Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Biomed Opt ; 29(2): 020502, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38361504

RESUMEN

Significance: There has been significant interest in the development of miniature photoacoustic imaging probes for a variety of clinical uses, including the in situ assessment of tumors and minimally invasive surgical guidance. Most of the previously implemented probes are either side viewing or operate in the optical-resolution microscopy mode in which the imaging depth is limited to ∼1 mm. We describe a forward-viewing photoacoustic probe that operates in tomography mode and simultaneously provides white light video images. Aim: We aim to develop a dual-modality endoscope capable of performing high-resolution PAT imaging and traditional white light videoscopy simultaneously in the forward-viewing configuration. Approach: We used a Fabry-Pérot ultrasound sensor that operates in the 1500 to 1600 nm wavelength range and is transparent in the visible and near infrared region (580 to 1250 nm). The FP sensor was optically scanned using a miniature MEMs mirror located at the proximal end of the endoscope, resulting in a system that is sufficiently compact (10 mm outer diameter) and lightweight for practical endoscopic use. Results: The imaging performance of the endoscope is evaluated, and dual-mode imaging capability is demonstrated using phantoms and abdominal organs of an ex vivo mouse including spleen, liver, and kidney. Conclusions: The proposed endoscope design offers several advantages including the high acoustic sensitivity and wide detection bandwidth of the FP sensor, dual-mode imaging capability, compact footprint, and an all-optical distal end for improved safety. The dual-mode imaging capability also offers the advantage of correlating the tissue surface morphology with the underlying vascular anatomy. Potential applications include the guidance of laparoscopic surgery and other interventional procedures.


Asunto(s)
Técnicas Fotoacústicas , Ratones , Animales , Técnicas Fotoacústicas/métodos , Endoscopios , Ultrasonografía , Microscopía , Endoscopía
2.
Bioorg Med Chem ; 91: 117412, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37473615

RESUMEN

Semiconducting polymer nanoparticles (SPN), formulated from organic semiconducting polymers and lipids, show promise as exogenous contrast agents for photoacoustic imaging (PAI). To fully realise the potential of this class of nanoparticles for imaging and therapeutic applications, a broad range of active targeting strategies, where ligands specific to receptors on the target cells are displayed on the SPN surface, are urgently needed. In addition, effective strategies for quantifying the level of surface modification are also needed to support development of ligand-targeted SPN. In this paper, we have developed methods to prepare SPN bearing peptides targeted to Epidermal Growth Factor Receptors (EGFR), which are overexpressed at the surface of a wide variety of cancer cell types. In addition to fully characterising these targeted nanoparticles by standard methods (UV-visible, photoacoustic absorption, dynamic light scattering, zeta potential and SEM), we have developed a powerful new NMR method to determine the degree of conjugation and the number of targeting peptides attached to the SPN. Preliminary in vitro experiments with the colorectal cancer cell line LIM1215 indicated that the EGFR-targeting peptide conjugated SPN were either ineffective in delivering the SPN to the cells, or that the targeting peptide itself destabilised the formulation. This in reinforces the need for effective characterisation techniques to measure the surface accessibility of targeting ligands attached to nanoparticles.


Asunto(s)
Nanopartículas , Técnicas Fotoacústicas , Polímeros/química , Receptores ErbB , Técnicas Fotoacústicas/métodos , Ligandos , Nanopartículas/química
3.
Biomed Opt Express ; 14(7): 3446-3457, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37497509

RESUMEN

All-optical ultrasound (OpUS) has emerged as an imaging paradigm well-suited to minimally invasive imaging due to its ability to provide high resolution imaging from miniaturised fibre optic devices. Here, we report a fibre optic device capable of concurrent laser interstitial thermal therapy (LITT) and real-time in situ all-optical ultrasound imaging for lesion monitoring. The device comprised three optical fibres: one each for ultrasound transmission, reception and thermal therapy light delivery. This device had a total lateral dimension of <1 mm and was integrated into a medical needle. Simultaneous LITT and monitoring were performed on ex vivo lamb kidney with lesion depth tracked using M-mode OpUS imaging. Using one set of laser energy parameters for LITT (5 W, 60 s), the lesion depth varied from 3.3 mm to 8.3 mm. In all cases, the full lesion depth could be visualised and measured with the OpUS images and there was a good statistical agreement with stereomicroscope images acquired after ablation (t=1.36, p=0.18). This work demonstrates the feasibility and potential of OpUS to guide LITT in tumour resection.

4.
Cancer Res ; 83(12): 2077-2089, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-36934744

RESUMEN

Fluorescence-guided surgery is set to play a pivotal role in the intraoperative management of pediatric tumors. Shortwave infrared imaging (SWIR) has advantages over conventional near-infrared I (NIR-I) imaging with reduced tissue scattering and autofluorescence. Here, two NIR-I dyes (IRDye800CW and IR12), with long tails emitting in the SWIR range, were conjugated with a clinical-grade anti-GD2 monoclonal antibody (dinutuximab-beta) to compare NIR-I and SWIR imaging for neuroblastoma surgery. A first-of-its-kind multispectral NIR-I/SWIR fluorescence imaging device was constructed to allow an objective comparison between the two imaging windows. Conjugates were first characterized in vitro. Tissue-mimicking phantoms, imaging specimens of known geometric and material composition, were used to assess the sensitivity and depth penetration of the NIR-I/SWIR device, showing a minimum detectable volume of ∼0.9 mm3 and depth penetration up to 3 mm. In vivo, fluorescence imaging using the NIR-I/SWIR device showed a high tumor-to-background ratio (TBR) for both dyes, with anti-GD2-IR800 being significantly brighter than anti-GD2-IR12. Crucially, the system enabled higher TBR at SWIR wavelengths than at NIR-I wavelengths, verifying SWIR imaging enables high-contrast delineation of tumor margins. This work demonstrates that by combining the high specificity of anti-GD2 antibodies with the availability and translatability of existing NIR-I dyes, along with the advantages of SWIR in terms of depth and tumor signal-to-background ratio, GD2-targeted NIR-I/SWIR-guided surgery could improve the treatment of patients with neuroblastoma, warranting investigation in future clinical trials. SIGNIFICANCE: Multispectral near-infrared I/shortwave infrared fluorescence imaging is a versatile system enabling high tumor-to-background signal for safer and more complete resection of pediatric tumors during surgery.


Asunto(s)
Antineoplásicos , Neuroblastoma , Niño , Humanos , Imagen Óptica/métodos , Neuroblastoma/diagnóstico por imagen , Neuroblastoma/cirugía , Fantasmas de Imagen , Colorantes , Colorantes Fluorescentes
5.
Cancers (Basel) ; 15(3)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36765874

RESUMEN

Despite aggressive treatments, the prognosis of high-risk NB remains poor. Surgical oncology needs innovative intraoperative devices to help surgeons discriminate malignant tissue from necrotic and surrounding healthy tissues. Changes within the tumor vasculature could be used intraoperatively as a diagnostic tool to guide surgical resection. Here, we retrospectively analyzed the mean vascular density (MVD) of different NB subtypes at diagnosis and after induction chemotherapy using scanned histological samples. One patient was prospectively enrolled, and an ex vivo photoacoustic imaging (PAI) scan was performed on two representative sections to assess its capacity to discriminate different tumor regions. We found that post-chemotherapy, viable areas of differentiating NBs and ganglioneuroblastomas are associated with higher MVD compared to poorly differentiated NBs. Early necrotic regions showed higher MVD than late necrotic and viable regions. Finally, calcified areas showed significantly lower MVD than any other histological component. The acquired PAI images showed a good high-resolution ex vivo 3D delineation of NB margins. Overall, these results suggest that a high-definition preclinical imaging device such as PAI could potentially be exploited to guide surgical resection by identifying different vasculature signatures.

6.
Sensors (Basel) ; 22(23)2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36501738

RESUMEN

Ultrasound is an essential tool for guidance of many minimally-invasive surgical and interventional procedures, where accurate placement of the interventional device is critical to avoid adverse events. Needle insertion procedures for anaesthesia, fetal medicine and tumour biopsy are commonly ultrasound-guided, and misplacement of the needle may lead to complications such as nerve damage, organ injury or pregnancy loss. Clear visibility of the needle tip is therefore critical, but visibility is often precluded by tissue heterogeneities or specular reflections from the needle shaft. This paper presents the in vitro and ex vivo accuracy of a new, real-time, ultrasound needle tip tracking system for guidance of fetal interventions. A fibre-optic, Fabry-Pérot interferometer hydrophone is integrated into an intraoperative needle and used to localise the needle tip within a handheld ultrasound field. While previous, related work has been based on research ultrasound systems with bespoke transmission sequences, the new system-developed under the ISO 13485 Medical Devices quality standard-operates as an adjunct to a commercial ultrasound imaging system and therefore provides the image quality expected in the clinic, superimposing a cross-hair onto the ultrasound image at the needle tip position. Tracking accuracy was determined by translating the needle tip to 356 known positions in the ultrasound field of view in a tank of water, and by comparison to manual labelling of the the position of the needle in B-mode US images during an insertion into an ex vivo phantom. In water, the mean distance between tracked and true positions was 0.7 ± 0.4 mm with a mean repeatability of 0.3 ± 0.2 mm. In the tissue phantom, the mean distance between tracked and labelled positions was 1.1 ± 0.7 mm. Tracking performance was found to be independent of needle angle. The study demonstrates the performance and clinical compatibility of ultrasound needle tracking, an essential step towards a first-in-human study.


Asunto(s)
Tecnología de Fibra Óptica , Agujas , Embarazo , Femenino , Humanos , Ultrasonografía , Fantasmas de Imagen , Agua , Ultrasonografía Intervencional/métodos
7.
Biomed Opt Express ; 13(8): 4414-4428, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36032566

RESUMEN

Photoacoustic (PA) endoscopy has shown significant potential for clinical diagnosis and surgical guidance. Multimode fibres (MMFs) are becoming increasingly attractive for the development of miniature endoscopy probes owing to their ultrathin size, low cost and diffraction-limited spatial resolution enabled by wavefront shaping. However, current MMF-based PA endomicroscopy probes are either limited by a bulky ultrasound detector or a low imaging speed that hindered their usability. In this work, we report the development of a highly miniaturised and high-speed PA endomicroscopy probe that is integrated within the cannula of a 20 gauge medical needle. This probe comprises a MMF for delivering the PA excitation light and a single-mode optical fibre with a plano-concave microresonator for ultrasound detection. Wavefront shaping with a digital micromirror device enabled rapid raster-scanning of a focused light spot at the distal end of the MMF for tissue interrogation. High-resolution PA imaging of mouse red blood cells covering an area 100 µm in diameter was achieved with the needle probe at ∼3 frames per second. Mosaicing imaging was performed after fibre characterisation by translating the needle probe to enlarge the field-of-view in real-time. The developed ultrathin PA endomicroscopy probe is promising for guiding minimally invasive surgery by providing functional, molecular and microstructural information of tissue in real-time.

8.
Ultrasound Med Biol ; 48(3): 520-529, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34974926

RESUMEN

Accurate identification of the needle tip is a key challenge with ultrasound-guided percutaneous interventions in regional anaesthesia, foetal surgery and cardiovascular medicine. In this study, we developed an ultrasonic needle tracking system in which the measured needle tip location was used to set the electronic focus of the external ultrasound imaging probe. In this system, needle tip tracking was enabled with a fibre-optic ultrasound sensor that was integrated into a needle stylet, and the A-lines recorded by the sensor were processed to generate tracking images of the needle tip. The needle tip position was estimated from the tracking images. The dependency of the tracking image on the electronic focal depth of the external ultrasound imaging probe was studied in a water bath and with needle insertions into a clinical training phantom. The variability in the estimated tracked position of the needle tip, with the needle tip at fixed depths in the imaging plane across a depth range from 0.5 to 7.5 cm, was studied. When the electronic focus was fixed, the variability of tracked position was found to increase with distance from that focus. The variability with the fixed focus was found to depend on the the relative distance between the needle tip and focal depth. It was found that with dynamic focusing, the maximum variability of tracked position was below 0.31 mm, as compared with 3.97 mm for a fixed focus.


Asunto(s)
Agujas , Ultrasonido , Electrónica , Fantasmas de Imagen , Ultrasonografía , Ultrasonografía Intervencional/métodos
9.
Opt Lett ; 45(22): 6238-6241, 2020 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-33186959

RESUMEN

A miniature flexible photoacoustic endoscopy probe that provides high-resolution 3D images of vascular structures in the forward-viewing configuration is described. A planar Fabry-Perot ultrasound sensor with a -3dB bandwidth of 53 MHz located at the tip of the probe is interrogated via a flexible fiber bundle and a miniature optical relay system to realize an all-optical probe measuring 7.4 mm in outer diameter at the tip. This approach to photoacoustic endoscopy offers advantages over previous piezoelectric based distal-end scanning probes. These include a forward-viewing configuration in widefield photoacoustic tomography mode, finer spatial sampling (87 µm spatial sampling interval), and wider detection bandwidth (53 MHz) than has been achievable with conventional ultrasound detection technology and an all-optical passive imaging head for safe endoscopic use.


Asunto(s)
Endoscopios , Miniaturización/instrumentación , Fibras Ópticas , Técnicas Fotoacústicas/instrumentación , Cirugía Asistida por Computador/instrumentación , Diseño de Equipo , Fenómenos Mecánicos , Seguridad , Tomografía
10.
Sci Rep ; 10(1): 7514, 2020 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-32372054

RESUMEN

Cell-based therapies are promising treatments for various kidney diseases. However, the major hurdle in initiating therapeutic responses is the inefficiency of injection routes to deliver cells to the kidney parenchyma. Systemic injection, such as intravenous injection only delivers a small proportion of cells to the kidney. Whereas direct delivery, such as renal artery injection requires surgical procedures. A minimally invasive renal artery injection was therefore developed to enhance cell delivery to kidney. In this study, luciferase expressing human adipocyte derived stem cells (ADSC) were labelled with gold nanorods (GNR) and injected into the renal artery using ultrasound guidance. The ADSCs were tracked using bioluminescence and photoacoustic imaging serially over 7 days. Imaging confirmed that the majority of signal was within the kidney, indicative of successful injection and that the cells remained viable for 3 days. Histology showed co-localization of GNRs with ADSC staining throughout the kidney with no indication of injury caused by injection. These findings demonstrate that ultrasound-guided renal artery injection is feasible in mice and can successfully deliver a large proportion of cells which are retained within the kidney for 3 days. Therefore, the techniques developed here will be useful for optimising cell therapy in kidney diseases.


Asunto(s)
Adipocitos/citología , Oro/química , Enfermedades Renales/diagnóstico por imagen , Trasplante de Células Madre Mesenquimatosas/métodos , Nanopartículas del Metal/química , Arteria Renal/diagnóstico por imagen , Animales , Diferenciación Celular , Proliferación Celular , Condrocitos/citología , Células HEK293 , Humanos , Células Madre Mesenquimatosas/citología , Ratones , Osteogénesis , Técnicas Fotoacústicas , Ultrasonografía
11.
J Biomed Opt ; 25(4): 1-12, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32314561

RESUMEN

SIGNIFICANCE: Green-fluorescent protein (GFP)-like fluorescent proteins are used extensively as genetic reporters in fluorescence imaging due to their distinctive ability to form chromophores independent of external enzymes or cofactors. However, their use for photoacoustic (PA) imaging has not been demonstrated in mammalian tissues because they possess low PA signal generation efficiency in their native state. By engineering them to become nonfluorescent (NF), their PA generation efficiency was increased. This enabled the generation of in vivo contrast in mice, making it possible for GFP-like proteins to be used as PA genetic reporters in mammalian tissues. AIM: The aim was to develop a darkened GFP-like protein reporter by modifying E2 crimson fluorescent protein (FP) in order to generate NF mutant proteins with high PA signal generation efficiency for in vivo imaging. APPROACH: The absorbance, fluorescence, and PA amplitude spectra of purified protein solutions of the FP and engineered NF mutants were measured in order to identify the mutant with the highest PA signal generation efficiency. This mutant, referred to as NFA, and the native FP were then stably expressed in LS174T human colorectal tumor cells using a retroviral vector and tested for photostability under continuous pulsed illumination. To demonstrate the improvement in PA signal generation in vivo, cells expressing the FP and NFA mutant were injected subcutaneously in mice and imaged using a Fabry-Perot based PA scanner. RESULTS: The NF mutants of E2 crimson exhibited fluorescence that was 2 orders of magnitude lower than the FP and a higher PA signal generation efficiency; the NFA-generated PA signal was approximately three times higher than the FP. Tumor cells expressing the NFA mutant provided sufficient image contrast to be visualized in vivo against a background of strong vascular contrast, whereas the FP-expressing cells did not generate visible contrast. CONCLUSION: A GFP-like protein has been demonstrated as a genetic reporter for PA imaging in mammalian tissue for the first time. This was achieved by a mutation, which darkened the FP and increased the PA signal generation efficiency. The approach taken suggests that GFP-like proteins could be a promising addition to the current cohort of genetic reporters available for in vivo PA imaging.


Asunto(s)
Técnicas Fotoacústicas , Animales , Diagnóstico por Imagen , Proteínas Fluorescentes Verdes/genética , Proteínas Luminiscentes/genética , Ratones
12.
J Biophotonics ; 13(4): e201900167, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31661594

RESUMEN

Minimally invasive fetal interventions require accurate imaging from inside the uterine cavity. Twin-to-twin transfusion syndrome (TTTS), a condition considered in this study, occurs from abnormal vascular anastomoses in the placenta that allow blood to flow unevenly between the fetuses. Currently, TTTS is treated fetoscopically by identifying the anastomosing vessels, and then performing laser photocoagulation. However, white light fetoscopy provides limited visibility of placental vasculature, which can lead to missed anastomoses or incomplete photocoagulation. Photoacoustic (PA) imaging is an alternative imaging method that provides contrast for hemoglobin, and in this study, two PA systems were used to visualize chorionic (fetal) superficial and subsurface vasculature in human placentas. The first system comprised an optical parametric oscillator for PA excitation and a 2D Fabry-Pérot cavity ultrasound sensor; the second, light emitting diode arrays and a 1D clinical linear-array ultrasound imaging probe. Volumetric photoacoustic images were acquired from ex vivo normal term and TTTS-treated placentas. It was shown that superficial and subsurface branching blood vessels could be visualized to depths of approximately 7 mm, and that ablated tissue yielded negative image contrast. This study demonstrated the strong potential of PA imaging to guide minimally invasive fetal therapies.


Asunto(s)
Transfusión Feto-Fetal , Técnicas Fotoacústicas , Femenino , Transfusión Feto-Fetal/cirugía , Fetoscopía , Humanos , Coagulación con Láser , Placenta/diagnóstico por imagen , Embarazo , Ultrasonografía
13.
Clin Cancer Res ; 25(24): 7436-7447, 2019 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-31551349

RESUMEN

PURPOSE: Photoacoustic imaging (PAI) is a novel noninvasive and nonionizing imaging technique that allows longitudinal imaging of tumor vasculature in vivo and monitoring of response to therapy, especially for vascular targeted chemotherapy agents. In this study, we used a novel high-resolution all-optical PAI scanner to observe the pharmacodynamic response to the vascular-disrupting agent OXi4503. EXPERIMENTAL DESIGN: Two models of colorectal carcinoma (SW1222 and LS174T) that possess differing pathophysiologic vascularization were established as subcutaneous tumors in mice. Monitoring of response was performed over a 16-day "regrowth" period following treatment at 40 mg/kg, and at day 2 for a "dose response" study at 40 mg/kg, 10 mg/kg, 1 mg/kg, and sham dose. RESULTS: Qualitative and quantitative changes in PA signal are observed, with an initial decrease followed by a plateau and subsequent return of signal indicating regrowth. Both tumor types exhibited a decrease in signal; however, the more vascularized SW1222 tumors show greater response to treatment. Decreasing the dose of OXi4503 led to a decrease in PA signal intensity of 60%, 52%, and 20% in SW1222 tumors and 30%, 26%, and 4% for LS174T tumors. CONCLUSIONS: We have shown for the first time that PAI can observe the pharmacodynamic response of tumor vasculature to drug treatment both longitudinally and at different dose levels. Assessment of differing response to treatment based on vascular pathophysiologic differences among patients has the potential to provide personalized drug therapy; we have demonstrated that PAI, which is clinically translatable, could be a powerful tool for this purpose.


Asunto(s)
Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/tratamiento farmacológico , Difosfatos/farmacología , Imagen Molecular/métodos , Neovascularización Patológica/tratamiento farmacológico , Técnicas Fotoacústicas/métodos , Estilbenos/farmacología , Animales , Línea Celular Tumoral , Neoplasias Colorrectales/patología , Relación Dosis-Respuesta a Droga , Femenino , Estudios Longitudinales , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Neovascularización Patológica/diagnóstico por imagen , Neovascularización Patológica/patología , Ensayos Antitumor por Modelo de Xenoinjerto
14.
Light Sci Appl ; 7: 75, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30323927

RESUMEN

A miniature forward-viewing endoscopic probe that provides high-resolution 3D photoacoustic images is demonstrated. The probe is of outer diameter 3.2 mm and comprised of a transparent Fabry-Pérot (FP) polymer-film ultrasound sensor that is located at the distal end of a rigid optical fiber bundle. Excitation laser pulses are coupled simultaneously into all cores of the bundle and are transmitted through the FP sensor to provide wide-field tissue illumination at the distal end. The resulting photoacoustic waves are mapped in 2D by sequentially scanning the input end of the bundle with an interrogation laser beam in order to individually address different points on the FP sensor. In this way, the sensor acts as a high-density ultrasound array that is comprised of 50,000 individual elements, each of which is 12 µm in diameter, within the 3.2 mm diameter footprint of the probe. The fine spatial sampling that this affords, along with the wide bandwidth (f -3dB = 34 MHz) of the sensor, enables a high-resolution photoacoustic image to be reconstructed. The measured on-axis lateral resolution of the probe was depth-dependent and ranged from 45-170 µm for depths between 1 and 7 mm, and the vertical resolution was 31 µm over the same depth range. The system was evaluated by acquiring 3D images of absorbing phantoms and the microvascular anatomies of a duck embryo and mouse skin. Excellent image fidelity was demonstrated. It is anticipated that this type of probe could find application as a tool for guiding laparoscopic procedures, fetal surgery and other minimally invasive interventions that require a millimeter-scale forward-viewing 3D photoacoustic imaging probe.

15.
Bioconjug Chem ; 28(6): 1734-1740, 2017 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-28561568

RESUMEN

Photoacoustic imaging combines both excellent spatial resolution with high contrast and specificity, without the need for patients to be exposed to ionizing radiation. This makes it ideal for the study of physiological changes occurring during tumorigenesis and cardiovascular disease. In order to fully exploit the potential of this technique, new exogenous contrast agents with strong absorbance in the near-infrared range, good stability and biocompatibility, are required. In this paper, we report the formulation and characterization of a novel series of endogenous contrast agents for photoacoustic imaging in vivo. These contrast agents are based on a recently reported series of indigoid π-conjugated organic semiconductors, coformulated with 1,2-dipalmitoyl-sn-glycero-3-phosphocholine, to give semiconducting polymer nanoparticles of about 150 nm diameter. These nanoparticles exhibited excellent absorption in the near-infrared region, with good photoacoustic signal generation efficiencies, high photostability, and extinction coefficients of up to three times higher than those previously reported. The absorption maximum is conveniently located in the spectral region of low absorption of chromophores within human tissue. Using the most promising semiconducting polymer nanoparticle, we have demonstrated wavelength-dependent differential contrast between vasculature and the nanoparticles, which can be used to unambiguously discriminate the presence of the contrast agent in vivo.


Asunto(s)
Medios de Contraste/química , Imagen Molecular/métodos , Nanopartículas/química , Técnicas Fotoacústicas/métodos , Vasos Sanguíneos/diagnóstico por imagen , Humanos , Polímeros/química , Semiconductores , Espectroscopía Infrarroja Corta
16.
Biomed Opt Express ; 7(7): 2789-806, 2016 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-27446707

RESUMEN

Acoustic resolution photoacoustic Doppler velocimetry promises to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Despite successful implementation using blood-mimicking fluids, measurements in blood have proved challenging, thus preventing in vivo application. A common explanation for this difficulty is that whole blood is insufficiently heterogeneous relative to detector frequencies of tens of MHz compatible with deep tissue photoacoustic measurements. Through rigorous experimental measurements we provide new insight that refutes this assertion. We show for the first time that, by careful choice of the detector frequency and field-of-view, and by employing novel signal processing methods, it is possible to make velocity measurements in whole blood using transducers with frequencies in the tens of MHz range. These findings have important implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions.

17.
J Biomed Opt ; 20(8): 86005, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26263417

RESUMEN

Precise device guidance is important for interventional procedures in many different clinical fields including fetal medicine, regional anesthesia, interventional pain management, and interventional oncology. While ultrasound is widely used in clinical practice for real-time guidance, the image contrast that it provides can be insufficient for visualizing tissue structures such as blood vessels, nerves, and tumors. This study was centered on the development of a photoacoustic imaging system for interventional procedures that delivered excitation light in the ranges of 750 to 900 nm and 1150 to 1300 nm, with an optical fiber positioned in a needle cannula. Coregistered B-mode ultrasound images were obtained. The system, which was based on a commercial ultrasound imaging scanner, has an axial resolution in the vicinity of 100 µm and a submillimeter, depth-dependent lateral resolution. Using a tissue phantom and 800 nm excitation light, a simulated blood vessel could be visualized at a maximum distance of 15 mm from the needle tip. Spectroscopic contrast for hemoglobin and lipids was observed with ex vivo tissue samples, with photoacoustic signal maxima consistent with the respective optical absorption spectra. The potential for further optimization of the system is discussed.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Imagen Molecular/instrumentación , Técnicas Fotoacústicas/instrumentación , Análisis Espectral/instrumentación , Cirugía Asistida por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
J Biomed Opt ; 20(5): 50504, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26008874

RESUMEN

Lymph nodes play a central role in metastatic cancer spread and are a key clinical assessment target. Abnormal node vascularization, morphology, and size may be indicative of disease but can be difficult to visualize with sufficient accuracy using existing clinical imaging modalities. To explore the potential utility of photoacoustic imaging for the assessment of lymph nodes, images of ex vivo samples were obtained at multiple wavelengths using a high-resolution three-dimensional photoacoustic scanner. These images showed that hemoglobin based contrast reveals nodal vasculature and lipid-based contrast reveals the exterior node size, shape, and boundary integrity. These two sources of complementary contrast may allow indirect observation of cancer, suggesting a future role for photoacoustic imaging as a tool for the clinical assessment of lymph nodes.


Asunto(s)
Hemoglobinas/análisis , Lípidos/análisis , Ganglios Linfáticos/química , Ganglios Linfáticos/citología , Imagen Molecular/métodos , Técnicas Fotoacústicas/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Técnicas In Vitro , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular , Tomografía/métodos
19.
Proc Natl Acad Sci U S A ; 112(7): 1959-64, 2015 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-25653336

RESUMEN

Gold quantum dots exhibit distinctive optical and magnetic behaviors compared with larger gold nanoparticles. However, their unfavorable interaction with living systems and lack of stability in aqueous solvents has so far prevented their adoption in biology and medicine. Here, a simple synthetic pathway integrates gold quantum dots within a mesoporous silica shell, alongside larger gold nanoparticles within the shell's central cavity. This "quantum rattle" structure is stable in aqueous solutions, does not elicit cell toxicity, preserves the attractive near-infrared photonics and paramagnetism of gold quantum dots, and enhances the drug-carrier performance of the silica shell. In vivo, the quantum rattles reduced tumor burden in a single course of photothermal therapy while coupling three complementary imaging modalities: near-infrared fluorescence, photoacoustic, and magnetic resonance imaging. The incorporation of gold within the quantum rattles significantly enhanced the drug-carrier performance of the silica shell. This innovative material design based on the mutually beneficial interaction of gold and silica introduces the use of gold quantum dots for imaging and therapeutic applications.


Asunto(s)
Oro/química , Imagen Multimodal , Puntos Cuánticos , Dióxido de Silicio/química , Células HeLa , Humanos , Microscopía Electrónica de Transmisión , Fototerapia
20.
Med Image Comput Comput Assist Interv ; 9349: 371-378, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28101537

RESUMEN

Image guidance plays a central role in minimally invasive fetal surgery such as photocoagulation of inter-twin placental anastomosing vessels to treat twin-to-twin transfusion syndrome (TTTS). Fetoscopic guidance provides insufficient sensitivity for imaging the vasculature that lies beneath the fetal placental surface due to strong light scattering in biological tissues. Incomplete photocoagulation of anastamoses is associated with postoperative complications and higher perinatal mortality. In this study, we investigated the use of multi-spectral photoacoustic (PA) imaging for better visualization of the placental vasculature. Excitation light was delivered with an optical fiber with dimensions that are compatible with the working channel of a fetoscope. Imaging was performed on an ex vivo normal term human placenta collected at Caesarean section birth. The photoacoustically-generated ultrasound signals were received by an external clinical linear array ultrasound imaging probe. A vein under illumination on the fetal placenta surface was visualized with PA imaging, and good correspondence was obtained between the measured PA spectrum and the optical absorption spectrum of deoxygenated blood. The delivery fiber had an attached fiber optic ultrasound sensor positioned directly adjacent to it, so that its spatial position could be tracked by receiving transmissions from the ultrasound imaging probe. This study provides strong indications that PA imaging in combination with ultrasonic tracking could be useful for detecting the human placental vasculature during minimally invasive fetal surgery.


Asunto(s)
Fetoscopía/métodos , Técnicas Fotoacústicas/métodos , Placenta/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Algoritmos , Femenino , Fetoscopios , Humanos , Placenta/irrigación sanguínea , Embarazo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA