Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Sci Rep ; 13(1): 21437, 2023 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-38052928

RESUMEN

To test the hypothesis that dysregulated wound healing is associated with Urogynecologic mesh complications, we collected vaginal cell secretions using vaginal swabs after polypropylene mesh implantation in patients with (N = 39) and without (N = 40) complication. A customized multiplex immunoassay measured markers of inflammation (MCP-1, IGFBP-1, IL-2, IL-10, IL-17, PDGF-BB, bFGF, IL-1b, IL-6, IL-12p70, TNF-α), neuroinflammation (IL-1RA, TGF-ß, IL-15, IL-18, IL-3, M-CSF), angiogenesis (VEGF), and matrix proteins (fibronectin, tenasin c, thrombospondin-2, lumican) between groups. Patients with complications were younger, heavier, implanted with mesh longer, and more likely to be ever smokers. A 5 kg/m2 BMI increase and ever-smoking were associated with a 2.4-fold and sixfold increased risk of complication, respectively. Patients with the highest tertile of bFGF, fibronectin, thrombospondin-2, TNF-ß, or VEGF had an odds ratio (OR) of 11.8 for having a mesh complication while ≥ 3 elevated had an OR of 237 while controlling for age, BMI, and smoking. The highest tertile of bFGF, thrombospondin-2, and fibronectin together perfectly indicated a complication (P < 0.0001). A receiver-operator curve for high bFGF, thrombospondin-2, and fibronectin showed excellent discrimination between complications and controls (AUC 0.87). These data provide evidence of dysregulated wound healing in mesh complications. Modifiable factors provide potential targets for patient counseling and interventions.


Asunto(s)
Fibronectinas , Factor A de Crecimiento Endotelial Vascular , Femenino , Humanos , Mallas Quirúrgicas/efectos adversos , Cicatrización de Heridas , Trombospondinas
2.
Neurourol Urodyn ; 42(4): 751-760, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36805621

RESUMEN

AIMS: Treatment outcomes for accidental bowel leakage (ABL) may be influenced by age-related sarcopenia. We sought to determine if thickness of the anal sphincter complex on endoanal ultrasound correlated with function in women and men with ABL and if women demonstrated age-related anal sphincter thinning. METHODS: Consecutive patients with ABL presenting to our pelvic floor clinic from 2012 to 2017 were included. Clinical data were obtained from medical records. External anal sphincter (EAS), imaged by endoanal ultrasound at proximal, mid and distal locations, and IAS thickness were measured at 12, 3, 6, and 9 o'clock; puborectalis muscle (PRM) was measured at 4, 6, and 8 o'clock; and averaged. Anorectal manometry was conducted when clinically indicated. Data were compared using Mann-Whitney tests and linear regression. Results are reported as mean ± SD or median (IQR). RESULTS: Women (n = 136) were younger than men (n = 26) (61 ± 13 vs. 67 ± 13 years, p = 0.02). More women than men had pelvic surgery and less had colorectal surgery, spinal disorders, or a history of smoking (p < 0.05). Eighty-two percentage of women had an anal sphincter defect versus 31% of men (p < 0.01). All anal sphincter complex components were thinner in women than men with lower squeeze and resting pressures (p < 0.03), even in nulliparous women. Mean resting pressure was lower in older 6.1 (4.6-7.8) versus younger women 8.3 (5.0-12.9) mmHg, p = 0.04. CONCLUSIONS: Women, even nulliparous, with ABL demonstrate thinner and weaker anal sphincters than men, Aging correlated with an increase in anal sphincter thickness, suggesting that age-related changes in the intrinsic components of the anal sphincter complex associated with ABL are complex and are not always well demonstrated on endoanal ultrasound.


Asunto(s)
Envejecimiento , Canal Anal , Masculino , Humanos , Femenino , Anciano , Manometría/métodos , Presión , Ultrasonografía
3.
Female Pelvic Med Reconstr Surg ; 28(7): 452-460, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35536679

RESUMEN

IMPORTANCE: The U.S. Food and Drug Administration uses the Manufacturer and User Facility Device Experience database to evaluate the safety of urogynecologic meshes; however, reports on individual meshes have not been characterized. OBJECTIVE: The aim of the study was to compare complications among available urogynecologic meshes reported to the Manufacturer and User Facility Device Experience database. STUDY DESIGN: This study is a cross-sectional analysis of medical device reports (MDRs) of urogynecologic mesh from January 2004 to March 2019, using the Reed Tech Navigator (LexisNexis), which codes MDRs. The percentage of reports containing specific complaints (not an adverse event rate) were compared with χ 2 tests with Dunn-Sidak correction. Correlations with time on market, mesh weight, stiffness, and porosity were determined. RESULTS: The 34,485 reports examined included 6 transvaginal meshes, 4 sacrocolpopexy meshes, and 10 midurethral slings. Most reported events were pain, erosion, and infection. For transvaginal prolapse, less than 10% of Uphold Lite (Boston Scientific) reports contained pain or erosion versus greater than 90% of Prolift/Prolift+M (Ethicon, P < 0.001). For sacrocolpopexy mesh, greater than 90% of Gynemesh (Ethicon; Prolift in vaginal form) reports included erosion and pain versus less than 60% for Artisyn (Ethicon), Restorelle (Colpoplast), and Upsylon (Boston Scientific, P < 0.0001). For slings, Gynecare TVT Obturator had the highest proportion of erosion and pain complaints. Heavier sling meshes had more reports. When Ascend (Caldera Medical), an outlier with only 5 reports, was excluded, transvaginal mesh stiffness correlated strongly with number of reports. For transvaginal meshes, number of reports correlated with time on market (ρ = 0.8, P = 0.04). CONCLUSIONS: Individual meshes have different properties with different complication profiles, which should inform mesh development and use. Gynemesh MDRs included pain and erosion more frequently than others. Comprehensive registries are needed.


Asunto(s)
Prolapso de Órgano Pélvico , Cabestrillo Suburetral , Estudios Transversales , Femenino , Humanos , Dolor/etiología , Prolapso de Órgano Pélvico/etiología , Cabestrillo Suburetral/efectos adversos , Mallas Quirúrgicas/efectos adversos , Estados Unidos/epidemiología , United States Food and Drug Administration
4.
Female Pelvic Med Reconstr Surg ; 28(4): 194-200, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35443255

RESUMEN

BACKGROUND: Despite large trials designed to guide management on whether to perform a prophylactic continence procedure at the time of pelvic organ prolapse (POP) repair, it remains unclear if a staged or interval approach confers advantages in treatment of bothersome stress urinary incontinence (SUI) in women without bothersome SUI before their POP repair. OBJECTIVE: The objective of this study was to compare success of concomitant versus interval slings for the prevention/treatment of de novo bothersome SUI after POP repair. STUDY DESIGN: This multicenter retrospective cohort with prospective follow-up enrolled women with minimal or no SUI symptoms who underwent minimally invasive apical surgery for stage 2 or higher POP between 2011 and 2018 and had a concomitant sling placed at the time of POP surgery or an interval sling placed. Prospectively, all patients were administered the Urogenital Distress Inventory Short-Form 6, the Patient Global Impression of Improvement, and questions on reoperation/retreatment and complications. RESULTS: A total of 120 patients had concomitant slings, and 60 had interval slings. There were no differences in the proportion of patients who had intrinsic sphincter deficiency (22% vs 20%), although the concomitant sling group was more likely to have a positive cough stress test result (30% vs 8%, P = 0.006). The interval sling group was more likely to report "yes" to SUI symptoms on Urogenital Distress Inventory Short-Form 6 (3% vs 30%, P = 0.0006) and during their postoperative visit (0% vs 24%, P < 0.0001). There were no differences in surgical complications. CONCLUSIONS: Among women with minimal or no SUI symptoms undergoing prolapse repair, concomitant slings resulted in lower rates of bothersome SUI compared with similar women undergoing interval sling placement.


Asunto(s)
Prolapso de Órgano Pélvico , Cabestrillo Suburetral , Incontinencia Urinaria de Esfuerzo , Femenino , Humanos , Masculino , Prolapso de Órgano Pélvico/complicaciones , Prolapso de Órgano Pélvico/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Cabestrillo Suburetral/efectos adversos , Resultado del Tratamiento , Incontinencia Urinaria de Esfuerzo/etiología , Incontinencia Urinaria de Esfuerzo/prevención & control , Incontinencia Urinaria de Esfuerzo/cirugía
5.
J Robot Surg ; 16(3): 563-568, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34272656

RESUMEN

Surgical proctoring requires increasing resources in growing healthcare systems. In addition, travel has become less safe in the era of COVID-19. This study demonstrates surgeon satisfaction and safety with tele-proctoring in robotic gynecologic surgery. This pilot study assesses surgeon satisfaction and operative outcomes with a novel operative tele-proctoring system with a continuous two-way video-audio feed that allows the off-site surgeon to see the operating room, surgical field, and hands of the robotic surgeon. After thorough system testing, two experienced surgeons underwent tele-proctoring for hospital credentialing, completing 7 total cases. Each completed pre- and post-surveys developed from the Michigan Standard Simulation Experience Scale. Surgical characteristics were compared between tele-proctored cases and 59 historical cases proctored in-person over the last 8 years. Surgeons reported unanimous high satisfaction with tele-proctoring (5 ± 0). There were no major technologic issues. Five of the tele-proctored cases and 35 of controls were hysterectomies. Mean age was 48.2 ± 1.4 years, mean BMI was 29.6 ± 0.9 kg/m2, and mean uterine weight was 152 ± 112.3 g. Two-thirds had prior abdominal surgery (P > 0.1). Tele-proctored hysterectomies were 58 ± 6.5 min shorter than controls (P = 0.001). There were no differences in EBL or complication rates (P > 0.1). Tele-proctoring resulted in high surgeon satisfaction rates with no difference in EBL or complications. Tele-mentoring is a natural extension of tele-proctoring that could provide advanced surgical expertise far beyond where we can physically reach.


Asunto(s)
COVID-19 , Procedimientos Quirúrgicos Robotizados , Cirujanos , COVID-19/epidemiología , Femenino , Procedimientos Quirúrgicos Ginecológicos , Humanos , Persona de Mediana Edad , Satisfacción Personal , Proyectos Piloto , Procedimientos Quirúrgicos Robotizados/métodos
6.
Int Urogynecol J ; 33(2): 327-335, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33860812

RESUMEN

INTRODUCTION AND HYPOTHESIS: We compared the impact of a mesh manufactured from the soft elastomer polydimethylsiloxane (PDMS) to that of a widely used lightweight polypropylene (PP) mesh. To achieve a similar overall device stiffness between meshes, the PDMS mesh was made with more material and therefore was heavier and less porous. We hypothesized that the soft polymer PDMS mesh, despite having more material, would have a similar impact on the vagina as the PP mesh. METHODS: PDMS and PP meshes were implanted onto the vaginas of 20 rabbits via colpopexy. Ten rabbits served as sham. At 12 weeks, mesh-vagina complexes were explanted and assessed for contractile function, histomorphology, total collagen, and glycosaminoglycan content. Outcome measures were compared using one-way ANOVA and Kruskal-Wallis testing with appropriate post-hoc testing. RESULTS: Relative to sham, vaginal contractility was reduced following the implantation of PP (p = 0.035) but not the softer PDMS (p = 0.495). PP had an overall greater negative impact on total collagen and glycosaminoglycan content, decreasing by 53% (p < 0.001) and 54% (p < 0.001) compared to reductions of 35% (p = 0.004 and p < 0.001) with PDMS. However, there were no significant differences in the contractility, collagen fiber thickness, total collagen, and glycosaminoglycan content between the two meshes. CONCLUSIONS: Despite having a substantially higher weight, PDMS had a similar impact on the vagina compared to a low-weight PP mesh, implicating soft polymers as potential alternatives to PP. The notion that heavyweight meshes are associated with a worse host response is not applicable when comparing across materials.


Asunto(s)
Prolapso de Órgano Pélvico , Polipropilenos , Animales , Elastómeros , Femenino , Humanos , Prolapso de Órgano Pélvico/cirugía , Conejos , Mallas Quirúrgicas , Vagina/cirugía
7.
Female Pelvic Med Reconstr Surg ; 27(3): 175-180, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33620901

RESUMEN

OBJECTIVE: The purpose of this analysis is to determine if postoperative opioid usage differs among women randomized to office or phone preoperative counseling for pelvic organ prolapse surgery. METHODS: This was a planned exploratory analysis of the Patient Preparedness for Pelvic Organ Prolapse Surgery study, which randomized women to standardized preoperative counseling by office visit or phone call before prolapse surgery. Inclusion criteria were the completion of the assigned counseling intervention and submission of a 7-day postoperative pain and medication diary. Multivariable logistic regression was done to assess the association between counseling method and total opioid use while controlling for variables significant on univariate analysis (surgery type and county of residence). RESULTS: There were 84 participants with postoperative data (41 office, 43 phone). Median total number of 5-mg oxycodone tablets used was higher for the office group (5 [interquartile range, 0-10]) than the phone group (0 [interquartile range, 0-2], P = 0.002). On multivariable logistic regression, women who underwent phone counseling were less likely to be in the highest third of opioid use when controlling for surgery type and county of residence (odds ratio, 0.23; P = 0.012; 95% confidence interval, 0.07-0.72). Daily pain scores and nonopioid medication use (nonsteroidal anti-inflammatory medications and acetaminophen) were similar between groups (P > 0.05). CONCLUSIONS: Despite similar pain scores, women who received preoperative phone counseling before pelvic organ prolapse surgery had lower opioid utilization than those with office counseling. Further research is needed to determine the optimal method of preoperative counseling and its role in postoperative pain management.


Asunto(s)
Analgésicos Opioides/uso terapéutico , Consejo , Oxicodona/uso terapéutico , Dolor Postoperatorio/tratamiento farmacológico , Prolapso de Órgano Pélvico/cirugía , Cuidados Preoperatorios/métodos , Anciano , Recuperación Mejorada Después de la Cirugía , Femenino , Humanos , Persona de Mediana Edad , Visita a Consultorio Médico , Teléfono
8.
Acta Biomater ; 115: 127-135, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32771596

RESUMEN

Polypropylene mesh is frequently used in urogynecology procedures; however, pain and mesh exposure into the vagina occur in ~10% of cases. Mesh-induced pain, which occurs with or without exposure, persists after removal in 50% of cases. Chronic pain history predicts poor response to mesh removal but only a fraction have this diagnosis. We hypothesize that mesh induced pain is correlated with fibrosis and failure to improve with a heightened inflammatory and fibrotic host response. Women undergoing mesh removal were offered participation in a mesh biorepository. Standardized questionnaires including visual analog scale (VAS) pelvic pain scores were completed at enrollment and 6 months after removal. Responders were considered those with ≥13 mm VAS improvement. 30 mesh-tissue explants were randomly selected for analysis. Samples were labeled for CD8, CD4 (Th) and FoxP3 (Tregs). Peri-fiber collagen deposition (fibrosis) was measured using a customized semi-quantitative assay. Concentrations of TGF-b1, bFGF, MCP-1, PDGF-BB, and IGFBP-1 in tissue were determined by immunoassay and compared to vaginal control biopsies with pathway analysis. VAS pain scores were correlated with degree of histologic fibrosis. Responders had more Tregs (7.8 vs 0.3 per mm2, p = 0.036) and patients were 1.6 times as likely to be a responder for every additional Treg/mm2 (p = 0.05). Pro-fibrotic TGF-ß1 was doubled in nonresponders (p = 0.032). On pathway analysis, decreased bFGF and increased PDGF-BB provide a possible mechanism for upregulation of TGF-ß1. In conclusion, fibrosis is a plausible mechanism of pain complications and the adaptive immune response likely contributes to mitigation/prevention of complications and recovery in affected patients. STATEMENT OF SIGNIFICANCE: Polypropylene mesh improves anatomical outcomes in urogynecologic procedures, but is associated with complications, including pain and exposure through the vaginal epithelium. Mesh-induced pain is difficult to treat, and it is unclear why only half of women experience pain improvement after mesh removal. In this study, patient pain correlated with the presence of fibrosis and women with more T regulatory cells and lower TGF-ß1 were more likely to have pain improvement following mesh removal. These findings implicate fibrosis as a mechanism of pain complications and suggest that the adaptive immune response may be responsible for prevention of complication and recovery. This improved understanding of how mesh can lead to pain moves us closer to the ultimate goal of preventing mesh complications.


Asunto(s)
Mallas Quirúrgicas , Factor de Crecimiento Transformador beta1 , Colágeno , Femenino , Humanos , Polipropilenos , Mallas Quirúrgicas/efectos adversos , Vagina
9.
Obstet Gynecol ; 135(5): 1084-1090, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32282600

RESUMEN

OBJECTIVE: To compare temporal trends of urogynecologic mesh medical device reports with sentinel U.S. Food and Drug Administration (FDA) notices and to examine all linked reports of patient death. METHODS: The Reed Tech Navigator is an online tool used to extract and analyze data in the Manufacturer and User Facility Device Experience database. We used FDA product codes to search for reports of synthetic mesh for stress urinary incontinence (SUI) and pelvic organ prolapse (POP). Reports with "death" listed as a patient event were queried further. RESULTS: There were 43,970 medical device reports involving urogynecologic mesh reported to the FDA between August 2000 and January 2019, with most occurring after the 2011 FDA communication (n=43,018, 97.8%). Of these medical device reports, 64.6% (n=28,422) were for SUI products, 27.0% (n=11,876) were for transvaginal POP products, and 8.4% (n=3,672) were for transabdominal POP products. Peak reporting occurred in 2013, which corresponded with the first major plaintiff verdicts and class action vaginal mesh settlement. There were 645 (1.5%) medical device reports of death, with 49.3% (n=318) having no cause of death identified. Only four (0.6%) could be directly attributed to the initial surgery. CONCLUSION: Since 2011, urogynecologic mesh has been the focus of thousands of medical device reports annually, although the data submitted are often incomplete. Few reported deaths are directly attributable to mesh products, and the majority lack sufficient information to draw causal conclusions. A high-quality registry is necessary to improve our understanding of the patient effect from urogynecologic mesh products.


Asunto(s)
Prolapso de Órgano Pélvico/cirugía , Vigilancia de Guardia , Cabestrillo Suburetral/tendencias , Mallas Quirúrgicas/tendencias , Incontinencia Urinaria de Esfuerzo/cirugía , Bases de Datos Factuales , Femenino , Humanos , Estados Unidos , United States Food and Drug Administration
10.
Int Urogynecol J ; 31(1): 91-99, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31418044

RESUMEN

INTRODUCTION AND HYPOTHESIS: New Zealand white rabbits are an inexpensive large-animal model. This study explored the rabbit as a model for mesh-augmented colpopexy using the intra-abdominal vagina. We hypothesized that polypropylene mesh would negatively impact rabbit vaginal smooth muscle (VSM) morphology and contractile function, similar to the nonhuman primate (NHP)-the established model for prolapse mesh evaluation. METHODS: Restorelle was implanted onto the vagina of ten rabbits via lumbar colpopexy after a hysterectomy. Ten rabbits served as sham. Twelve weeks post-implantation, the vagina was excised and VSM morphology and vaginal contractility were assessed. Outcome measures were compared using independent samples t and Mann-Whitney U tests with a Bonferroni correction, where appropriate. Results from the rabbits were compared with published NHP data. RESULTS: Animals had similar age, parity and BMI. VSM was 18% thinner after Restorelle implantation, P = 0.027. Vaginal contractility was 43% decreased in response to 120 mM KCl (P = 0.003), similar to the 46% reduction observed in the NHP vagina implanted with Restorelle (P = 0.027). Three meshes wrinkled in vivo, resulting in dramatic thinning of the underlying vagina in the area of the mesh causing a mesh exposure. CONCLUSIONS: Polypropylene mesh negatively impacts VSM morphology and vaginal contractility in the rabbit, similar to the NHP, suggesting that the rabbit may serve as an alternative large-animal model. The vaginal thinning and appearance of a mesh exposure in the area of a mesh wrinkle suggest the rabbit may also serve as a model for understanding the pathophysiology of mesh exposure.


Asunto(s)
Colposcopía/métodos , Prolapso de Órgano Pélvico/cirugía , Implantación de Prótesis/métodos , Mallas Quirúrgicas , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Vértebras Lumbares/cirugía , Polipropilenos , Conejos , Vagina/cirugía
11.
Acta Biomater ; 96: 203-210, 2019 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-31326666

RESUMEN

Polypropylene mesh is widely used in urogynecologic surgery, but complications rates (pain and exposure) approach 10%. Emerging evidence implicates the adaptive immune system in regulating the foreign body response to mesh, particularly regulatory T cells (Tregs), which modify macrophage differentiation and down-regulate CD8+ effector T cells. We hypothesize that Tregs protect against a profibrotic response, a likely mechanism of pain complications. Here, thin sections of mesh-tissue complexes removed for the primary complaint of pain (N = 14) or exposure (N = 15) were labeled for CD8, CD4 (Th), and FoxP3 (Tregs) via immunofluorescence. The same sections were analyzed for localized collagen deposition via a customized semi-quantitative assessment (0.25 mm2 grid) after trichrome staining. TGF-ß1 concentrations were determined by enzyme-linked immunosorbent assay. Fewer Treg and CD4+ cells were found in fibrotic areas versus non-fibrotic areas (503 and 550/cm2 fewer, respectively, both P < 0.001). TGF-ß1 was higher in mesh samples compared to autologous control biopsies. TGF-ß 1 inversely correlated with age, r -0.636(p = 0.008). No differences were found in T cell subgroups or fibrotic indices between pain and exposure groups. A moderate inverse relationship was found between TGF-ß1 and Tregs (r -0.402, P = 0.009). Tregs were present up to 12 years after mesh implantation, challenging the assumption that the adaptive immune response to a foreign body is transient. In conclusion, the inverse relationship between fibrosis and Tregs, and TGF-ß1 and Tregs points to a protective role of these cells. Similar immunologic responses in patients with pain and exposure suggest these complications exist along a spectrum. STATEMENT OF SIGNIFICANCE: The use of polypropylene mesh has been associated with improved outcomes in urogynecologic surgery, but is associated with significant complications, including pain and exposure through the vaginal epithelium. The host immune response features a prolonged inflammatory reaction containing innate immune cells and T lymphocytes clustered in capsules around the mesh fibers. This study uncovers the inverse relationship between T regulatory cells and the extent of fibrosis around the mesh, suggesting an anti-fibrotic effect. In addition, concentrations of T regulatory and T effector cells and levels of fibrosis connect these two most common complications into one mechanistic pathway. These new insights into the immune response to implanted mesh are an important step in understanding the causes of these surgical complications.


Asunto(s)
Mallas Quirúrgicas/efectos adversos , Linfocitos T Reguladores/inmunología , Inmunidad Adaptativa , Adulto , Anciano , Biopsia , Colágeno/metabolismo , Femenino , Fibrosis , Humanos , Persona de Mediana Edad , Dolor/etiología , Factor de Crecimiento Transformador beta1/metabolismo , Prolapso Uterino/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA