Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Rev. méd. Maule ; 39(1): 13-17, mayo. 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1562909

RESUMO

It is presented as an innovative technique in the treatment of atrial fibrillation, with the aim of improving the quality of life of affected patients. OBJECTIVES: The study aims to describe the ablation procedure using the Boston Scientific System Farapulse medical equipment and analyze the results in a specific clinical case. METHODS: A pulmonary vein ablation procedure was performed using the aforementioned equipment. Details of the procedure were recorded, including catheter placement and applications performed in each pulmonary vein. RESULTS: Good tolerance was observed by the patient during the procedure, with an adequate number of applications in each pulmonary vein. Postablation electrocardiogram showed no significant abnormalities, suggesting electrical stability of the heart. It is concluded that the pulsed field pulmonary vein ablation technique using the Boston Scientific System medical equipment is safe and effective in the treatment of atrial fibrillation.


Se presenta como una técnica innovadora en el tratamiento de la fibrilación auricular, con el objetivo de mejorar la calidad de vida de los pacientes afectados. OBJETIVOS: El estudio tiene como objetivo describir el procedimiento de ablación utilizando el equipo médico Boston Scientific System Farapulse y analizar los resultados en un caso clínico específico. Métodos: Se realizó un procedimiento de ablación de venas pulmonares utilizando el equipo mencionado. Se registraron los detalles del procedimiento, incluyendo la colocación de catéteres y las aplicaciones realizadas en cada vena pulmonar. RESULTADOS: Se observó una buena tolerancia por parte del paciente durante el procedimiento, con un número adecuado de aplicaciones en cada vena pulmonar. El electrocardiograma postablación no mostró anomalías significativas, lo que sugiere una estabilidad eléctrica del corazón. Se concluye que la técnica de ablación de venas pulmonares con campo pulsado utilizando el equipo médico Boston Scientific System es segura y eficaz en el tratamiento de la fibrilación auricular.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Reprodutibilidade dos Testes , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
2.
Rev. urug. cardiol ; 38(1): e405, 2023. ilus, tab
Artigo em Espanhol | LILACS, UY-BNMED, BNUY | ID: biblio-1515549

RESUMO

La ablación de las venas pulmonares se ha convertido en un tratamiento clave para fibrilación auricular (FA). Sin embargo, pueden ocurrir recurrencias. La estrategia disponible para la ablación después de una recurrencia de FA es controvertida, compleja y desafiante, y la información es limitada. Mediante la presentación de una serie de casos se resumen y discuten elementos clave en la comprensión y tratamiento del paciente con FA recurrente sintomática después de un procedimiento inicial de ablación de venas pulmonares que requiere un nuevo procedimiento de ablación. En las últimas décadas se ha obtenido una mejor comprensión de los mecanismos fisiopatológicos implicados en la FA recurrente posterior a ablación de venas pulmonares, lo que permite identificar factores asociados, crear scores predictores e implementar técnicas de optimización o estrategias adicionales para mejorar la durabilidad y la eficacia del aislamiento de venas pulmonares. Debido a que la reconexión de venas pulmonares es un hallazgo típico durante los procedimientos repetidos, ésta debe ser considerada el objetivo principal de una nueva ablación. Las estrategias de ablación adicional (desencadenantes extrapulmonares o sustratos arritmogénicos) son controvertidas y requieren investigaciones futuras.


Pulmonary vein ablation has become a key treatment for atrial fibrillation (AF). However, recurrences can occur. The ideal strategy for ablation after AF recurrence is controversial, complex, and challenging, with limited data available. By presenting a series of cases, we summarize and discuss key elements in the understanding and treatment of patients with symptomatic recurrent AF after an initial pulmonary vein ablation procedure who are subjected to a new ablation procedure. In recent decades, there has been a better understanding of the pathophysiological mechanisms involved in recurrent AF after pulmonary vein ablation, making it possible to identify associated factors, create predictive scores and implement optimization techniques or additional strategies to improve the durability and efficacy of pulmonary veins isolation. Because pulmonary vein reconnection is a typical finding during repeat procedures, it should be considered the primary goal for a repeat ablation procedure. Additional ablation strategies (extrapulmonary triggers or arrhythmogenic substrates) are controversial and require further investigation.


A ablação das veias pulmonares tornou-se um tratamento chave para fibrilação atrial (FA). No entanto, podem ocorrer recorrências. A estratégia ideal para a ablação após uma recorrência da FA é controversa, complexa e desafiadora e existem dados limitados. Através da apresentação de uma série de casos resumimos e discutimos elementos chave no entendimento e tratamento do paciente com FA recorrente sintomática após um procedimento inicial de ablação de veias pulmonares, que são submetidos a um novo procedimento de ablação. Nas últimas décadas obteve-se uma melhor compressão dos mecanismos fisiopatológicos envolvidos na FA recorrente pós-ablação de veias pulmonares, isso permite identificar fatores associados, criar scores preditores, implementar técnicas de otimização ou estratégias adicionais para melhorar a durabilidade e eficácia do isolamento de veias pulmonares. Dado que a reconexão de veias pulmonares é um achado típico durante os procedimentos repetidos deve ser considerado o objetivo principal para uma nova ablação. As estratégias de ablação adicional (desencadeadores extrapulmonares ou substratos arritmogénicos) são controversas e requerem investigação futura.


Assuntos
Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/fisiopatologia , Recidiva , Fibrilação Atrial/fisiopatologia
3.
Rev. chil. cardiol ; 41(2): 130-139, ago. 2022. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1407760

RESUMO

RESUMEN La ablación con radiofrecuencia (RF) o con Criobalón (CRIO) en pacientes con fibrilación auricular (FA) paroxística y persistente es un tratamiento seguro y eficaz en pacientes seleccionados. Datos recientes demuestran que la ablación proporciona mejores resultados en comparación con fármacos antiarrítmicos (FAA) en el tratamiento de la FA temprana. Los estudios que comparan RF y CRIO mostraron una eficacia y seguridad comparables en el aislamiento de venas pulmonares (PVI) para pacientes con FA paroxística sintomática. OBJETIVOS: Revisar estudios clínicos que comparan el tratamiento de la FA con ablación versus FAA como terapia de primera línea en pacientes con FA sin tratamiento previo. La eficacia y la seguridad se compararán entre las dos cohortes y entre los subgrupos. MÉTODO: Se incluye un total de 6 estudios en los que participaron 1212 pacientes con FA: 609 pacientes fueron aleatorizados a ablación de FA y 603 a tratamiento farmacológico En comparación con el tratamiento con FAA, la ablación se asoció con una reducción en la recurrencia de arritmias auriculares (32,3 % frente a 53 %; riesgo relativo [RR], 0,62; IC del 95 %, 0,51-0,74; P < 0,001; I 2 = 40 %, NNT: 5). El uso de ablación también se asoció con una reducción de las arritmias auriculares sintomáticas (11,8 % frente a 26,4 %; RR, 0,44; IC del 95 %, 0,27-0,72; P = 0,001; I 2 = 54%) y hospitalización (5,6% vs 18,7%; RR, 0,32; IC 95%, 0,19-0,53; P< 0,001) sin diferencias significativas en los eventos adversos graves entre los grupos (4,2 % frente a 2,8 %; RR, 1,52; IC del 95 %, 0,81-2,85; P = 0,19). CONCLUSIÓN: En pacientes con FA paroxística, una estrategia de control precoz del ritmo cardíaco, se asocia con una mayor probabilidad de supervivencia, menos procedimientos repetidos, menos hospitalizaciones y, probablemente, una disminución en la progresión a FA persistente.


INTRODUCTION: Radiofrequency (RF) or cryoballoon (CRYO) ablation in patients with paroxysmal and persistent atrial fibrillation (AF) are safe and effective treatments in selected patients. Recent data show that ablation provides better results compared to antiarrhythmic drugs (AAD) in the treatment of early AF. Studies comparing RF and CRYO showed comparable efficacy and safety in pulmonary vein isolation (PVI) for patients with symptomatic paroxysmal AF. OBJETIVES: Review of clinical trials comparing treatment of AF with ablation versus AAD as first-line therapy in patients with AF with no previous treatment. Efficacy and safety are compared between the two cohorts and between subgroups. METHODS: A total of 6 studies involving -212 AF patients were included: 609 were randomized to AF ablation and 603 to pharmacological treatment. Ablation, compared with AAD, was associated with a reduction in recurrence of atrial arrhythmias (32.3% vs. 53%; relative risk [RR], 0.62; 95% CI, 0.51-0.74, P< 0.001, I2 = 40%, NNT: 5). The use of ablation was also associated with a reduction in symptomatic atrial arrhythmias (11.8% vs. 26.4%; RR, 0.44; 95% CI, 0.27-0.72; P= 0.001; I2 = 54%) and hospitalization (5.6% vs 18.7%; RR, 0.32; 95% CI, 0.19-0.53; P <0.001) with no significant differences in major adverse events (4.2% vs. 2.8%; RR, 1.52; 95% CI, 0.81-2.85; P=0.19). CONCLUSION: In patients with paroxysmal AF, an early cardiac rhythm control with ablation is associated with a higher probability of survival, fewer repeat procedures, fewer hospitalizations, and probably a decrease in progression to persistent AF.


Assuntos
Humanos , Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter , Flutter Atrial/diagnóstico , Ablação por Radiofrequência/métodos , Antiarrítmicos/uso terapêutico
4.
Rev. méd. Chile ; 150(5): 618-624, mayo 2022. graf
Artigo em Espanhol | LILACS | ID: biblio-1409840

RESUMO

BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) is beneficial in patients with symptomatic severe Aortic Stenosis (AS). There is no consensus about the best anticoagulation strategy for patients with a recent TAVI and with atrial fibrillation (AF). Direct oral anticoagulants (DOACs) are effective to prevent embolic events with a significant lower incidence of bleeding. There is scarce evidence about the use of these drugs in patients undergoing TAVI. AIM: To assess the management of anticoagulation at the moment of discharge of patients with AF and TAVI. Material and Methods: A four question survey was sent to cardiologists involved in TAVI programs in different international centers. Results: The survey was answered by 72 interventional cardiologists. Even with the lack of randomized evidence, in most of the scenarios DOACs are prescribed at discharge in patients with indication for anticoagulation. Also, in patients with high bleeding risk, most cardiologists would perform a left atrial appendage closure. In patients with concomitant coronary artery disease, if a stent was recently implanted, prescription of the combination of a DOAC and one antiplatelet drug was the most common answer. In patients with a former coronary angioplasty, DOAC or Warfarin was the therapy of choice. CONCLUSIONS: In the absence of randomized data, interventional cardiologists prescribe DOACs at discharge to patients with AF and TAVI, without following current guidelines in most cases.


Assuntos
Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Varfarina/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Anticoagulantes/uso terapêutico
6.
Arq. bras. cardiol ; 117(1): 100-105, July. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1285226

RESUMO

Resumo Fundamento Na fibrilação atrial paroxística (FAP), o isolamento das veias pulmonares com criobalão (IVP-CB) tem eficácia semelhante à da ablação por radiofrequência (IVP-RF). Em procedimentos de reablação após IVP-RF, a reconexão das VPs é alta, ao passo que em pacientes com reablação após IVP-CB, as informações são escassas. Objetivo Determinar os locais de reconexão das VPs em pacientes que foram submetidos à reablação após IVP-CB inicial. Métodos Pacientes que foram submetidos a um procedimento de reablação de fibrilação atrial, após um IVP-CB inicial para FAP foram incluídos. O mapeamento eletroanatômico do AE foi utilizado. Um local de reconexão foi definido com a presença de uma voltagem de 0,3mV ou maior nas VPs e condução unidirecional ou bidirecional nas VPs durante o ritmo sinusal. Os locais de reconexão foram identificados por meio de corte paraesternal longitudinal e posteriormente ablacionados com radiofrequência. Resultados Dos 165 pacientes submetidos ao IVP inicial, 27 necessitaram reablações, dos quais 18 (66,6%) eram do sexo masculino, com média de idade de 55+12,3 anos. O tempo de recorrência foi de 8,9+6,4 meses. A reconexão das VPs foi encontrada em 21 (77,8%) pacientes. Houve um total de 132 lacunas de condução, seis por paciente, 3,6 por VP. Um número significativo de lacunas ocorreu na região ântero-superior da VP superior esquerda (VPSE) e nas regiões septal e inferior da VP superior direita (VPSD). Conclusões As VPs superiores apresentaram os locais de maior reconexão, principalmente na região anterior da VPSE e na região septal da VPSD. A razão por trás disso pode ser devido à maior espessura da parede atrial e à dificuldade em alcançar o contato de criobalão adequado.


Abstract Background In paroxysmal atrial fibrillation (PAF), pulmonary vein isolation using cryoballoon (CB-PVI) has similar efficacy as radiofrequency ablation (RF-PVI) has. In redo ablation procedures following RF-PVI, PV reconnection is high, whereas in patients with redo following CB-PVI, information is scarce. Objective To determine the sites of PV reconnection in patients who underwent redo ablation after initial CB-PVI. Methods Patients who underwent an AF redo procedure, following an initial CB-PVI for PAF were included. LA electroanatomic mapping was used. A reconnection site was defined as the presence of a voltage of 0.3mV or greater in the PV and unidirectional or bidirectional conduction in the PV during sinus rhythm. Reconnections sites were identified using a clock-face view description and were ablated with radiofrequency afterwards. Results Out of the 165 patients who underwent initial PVI, 27 required redo ablations, of which 18 (66.6%) were males, with a mean age of 55+12.3 years. The time of recurrence was 8.9+6.4 months. PV reconnection was found in 21 (77.8%) patients. There was a total of 132 conduction gaps, six per patient, 3.6 per PV. A significant number of gaps were in the anterosuperior region of the left superior PV (LSPV), and in the septal and inferior regions of the right superior PV (RSPV). Conclusions The upper PVs had the most reconnection sites, mostly at the anterior region of the LSPV and the septal region of the RSPV. The reason behind this may be due to greater atrial wall thickness, and difficulty in achieving adequate cryoballoon contact.


Assuntos
Humanos , Masculino , Adulto , Idoso , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Recidiva , Resultado do Tratamento , Pessoa de Meia-Idade
8.
Arq. bras. cardiol ; 116(2): 334-343, fev. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1153006

RESUMO

Resumo Após mais de 20 anos desde sua utilização inicial, a ablação por cateter se tornou um procedimento rotineiramente realizado para tratamento de pacientes com fibrilação atrial (FA). Fundamentado inicialmente no isolamento elétrico das veias pulmonares em pacientes com FA paroxística, subsequentes avanços no entendimento da fisiopatologia levaram a técnicas adicionais não só para obter melhores resultados, mas também para tratar pacientes com formas persistentes de arritmia, assim como pacientes com cardiopatia estrutural e insuficiência cardíaca.


Abstract More than 20 years since its initial use, catheter ablation has become a routinely performed procedure for the treatment of patients with atrial fibrillation (AF). Initially based on the electrical isolation of pulmonary veins in patients with paroxysmal AF, subsequent advances in the understanding of pathophysiology led to additional techniques not only to achieve better results, but also to treat patients with persistent forms of arrhythmia, as well as patients with structural heart disease and heart failure.


Assuntos
Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Recidiva , Resultado do Tratamento
9.
Rev. bras. cir. cardiovasc ; 35(6): 999-1002, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1143991

RESUMO

Abstract Minimally invasive surgical ablation is generally contraindicated in patients with atrial fibrillation and thrombosis of the left atrial appendage. We have treated three of these patients using an innovative technique based on a bilateral video-thoracoscopic approach, performing a continuous encircling lesion at the pulmonary veins outflow with radio-frequency ablation, simultaneously excluding the left atrial appendage. The postoperative course was uneventful, without neurologic events and all patients maintained a stable sinus rhythm at 1-year follow-up. This procedure represents a new mini-invasive method to treat persistent atrial fibrillation when partial thrombosis of the left atrial appendage contraindicates other ablation techniques.


Assuntos
Humanos , Fibrilação Atrial/cirurgia , Trombose/etiologia , Ablação por Cateter , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Toracoscopia , Resultado do Tratamento
10.
Rev. bras. cir. cardiovasc ; 35(5): 841-843, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | SES-SP, LILACS | ID: biblio-1137322

RESUMO

Abstract Cardiac rhythm disorders are common in many patients with cancer. The management of synchronous long-standing persistent atrial fibrillation and pulmonary lesions remains a serious surgical dilemma due to the lack of clinical data and surgical guidelines. To the best of our knowledge, this is the first described case of simultaneous thoracoscopic pulmonary segmentectomy and left atrial posterior wall and pulmonary vein isolation combined with left atrial appendage resection in a patient with early-stage primary lung cancer and long-standing persistent atrial fibrillation.


Assuntos
Humanos , Feminino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ablação por Cateter/métodos , Adenocarcinoma Mucinoso/cirurgia , Adenocarcinoma Mucinoso/complicações , Adenocarcinoma Mucinoso/diagnóstico por imagem , Pneumonectomia/métodos , Veias Pulmonares/cirurgia , Toracoscopia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Apêndice Atrial/cirurgia , Átrios do Coração/cirurgia , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico por imagem
12.
Arq. bras. cardiol ; 115(3): 528-535, out. 2020. tab, graf
Artigo em Português | LILACS, SES-SP | ID: biblio-1131326

RESUMO

Resumo Fundamento O isolamento elétrico das veias pulmonares é reconhecidamente base fundamental para o tratamento não farmacológico da fibrilação atrial (FA) e, portanto, tem sido recomendado como passo inicial na ablação de FA em todas as diretrizes. A técnica com balão de crioenergia, embora amplamente utilizada na América do Norte e Europa, ainda se encontra em fase inicial em muitos países em desenvolvimento, como o Brasil. Objetivo Avaliar o sucesso e a segurança da técnica de crioablação em nosso serviço, em pacientes com FA paroxística e persistente. Métodos Cento e oito pacientes consecutivos com FA sintomática e refratária ao tratamento farmacológico foram submetidos à crioablação para isolamento das veias pulmonares. Os pacientes foram separados em dois grupos, de acordo com a classificação convencional da FA paroxística (duração de até sete dias) e persistente (FA por mais de sete dias). Dados de recorrência e segurança do procedimento foram analisados respectivamente como desfechos primário e secundário. O nível de significância adotado foi de 5%. Resultados Cento e oito pacientes, com idade média de 58±13 anos, 84 do sexo masculino (77,8%), foram submetidos ao procedimento de crioablação de FA. Sessenta e cinco pacientes apresentavam FA paroxística (60,2%) e 43, FA persistente (39,2%). O tempo médio do procedimento foi de 96,5±29,3 minutos e o tempo médio de fluoroscopia foi de 29,6±11,1 minutos. Foram observadas cinco (4,6%) complicações, nenhuma fatal. Considerando a evolução após os 3 meses iniciais, foram observadas 21 recorrências (19,4%) em período de um ano de seguimento. As taxas de sobrevivência livre de recorrência nos grupos paroxístico e persistente foram de 89,2% e 67,4%, respectivamente. Conclusão A crioablação para isolamento elétrico das veias pulmonares é um método seguro e eficaz para tratamento da FA. Nossos resultados estão consoantes com demais estudos, que sugerem que a tecnologia pode ser utilizada como abordagem inicial, mesmo nos casos de FA persistente. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Electrical isolation of the pulmonary veins is recognized as the cornerstone of non-pharmacological treatment of Atrial Fibrillation (AF), and therefore, has been recommended as the first step in AF ablation according to all guidelines. Even though the cryoballoon technology is widely used in North America and Europe, this experience is still incipient in many developing countries such as Brazil. Objective To evaluate initial results regarding success and safety of the new technology in patients with persistent and paroxysmal AF. Methods One hundred and eight consecutive patients with symptomatic AF refractory to pharmacological treatment were submitted to cryoablation for isolation of the pulmonary veins. Patients were separated into two groups according to AF classification: persistent (AF for over one week); or paroxysmal (shorter episodes). Recurrence and procedural safety data were analyzed respectively as primary and secondary outcomes. The level of significance was 5%. Results One hundred and eight patients, with mean age 58±13 years, 84 males (77.8%), underwent cryoablation. Sixty-five patients had paroxysmal AF (60.2%) and 43 had persistent AF (39.2%). The mean time of the procedure was 96.5±29.3 minutes and the mean fluoroscopy time was 29.6±11.1 minutes. Five (4.6%) complications were observed, none fatal. Considering a blanking period of 3 months, 21 recurrences (19.4%) were observed in a one-year follow-up period. The recurrence-free survival rates of AF in the paroxysmal and persistent groups were 89.2% and 67.4%, respectively. Conclusion Cryoablation for electrical isolation of the pulmonary veins is a safe and effective method for the treatment of AF. Our results are consistent with other studies suggesting that this technology can be used as an initial technique even in cases of persistent AF.


Assuntos
Humanos , Masculino , Idoso , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Recidiva , Brasil , Resultado do Tratamento , Pessoa de Meia-Idade
13.
Rev. bras. cir. cardiovasc ; 35(4): 577-579, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137308

RESUMO

Abstract Early recognition and rapid and appropriate treatment of cardiac tamponade are mandatory to prevent the irreversible deterioration of cerebral perfusion and other important organs. In this study, cardiac tamponade was induced by inadvertent transseptal puncture, which was managed with pericardial drainage and surgical repair in a patient with symptomatic paroxysmal atrial fibrillation. Epicardial atrial fibrillation ablation and left atrial appendage amputation were also performed at the same time.


Assuntos
Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/diagnóstico por imagem , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Tamponamento Cardíaco/cirurgia , Resultado do Tratamento , Ablação por Cateter , Catéteres , Amputação Cirúrgica
14.
Rev. bras. cir. cardiovasc ; 35(3): 375-386, May-June 2020. tab
Artigo em Inglês | LILACS, SES-SP | ID: biblio-1137267

RESUMO

Abstract Medical management of atrial fibrillation can be complex, challenging and requiring time to prove its effectiveness; furthermore, the response can be refractory and inconsistent if the underlying pathology is not permanently addressed. Surgical ablation has become a key intervention, and since its first intervention in 1987 (the Cox-maze procedure), the technique has evolved from a conventional open method to a minimally invasive technique whilst retaining excellent outcomes. Furthermore, recent advances in the use of a hybrid approach have been established as satisfactory approach in managing atrial fibrillation with satisfactory outcomes. This literature review focuses on the evidence behind the surgical success in managing atrial fibrillation throughout the past, present and the future of these surgical interventions.


Assuntos
Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos
16.
Arq. bras. cardiol ; 114(6): 1015-1026, Jun., 2020. tab, graf
Artigo em Inglês, Português | LILACS, SES-SP | ID: biblio-1131238

RESUMO

Resumo Fundamento O uso da radiação ionizante em procedimentos médicos está associado a riscos significativos à saúde dos pacientes e da equipe de saúde. Objetivos Avaliar a segurança e a eficácia aguda da ablação por cateter para tratamento da fibrilação atrial (FA) e arritmias supraventriculares (SVTs), utilizando uma abordagem exclusivamente não fluoroscópica, guiada por eco intracardíaco (ICE) e mapeamento 3D. Métodos 95 pts (idade média 60 ± 18 anos, 61% do sexo masculino) programados para ablação de FA (69 pts, 45 FA paroxística e 24 FA persistente) ou SVTs (26 pts - 14 reentrada nodal, 6 Wolf-Parkinson-White [WPW], 5 flutter atrial direito [AD], 1 taquicardia atrial). Nove pacientes (9,5%) tinham marcapasso definitivo ou dispositivos de ressincronização com desfibrilador. Dois sistemas de mapeamento eletroanatômico foram utilizados - CARTO (65%) e NAVx (35%), bem como cateteres de ICE disponíveis - Acunav e ViewFlex. Resultados O isolamento das veias pulmonares (VPs), bem como todos os outros alvos que precisavam de ablação em ambos os átrios, foram alcançados e adequadamente visualizados. Não foram observados derrames pericárdicos, complicações trombóticas ou outras intercorrências nesta série. Punções transseptais difíceis (19 pacientes - 20%) foram realizadas sem fluoroscopia em todos os casos. Não foi utilizada fluoroscopia de backup, e nenhum vestuário de chumbo foi necessário. Avaliações detalhadas dos marcapassos após o procedimento não mostraram nenhum dano aos eletrodos, deslocamentos ou mudanças de limiar. Conclusões Uma estratégia de ablação por cateter sem uso de radiação para FA e outras arritmias atriais é segura e eficaz quando guiada pela utilização adequada do ICE e do mapeamento 3D. Diversos sítios em ambos os átrios podem ser alcançados e adequadamente ablacionados sem a necessidade de fluoroscopia de backup. Não foram observadas complicações. (Arq Bras Cardiol. 2020; 114(6):1015-1026)


Abstract Background The use of ionizing radiation in medical procedures is associated with significant health risks for patients and the health care team. Objectives Evaluate the safety and acute efficacy of ablation for atrial fibrillation (AF) and supraventricular arrhythmias (SVTs) using an exclusively non-fluoroscopic approach guided by intracardiac echo (ICE) and 3D-mapping. Methods 95 pts (mean age 60 ± 18 years, 61% male) scheduled for AF Ablation (69 pts, 45 paroxysmal AF and 24 persistent AF) or non-AF SVT (26 pts - 14 AV node reentry, 6 WPW, 5 right atrial (RA) flutters, 1 atrial tachycardia) underwent zero fluoro procedures. Nine patients (9.5%) had permanent pacemakers or defibrillator resynchronization (CRT-D) devices. Both CARTO (65%) and NAVx (35%) mapping systems were used, as well as Acunav and ViewFlex ICE catheters. Results Pulmonary vein isolation (PVI), as well as all other targets that needed ablation in both atria were reached and adequately visualized. No pericardial effusions, thrombotic complications or other difficulties were seen in these series. Difficult transseptal puncture (19 patients - 20%) was managed without fluoroscopy in all cases. No backup fluoroscopy was used, and no lead apparel was needed. Pacemaker interrogations after the procedure did not show any lead damage, dislocation, or threshold changes. Conclusions A radiation-free (fluoroless) catheter ablation strategy for AF and other atrial arrhythmias is acutely safe and effective when guided by adequate ICE and 3D-mapping utilization. Multiple different bi-atrial sites were reached and adequately ablated without the need for backup fluoroscopy. No complications were seen. (Arq Bras Cardiol. 2020; 114(6):1015-1026)


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Veias Pulmonares , Fibrilação Atrial/cirurgia , Taquicardia Supraventricular/cirurgia , Ablação por Cateter , Fluoroscopia , Resultado do Tratamento , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA