-0.71, p=0.043; Spearman's rho= -0.79, p=0.011; and Spearman's rho = -0.74, p=0.032; respectively). Conclusion: An increase in vessel density might originate from vascular structural changes caused by vitamin D deficiency. The increased vessel density, especially in the deep capillary plexus, can enable early diagnosis of vitamin D-associated vasculopathy.


RESUMO Objetivo: Determinar os efeitos da deficiência de vitamina D nos microvasos da retina usando angiotomografia de coerência óptica. Métodos: Este estudo foi planejado para ser do tipo caso-controle observacional. Foram avaliados 98 olhos de pacientes com deficiência de vitamina D e 96 olhos de participantes saudáveis com nível sérico de vitamina D superior a 30 ng/mL. Foram adquiridas imagens de varredura centralizadas na mácula, com um tamanho de 6,00 × 6,00 mm. Mediram-se a densidade dos vasos nos plexos capilares superficial e profundo da retina, a área da zona avascular foveal e a área do fluxo coriocapilar. Resultados: Os grupos mostraram-se semelhantes em relação à melhor acuidade visual corrigida, ao gênero, ao comprimento axial, ao erro refrativo, à idade e à pressão intraocular ajustada. O nível médio de vitamina D foi significativamente menor no grupo de estudo (p=0,021). As densidades total, parafoveal e perifoveal do plexo capilar profundo foram significativamente maiores no grupo de estudo que no grupo controle (respectivamente, p=0,012, p=0,014 e p=0,023). As áreas da zona avascular foveal e do fluxo coriocapilar foram semelhantes nos dois grupos (respectivamente, p=0,37 e p=0,27). Além disso, houve uma forte correlação negativa do nível sérico de vitamina D com as densidades vasculares medidas em toda a imagem e nas regiões parafoveais e perifoveais do plexo capilar profundo no grupo de estudo (respectivamente, ρ de Spearman = −0,71, p=0,043; ρ de Spearman = −0,79, p=0,011; e ρ de Spearman = −0,74, p=0,032). Conclusão: Pode ocorrer um aumento na densidade vascular da retina devido a alterações estruturais dos vasos causadas pela deficiência de vitamina D. O aumento da densidade vascular, especialmente no plexo capilar profundo, pode ser usado para o diagnóstico precoce da vasculopatia associada à deficiência de vitamina D.

17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(5): 472-477, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403432

RESUMO

ABSTRACT Purpose: This study aimed to compare the anatomical and visual outcomes of idiopathic epiretinal membrane peeling surgery, with and without foveal herniation. Methods: This retrospective, comparative, two-center study included age- and sex-matched patients exhibiting an idiopathic epiretinal membrane with and without foveal herniation (epiretinal membrane + foveal herniation group and epiretinal-membrane-only group, respectively). The baseline best-corrected visual acuity and central foveal thickness were compared within the groups through months 1, 3, 6, and 12 of follow-up postoperatively. Then, changes in these two parameters at all follow-up points were compared between the groups. Results: We enrolled 16 patients per study group. The baseline best-corrected visual acuity and central foveal thickness were not significantly different between the two groups (p>0.05). Compared with the baseline, both the best-corrected visual acuity and central foveal thickness improved significantly in both groups in all follow-ups (p<0.05), except for the best-corrected visual acuity of the epiretinal-membrane-only group after month 1 (p<0.05). The mean best-corrected visual acuity improvement after month 1 and the mean central foveal thickness reduction after months 1, 3, and 6 were significantly better in the foveal herniation + epiretinal membrane group than in the epiretinal-membrane-only group (p<0.05). However, the best-corrected visual acuity and central foveal thickness changes were not significantly different between the groups at the final visit (p>0.05). Conclusions: Although epiretinal membrane + foveal herniation demonstrated prompt anatomical and functional improvement, foveal herniation occurrence did not affect the final surgical outcomes in patients with idiopathic epiretinal membrane.


RESUMO Objetivo: Comparar os resultados anatômicos e visuais da cirurgia com peeling da membrana epirretiniana idio pática na presença e ausência de herniação foveal. Métodos: Estudo retrospectivo, comparativo, de dois centros. Pacientes com membrana epirretiniana idiopática pareados por idade e sexo com herniação foveal (grupo membrana epirretiniana + herniação foveal) e sem herniação foveal (grupo apenas com membrana epirretiniana) foram incluídos. Mudanças na acuidade visual melhor corrigida e espessura foveal central em todos os pontos de acompanhamento foram comparadas entre os grupos. A linha de base da melhor acuidade visual corrigida e a espessura foveal central foram comparadas dentro dos grupos no 1º, 3º, 6º e 12º meses de acompanhamento após a cirurgia Resultados: Dezesseis pacientes com membrana epirretiniana + olhos com herniação foveal e 16 pacientes com olhos apenas com membrana epirretiniana foram incluídos no estudo. Não houve diferença significativa entre os grupos na linha de base com melhor acuidade visual corrigida e espessura foveal central (p>0,05), exceto para a melhor acuidade visual corrigida do grupo da membrana epirretiniana após o 1º mês (p> 0,05), a melhor acuidade visual corrigida e a espessura foveal central melhoraram significativamente em ambos os grupos em todos os acompanhamentos em comparação com a linha de base (p<0,05). A média da melhor acuidade visual corrigida melhorou após o 1º mês e a redução média da espessura foveal central após o 1º, 3º e 6º meses foram significativamente melhores no grupo de herniação foveal + membrana epirretiniana do que no grupo com apenas membrana epirretiniana (p<0,05). Não houve diferença significativa na melhor acuidade visual corrigida e nas alterações da espessura foveal central entre os grupos na visita final (p>0,05). Conclusões: Embora uma melhora anatômica e funcional bem mais precoce tenha sido mostrada no grupo membrana epirretiniana + herniação foveal, a presença de her niação foveal não afetou os resultados cirúrgicos finais em pacientes com membrana epirretiniana idiopática.

18.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(5): 498-505, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403442

RESUMO

ABSTRACT Purpose: To assess choroidal changes using enhanced depth imaging optical coherence tomography in coronavirus disease (COVID-19). Methods: Thirty-two patients with moderate COVID-19 and 34 healthy subjects were included in the study. Choroidal thickness was measured at 3 points as follows: at the subfovea, 1500 mm nasal to the fovea, and 1500 mm temporal to the fovea. The total choroidal area, luminal area, stromal area, and choroidal vascular index were measured with Image-J. All the measurements were performed during the disease and at 4 months after remission. Results: In the patient group, the subfoveal, nasal, and temporal choroidal thicknesses were decreased as compared with those in the controls, but without statistically significant differences (p=0.534, p=0.437, and p=0.077, respectively). The mean total choroidal, stromal, and luminal areas and choroidal vascular index were statistically significantly decreased in the patient group (p<0.001, p=0.001, p=0.001, and p=0.003; respectively). At 4 months after remission, the choroidal structural parameters and choroidal vascular index revealed statistically significant increases as compared with the baseline measurements in the patients with COVID-19 (all p<0.001 and p=0.047, respectively). Conclusion: The choroidal vascular and stromal parameters showed significant transient decreases during the disease course of COVID-19.


RESUMO Objetivo: Avaliar alterações da coroide através de imagens de tomografia de coerência óptica (OCT) com pro fundidade realçada na doença por coronavírus de 2019 (COVID-19). Métodos: Foram incluídos no estudo 32 pacientes com COVID-19 moderada e 34 indivíduos saudáveis. A espessura da coroide foi medida em 3 pontos: subfoveal, a 1500 mm da fóvea na direção nasal e a 1500 mm da fóvea na direção temporal. A área total da coroide, a área luminal, a área estromal e o índice vascular da coroide foram medidos com o programa ImageJ. Todas as medições foram feitas durante a doença ativa e 4 meses após a remissão. Resultados: No grupo de pacientes, as espessuras subfoveal, nasal e temporal da coroide mostraram-se reduzidas em comparação com os controles. A diferença não foi estatisticamente significativa (respectivamente, p=0,534, p=0,437 e p=0,077). As médias das áreas total da coroide, estromal e luminal, bem como o índice vascular da coroide, mostraram-se diminuídos com significância estatística no grupo de pacientes (respectivamente, p<0,001, p=0,001, p=0,001 e p=0,003). Aos 4 meses após a remissão, os parâmetros estruturais e o índice vascular da coroide revelaram um aumento estatisticamente significativo em pacientes com COVID-19, em comparação com as medidas iniciais (todos os valores de p<0,001 para os parâmetros estruturais e p=0,047 para o índice vascular da coroide). Conclusão: Os parâmetros vasculares da coroide e do estroma mostraram uma diminuição transitória, mas significativa em pacientes com COVID-19 durante a doença.

19.
Iatreia ; Iatreia;35(2): 98-107, abr.-jun. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1421624

RESUMO

Resumen Introducción: la diabetes mellitus (DM) es una epidemia mundial. La retinopatía diabética proliferativa (RDP), el edema macular diabético (EMD) y las complicaciones de la diabetes mellitus son las principales causas de discapacidad visual y ceguera en los adultos en la edad productiva. Aproximadamente, 1 de cada 3 personas con DM tiene retinopatía diabética (RD) y 1 de cada 10 tiene RDP o EMD. En el presente estudio se hace énfasis en esta última, siendo el primero con estas características en Colombia. Métodos: estudio transversal descriptivo donde se incluyeron 1.203 pacientes con diagnóstico de DM atendidos en la jornada "No más ciegos por Diabetes" del Hospital San Vicente Fundación de Medellín, en el 2017 y 2018. Se evaluó la presencia de RD y EMD clínico y sus características epidemiológicas en un análisis bivariado. Resultados: del total de pacientes con DM tamizados (1.203), el 5,4 % (65) tenían EMD; dentro de estos, el 7,7 % tenía DM tipo 1 y el 89,2% DM tipo 2. El 10,8 % tenía RDP, 73,8% tenía RD no proliferativo (RDNP). En un 93,8 % se hizo diagnósticos de novo de RD. La mediana del tiempo de la diabetes fue de 14 años, con un rango intercuartílico (RIQ) entre 7 y 19,5. La mediana de la hemoglobina glicosilada (HbA1C) fue de 8,3 % (RIQ: 7,1-11). De 65 pacientes con EMD, 28 (56 ojos de los 130 con EMD) fueron estudiados con tomografía de coherencia óptica (OCT) y al 85,7 % se le confirmó EMD. La mediana del grosor macular central fue de 249 micras (RIQ: 231-341) en los pacientes con EMD por OCT (n = 48 ojos). Conclusión: las complicaciones de la diabetes son más prevalentes en los pacientes con RD. La media del tiempo de aparición de EMD fue similar al tiempo de inicio de las complicaciones microvasculares de la diabetes reportada en la literatura, pero debe ser considerada en el contexto del control metabólico de los pacientes.


Summary Introduction: Diabetes Mellitus (DM) is a worldwide epidemic disease, with significant microvascular compromise. Proliferative diabetic retinopathy (PDR) as well as diabetic macular edema (DME) are currently two of the leading causes of visual impairment and blindness in adults of productive age. Approximately one in three people with DM have diabetic retinopathy (DR), and 1 in 10 have PDR or DME. This study emphasizes in the last one, being the first one with these characteristics in Colombia. Methods: This descriptive cross-sectional study includes 1203 patients diagnosed with DM evaluated in the "No more blindness due to diabetes" diabetic retinopathy-screening program of the San Vicente Foundation Hospital in Medellín between 2017 and 2018. The presence of DR and clinical macular edema with the epidemiologic variables were evaluated in a bivariate analysis. Results: From the total number of patients with DM screened (1203), 5,4% (65) had DME, 7,7% had DM type 1 and 89,2% had DM type 2, 10,8% had PDR and 73.8% had nonproliferative diabetic retinopathy NPDR. Most of the patients (93,8%) were diagnosed de novo with DR. The median illness time was 14 years with interquartile range (IQR) between 7 and 19,5. The median glycosylated hemoglobin (HbA1C) was 8.3% (IQR:7,1-11). Optical coherence tomography (OCT) study was done in 28 out of 65 patients with DME (56 out of 130 eyes with DME), in which 85.7% of patients were confirmed to have DME and the mean central macular thickness was 249 microns (IQR:231-341) (n=48 eyes). Conclusion: DM complications were more frequent in patients suffering from DR. The median onset time of DME symptoms was found to be similar to the time of microvascular complications appear; however, it should be considered along with the patient's metabolic control.

20.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(3): 294-296, May-June 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383793

RESUMO

ABSTRACT Improper closure of the embryonic fissure results in ocular coloboma. Optic nerve head drusen are hyaline deposits located anterior to the lamina cribosa that grow and calcify over time. It is rarely associated with ocular coloboma, with only two cases reported. We present a patient with an irido-chorioretinal coloboma, poorly defined optic nerve limits in the right eye, and increased papillary vascular ramification and peripapillary atrophy in the left eye, without any visible drusen. Fundus autofluorescence, high-resolution optical coherence tomography, and B-scan ultrasonography confirmed the diagnosis of bilateral buried optic nerve head drusen. The association between irido-chorioretinal colobomas and optic nerve drusen in the absence of a systemic disease is exceptional. Our case demonstrates that multimodal imaging is important to correctly diagnose buried optic nerve head drusen.


RESUMO O coloboma ocular é o resultado de um fechamento impróprio da fissura embrionária. As drusas da cabeça do nervo óptico são depósitos hialinos localizados anteriormente à lâmina cribosa que crescem e se calcificam com o tempo. A associação de ambos é rara, com apenas dois casos descritos na literatura. Apresentamos um paciente com coloboma irido-coriorretiniano e limites do nervo óptico mal definidos em seu olho direito, e aumento da ramificação vascular papilar e atrofia peripapilar em seu olho esquerdo, sem drusas visíveis. Autofluorescência de fundo, tomografia de coerência óptica de alta resolução e ultrassonografia B-scan foram realizadas confirmando o diagnóstico de drusas enterradas bilaterais da cabeça do nervo óptico. A associação entre colobomas irido-coriorretinianos com drusas do nervo óptico na ausência de doença sistêmica é excepcional. Nosso caso demonstra a importância da imagem multimodal para o diagnóstico correto de drusas enterradas de cabeça do nervo óptico.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA