Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Cancers (Basel) ; 16(8)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38672601

RESUMEN

BACKGROUND: The reproducibility of radiomics features extracted from CT and MRI examinations depends on several physiological and technical factors. The aim was to evaluate the impact of contrast agent timing on the stability of radiomics features using dynamic contrast-enhanced perfusion CT (dceCT) or MRI (dceMRI) in prostate and lung cancers. METHODS: Radiomics features were extracted from dceCT or dceMRI images in patients with biopsy-proven peripheral prostate cancer (pzPC) or biopsy-proven non-small cell lung cancer (NSCLC), respectively. Features that showed significant differences between contrast phases were identified using linear mixed models. An L2-penalized logistic regression classifier was used to predict class labels for pzPC and unaffected prostate regions-of-interest (ROIs). RESULTS: Nine pzPC and 28 NSCLC patients, who were imaged with dceCT and/or dceMRI, were included in this study. After normalizing for individual enhancement patterns by defining seven individual phases based on a reference vessel, 19, 467 and 128 out of 1204 CT features showed significant temporal dynamics in healthy prostate parenchyma, prostate tumors and lung tumors, respectively. CT radiomics-based classification accuracy of healthy and tumor ROIs was highly dependent on contrast agent phase. For dceMRI, 899 and 1027 out of 1118 features were significantly dependent on time after contrast agent injection for prostate and lung tumors. CONCLUSIONS: CT and MRI radiomics features in both prostate and lung tumors are significantly affected by interindividual differences in contrast agent dynamics.

2.
EClinicalMedicine ; 65: 102267, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37876998

RESUMEN

Background: Ultra-low-dose CT (ULDCT) examinations of the chest at only twice the radiation dose of a chest X-ray (CXR) now offer a valuable imaging alternative to CXR. This trial prospectively compares ULDCT and CXR for the detection rate of diagnoses and their clinical relevance in a low-prevalence cohort of non-traumatic emergency department patients. Methods: In this prospective crossover cohort trial, 294 non-traumatic emergency department patients with a clinically indicated CXR were included between May 2nd and November 26th of 2019 (www.clinicaltrials.gov: NCT03922516). All participants received both CXR and ULDCT, and were randomized into two arms with inverse reporting order. The detection rate of CXR was calculated from 'arm CXR' (n = 147; CXR first), and of ULDCT from 'arm ULDCT' (n = 147; ULDCT first). Additional information reported by the second exam in each arm was documented. From all available clinical and imaging data, expert radiologists and emergency physicians built a compound reference standard, including radiologically undetectable diagnoses, and assigned each finding to one of five clinical relevance categories for the respective patient. Findings: Detection rates for main diagnoses by CXR and ULDCT (mean effective dose: 0.22 mSv) were 9.1% (CI [5.2, 15.5]; 11/121) and 20.1% (CI [14.2, 27.7]; 27/134; P = 0.016), respectively. As an additional imaging modality, ULDCT added 9.1% (CI [5.2, 15.5]; 11/121) of main diagnoses to prior CXRs, whereas CXRs did not add a single main diagnosis (0/134; P < 0.001). Notably, ULDCT also offered higher detection rates than CXR for all other clinical relevance categories, including findings clinically irrelevant for the respective emergency department visit with 78.5% (CI [74.0, 82.5]; 278/354) vs. 16.2% (CI [12.7, 20.3]; 58/359) as a primary modality and 68.2% (CI [63.3, 72.8]; 245/359) vs. 2.5% (CI [1.3, 4.7]; 9/354) as an additional imaging modality. Interpretation: In non-traumatic emergency department patients, ULDCT of the chest offered more than twice the detection rate for main diagnoses compared to CXR. Funding: The Department of Biomedical Imaging and Image-guided Therapy of Medical University of Vienna received funding from Siemens Healthineers (Erlangen, Germany) to employ two research assistants for one year.

3.
JTCVS Open ; 10: 62-72, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36004247

RESUMEN

Objectives: The ratio of pulmonary artery (PA) and ascending aorta (AA) diameters has recently been shown to be a useful indicator for disease severity and predictor of outcome in patients with pulmonary hypertension and heart failure. This study aimed at evaluating the applicability of this ratio for perioperative risk assessment of patients with chronic thromboembolic pulmonary hypertension undergoing pulmonary endarterectomy. Methods: In this retrospective cohort study on 149 patients undergoing pulmonary endarterectomy between 2013 and 2020, the preoperative PA to AA ratio was analyzed on axial computed tomography. Variables of pulmonary hemodynamic status were assessed during preoperative right heart catheterization and postoperative Swan-Ganz catheter measurements. Perioperative survival was analyzed by Kaplan-Meier method and log-rank tests. Results: Preoperative computed tomography measurements showed a median AA diameter of 31 mm (range, 19-47 mm), and a median PA diameter of 36 mm (range, 25-55 mm). The calculated median PA to AA ratio was 1.13 (range, 0.79-1.80). PA to AA ratio correlated positively with PA pressure (systolic, r = 0.352 [P < .001]; diastolic, r = 0.406 [P < .001]; mean, r = 0.318 [P < .001]) and inversely with age (r = -0.484 [P < .001]). Univariable Cox regression analysis identified PA diameter (P = .008) as a preoperative parameter predictive of survival. There was a significant difference (log-rank P = .037) in 30-day survival probability for patients with lower PA to AA ratios (<1.136; survival probability, 97.4%) compared with patients with higher ratios (>1.136; survival probability, 88.9%). Conclusions: PA to AA ratio shows a correlation with other variables associated with pulmonary hypertension. In addition, patients with higher PA to AA ratios have lower survival probabilities after PEA. Further analysis of PA to AA ratio on the selection of chronic thromboembolic pulmonary hypertension for different treatment modalities-pulmonary endarterectomy, medical therapy, and or balloon pulmonary angioplasty-is warranted.

4.
Front Oncol ; 11: 637804, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33889546

RESUMEN

Background: Immune checkpoint inhibitor efficacy in advanced cancer patients remains difficult to predict. Imaging is the only technique available that can non-invasively provide whole body information of a patient's response to treatment. We hypothesize that quantitative whole-body prognostic information can be extracted by leveraging artificial intelligence (AI) for treatment monitoring, superior and complementary to the current response evaluation methods. Methods: To test this, a cohort of 74 stage-IV urothelial cancer patients (37 in the discovery set, 37 in the independent test, 1087 CTs), who received anti-PD1 or anti-PDL1 were retrospectively collected. We designed an AI system [named prognostic AI-monitor (PAM)] able to identify morphological changes in chest and abdominal CT scans acquired during follow-up, and link them to survival. Results: Our findings showed significant performance of PAM in the independent test set to predict 1-year overall survival from the date of image acquisition, with an average area under the curve (AUC) of 0.73 (p < 0.001) for abdominal imaging, and 0.67 AUC (p < 0.001) for chest imaging. Subanalysis revealed higher accuracy of abdominal imaging around and in the first 6 months of treatment, reaching an AUC of 0.82 (p < 0.001). Similar accuracy was found by chest imaging, 5-11 months after start of treatment. Univariate comparison with current monitoring methods (laboratory results and radiological assessments) revealed higher or similar prognostic performance. In multivariate analysis, PAM remained significant against all other methods (p < 0.001), suggesting its complementary value in current clinical settings. Conclusions: Our study demonstrates that a comprehensive AI-based method such as PAM, can provide prognostic information in advanced urothelial cancer patients receiving immunotherapy, leveraging morphological changes not only in tumor lesions, but also tumor spread, and side-effects. Further investigations should focus beyond anatomical imaging. Prospective studies are warranted to test and validate our findings.

5.
PLoS One ; 15(2): e0228376, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32023294

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the impact of a 150kV spectral filtration chest imaging protocol (Sn150kVp) combined with advanced modeled iterative reconstruction (ADMIRE) on radiation dose and image quality in patients after lung-transplantation. METHODS: This study included 102 patients who had unenhanced chest-CT examinations available on both, a second-generation dual-source CT (DSCT) using standard protocol (100kVp, filtered-back-projection) and, on a third-generation DSCT using Sn150kVp protocol with ADMIRE. Signal-to-noise-ratio (SNR) was measured in 6 standardized regions. A 5-point Likert scale was used to evaluate subjective image quality. Radiation metrics were compared. RESULTS: The mean time interval between the two acquisitions was 1.1±0.7 years. Mean-volume-CT-dose-index, dose-length-product and effective dose were significantly lower for Sn150kVp protocol (2.1±0.5mGy;72.6±16.9mGy*cm;1.3±0.3mSv) compared to 100kVp protocol (6.2±1.8mGy;203.6±55.6mGy*cm;3.7±1.0mSv) (p<0.001), equaling a 65% dose reduction. All studies were considered of diagnostic quality. SNR measured in lung tissue, air inside trachea, vertebral body and air outside the body was significantly higher in 100kVp protocol compared to Sn150kVp protocol (12.5±2.7vs.9.6±1.5;17.4±3.6vs.11.8±1.8;0.7±0.3vs.0.4±0.2;25.2±6.9vs.14.9±3.3;p<0.001). SNR measured in muscle tissue was significantly higher in Sn150kVp protocol (3.2±0.9vs.2.6±1.0;p<0.001). For SNR measured in descending aorta there was a trend towards higher values for Sn150kVp protocol (2.8±0.6 vs. 2.7±0.9;p = 0.3). Overall SNR was significantly higher in 100kVp protocol (5.0±4.0vs.4.0±4.0;p<0.001). On subjective analysis both protocols achieved a median Likert rating of 1 (25th-75th-percentile:1-1;p = 0.122). Interobserver agreement was good (intraclass correlation coefficient = 0.73). CONCLUSIONS: Combined use of 150kVp tin-filtered chest CT protocol with ADMIRE allows for significant dose reduction while maintaining highly diagnostic image quality in the follow up after lung transplantation when compared to a standard chest CT protocol using filtered back projection.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Trasplante de Pulmón/métodos , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Femenino , Humanos , Enfermedades Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Estaño
6.
World J Urol ; 38(11): 2971-2979, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31993735

RESUMEN

PURPOSE: To assess a novel low-dose CT-protocol, combining a 150 kV spectral filtration unenhanced protocol (Sn150 kVp) and a stone-targeted dual-energy CT (DECT) in patients with urolithiasis. METHODS: 232 (151 male, 49 ± 16.4 years) patients with urolithiasis received a low-dose non-contrast enhanced CT (NCCT) for suspected urinary stones either on a third-generation dual-source CT system (DSCT) using Sn150 kVp (n = 116, group 1), or on a second-generation DSCT (n = 116 group 2) using single energy (SE) 120 kVp. For group 1, a subsequent dual-energy CT (DECT) with a short stone-targeted scan range was performed. Objective and subjective image qualities were assessed. Radiation metrics were compared. RESULTS: 534 stones (group 1: n = 242 stones; group 2: n = 292 stones) were found. In group 1, all 215 stones within the stone-targeted DECT-scan range were identified. DE analysis was able to distinguish between UA and non-UA calculi in all collected stones. 11 calculi (5.12%) were labeled as uric acid (UA) while 204 (94.88%) were labeled as non-UA calculi. There was no significant difference in overall Signal-to-noise-ratio between group 1 and group 2 (p = 0.819). On subjective analysis both protocols achieved a median Likert rating of 2 (p = 0.171). Mean effective dose was significantly lower for combined Sn150 kVp and stone-targeted DECT (3.34 ± 1.84 mSv) compared to single energy 120 kVp NCCT (4.45 ± 2.89 mSv) (p < 0.001), equaling a 24.9% dose reduction. CONCLUSION: The evaluated novel low-dose stone composition protocol allows substantial radiation dose reduction with consistent high diagnostic image quality.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Cálculos Urinarios/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos
7.
PLoS One ; 14(12): e0225673, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31856177

RESUMEN

PURPOSE: Advanced forms of prostate cancer (PCa) radiotherapy with either external beam therapy or brachytherapy delivery techniques aim for a focal boost and thus require accurate lesion localization and lesion segmentation for subsequent treatment planning. This study prospectively evaluated dynamic contrast-enhanced computed tomography (DCE-CT) for the detection of prostate cancer lesions in the peripheral zone (PZ) using qualitative and quantitative image analysis compared to multiparametric magnet resonance imaging (mpMRI) of the prostate. METHODS: With local ethics committee approval, 14 patients (mean age, 67 years; range, 57-78 years; PSA, mean 8.1 ng/ml; range, 3.5-26.0) underwent DCE-CT, as well as mpMRI of the prostate, including standard T2, diffusion-weighted imaging (DWI), and DCE-MRI sequences followed by transrectal in-bore MRI-guided prostate biopsy. Maximum intensity projections (MIP) and DCE-CT perfusion parameters (CTP) were compared between healthy and malignant tissue. Two radiologists independently rated image quality and the tumor lesion delineation quality of PCa using a five-point ordinal scale. MIP and CTP were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. RESULTS: The PCa detection rate ranged between 57 to 79% for the two readers for DCE-CT and was 92% for DCE-MRI. DCE-CT perfusion parameters in PCa tissue in the PZ were significantly different compared to regular prostate tissue and benign lesions. Image quality and lesion visibility were comparable between DCE-CT and DCE-MRI (VGC: AUC 0.612 and 0.651, p>0.05). CONCLUSION: Our preliminary results suggest that it is feasible to use DCE-CT for identification and visualization, and subsequent segmentation for focal radiotherapy approaches to PCa.


Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Imagen de Perfusión/métodos , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Anciano , Biopsia con Aguja Gruesa , Medios de Contraste/administración & dosificación , Imagen de Difusión por Resonancia Magnética , Estudios de Factibilidad , Humanos , Biopsia Guiada por Imagen , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Prueba de Estudio Conceptual , Estudios Prospectivos , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosis de Radiación
8.
Eur Radiol ; 29(7): 3617-3625, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30888484

RESUMEN

OBJECTIVES: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC). METHODS: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient. RESULTS: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement. CONCLUSION: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC. KEY POINTS: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.


Asunto(s)
Algoritmos , Carcinoma Ductal Pancreático/diagnóstico , Procesamiento de Imagen Asistido por Computador/métodos , Páncreas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Realidad Virtual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
9.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-29881885

RESUMEN

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Artefactos , Metales/química , Interpretación de Imagen Radiográfica Asistida por Computador , Titanio/química , Cerámica/química , Aleaciones de Cromo/química , Materiales Biocompatibles Revestidos/química , Simulación por Computador , Humanos , Fantasmas de Imagen , Prótesis e Implantes , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
10.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29761359

RESUMEN

OBJECTIVES: To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC). METHODS: A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA. RESULTS: Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification. CONCLUSIONS: EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS: • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Anciano , Algoritmos , Análisis de Varianza , Colonografía Tomográfica Computarizada/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Estudios Retrospectivos , Sensibilidad y Especificidad
11.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29404770

RESUMEN

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Calcio , Femenino , Filtración/métodos , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Estaño
12.
Int J Cardiovasc Imaging ; 33(9): 1425-1431, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28342038

RESUMEN

The purpose of the current study is to investigate whether breast cancer survivors after radiation therapy have a higher burden of coronary artery calcium as a potential surrogate of radiation-induced accelerated coronary artery disease. 333 patients were included. 54 patients underwent chest CT ≥ 6 months after the start of radiation therapy (radiation therapy group), while 279 patients had a CT scan either prior to or without undergoing radiation therapy (RT). Coronary artery calcium was quantified from CT by applying a threshold-based automated algorithm. Mean age at diagnosis was similar (p = 0.771) between RT (57.4 ± 13.1 years) and NoRT (58.0 ± 11.9 years). Median time between radiation therapy and CT was 2 years. The groups showed no significant differences in race, smoking history, cancer laterality, or cancer stage. 39 (72.2%) of RT patients had a coronary artery calcium score of 0, compared to 201 (72.0%) in patients without radiation therapy. Median coronary artery calcium burden for both groups was not significantly different (p = 0.982), nor when comparing patients who underwent left- versus right-sided radiation therapy (p = 0.453). When adjusting for the time between diagnosis and CT, radiation therapy patients had a significantly lower risk of a positive coronary artery calcium score. In conclusion, breast cancer survivors after radiation therapy are not more likely to show coronary artery calcium on follow-up CT imaging. Our results thus do not support radiation-induced accelerated coronary artery disease as an explanation for higher rates of heart disease in this group.


Asunto(s)
Neoplasias de la Mama/radioterapia , Supervivientes de Cáncer , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Enfermedad de la Arteria Coronaria/etiología , Vasos Coronarios/efectos de la radiación , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Radioterapia/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Calcificación Vascular/etiología
13.
Am J Cardiol ; 119(8): 1156-1161, 2017 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-28233536

RESUMEN

The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to-intermediate probability of coronary artery disease who underwent either third-generation dual-source cCTA using prospectively electrocardiography-triggered high-pitch spiral acquisition (n = 70) (group 1) or retrospective electrocardiography-gated cCTA on a 64-slice CT system (n = 70) (group 2). Contrast-to-noise and signal-to-noise ratios were measured within the aorta and coronary arteries. Subjective IQ was assessed using a 5-point Likert scale. Effective dose was estimated using specific conversion factors. The contrast-to-noise ratio of group 1 was significantly higher than group 2 at all levels (all p <0.001). Signal-to-noise ratio of group 1 was also significantly higher than group 2 (p <0.05), except for the distal left circumflex artery. Subjective IQ for group 1 was rated significantly better than for group 2 (median score [25th to 75th percentile]: 1 [1 to 2] vs 2 [2 to 3]; p <0.001). The median effective dose was 1.55 mSv (1.09 to 1.88) in group 1 versus 12.29 mSv (11.63 to 14.36) in group 2 (p <0.001) which corresponds to a mean radiation dose reduction of 87.4%. In conclusion, implementation of third-generation dual-source CT system for cCTA leads to improved IQ with significant radiation dose savings.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Angiografía Coronaria/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Electrocardiografía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
14.
Eur J Radiol ; 84(12): 2393-400, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26454742

RESUMEN

Dual energy computed tomography (DECT) has proven its clinical usefulness for improved tissue characterization within the past years. In thoracic oncology, DECT can be used to differentiate between benign and malignant pulmonary nodules and masses. In patients with known lung cancer, DECT can add incremental functional information to staging scans, therapeutic response evaluation, as well as to the assessment of lung function. This review aims to give an overview on the current clinical utilities of DECT of the chest, its multiple post-processing applications and dose saving options. Furthermore, this review highlights promising applications of DECT that merit implementation in future clinical routine.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/patología , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Estadificación de Neoplasias
15.
Exp Ther Med ; 9(6): 2281-2284, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26136974

RESUMEN

The reliable exclusion of a pulmonary embolism (PE) in hemodynamically stable patients remains a challenge. The European Society of Cardiology guidelines for PE diagnosis published in 2008 and updated in 2014 recommend a low-threshold computed tomography (CT) indication for patients with a high probability of pulmonary embolism or those with elevated levels of D-dimers. Certain elements of the recommendations are controversial, while others, including the evaluation of the risk factors for PE, are considered only in individual cases. In the present study, various risk factors, including obesity, smoking, contraceptive use, immobility level, history of malignant disease and thrombophilia and the factors of familial predisposition, deep vein thrombosis (DVT)/PE-history, long-distance flying <1 week and surgery <4 weeks previously, were retrospectively examined in 492 patients with a suspected PE. The data demonstrated a significant risk of PE with contraceptive use, a history of DVT/PE and thrombophilia. The immobility level, surgery <4 weeks and long-distance flying <1 week previously, as well as family history, malignant disease, obesity and smoking, were not observed to be associated with a significantly higher risk of PE. Contraceptive use and thrombophilia, in addition to a history of DVT/PE, each appear to have a significant predictive value in the context of PE risk stratification. Therefore, patients with a suspected PE, who additionally present with at least one of the aforementioned risk factors, should undergo further diagnostic steps for PE risk stratification, including a low-threshold CT examination, even in the absence of elevated D-dimers.

16.
In Vivo ; 29(2): 269-72, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25792656

RESUMEN

AIM: The European Society of Cardiology guidelines for pulmonary embolism (PE) published in 2008 and updated in 2014 recommend a risk stratification including risk scores like Wells and the Geneva score. The utility and practicability of these scores are controversially discussed. Recently, in a trauma cohort and in spinal surgery patients, no correlation between Wells Score and PE diagnosis was found. The aim of the study was the evaluation of Wells and Geneva scores in patients presenting with chest pain, dyspnoea or syncope in an emergency department. PATIENTS AND METHODS: We retrospectively examined 326 patients suspected of PE, including assessment, according to Wells and Geneva scores. RESULTS: PE was detected in 13.5 %. The average Wells score was 1.0, the average Geneva score 3.9. The receiver operating characteristic (ROC) curve analyses showed for both scores a high significant area under the curve (Wells score 0.68; Geneva score 0.64). The association between the scores and the diagnosis of PE was calculated with logistic regression analysis and showed high significant odds ratios (OR) for both scores (Wells score 1.38; Geneva score 1.24). There was no significant difference between the area under the curve (AUC) of Wells score and Geneva score. CONCLUSION: The utility of Wells and Geneva scores for the evaluation of patients suspected of PE in an emergency patient cohort.


Asunto(s)
Embolia Pulmonar/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Presión Sanguínea , Servicio de Urgencia en Hospital , Femenino , Productos de Degradación de Fibrina-Fibrinógeno , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Embolia Pulmonar/sangre , Embolia Pulmonar/terapia , Curva ROC , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
17.
J Thorac Oncol ; 10(2): 237-49, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25611226

RESUMEN

Modern imaging techniques that can provide functional information on tumor vascularization, metabolic activity, or cellularity have seen significant improvements over the past decade. However, most of these techniques are currently not broadly utilized neither in clinical trials nor in clinical routine, although there is a large agreement on the fact that conventional approaches for therapy response assessment such as Response Evaluation Criteria in Solid Tumors or World Health Organization criteria-that exclusively focus on the change in tumor size-are of less value for response assessment in modern thoracic oncology. The aim of this article comprises two parts: a short review of the most promising state-of-the-art imaging techniques that have the potential to play a larger role in thoracic oncology within the near future followed by a meeting report including recommendations of an interdisciplinary expert panel that discussed the potential of the different techniques during the Dresden 2013 Post World Congress of Lung Cancer (WCLC)--International Association for the Study of Lung Cancer (IASLC) meeting. It is intended to provide a comprehensive summary about ongoing trends and future perspectives on functional imaging in thoracic oncology.


Asunto(s)
Neoplasias Pulmonares/diagnóstico , Diagnóstico por Imagen , Humanos , Vigilancia Inmunológica , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/inmunología , Neoplasias Pulmonares/patología , Estadificación de Neoplasias , Radiografía
18.
Acad Radiol ; 21(4): 514-22, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24594421

RESUMEN

RATIONALE AND OBJECTIVES: To compare in dual-energy CT (DECT) conventionally reconstructed polyenergetic images (PEI) at 120 kVp to virtual monoenergetic images (MEI) at different kiloelectron volt (keV) levels for evaluation of liver and gastrointestinal stromal tumor (GIST) hepatic metastases with regard to objective (IQob) and subjective image quality (IQsub) assessed by two readers of varying experience. Image quality was correlated to patient size and compared between PEI and MEI. MATERIALS AND METHODS: From 50 examinations of 17 GIST patients (12 with hepatic metastases) undergoing abdominal dual-source DECT for staging, therapy monitoring or follow-up, PEI and nine MEI in 10-keV intervals from 40 to 120 keV were reconstructed. Liver contrast-to-noise ratios (CNR) and metastasis-to-liver ratios were calculated. MEI reconstructions with the highest IQob were compared to PEI for IQsub by one experienced reader (ER) and one inexperienced reader (IR). Patients' diameters were correlated to IQob and IQsub ratings. RESULTS: MEI at 70 keV had the highest IQob with equal liver CNR and metastasis-to-liver ratio compared to PEI. The ER rated 70-keV MEI and PEI equally high (median 4), whereas the IR rated IQsub best in 70-keV MEI (median 5). Unlike in PEI, IQsub ratings in 70-keV MEI were not correlated to patient size. CONCLUSIONS: MEI at 70 keV provided an IQob equivalent to PEI. Regarding the IR, IQsub was improved in 70-keV MEI compared to PEI and less dependent on patient size. Therefore, IRs might improve their diagnostic confidence in the assessment of hepatic GIST metastases by evaluating MEI reconstructions at 70 keV.


Asunto(s)
Tumores del Estroma Gastrointestinal/diagnóstico , Tumores del Estroma Gastrointestinal/secundario , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Competencia Clínica , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Dosis de Radiación , Protección Radiológica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
19.
Radiology ; 270(2): 387-93, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24471388

RESUMEN

PURPOSE: To investigate in vitro and in vivo the use of image-based and raw data-based iterative reconstruction algorithms for quantification of coronary artery calcium by using the Agatston score and subsequent cardiac risk stratification. MATERIALS AND METHODS: In vitro data were obtained by using a moving anthropomorphic cardiac phantom containing calcium inserts of different concentrations and sizes. With institutional review board approval and HIPAA compliance, coronary calcium imaging data of 110 consecutive patients (mean age ± standard deviation, 58.2 years ± 9.8; 48 men) were reconstructed with filtered back projection (FBP), iterative reconstruction in image space (IRIS), and sinogram-affirmed iterative reconstruction (SAFIRE). Image noise was measured and the Agatston score was obtained for all reconstructions. Assignment to Agatston scores and percentile-based cardiac risk categories was compared. Statistical analysis included the Cohen κ coefficient and Friedman and Wilcoxon testing. RESULTS: In vitro, mean Agatston scores ± standard deviation for FBP (638.9 ± 9.6), IRIS (622.7 ± 15.2), and SAFIRE (631.4 ± 17.6) were comparable (P = .30). The smallest phantom calcifications were more frequently detected when iterative reconstruction techniques were used. The Agatston scores in the patient cohort were not significantly different among FBP, IRIS, and SAFIRE in paired comparisons (median Agatston score [25th and 75th percentiles]: 76.0 [20.6, 243.9], 76.4 [22, 249.3], and 75.7 [21.5, 49.1], respectively; P = .20 each). Comparison of categorization based on Agatston score percentiles showed excellent agreement for both IRIS and SAFIRE with FBP (κ = 0.975 [0.942-1.00] and κ = 0.963 [0.922-1.00], respectively). The mean effective dose was 1.02 mSv ± 0.51. Mean image noise was significantly (P < .001) higher with FBP than that with iterative reconstructions. CONCLUSION: In comparison with FBP, iterative reconstruction techniques do not have a profound effect on the reproducible quantification of coronary calcium according to Agatston score and subsequent cardiac risk classification, although risk reclassification may occur in a small subset of subjects.


Asunto(s)
Algoritmos , Calcinosis/diagnóstico por imagen , Enfermedad Coronaria/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Medición de Riesgo
20.
Eur Radiol ; 24(2): 519-26, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24192980

RESUMEN

OBJECTIVES: This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). METHODS: cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFVM segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFVA calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. RESULTS: The final EFVA (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). CONCLUSIONS: Automated EFVA quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. KEY POINTS: • Manual epicardial fat volume quantification correlates with risk factors but is time-consuming. • The novel software prototype automates measurement of epicardial fat volume with good accuracy. • This novel approach is less time-consuming and could be incorporated into clinical workflow.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Pericardio/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Diseño de Software
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA