Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Radiat Prot Dosimetry ; 199(15-16): 1968-1972, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819306

RESUMEN

In proton therapy, most treatment planning systems (TPS) use a fixed relative biological effectiveness (RBE) of 1.1 all along the depth-dose profile. Innovative TPS are now investigated considering the variability of RBE with radiation quality. New TPS need an experimental verification in the quality assurance (QA) routine in clinics, but RBE data are usually obtained with radiobiological measurements that are time consuming and not suitable for daily QA. Microdosimetry is a useful tool based on physical measurements which can monitor the radiation quality. Several microdosimeters are available in different research institutions, which could potentially be used for the QA in TPS. In this study, the response functions of five detectors in the same 62-MeV proton Spread Out Bragg Peak is compared in terms of spectral distributions and their average values and microdosimetric RBE. Their different response function has been commented and must be considered in the clinical practice.


Asunto(s)
Terapia de Protones , Protones , Radiometría , Efectividad Biológica Relativa
2.
Phys Med Biol ; 67(16)2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35679848

RESUMEN

Objective.In the present hadrontherapy scenario, there is a growing interest in exploring the capabilities of different ion species other than protons and carbons. The possibility of using different ions paves the way for new radiotherapy approaches, such as the multi-ions treatment, where radiation could vary according to target volume, shape, depth and histologic characteristics of the tumor. For these reasons, in this paper, the study and understanding of biological-relevant quantities was extended for the case of4He ion.Approach.Geant4 Monte Carlo based algorithms for dose- and track-averaged LET (Linear Energy Transfer) calculations, were validated for4He ions and for the case of a mixed field characterised by the presence of secondary ions from both target and projectile fragmentation. The simulated dose and track averaged LETs were compared with the corresponding dose and frequency mean values of the lineal energy,yD¯andy¯F, derived from experimental microdosimetric spectra. Two microdosimetric experimental campaigns were carried out at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud of Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) using two different microdosimeters: the MicroPlus probe and the nano-TEPC (Tissue Equivalent Proportional Counter).Main results.A good agreement ofL¯dTotalandL¯tTotalwithy¯Dandy¯Texperimentally measured with both microdosimetric detectors MicroPlus and nano-TEPC in two configurations: full energy and modulated4He ion beam, was found.Significance.The results of this study certify the use of a very effective tool for the precise calculation of LET, given by a Monte Carlo approach which has the advantage of allowing detailed simulation and tracking of nuclear interactions, even in complex clinical scenarios.


Asunto(s)
Transferencia Lineal de Energía , Radiometría , Algoritmos , Iones , Método de Montecarlo , Protones , Radiometría/métodos
3.
Phys Med ; 89: 226-231, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34425513

RESUMEN

The aim of the NEPTUNE (Nuclear process-driven Enhancement of Proton Therapy UNravEled) project is to investigate in detail both the physical and radiobiological phenomena that could justify an increase of the proton-induced cytogenetic effects in cells irradiated in presence of an agent containing natural boron. In this work, a double-stage silicon telescope coupled to different boron converters was irradiated at the CATANA proton therapy facility (INFN-LNS) for studying the proton boron fusion and the neutron boron capture reactions by discriminating secondary particles from primary protons. Different boron targets were developed by depositing boric acid, enriched with a higher than 99% content of 10B or 11B, on a 50 µm thick PolyMethilMetacrylate (PMMA) substrate. The 10B target allows to evaluate the contribution of lithium and alpha particles produced by the boron neutron capture reaction triggered by secondary thermal neutrons, while the 11B target is exploited for studying the effect of the p + 11B → 3α nuclear reaction directly triggered by primary protons. Experimental results clearly show the presence of alpha particles from both the reactions. The silicon telescope is capable of discriminating, by means of the so-called "scatter plots", the contribution of alpha particles originated by thermal neutrons on 10B with respect to the ones produced by protons impinging on 11B. Although a reliable quantitative study of the alpha production rate has not been achieved yet, this work demonstrates that low energy and, therefore, high-LET particles from both the reactions can be measured.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Terapia de Protones , Boro , Neutrones , Protones
4.
Phys Med Biol ; 65(23): 235043, 2020 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-33263314

RESUMEN

We exploited the power of the Geant4 Monte Carlo toolkit to study and validate new approaches for the averaged linear energy transfer (LET) calculation in 62 MeV clinical proton beams. The definitions of the averaged LET dose and LET track were extended, so as to fully account for the contribution of secondary particles generated by target fragmentation, thereby leading to a more general formulation of the LET total. Moreover, in the proposed new strategies for the LET calculation, we minimised the dependencies in respect to the transport parameters adopted during the Monte Carlo simulations (such as the production cut of secondary particles, voxel size and the maximum steplength). The new proposed approach was compared against microdosimetric experimental spectra of clinical proton beams, acquired at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) from two different detectors: a mini-tissue equivalent proportional chamber (TEPC), developed at the Legnaro National Laboratories of the National Institute for Nuclear Physics (LNL-INFN) and a silicon-on-insulator (SOI) microdosimeter with 3D sensitive volumes developed by the Centre for Medical Radiation Physics of Wollongong University (CMRP-UoW). A significant increase of the LET in the entrance region of the spread out Bragg peak (SOBP) was observed, when the contribution of the generated secondary particles was included in the calculation. This was consistent with the experimental results obtained.


Asunto(s)
Algoritmos , Transferencia Lineal de Energía , Método de Montecarlo , Terapia de Protones , Dosis de Radiación , Humanos , Dosificación Radioterapéutica
5.
Phys Med Biol ; 65(24): 245018, 2020 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-33086208

RESUMEN

Proton beams are widely used worldwide to treat localized tumours, the lower entrance dose and no exit dose, thus sparing surrounding normal tissues, being the main advantage of this treatment modality compared to conventional photon techniques. Clinical proton beam therapy treatment planning is based on the use of a general relative biological effectiveness (RBE) of 1.1 along the whole beam penetration depth, without taking into account the documented increase in RBE at the end of the depth dose profile, in the Bragg peak and beyond. However, an inaccurate estimation of the RBE can cause both underdose or overdose, in particular it can cause the unfavourable situation of underdosing the tumour and overdosing the normal tissue just beyond the tumour, which limits the treatment success and increases the risk of complications. In view of a more precise dose delivery that takes into account the variation of RBE, experimental microdosimetry offers valuable tools for the quality assurance of LET or RBE-based treatment planning systems. The purpose of this work is to compare the response of two different microdosimetry systems: the mini-TEPC and the MicroPlus-Bridge detector. Microdosimetric spectra were measured across the 62 MeV spread out Bragg peak of CATANA with the mini-TEPC and with the Bridge microdosimeter. The frequency and dose distributions of lineal energy were compared and the different contributions to the spectra were analysed, discussing the effects of different site sizes and chord length distributions. The shape of the lineal energy distributions measured with the two detectors are markedly different, due to the different water-equivalent sizes of the sensitive volumes: 0.85 µm for the TEPC and 17.3 µm for the silicon detector. When the Loncol's biological weighting function is applied to calculate the microdosimetric assessment of the RBE, both detectors lead to results that are consistent with biological survival data for glioma U87 cells. Both the mini-TEPC and the MicroPlus-Bridge detector can be used to assess the RBE variation of a 62 MeV modulated proton beam along its penetration depth. The microdosimetric assessment of the RBE based on the Loncol's weighting function is in good agreement with radiobiological results when the 10% biological uncertainty is taken into account.


Asunto(s)
Terapia de Protones , Radiometría , Efectividad Biológica Relativa , Humanos , Silicio
6.
Phys Med ; 52: 113-121, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30139599

RESUMEN

PURPOSE: The aim of this paper is to investigate the limits of LET monitoring of therapeutic carbon ion beams with miniaturized microdosimetric detectors. METHODS: Four different miniaturized microdosimeters have been used at the 62 MeV/u 12C beam of INFN Southern National Laboratory (LNS) of Catania for this purpose, i.e. a mini-TEPC and a GEM-microdosimeter, both filled with propane gas, and a silicon and a diamond microdosimeter. The y-D (dose-mean lineal energy) values, measured at different depths in a PMMA phantom, have been compared withLET¯D (dose-mean LET) values in water, calculated at the same water-equivalent depth with a Monte Carlo simulation setup based on the GEANT4 toolkit. RESULTS: In these first measurements, no detector was found to be significantly better than the others as a LET monitor. The y-D relative standard deviation has been assessed to be 13% for all the detectors. On average, the ratio between y-D and LET¯D values is 0.9 ±â€¯0.3, spanning from 0.73 ±â€¯0.08 (in the proximal edge and Bragg peak region) to 1.1 ±â€¯0.3 at the distal edge. CONCLUSIONS: All the four microdosimeters are able to monitor the dose-mean LET with the 11% precision up to the distal edge. In the distal edge region, the ratio of y-D to LET¯D changes. Such variability is possibly due to a dependence of the detector response on depth, since the particle mean-path length inside the detectors can vary, especially in the distal edge region.


Asunto(s)
Radiometría/instrumentación , Calibración , Isótopos de Carbono/uso terapéutico , Simulación por Computador , Diseño de Equipo , Radioterapia de Iones Pesados/instrumentación , Miniaturización , Método de Montecarlo , Fantasmas de Imagen , Polimetil Metacrilato , Dosificación Radioterapéutica , Agua
7.
Radiat Prot Dosimetry ; 180(1-4): 157-161, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29087524

RESUMEN

The Italian National Centre for Oncological Hadrontherapy (CNAO) has been treating patients since 2011 with carbon-ion beams using the active-scanning modality. In such irradiation modality, the beam spot, which scans the treatment area, is characterised by very high particle-fluence rates (more than 105 s-1 mm-2). Moreover, the Bragg-peak is only ~1 mm-FWHM. Commercial tissue-equivalent proportional counters (TEPC), like the Far West Technologies LET-½, are large, hence they have limited capability to measure at high counting fluence rates. In this study we have used two home-made detectors, a mini-TEPC 0.81 mm2 in sensitive area and a silicon telescope 0.125 mm2 in sensitive area, to perform microdosimetric measurements in the therapeutic carbon-ion beam of CNAO. A monoenergetic carbon-ion beam of 189.5 ± 0.3 MeV/u scanning a 3 × 3 cm2 area has been used. Spectral differences are visible in the low y-value region, but the mean microdosimetric values, measured with the two detectors, result to be pretty consistent, as well as the microdosimetric spectra in the high y-value region.


Asunto(s)
Carbono/uso terapéutico , Instituciones de Salud , Microtecnología/métodos , Aceleradores de Partículas/instrumentación , Monitoreo de Radiación/instrumentación , Radioterapia/instrumentación , Humanos , Transferencia Lineal de Energía
8.
Appl Radiat Isot ; 106: 145-50, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26249744

RESUMEN

The reliability of Fricke gel dosimeters in form of layers for measurements aimed at the characterization of epithermal neutron beams has been studied. By means of dosimeters of different isotopic composition (standard, containing (10)B or prepared with heavy water) placed against the collimator exit, the spatial distribution of gamma and fast neutron doses and of thermal neutron fluence are attained. In order to investigate the accuracy of the results obtained with in-air measurements, suitable MC simulations have been developed and experimental measurements have been performed utilizing Fricke gel dosimeters, thermoluminescence detectors and activation foils. The studies were related to the epithermal beam designed for BNCT irradiations at the research reactor LVR-15 (Rez). The results of calculation and measurements have revealed good consistency of gamma dose and fast neutron 2D distributions obtained with gel dosimeters in form of layers. In contrast, noticeable modification of thermal neutron fluence is caused by the neutron moderation produced by the dosimeter material. Fricke gel dosimeters in thin cylinders, with diameter not greater than 3mm, have proved to give good results for thermal neutron profiling. For greater accuracy of all results, a better knowledge of the dependence of gel dosimeter sensitivity on radiation LET is needed.


Asunto(s)
Terapia por Captura de Neutrón/instrumentación , Dosificación Radioterapéutica , Modelos Teóricos , Método de Montecarlo
9.
Appl Radiat Isot ; 69(12): 1664-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21478028

RESUMEN

Neutron energy spectra at different emission angles, between 0° and 120° from the Be(p,xn) reaction generated by a beryllium thick-target bombarded with 5 MeV protons, have been measured at the Legnaro Laboratories (LNL) of the Italian National Institute for Nuclear Physics research (INFN). A new and quite compact recoil-proton spectrometer, based on a monolithic silicon telescope, coupled to a polyethylene converter, was efficiently used with respect to the traditional Time-of-Flight (TOF) technique. The measured distributions of recoil-protons were processed through an iterative unfolding algorithm in order to determine the neutron energy spectra at all the angles accounted for. The neutron energy spectrum measured at 0° resulted to be in good agreement with the only one so far available at the requested energy and measured years ago with TOF technique. Moreover, the results obtained at different emission angles resulted to be consistent with detailed past measurements performed at 4 MeV protons at the same angles by TOF techniques.

10.
Appl Radiat Isot ; 69(12): 1660-3, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21316253

RESUMEN

Some remarkable advances have been made in the last years on the SPES-BNCT project of the Istituto Nazionale di Fisica Nucleare (INFN) towards the development of the accelerator-driven thermal neutron beam facility at the Legnaro National Laboratories (LNL), aimed at the BNCT experimental treatment of extended skin melanoma. The compact neutron source will be produced via the (9)Be(p,xn) reactions using the 5 MeV, 30 mA beam driven by the RFQ accelerator, whose modules construction has been recently completed, into a thick beryllium target prototype already available. The Beam Shaping Assembly (BSA) final modeling, using both neutron converter and the new, detailed, Be(p,xn) neutron yield spectra at 5 MeV energy recently measured at the CN Van de Graaff accelerator at LNL, is summarized here.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Modelos Teóricos , Diseño de Equipo , Humanos , Melanoma/radioterapia , Neoplasias Cutáneas/radioterapia
11.
Radiat Prot Dosimetry ; 131(1): 7-14, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18782783

RESUMEN

Within the scope of CONRAD (A Coordinated Action for Radiation Dosimetry) Work Package 4 on Computational Dosimetry jointly collaborated with the other research actions on internal dosimetry, complex mixed radiation fields at workplaces and medical staff dosimetry. Besides these collaborative actions, WP4 promoted an international comparison on eight problems with their associated experimental data. A first set of three problems, the results of which are herewith summarised, dealt only with the expression of the stochastic uncertainties of the results: the analysis of the response function of a proton recoil telescope detector, the study of a Bonner sphere neutron spectrometer and the analysis of the neutron spectrum and dosimetric quantity H(p)(10) in a thermal neutron facility operated by IRSN Cadarache (the SIGMA facility). A second paper will summarise the results of the other five problems which dealt with the full uncertainty budget estimate. A third paper will present the results of a comparison on in vivo measurements of the (241)Am bone-seeker nuclide distributed in the knee. All the detailed papers will be presented in the WP4 Final Workshop Proceedings.


Asunto(s)
Radiometría , Radioterapia Asistida por Computador , Humanos , Modelos Teóricos , Neutrones , Protones , Radiometría/instrumentación , Radioterapia Asistida por Computador/instrumentación , Procesos Estocásticos
12.
Radiat Prot Dosimetry ; 126(1-4): 640-4, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17576652

RESUMEN

In-phantom dosimetry studies have been carried out at the thermal columns of a thermal- and a fast-nuclear reactor for investigating: (a) the spatial distribution of the gamma dose and the thermal neutron fluence and (b) the accuracy at which the boron concentration should be estimated in an explanted organ of a boron neutron capture therapy patient. The phantom was a cylinder (11 cm in diameter and 12 cm in height) of tissue-equivalent gel. Dose images were acquired with gel dosemeters across the axial section of the phantom. The thermal neutron fluence rate was measured with activation foils in a few positions of this phantom. Dose and fluence rate profiles were also calculated with Monte Carlo simulations. The trend of these profiles do not show significant differences for the thermal columns considered in this work.


Asunto(s)
Carga Corporal (Radioterapia) , Modelos Biológicos , Neutrones , Reactores Nucleares/instrumentación , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Simulación por Computador , Humanos , Fantasmas de Imagen , Dosis de Radiación , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Radiat Prot Dosimetry ; 126(1-4): 69-73, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17504745

RESUMEN

A new thermal neutron irradiation facility, devoted to carry out both dosimetric and radiobiological studies on boron carriers, which are being developed in the framework of INFN BNCT project, has been installed at the ENEA Casaccia TAPIRO research fast reactor. The thermal column, based on an original, hybrid, neutron spectrum shifter configuration, has been recently become operative. In spite of its low power (5 kW), the new facility is able to provide a high thermal neutron flux level, uniformly distributed inside the irradiation cavity, with a quite low gamma background. The main features and preliminary benchmark measurements of the Beam-shaping assembly are here presented and discussed.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Diseño Asistido por Computadora , Neutrones , Aceleradores de Partículas/instrumentación , Radiobiología/instrumentación , Investigación/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Calor , Italia , Integración de Sistemas
14.
Radiat Prot Dosimetry ; 118(2): 144-54, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16698968

RESUMEN

The QUADOS EU cost shared action conducted an intercomparison on the usage of numerical methods in radiation protection and dosimetry. The eight problems proposed were intended to test the usage of Monte Carlo and deterministic methods by assessing the accuracy with which the codes are applied and also the methods used to evaluate uncertainty in the answer gained through these methods. The overall objective was to spread good practice through the community and give users information on how to assess the uncertainties associated with their calculated results.


Asunto(s)
Neutrones , Radiometría/métodos , Teorema de Bayes , Europa (Continente) , Humanos , Modelos Estadísticos , Método de Montecarlo , Dosis de Radiación , Reproducibilidad de los Resultados , Dispersión de Radiación , Programas Informáticos
15.
Radiat Prot Dosimetry ; 118(2): 155-66, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16517568

RESUMEN

'QUADOS', a concerted action of the European Commission, has promoted an intercomparison aimed at evaluating the use of computational codes for dosimetry in radiation protection and medical physics. This intercomparison was open to all users of radiation transport codes. Eight problems were selected for their relevance to the radiation dosimetry community, five of which involved photon and proton transport. This paper focuses on a discussion of lessons learned from the participation in solving the photon and charged particle problems. The lessons learned from the participation in solving the neutron problems are presented in a companion paper (in this issue).


Asunto(s)
Electrones , Fotones , Radiometría/métodos , Angioplastia/métodos , Teorema de Bayes , Braquiterapia/métodos , Calibración , Europa (Continente) , Neoplasias del Ojo/radioterapia , Humanos , Modelos Estadísticos , Dosis de Radiación , Reproducibilidad de los Resultados , Dispersión de Radiación
16.
Radiat Prot Dosimetry ; 122(1-4): 387-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17251252

RESUMEN

The development of microdosimeters and particle telescopes is important for risk assessment in space and aviation applications. The charge collection properties of a monolithic particle telescope, suitable for both microdosimetry and fluence based approaches, were studied using an ion microprobe.


Asunto(s)
Microelectrodos , Óptica y Fotónica/instrumentación , Protección Radiológica/instrumentación , Radiometría/instrumentación , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Protección Radiológica/métodos , Radiometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Electricidad Estática
17.
Radiat Prot Dosimetry ; 115(1-4): 222-6, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16381716

RESUMEN

The realisation of the National Center of Hadrontherapy was funded by the Italian Government in 2002. The Centre will be built in the area of Pavia (Italy). The synchrotron designed in the framework of this programme will accelerate protons and carbon ions up to 250 MeV and 400 MeV u(-1), respectively. Some of the main aspects which were taken into account in the design of the acceleration system are the patient's safety and the beam control. From this point of view an important role is played by the beam dumps in the synchrotron ring and upstream of the extraction system. In particular, an horizontal and a vertical beam dump will be installed in the synchrotron ring: the former will be used for lowering the beam intensity and the latter for beam abortion. The dump at the extraction will absorb the particles during the mounting and the falling ramps of the synchrotron magnetic cycle, thus extracting only the flat top of the ion spill. Beam dumps can produce intense fields of secondary radiation (neutrons, charged light-hadrons and photons) and high rates of induced activity, since they can absorb the beam completely. Usually they have to be shielded to protect the electronics during machine operation and to attenuate the radiation dose below the limits imposed by the law when the personnel access to the synchrotron hall. The part of the shielding design of the beam dumps concerning with the acceleration of protons was made using Monte Carlo simulations with the FLUKA code. Both induced activity and secondary radiation were taken into account. The shields against secondary radiation produced by carbon ions were designed, referring only to secondary neutrons, taking double-differential distributions from the literature as sources for the FLUKA simulations. The induced activity from carbon ions interactions was estimated analytically, using the data generated by the EPAX 2 code. The dose-equivalent rates from the induced radionuclides were calculated at 1 m from the shielded dumps, taking into account the contribution of activated components of the synchrotron ring.


Asunto(s)
Diseño Asistido por Computadora , Arquitectura y Construcción de Instituciones de Salud/métodos , Aceleradores de Partículas/instrumentación , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación , Protección Radiológica/métodos , Sincrotrones/instrumentación , Simulación por Computador , Diseño de Equipo/métodos , Análisis de Falla de Equipo/métodos , Arquitectura y Construcción de Instituciones de Salud/instrumentación , Italia , Modelos Estadísticos , Método de Montecarlo , Protones , Dosis de Radiación , Medición de Riesgo/métodos , Factores de Riesgo
18.
Radiat Prot Dosimetry ; 115(1-4): 363-8, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16381747

RESUMEN

Neutrons can be produced with low-energy ion accelerators for many applications, such as the characterisation of neutron detectors, the irradiation of biological samples and the study of the radiation damage in electronic devices. Moreover, accelerator-based neutron sources are under development for boron neutron capture therapy (BNCT). Thin targets are used for generating monoenergetic neutrons, while thick targets are usually employed for producing more intense neutron fields. The associated photon field produced by the target nuclei may have a strong influence on the application under study. For instance, these photons can play a fundamental role in the design of an accelerator-based neutron source for BNCT. This work focuses on the measurement of the photon field associated with neutrons that are produced by 4.0-6.8 MeV protons striking both a thin 7LiF target (for generating monoenergetic neutrons) and a thick beryllium target. In both cases, very intense photon fields are generated with energy distribution extending up to several MeV.


Asunto(s)
Berilio/química , Berilio/efectos de la radiación , Fluoruros/química , Fluoruros/efectos de la radiación , Compuestos de Litio/química , Compuestos de Litio/efectos de la radiación , Neutrones , Aceleradores de Partículas , Fotones , Relación Dosis-Respuesta en la Radiación , Dosis de Radiación , Radiometría/métodos
19.
Radiat Prot Dosimetry ; 115(1-4): 465-9, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16381768

RESUMEN

The CERN Superconducting Proton Linac (SPL) is expected to provide a 2.2 GeV, 4 MW proton beam to feed facilities such as, for example, a neutrino factory or a neutrino superbeam. Material activation in such facilities is an important aspect that has to be taken into account at an early stage in designing it. In particular, the choice of the target has consequences on the induced radioactivity and dose rates in the target station and its surroundings. In the present work, the radiological aspects of a stationary target made up of tantalum pellets are compared with those of a free-surface jet of mercury. An estimation of the hadronic inelastic interactions and the production of residual nuclei in the target, the two concentric magnetic horns, the decay tunnel, the surrounding rock and a downstream dump were performed for both targets using the Monte Carlo code FLUKA. The aim was to assess the dose-equivalent rate that is to be expected during maintenance work and to evaluate the amount of residual radioactivity, which will have to be disposed of after the facility has ceased operation. The problem of after-heat in the tantalum target and the consequences of raising the proton beam energy from 2.2 to 4 GeV were also investigated.


Asunto(s)
Arquitectura y Construcción de Instituciones de Salud/métodos , Exposición Profesional/análisis , Aceleradores de Partículas/instrumentación , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación , Medición de Riesgo/métodos , Contaminantes Radiactivos del Agua/análisis , Simulación por Computador , Diseño Asistido por Computadora , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Modelos Teóricos , Neutrones , Protones , Dosis de Radiación , Protección Radiológica/métodos , Factores de Riesgo
20.
Radiat Prot Dosimetry ; 110(1-4): 631-6, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15353721

RESUMEN

A method has been developed, based on thermoluminescent dosemeters (TLD), aimed at measuring the absorbed dose in tissue-equivalent phantoms exposed to thermal or epithermal neutrons, separating the contributions of various secondary radiation generated by neutrons. The proposed method takes advantage of the very low sensitivity of CaF2:Tm (TLD-300) to low energy neutrons and to the different responses to thermal neutrons of LiF:Mg,Ti dosemeters with different 6Li percentage (TLD-100, TLD-700, TLD-600). The comparison of the results with those obtained by means of gel dosemeters and activation foils has confirmed the reliability of the method. The experimental modalities allowing reliable results have been studied. The glow curves of TLD-300 after gamma or neutron irradiation have been compared; moreover, both internal irradiation effect and energy dependence have been investigated. For TLD-600, TLD-100 and TLD-700, the suitable fluence limits have been determined in order to avoid radiation damage and loss of linearity.


Asunto(s)
Terapia por Captura de Neutrón de Boro/instrumentación , Rayos gamma/uso terapéutico , Neutrones/uso terapéutico , Protección Radiológica/instrumentación , Planificación de la Radioterapia Asistida por Computador/instrumentación , Medición de Riesgo/métodos , Dosimetría Termoluminiscente/instrumentación , Carga Corporal (Radioterapia) , Terapia por Captura de Neutrón de Boro/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Miniaturización , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Dosimetría Termoluminiscente/métodos , Transductores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA