Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Eur J Cardiothorac Surg ; 45(1): 126-31, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23657550

RESUMEN

OBJECTIVES: Atrial fibrillation (AF) is a significant risk factor for embolic stroke originating from the left atrial appendage (LAA). This is the first report of long-term safety and efficacy data on LAA closure using a novel epicardial LAA clip device in patients undergoing cardiac surgery. METHODS: Forty patients with AF were enrolled in this prospective 'first-in-man' trial. The inclusion criterion was elective cardiac surgery in adult patients with AF for which a concomitant ablation procedure was planned. Intraoperative transoesophageal echocardiography (TEE) was used to exclude LAA thrombus at baseline and evaluate LAA perfusion after the procedure, while computed tomography (CT) was used for serial imagery workup at baseline, 3-, 12-, 24- and 36-month follow-up. RESULTS: Early mortality was 10% due to non-device-related reasons, and thus 36 patients were included in the follow-up consisting of 1285 patient-days and mean duration of 3.5 ± 0.5 years. On CT, clips were found to be stable, showing no secondary dislocation 36 months after surgery. No intracardial thrombi were seen, none of the LAA was reperfused and in regard to LAA stump, none of the patients demonstrated a residual neck >1 cm. Apart from one unrelated transient ischaemic attack (TIA) that occurred 2 years after surgery in a patient with carotid plaque, no other strokes and/or neurological events demonstrated in any of the studied patients during follow-up. CONCLUSION: This is the first prospective trial in which concomitant epicardial LAA occlusion using this novel epicardial LAA clip device is 100% effective, safe and durable in the long term. Closure of the LAA by epicardial clipping is applicable to all-comers regardless of LAA morphology. Minimal access epicardial LAA clip closure may become an interesting therapeutic option for patients in AF who are not amenable to anticoagulation and/or catheter closure. Further data are necessary to establish LAA occlusion as a true and viable therapy for stroke prevention. CLINICAL TRIAL REGISTRATION: The trial is registered at www.ClinicalTrials.gov, reference: NCT00567515.


Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Anciano , Anticoagulantes , Fibrilación Atrial/epidemiología , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Humanos , Ataque Isquémico Transitorio/epidemiología , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Accidente Cerebrovascular/epidemiología , Tomografía Computarizada por Rayos X
2.
Heart Surg Forum ; 15(3): E143-4, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22698601

RESUMEN

A 77-year-old patient was referred for progressive fatigue and dyspnea on exertion. Preoperative imaging evaluations including transthoracic echocardiography and computed tomography were suggestive of a chronic ascending aortic dissection with an intramural hematoma. Intraoperatively, the intramural structure was identified as an abscess cavity.


Asunto(s)
Absceso/diagnóstico , Absceso/cirugía , Aortitis/diagnóstico , Aortitis/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Disección Aórtica/diagnóstico , Aneurisma de la Aorta/diagnóstico , Humanos , Masculino , Resultado del Tratamiento
3.
Eur Radiol ; 21(2): 385-92, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20711733

RESUMEN

PURPOSE: To differentiate proxy renal cystic lesions containing protein, blood, iodine contrast or saline solutions using dual-energy CT (DECT) equipped with a new tin filter technology (TFT). MATERIALS AND METHODS: 70 proxies (saline, protein, blood and contrast agent) were placed in unenhanced and contrast-enhanced kidney phantoms. DECT was performed at 80/140 kV with and without tin filtering. Two readers measured the CT attenuation values in all proxies twice. An 80/140 kV ratio was calculated. RESULTS: All intra- and interobserver agreements were excellent (r = 0.93-0.97; p < 0.001). All CT attenuation values were significantly higher in the enhanced than in the unenhanced setting (p < 0.05; average increase, 12.5 ± 3.6 HU), while the ratios remained similar (each, p > 0.05). The CT attenuation of protein, blood and contrast agent solution differed significantly with tin filtering (p < 0.01-0.05). Significant differences were found between the ratios of protein and blood compared to contrast medium solution (each, p < 0.05) and between the ratios of protein and blood in both phantoms with tin filtering (each, p < 0.05). CONCLUSION: DECT allows discrimination between a proxy renal lesion containing contrast agent and lesions containing protein and blood through their different attenuation at 80 kV and 140 kV. Further discrimination between protein and blood containing proxies is possible when using a tin filter.


Asunto(s)
Filtración/métodos , Enfermedades Renales Quísticas/diagnóstico por imagen , Fantasmas de Imagen , Estaño , Tomografía Computarizada por Rayos X/instrumentación , Sangre , Proteínas Sanguíneas , Medios de Contraste , Humanos , Yodo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
4.
J Cardiovasc Comput Tomogr ; 4(5): 301-8, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20947041

RESUMEN

BACKGROUND: Identification and differentiation of coronary atherosclerotic plaques may improve risk stratification for incident coronary events. OBJECTIVE: We investigated the ability of dual-source computed tomography (CT) to depict and characterize atherosclerotic coronary plaques. METHODS: Contrast-enhanced CT was performed in 25 human heart specimens with a total of 322 histologically determined plaques. Coronary plaques were classified on CT as (1) noncalcified, mixed, or calcified and (2) by CT attenuation values. Atherosclerotic plaques were histopathologically characterized according to the Stary classification. RESULTS: CT detected 79% (245/322) of all plaques. Lesions missed by CT were generally early lesions, type I (n = 31), type II (n = 38), or type III (n = 8), according to Stary. CT detected 29% of early (Stary I-III) and 100% of advanced (Stary IV-VIII) plaques. Plaque classification as noncalcified was sensitive (100%) and specific (72%) for early, whereas classification as mixed/calcified was sensitive (92%, 89%) and specific (100%) for advanced plaques. Calcified plaques on CT were detected with high sensitivity (80%) and specificity (95%). Other subtypes were not distinguishable with CT according to the presence or absence of calcification. CT density was significantly higher for advanced (306 ± 470 HU) than for early (42 ± 14 HU; P < 0.01) plaques. The mean CT density value of type VII plaques (512 ± 349 HU) was significantly higher than those of other plaques (34-101 HU; P < 0.001). CONCLUSIONS: CT reliably depicts advanced coronary plaques and allows for the differentiation between early and advanced plaques.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/patología , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Cadáver , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Invest Radiol ; 45(6): 324-30, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20404735

RESUMEN

OBJECTIVES: To prospectively assess electrocardiography (ECG)-synchronized dual-source computed tomography (CT) in high-pitch spiral acquisition mode for the evaluation of coronary artery bypass graft (CABG) patency regarding image quality and radiation dose. MATERIALS AND METHODS: Fifty consecutive patients (47 men, age 69.6 +/- 9.6 years, body mass index 26.6 +/- 3.5 kg/m) underwent clinically indicated 128-slice dual-source CT angiography of the entire thorax for the evaluation of graft patency after CABG surgery using a prospectively ECG-synchronized high-pitch spiral acquisition mode (pitch 3.2; 100 kV tube voltage, 0.28 seconds gantry rotation time). Heart rates (HR) were noted. Image quality of the proximal anastomosis, graft body, distal anastomosis, and postanastomotic coronary artery were graded by 2 independent readers on a 3-point scale (1 = excellent, 2 = moderate, and 3 = poor/nondiagnostic). Quantitative image quality parameters (noise, contrast-to-noise ratio) were measured. Effective radiation doses were calculated. RESULTS: Mean HR was 76 +/- 19 bpm (range, 45-135 bpm). Median scan time was 0.9 seconds (range, 0.76-1.17 seconds), mean scan length was 349 +/- 38 mm (range, 294-452 mm). A total of 125 CABG (54% arterial grafts) and 465 vessel sections were analyzed. Twelve grafts were proximally occluded. Diagnostic image quality was obtained in 462 (99.4%) sections. Of those, image quality was excellent in 397 (85.4%) and moderate in 65 (14.0%). All 3 (0.6%) nondiagnostic sections affected the distal anastomosis due to motion artifacts caused by high HR. Separating the study population by the median HR of 71 bpm, image quality of the distal anastomosis regarding motion artifacts was significantly lower at high HR (P < 0.05). Interobserver agreement in grading image quality of graft segments was good (kappa = 0.77). Image noise in the aorta was 36.9 +/- 8.1, contrast-to-noise ratio was 13.1 +/- 4.2. Effective radiation dose was 2.3 +/- 0.3 mSv. CONCLUSIONS: The patency of coronary artery bypass grafts can be assessed with decreasing image quality at high HR in high-pitch prospectively ECG-synchronized thoracic 128-slice dual-source CT angiography at a low radiation dose.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Supervivencia de Injerto , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento , Grado de Desobstrucción Vascular
6.
Acad Radiol ; 17(4): 526-34, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20207320

RESUMEN

RATIONALE AND OBJECTIVES: To assess the performance of dual-energy computed tomography (DECT) equipped with the new tin filter technology to classify phantom renal lesions as cysts or enhancing masses. MATERIALS AND METHODS: Forty spherical lesion proxies ranging in diameter from 6 to 27 mm were filled with either distilled water (n = 10) representing cysts or titrated iodinated contrast solutions with a concentration of 0.45 (n = 10), 0.9 (n = 10), and 1.8 mg/mL (n = 10) representing enhancing masses. The lesion proxies were placed in a 12-cm diameter renal phantom containing minced beef and submerged in a 28-cm water bath. DECT was performed using the new dual-source CT system (Definition Flash, Siemens Healthcare, Forchheim, Germany) allowing for an improved energy separation by using a tin filter. DECT was performed at tube voltages of 140/80 kV without the tin filter (protocol A) and with tin filter (protocol B). The tube current time product was selected in each protocol to achieve a constant CTDI (computed tomography dose index) with both protocols of 19 mGy (full dose), 9.5 mGy (half dose), and 4.8 mGy (quarter dose). Two blinded readers classified each lesion as a cyst or enhancing mass by using iodine overlay (IO) images. One reader measured the CT numbers of each lesion at 120 kV, in the IO, linear blending (LB), and virtual noncontrast (VNC) images. RESULTS: The CT numbers of the lesions at 120 kV were 0.1 +/- 0.7 HU (0 mg iodine/mL), 9.1 +/- 0.7 HU (0.45 mg/mL), 18.1 +/- 1.4 HU (0.9 mg/mL), and 37.6 +/- 1.6 HU (1.8 mg/mL). Mean diameter of the lesion proxies filled with water or different iodine concentrations was similar (P = 0.38). Image noise was not significantly different in protocols A and B at the corresponding dose levels. At full dose, protocol A had a sensitivity of 93% and a specificity of 60% for discriminating renal lesions. Sensitivity and specificity declined to 84% and 38% at quarter dose. In protocol B, sensitivity was 100% and specificity was 90% at full dose and 93% and 70% at quarter dose. All misclassifications occurred in cyst or low iodine concentration (0.45 mg/mL) lesion proxies. The differences between CT numbers at 120 kV and in the IO, VNC, and AW (average weighted) images were significantly lower in protocol B compared to protocol A (each P < .05). CONCLUSIONS: DECT using the tin filter results in an improved sensitivity and specificity for discriminating renal cysts from enhancing masses in a kidney phantom model and demonstrates higher dose efficiency as compared to former dual energy technology without tin filters.


Asunto(s)
Filtración/instrumentación , Neoplasias Renales/diagnóstico por imagen , Enfermedades Renales Poliquísticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Diagnóstico Diferencial , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
AJR Am J Roentgenol ; 194(4): 938-44, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20308495

RESUMEN

OBJECTIVE: The purpose of this study was to prospectively evaluate the average heart rate and heart rate variability required for diagnostic imaging of the coronary arteries with high-pitch dual-source CT angiography of the thoracic and thoracoabdominal aorta. SUBJECTS AND METHODS: One hundred consecutively registered patients (82 men, 18 women; mean age, 68 +/- 13 years) underwent clinically indicated CT angiography of the thoracic (n = 33) and thoracoabdominal (n = 67) aorta with a dual-source 128-MDCT scanner in ECG-synchronized high-pitch (pitch, 3.2) data acquisition mode. No beta-blockers were administered. The image quality of the coronary arteries was graded on a 3-point scale by two independent blinded readers. The average heart rate and heart rate variability before data acquisition were noted. Effective radiation doses were calculated. RESULTS: Interobserver agreement on grade of image quality for the 1,414 coronary segments evaluated by both observers was good (kappa = 0.68). Diagnostic image quality was found for 1,375 of the 1,414 segments (97.2%) in 83 of 100 patients (83%). In 17% of the patients, image quality was nondiagnostic for at least one coronary artery segment. Average heart rate and heart rate variability (each p < 0.05) were significantly higher in patients with at least one nondiagnostic coronary segment compared with those without. All patients with an average heart rate less than 63 beats/min and heart rate variability less than 1.2 beats/min had diagnostic image quality in all coronary segments. Effective radiation doses were 2.3 +/- 0.3 mSv for thoracic and 4.4 +/- 0.5 mSv for thoracoabdominal CT angiography. The average scan times were 0.88 +/- 0.06 second for thoracic and 1.67 +/- 0.15 seconds for thoracoabdominal CT angiography. CONCLUSION: For patients with an average heart rate less than 63 beats/min and heart rate variability less than 1.2 beats/min, dual-source CT angiography of the thoracoabdominal aorta at a high pitch of 3.2 delivers diagnostic depiction of the coronary arteries at a low radiation dose.


Asunto(s)
Angiografía/métodos , Aorta Abdominal/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Tomografía Computarizada Espiral/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Artefactos , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Angiografía Coronaria , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Procedimientos Quirúrgicos Vasculares
8.
J Thorac Cardiovasc Surg ; 139(6): 1602-8, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19913239

RESUMEN

OBJECTIVES: The Cabrol procedure is characterized by insertion of an ascending aortic composite graft with reimplantation of the coronary arteries by the interposition of a graft tube. Our purpose is to report the clinical long-term follow-up and computed tomographic findings in patients having undergone the Cabrol procedure and to determine blood flow in the Cabrol graft using computational fluid dynamics. METHODS: Clinical follow-up (76.6 +/- 16.6 months) and dual-source computed tomographic angiography data of 7 patients (all men, mean age 54.9 +/- 9.6 years) with 12 Cabrol grafts (left main coronary artery, n = 7; right coronary artery, n = 5) were reviewed. In 2 patients, the right coronary artery was directly reattached to the aortic graft. Computational fluid dynamics were calculated using computed tomographic data of a patient with the Cabrol procedure and compared with those in a Valsalva graft and a healthy aortic root. RESULTS: Computed tomography showed Cabrol graft occlusions to 1 of 7 (14%) left main and of 2 of 5 (40%) right coronary arteries. Six grafts to the left main and 3 to the right coronary artery were fully patent, similar to the 2 directly reattached right coronary arteries to the aortic graft. Computational fluid dynamics results show similar blood flow parameters into the coronaries for the healthy aortic root and Valsalva graft. In the Cabrol graft, a spiraling flow pattern with low flow into the right coronary artery was found (right coronary artery = 1 mL/min at both systole and diastole). CONCLUSIONS: Our study indicates low flow rates particularly in the right Cabrol graft correlating with a higher incidence of occlusions of the right as compared with the left Cabrol graft at long-term follow-up.


Asunto(s)
Aorta/cirugía , Válvula Aórtica/cirugía , Prótesis Vascular , Vasos Coronarios/cirugía , Tomografía Computarizada por Rayos X , Adulto , Anciano , Aortografía/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Estudios Retrospectivos , Factores de Tiempo , Procedimientos Quirúrgicos Vasculares/métodos
9.
Radiology ; 253(1): 56-64, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19587311

RESUMEN

PURPOSE: To compare the diagnostic performance and radiation doses of dual-source and 64-section computed tomographic (CT) coronary angiography for the diagnosis of significant coronary stenoses in patients with heart rates of 65 beats/min or less. MATERIALS AND METHODS: This retrospective study had local ethics committee approval; all patients gave written informed consent. Two hundred patients with heart rates of 65 beats/min or less were enrolled; 100 underwent dual-source and 100 underwent 64-section CT coronary angiography. Two blinded observers independently assessed image quality of all coronary segments by using a four-point scale and searched for significant (>50%) stenoses in each segment. Catheter angiography was used as the reference standard. Image noise was measured in the ascending aorta. Radiation doses were calculated. RESULTS: No significant differences were found regarding sex, age, body weight, cardiovascular risk profile, prevalence of stenosis, mean and variability of heart rate, Agatston score, and image noise (all P > .1) between patients in both CT coronary angiography groups. No significant difference was found in the rate of nonassessable coronary segments between dual-source (1.0%, 14 of 1405) and 64-section CT coronary angiography (1.8%, 25 of 1387; P = .08). Motion artifacts occurred significantly more often in 64-section (21 of 25) versus dual-source (five of 14, P = .004) CT coronary angiography. Segment-based accuracy and specificity were significantly higher for dual-source versus 64-section CT coronary angiography. There was no significant difference in accuracy parameters at the per-vessel and per-patient analyses. No significant difference (P = .13) was found between the effective doses of dual-source (mean +/- standard deviation, 10.9 mSv +/- 1.1) and 64-section CT (10.4 mSv +/- 1.7) coronary angiography. CONCLUSION: In patients with heart rates of 65 beats/min or less, the higher temporal resolution of dual-source CT coronary angiography results in improved accuracy and specificity for the diagnosis of significant stenoses on a per-segment level at a similar radiation dose, but provides a comparable diagnostic accuracy on a patient-based level as does 64-section coronary angiography.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Distribución de Chi-Cuadrado , Medios de Contraste , Estenosis Coronaria/fisiopatología , Electrocardiografía , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Estadísticas no Paramétricas
10.
AJR Am J Roentgenol ; 191(6): 1684-9, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19020236

RESUMEN

OBJECTIVE: The purpose of this study was to investigate the diagnostic accuracy of dual-source CT coronary angiography with prospective ECG triggering compared with catheter angiography and to determine the influence of vessel wall calcifications. SUBJECTS AND METHODS: One hundred consecutive patients (42 women and 58 men; mean age, 65.8 +/- 6.5 years) with a sinus rhythm and heart rates < 70 beats per minute were included. Two independent, blinded readers classified coronary artery segments as being of diagnostic or nondiagnostic image quality and assessed each segment with diagnostic image quality for the presence of significant coronary stenoses. Nondiagnostic segments were excluded from analysis. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for all patients and for the subgroup of patients with a low or high calcium score (group A, median Agatston score < 316; group B, > or = 316). Catheter angiography was used as the reference standard. Effective radiation dose values were calculated. RESULTS: In 89 of 100 patients (89%), 1,462 of 1,524 coronary segments (96%) were depicted with diagnostic image quality. The overall sensitivity, specificity, PPV, and NPV were 98%, 99%, 95%, and 100%, respectively. The rate of segments with nondiagnostic image quality was significantly higher (p < 0.001) in group B compared with group A. In group A, sensitivity, specificity, PPV, and NPV were 99%, 99%, 94%, and 100%, respectively, and in group B, 98%, 99%, 94%, and 99%, respectively, with no significant differences between the groups. The average effective radiation dose was 2.6 +/- 0.8 mSv (range, 1.2-4.4 mSv). CONCLUSION: Dual-source CT coronary angiography with use of prospective ECG triggering performs accurately in the assessment of coronary artery disease at low radiation doses. Diagnostic accuracy remains high despite the presence of heavy calcifications but is associated with an increased rate of nondiagnostic segments.


Asunto(s)
Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/etiología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Eur J Radiol ; 68(3): 385-91, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18976876

RESUMEN

OBJECTIVE: To determine the radiation doses and image quality of different dual-source computed tomography coronary angiography (CTCA) protocols tailored to the heart rate (HR) and body mass index (BMI) of the patients. MATERIALS AND METHODS: Two hundred consecutive patients (68 women; mean age 61+/-9 years) underwent either helical CTCA with retrospective ECG-gating or sequential CT with prospective ECG-triggering: 50 patients (any BMI, any HR) were examined with a standard, non-tailored protocol (helical CTCA, 120 kV, 330 mAs), whereas the other 150 patients were examined with a tailored protocol: 40 patients (group A, BMI70 bpm) with helical CTCA (100 kV, 220 mAs), 28 patients (group C, BMI>25 kg/sqm, HR25 kg/sqm, HR>70 bpm) with helical CTCA (120 kV, 330 mAs). The effective radiation dose estimates were calculated from the dose-length-product for each patient. Image quality was classified as being diagnostic or non-diagnostic in each coronary segment. RESULTS: Image quality was diagnostic in 2403/2460 (98%) and non-diagnostic in 57/2460 (2%) of all coronary segments. No significant differences in image quality were found among all five CTCA protocols (p=0.78). The non-tailored helical CTCA protocol was associated with a radiation dose of 9.0+/-1.0 mSv, being significantly higher compared to that using sequential CTCA (group A: 1.3+/-0.3 mSv, p<0.001; group C: 2.9+/-0.6 mSv, p<0.001), and helical CTCA at reduced tube voltage and tube current (group B: 4.2+/-0.6 mSv, p<0.01). No significant differences were found compared to the non-tailored CTCA protocol in patients with HR>70 bpm (group D: 8.5+/-0.9 mSv, p=0.51). CONCLUSIONS: Dual-source CTCA is associated with radiation doses ranging between 1.3 and 9.0 mSv, depending on the protocol used. Tailoring of the CTCA protocol to the HR and BMI of the individual patient results in dose reductions of up to 86%, while maintaining a diagnostic image quality of the examination.


Asunto(s)
Carga Corporal (Radioterapia) , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Radiometría , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Plast Reconstr Surg ; 117(6): 2043-9, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16651982

RESUMEN

BACKGROUND: The classic concept of axillary glands differentiates between eccrine glands, producing abundant clear, nonodorous sweat; and apocrine glands, excreting small amounts of turbid, odorous milky sweat. A third type of sweat glands, the "apoeccrine" glands, were recently identified. To define the different types of sweat glands and their location and number, the authors carried out a prospective histologic study on adult human axillary skin, including various immunohistochemical markers. METHODS: Forty-three consecutive Caucasian, subjectively normhidrotic patients, who underwent a surgical procedure in the axilla unrelated to the axillary glands, were included in the study. For verification of normhidrosis, the gravimetric test was carried out by measuring the amount of sweat secretion per minute. Then, a 1 x 1-cm measuring piece of skin and subcutaneous tissue was excised in the apex of the axilla, divided into three samples--altogether, 129 samples--and processed for histologic examination. RESULTS: In the dermis, the authors found only very few eccrine (average, 0.3 gland/cm in only 12 percent of all patients) and apocrine glands (average, 0.1 gland/cm in only 4.7 percent of patients), and no apoeccrine glands in any patient. In the subcutaneous tissue, the mean number of glands per centimeter squared was 10 for the eccrine glands, nine for the apocrine glands, and six for the apoeccrine glands. CONCLUSIONS: In the authors' Caucasian subjects, all or most of the sweat glands were found in the subcutaneous tissue near the border to the dermis and not in the dermis. For extremely hyperfunctioning sweat glands, the authors recommend less radical surgical methods, with the preservation of skin, based on the knowledge that most glands are localized in the subcutaneous tissue.


Asunto(s)
Axila/anatomía & histología , Glándulas Sudoríparas/anatomía & histología , Adulto , Anciano , Glándulas Apocrinas/anatomía & histología , Glándulas Apocrinas/química , Glándulas Apocrinas/metabolismo , Biomarcadores , Proteínas Portadoras/análisis , Dermis/anatomía & histología , Glándulas Ecrinas/anatomía & histología , Glándulas Ecrinas/química , Glándulas Ecrinas/metabolismo , Femenino , Glicoproteínas/análisis , Humanos , Antígeno Lewis X/análisis , Escisión del Ganglio Linfático , Metástasis Linfática , Masculino , Melanoma/secundario , Melanoma/cirugía , Proteínas de Transporte de Membrana , Persona de Mediana Edad , Especificidad de Órganos , Proteínas S100/análisis , Tejido Subcutáneo/anatomía & histología , Sudor/metabolismo , Glándulas Sudoríparas/química , Glándulas Sudoríparas/metabolismo , Sudoración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA