Three-year clinical outcomes of patients treated with everolimus-eluting bioresorbable vascular scaffolds: Final results of the ABSORB EXTEND trial
Costa, J. Ribamar Junior; Abizaid, Alexandre; Whitbourn, Robert; Jepson, Nigel; Steinwender, Clemens; Stuteville, Marrianne; Ediebah, Divine; Sudhir, Krishnankutty; Bartorelli, Antonio L; Serruys, Patrick W.
Afiliação
  • Costa, J. Ribamar Junior; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Abizaid, Alexandre; Instituto de Cardiologia Dante Pazzanese. São Paulo. BR
  • Whitbourn, Robert; St. Vincent's Hospital fitzroy. Vitória. AU
  • Jepson, Nigel; Prince Of Wales Hospital. Sydney. AU
  • Steinwender, Clemens; Allgemeines Krankenhaus Linz. Linz. AT
  • Stuteville, Marrianne; Abbott Vascular International. Diegem. BE
  • Ediebah, Divine; Abbott Vascular International. Diegem. BE
  • Sudhir, Krishnankutty; Abbott Vascular Inc. Santa Clara. US
  • Bartorelli, Antonio L; IRCCS University of Milan. Centro Cardiologico Monzino. Milão. IT
  • Serruys, Patrick W; Thoraxcenter Erasmus University Medical Center. Roterdão. NL
Catheter. cardiovasc. interv ; 93(1): 1-7, Jan. 2019. gráfico, tabela
Article em En | SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1024591
Biblioteca responsável: BR79.1
Localização: BR79.1
ABSTRACT

BACKGROUND:

There is still limited data on the very long term clinical outcomes after ABSORB BRS in daily practice. We sought to evaluate the 3 year-performance of the Absorb bioresorbable vascular scaffolds for the treatment of low/moderate complexity patients enrolled in the ABSORB EXTEND trial.

METHODS:

ABSORB EXTEND is a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and reference vessel diameter of 2.0-3.8 mm (as assessed by on-line QCA). To determine the independent predictors of MACE, a multivariable logistic regression model was built using a stepwise (forward/backward) procedure.

RESULTS:

Average population age was 61 years and 26.5% had diabetes. Most patients had single target lesion (92.4%). Adequate scaffold deployment (PSP) was achieved in 14.2% of the cases. At three years, the composite endpoints of MACE and ischemia-driven target vessel failure were 9.2% and 10.6%, respectively. The cumulative rate of ARC definite/probable thrombosis was 2.2%, with 1.2% of the cases occurring after the 1st year. Independent predictors of MACE were hypertension and the need for "bail out" stent.

CONCLUSION:

At three-year follow-up, the use of ABSORB in low/moderate complex PCI was associated with low and acceptable rates of major adverse clinical events, despite the infrequent use of the recommended contemporary scaffold deployment technique. However, scaffold thrombosis rate was higher than reported with current generation of metallic DES. (AU)