Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Neurointerv Surg ; 2023 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-38050090

RESUMEN

BACKGROUND: Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. OBJECTIVE: To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. METHODS: Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b-3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a -10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0-2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). RESULTS: From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12-20). In the primary analysis population (n=107), eTICI 2b-3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority P<0.0001; post hoc superiority P<0.0001). First pass eTICI 2b-3 was observed in 73.8% (79/107), with first pass eTICI 2b67-3 in 69.2% (74/107) and eTICI 2c-3 in 48.6% (52/107). Median number of passes was 1 (IQR 1-2). Final eTICI 2b-3 rate was 99.1% (106/107); final eTICI 2b67-3 rate was 91.6% (98/107); final eTICI 2c-3 rate was 72.9% (78/107). Good outcome (90-day mRS score 0-2) was seen in 65.1% (69/106). Mortality was 9.4% (13/138) with sICH in 5.0% (7/139). CONCLUSIONS: The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. TRIAL REGISTRATION NUMBER: NCT04514562.

2.
J Neurointerv Surg ; 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37527927

RESUMEN

BACKGROUND: Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. METHODS: In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. RESULTS: Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (P<0.001) as did incompletely occluded aneurysms (P<0.001). Histologically, all aneurysms treated with SEAL Arc devices were completely healed. CONCLUSION: Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.

3.
J Neurointerv Surg ; 10(Suppl 1): i45-i49, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30037956

RESUMEN

BACKGROUND: Limited post-marketing data exist on the use of the Solitaire FR device in clinical practice. The North American Solitaire Stent Retriever Acute Stroke (NASA) registry aimed to assess the real world performance of the Solitaire FR device in contrast with the results from the SWIFT (Solitaire with the Intention for Thrombectomy) and TREVO 2 (Trevo versus Merci retrievers for thrombectomy revascularization of large vessel occlusions in acute ischemic stroke) trials. METHODS: The investigator initiated NASA registry recruited North American sites to submit retrospective angiographic and clinical outcome data on consecutive acute ischemic stroke (AIS) patients treated with the Solitaire FR between March 2012 and February 2013. The primary outcome was a Thrombolysis in Myocardial Ischemia (TIMI) score of ≥2 or a Treatment in Cerebral Infarction (TICI) score of ≥2a. Secondary outcomes were 90 day modified Rankin Scale (mRS) score, mortality, and symptomatic intracranial hemorrhage. RESULTS: 354 patients underwent treatment for AIS using the Solitaire FR device in 24 centers. Mean time from onset to groin puncture was 363.4±239 min, mean fluoroscopy time was 32.9±25.7 min, and mean procedure time was 100.9±57.8 min. Recanalization outcome: TIMI ≥2 rate of 83.3% (315/354) and TICI ≥2a rate of 87.5% (310/354) compared with the operator reported TIMI ≥2 rate of 83% in SWIFT and TICI ≥2a rate of 85% in TREVO 2. Clinical outcome: 42% (132/315) of NASA patients demonstrated a 90 day mRS ≤2 compared with 37% (SWIFT) and 40% (TREVO 2). 90 day mortality was 30.2% (95/315) versus 17.2% (SWIFT) and 29% (TREVO 2). CONCLUSIONS: The NASA registry demonstrated that the Solitaire FR device performance in clinical practice is comparable with the SWIFT and TREVO 2 trial results.


Asunto(s)
Isquemia Encefálica/cirugía , Vigilancia de Productos Comercializados/tendencias , Sistema de Registros , Stents/tendencias , Accidente Cerebrovascular/cirugía , Trombectomía/tendencias , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/epidemiología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , América del Norte/epidemiología , Vigilancia de Productos Comercializados/métodos , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Trombectomía/métodos , Resultado del Tratamiento , Estados Unidos/epidemiología
4.
J Neurointerv Surg ; 9(4): 366-369, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27073195

RESUMEN

BACKGROUND: Time to reperfusion following endovascular treatment (ET) predicts outcomes after acute ischemic stroke (AIS). OBJECTIVE: To assess the time-outcome relationship within reperfusion grades in the North American Solitaire Acute Stroke registry. METHODS: We identified patients given ET for anterior circulation ischemic stroke within 8 h from onset and in whom reperfusion was achieved. Together with clinical and outcome data, site-adjudicated modified Thrombolysis in Cerebral Ischemia (TICI) was recorded. We assessed the impact of time to reperfusion (onset to procedure completion time) on good outcome (modified Rankin Scale 0-2 at 3 months) in patients who achieved TICI 2 or higher reperfusion in multivariable models. We further assessed this relationship within strata of reperfusion grades. A p<0.05 was considered significant. RESULTS: Independent predictors of good outcome at 3 months among those achieving TICI ≥2a reperfusion (n=188) were initial National Institutes of Health Stroke Scale score (adjusted OR=0.90, 95% CI 0.85 to 0.95), symptomatic hemorrhage (adj. OR=0.16, 95% CI 0.05 to 0.60), TICI grade (TICI 3: adj. OR=11.52, 95% CI 3.34 to 39.77; TICI 2b: adj. OR=5.14, 95% CI 1.61 to 16.39), and time to reperfusion per 30 min interval (adj. OR=0.91, 95% CI 0.82 to 0.99). There was an interaction between final TICI grade and 30 min time to reperfusion intervals (p=0.001) such that the effect of time was strongest in TICI 2a patients. CONCLUSIONS: Time to reperfusion was a strong predictor of outcome following ET for AIS. However, the effect varied by TICI grade such that its greatest effect was in those achieving TICI 2a reperfusion.


Asunto(s)
Isquemia Encefálica/fisiopatología , Infarto Cerebral/fisiopatología , Infarto Cerebral/terapia , Intervención Médica Temprana , Reperfusión/instrumentación , Reperfusión/métodos , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/terapia , Trombectomía/instrumentación , Trombectomía/métodos , Actividades Cotidianas/clasificación , Anciano , Isquemia Encefálica/terapia , Estudios de Cohortes , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
5.
J Neurointerv Surg ; 8(3): 224-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25564538

RESUMEN

BACKGROUND: Mechanical thrombectomy with stent-retrievers results in higher recanalization rates compared with previous devices. Despite successful recanalization rates (Thrombolysis in Cerebral Infarction (TICI) score ≥2b) of 70-83%, good outcomes by 90-day modified Rankin Scale (mRS) score ≤2 are achieved in only 40-55% of patients. We evaluated predictors of poor outcomes (mRS >2) despite successful recanalization (TICI ≥2b) in the North American Solitaire Stent Retriever Acute Stroke (NASA) registry. METHODS: Logistic regression was used to evaluate baseline characteristics and recanalization outcomes for association with 90-day mRS score of 0-2 (good outcome) vs 3-6 (poor outcome). Univariate tests were carried out for all factors. A multivariable model was developed based on backwards selection from the factors with at least marginal significance (p≤0.10) on univariate analysis with the retention criterion set at p≤0.05. The model was refit to minimize the number of cases excluded because of missing covariate values; the c-statistic was a measure of predictive power. RESULTS: Of 354 patients, 256 (72.3%) were recanalized successfully. Based on 234 recanalized patients evaluated for 90-day mRS score, 116 (49.6%) had poor outcomes. Univariate analysis identified an increased risk of poor outcome for age ≥80 years, occlusion site of internal carotid artery (ICA)/basilar artery, National Institute of Health Stroke Scale (NIHSS) score ≥18, history of diabetes mellitus, TICI 2b, use of rescue therapy, not using a balloon-guided catheter or intravenous tissue plasminogen activator (IV t-PA), and >30 min to recanalization (p≤0.05). In multivariable analysis, age ≥80 years, occlusion site ICA/basilar, initial NIHSS score ≥18, diabetes, absence of IV t-PA, ≥3 passes, and use of rescue therapy were significant independent predictors of poor 90-day outcome in a model with good predictive power (c-index=0.80). CONCLUSIONS: Age, occlusion site, high NIHSS, diabetes, no IV t-PA, ≥3 passes, and use of rescue therapy are associated with poor 90-day outcome despite successful recanalization.


Asunto(s)
Sistema de Registros , Reperfusión/métodos , Stents , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , América del Norte/epidemiología , Valor Predictivo de las Pruebas , Análisis de Regresión , Reperfusión/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Resultado del Tratamiento
6.
J Neurointerv Surg ; 6(8): 584-8, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24062252

RESUMEN

BACKGROUND: Limited post-marketing data exist on the use of the Solitaire FR device in clinical practice. The North American Solitaire Stent Retriever Acute Stroke (NASA) registry aimed to assess the real world performance of the Solitaire FR device in contrast with the results from the SWIFT (Solitaire with the Intention for Thrombectomy) and TREVO 2 (Trevo versus Merci retrievers for thrombectomy revascularization of large vessel occlusions in acute ischemic stroke) trials. METHODS: The investigator initiated NASA registry recruited North American sites to submit retrospective angiographic and clinical outcome data on consecutive acute ischemic stroke (AIS) patients treated with the Solitaire FR between March 2012 and February 2013. The primary outcome was a Thrombolysis in Myocardial Ischemia (TIMI) score of ≥2 or a Treatment in Cerebral Infarction (TICI) score of ≥2a. Secondary outcomes were 90 day modified Rankin Scale (mRS) score, mortality, and symptomatic intracranial hemorrhage. RESULTS: 354 patients underwent treatment for AIS using the Solitaire FR device in 24 centers. Mean time from onset to groin puncture was 363.4±239 min, mean fluoroscopy time was 32.9±25.7 min, and mean procedure time was 100.9±57.8 min. Recanalization outcome: TIMI ≥2 rate of 83.3% (315/354) and TICI ≥2a rate of 87.5% (310/354) compared with the operator reported TIMI ≥2 rate of 83% in SWIFT and TICI ≥2a rate of 85% in TREVO 2. CLINICAL OUTCOME: 42% (132/315) of NASA patients demonstrated a 90 day mRS ≤2 compared with 37% (SWIFT) and 40% (TREVO 2). 90 day mortality was 30.2% (95/315) versus 17.2% (SWIFT) and 29% (TREVO 2). CONCLUSIONS: The NASA registry demonstrated that the Solitaire FR device performance in clinical practice is comparable with the SWIFT and TREVO 2 trial results.


Asunto(s)
Isquemia Encefálica , Circulación Cerebrovascular/fisiología , Trombolisis Mecánica , Evaluación de Resultado en la Atención de Salud , Sistema de Registros/estadística & datos numéricos , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/mortalidad , Isquemia Encefálica/cirugía , Femenino , Humanos , Masculino , Trombolisis Mecánica/instrumentación , Trombolisis Mecánica/mortalidad , Trombolisis Mecánica/estadística & datos numéricos , Persona de Mediana Edad , América del Norte , Stents/estadística & datos numéricos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/cirugía
7.
Front Neurol ; 2: 64, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22022319

RESUMEN

Endovascular tumor embolization as adjunctive therapy for head and neck cancers is evolving and has become an important part of the tools available for their treatment. Careful study of tumor vascular anatomy and adhering to general principles of intra-arterial therapy can prove this approach to be effective and safe. Various embolic materials are available and can be suited for a given tumor and its vascular supply. This article aims to summarize current methods and agents used in endovascular head and neck tumor embolization and discuss important angiographic and treatment characteristics of selected common head and neck tumors.

9.
Photochem Photobiol ; 78(4): 331-6, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14626659

RESUMEN

Very little information exists on the amount of natural and artificial UV light required to cause sunburn and tanning in individuals with very pale skin who are at the greatest risk of developing skin cancer. We have investigated minimal erythema dose (MED) and minimal melanogenic dose (MMD) in a group of 31 volunteers with Fitzpatrick skin types I and II using an Oriel 1000 W xenon arc solar simulator and natural sunlight in Sydney, Australia. We measured the erythemal and melanogenic responses using conventional visual scoring, a chromameter and an erythema meter. We found that the average MED measured visually using the artificial UV source was 68.7 +/- 3.3 mJ/cm2 (3.4 +/- 0.2 standard erythema doses [SED]), which was significantly different from the MED of sunlight, which was 93.6 +/- 5.6 mJ/cm2 (P < 0.001) (11.7 +/- 0.7 SED). We also found significant correlations between the solar-simulated MED values, the melanin index (erythema meter) and the L* function (chromameter). The average MMD (obtained in 16 volunteers only) using solar-simulated light was 85.6 +/- 4.9 mJ/cm2, which was significantly less than that measured with natural sunlight (118.3 +/- 8.6 mJ/cm2; P < 0.05). We mathematically modeled the data for both the chromameter and the erythema meter to see if we were able to obtain a more objective measure of MED and differentiation between skin types. Using this model, we were able to detect erythemal responses using the erythema index function of the erythema meter and the a* function of the chromameter at lower UV doses than either the standard visual or COLIPA methods.


Asunto(s)
Eritema/etiología , Melaninas/biosíntesis , Piel/efectos de la radiación , Luz Solar , Adolescente , Adulto , Colorimetría , Femenino , Humanos , Masculino , Persona de Mediana Edad , Piel/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA