Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
Int J Orthop Trauma Nurs ; 53: 101094, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38508099

RESUMEN

OBJECTIVE: Primary aim; to determine the feasibility of implementation of the INTERMED Self-Assessment (IM-SA) in adult patients scheduled for total knee arthroplasty (TKA). Secondary aim; to measure biopsychosocial complexity, referral to psychiatry or psychology in cases of complexity and to gain insight into the relation between biopsychosocial complexity and length of stay (LOS), method of discharge (MOD) and polypharmacy. METHODS: A feasibility study was conducted with 76 participants in a general hospital in the Netherlands. Feasibility was determined by the number of completed questionnaires, time spent completing the questionnaire and the attitude of staff and patients towards the IM-SA. A cut off point ≥19 on the IM-SA was used to determine the prevalence of biopsychosocial complexity. A case file study was performed to check if referral to psychiatry or psychology had taken place. The Spearman's Rank Correlation Coefficient or Phi was used to determine if there was a relation between biopsychosocial complexity and LOS, MOD and polypharmacy. RESULTS: All participants completed the IM-SA. The average time spent completing the questionnaire was 11.46 min (SD 5.74). The attitude towards the IM-SA was positive. The prevalence of biopsychosocial complexity was 11.84%. Referral to psychiatry or psychology did not take place. There was no relation between complexity and LOS (Spearman's rho (r) = 0.079, p = 0.499, MOD (Phi = 0.169, p = 0.173) and polypharmacy (Phi = 0.007, p = 0.953). CONCLUSION: Biopsychosocial complexity can be identified in TKA patients during the pre-operative phase by using the IM-SA. Implementation of the IM-SA in a Dutch general hospital is feasible.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Electivos , Estudios de Factibilidad , Humanos , Artroplastia de Reemplazo de Rodilla/psicología , Masculino , Proyectos Piloto , Femenino , Anciano , Procedimientos Quirúrgicos Electivos/psicología , Persona de Mediana Edad , Encuestas y Cuestionarios , Países Bajos , Tiempo de Internación/estadística & datos numéricos , Anciano de 80 o más Años , Autoevaluación (Psicología)
2.
Int Orthop ; 45(6): 1447-1454, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33459828

RESUMEN

PURPOSE: In press-fit total hip arthroplasty (THA), primary stability is needed to avoid micromotion and hereby aseptic loosening, the main reason for early revision. High aseptic loosening revision rates of the seleXys TH+ cup (Mathys Medical) with Ceramys ceramic-on-ceramic (CoC) bearing are seen in literature. Since CoC is presumed to overcome long-term wear-related revisions, the reason for early failure of this cup is important to clarify. The aim is to investigate its ten year outcomes and differentiate between potential causes and identify risk factors for aseptic loosening. METHODS: Retrospective screening of a prospectively documented series of 315 THAs was performed. Primary outcome was cumulative incidence of cup revision due to aseptic loosening. Secondary outcomes were component revision and reoperation. Additionally, potential predictive factors for aseptic loosening were evaluated. RESULTS: At the median follow-up of 9.7 years [IQR 4.4; 10.3], 48 TH+ (15.2%) were revised due to aseptic loosening. Competing risk analysis showed a ten year cumulative incidence of cup revision due to aseptic loosening of 15.6% (95% CI 12.0-20.2). Stabilization of early revision rates was observed, following a high rate of respectively 81.3% (n = 39) and 95.8% (n = 46) within the first two and three years. No significant predictive factors for aseptic loosening were found. CONCLUSION: The ten year results of seleXys TH+ cup with Ceramys CoC bearing showed an unacceptable high aseptic loosening rate, which stabilized over time after a high early failure incidence. This could be attributed to a problem with osseointegration during the transition of primary to definitive stability.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cerámica , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Sobrevivientes , Resultado del Tratamiento
3.
Burns Trauma ; 3: 18, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-27574664

RESUMEN

Nowadays, most patients with severe burns will survive their injury. This evolution is accompanied by the challenge to cover a large percentage of total body surface area burned. Consequently, more and more patients have to deal with the sequelae of burn scars and require (multiple) reconstructions. This review provides a gross overview of developments in the field of tissue engineering for permanent burn wound coverage and reconstructive burn surgery, focusing on usage and clinical effectiveness. Not only skin substitutes will be discussed but also the replacement of subcutaneous fat tissue and cartilage.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA