Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
J Hand Surg Eur Vol ; 42(4): 338-345, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28399788

RESUMEN

The distal radioulnar joint allows the human to rotate the forearm to place the hand in a desired position to perform different tasks, without interfering with the grasping function of the hand. The ulna is the stable part of the forearm around which the radius rotates; the stability of the distal radioulnar joint is provided by the interaction between ligaments, muscles and bones. The stabilizing structures are the triangular fibrocartilage complex, the ulnocarpal ligament complex, the extensor carpi ulnaris tendon and tendon sheath, the pronator quadratus, the interosseous membrane and ligament, the bone itself and the joint capsule. The purpose of this review article is to present and illustrate the current understanding of the functional anatomy and pathomechanics of this joint.


Asunto(s)
Articulación de la Muñeca/anatomía & histología , Articulación de la Muñeca/fisiología , Antebrazo , Humanos , Ligamentos Articulares/anatomía & histología , Ligamentos Articulares/fisiología , Pronación , Supinación , Tendones/anatomía & histología , Tendones/fisiología
2.
Chir Main ; 33(1): 23-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24412134

RESUMEN

Although work has been published comparing the five most commonly used transplant techniques to the properties of the scapho-lunate interosseous ligament (SLIL), no study has been carried out which compares the biomechanical properties of the different bone-tissue-bone autografts to each other, using a standard methodology of testing. The hypothesis of this study was that mechanically significant differences in the material properties of commonly used bone-tissue-bone exist when compared to each other. We tested the dorsal part of the SLIL and the five most quoted transplants in the literature: capitate to trapezoid; trapezoid to second metacarpal; third metacarpal-carpal; dorsal capitate-hamate; 4-5 extensor retinaculum. For each transplant, we measured failure load, failure displacement, width, and thickness. Anova was used to compare the different results obtained and the level of significance attributed to P<0.05. Load to failure were: SLIL 94.3±42.86N; capitate to trapezoid 37.7±23.13N; trapezoid to second metacarpal 45.43±14.28N; third metacarpal-carpal 60.11±19.94N; dorsal capitate-hamate 63±25.51N; 4-5 retinaculum 15.67±10.7N. Only the dorsal capitate-hamate ligament showed to have no significant (P>0.05) difference in term of load to failure, all the others was significantly weaker (P<0.05). Previous biomechanical studies have identified the dorsal region of the SLIL as the most structurally and functionally important area of the SLIL. As a result, attention has been more specifically brought to the replacement of the dorsal portion of the SLIL. An attempt to achieve a reconstruction that reproduces more closely the SLIL has generated research on the use of bone-tissue-bone composite graft, several donor sites have been used in order to find the most similar. Our results suggest that, using a normalized method to compare the previously described grafts harvested at the wrist level, that the dorsal capitate-hamate ligament has the closest properties to the native dorsal scapho-lunate ligament.


Asunto(s)
Trasplante de Mano , Ligamentos Articulares/cirugía , Hueso Semilunar/cirugía , Procedimientos de Cirugía Plástica , Hueso Escafoides/cirugía , Autoinjertos , Fenómenos Biomecánicos , Humanos , Ensayo de Materiales , Procedimientos de Cirugía Plástica/métodos , Resultado del Tratamiento
3.
J Hand Surg Eur Vol ; 35(9): 740-5, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20427404

RESUMEN

Radioscapholunate arthrodesis is a salvage procedure indicated for osteoarthritis of the radiocarpal joint involving the lunate facet of the radius. This cadaver study examines changes in wrist motion resulting from radioscapholunate arthrodesis, and the effects of surgical techniques to improve the range of motion. Simulated radioscapholunate arthrodesis, distal scaphoidectomy and triquetrectomy were carried out sequentially on six cadaver forearms and measurements (maximum flexion/extension and radial/ulnar deviation) were taken in the intact situation and after each surgical step using a magnetic tracking device. Radioscapholunate arthrodesis diminishes the amplitudes of movements of the wrist in all directions, but range of motion in the radioscapholunate fused wrist improves after scaphoidectomy and improves further after triquetrectomy (88% of original flexion/extension and 98% of original radial/ulnar deviation). Radioscapholunate arthrodesis causes a significant change in kinematics between the hamate and the triquetrum in flexion/extension.


Asunto(s)
Hueso Semilunar/cirugía , Radio (Anatomía)/cirugía , Rango del Movimiento Articular/fisiología , Hueso Escafoides/cirugía , Hueso Piramidal/cirugía , Articulación de la Muñeca/fisiología , Anciano , Anciano de 80 o más Años , Artrodesis , Cadáver , Femenino , Hueso Ganchoso/fisiología , Humanos , Masculino , Movimiento/fisiología , Hueso Piramidal/fisiología
4.
Unfallchirurg ; 105(8): 688-98, 2002 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-12243014

RESUMEN

The most common method of treating the arthrotic distal radioulnar joint (DRUJ) is resection of the entire ulnar head (Darrach procedure). Complications related to instability of the distal forearm resulting from loss of the ulnar head are usually manifested by pain and weak grip strength and have remained the drawbacks of this procedure. In an attempt to mechanically stabilize the distal forearm, an endoprosthesis was developed to replace the ulnar head after Darrach resection. The purpose of this study was to: 1) evaluate the dynamic effects of the Darrach procedure on radioulnar convergence; and 2) evaluate the mechanical efficacy of two soft tissue stabilizing techniques (Pronator quadratus advancement flap and ECU/FCU tenodesis) for the unstable distal ulnar stump and 3) the stability after the implantation of an ulnar head endoprosthesis following a Darrach resection on radioulnar convergence. With a dynamic PC-controled forearm simulator the rotation of 7 fresh-frozen cadaver upper extremities was actively and passively performed while loading relevant muscles. Resultant total forearm torque and the 3-dimensional kinematics of the ulna, radius and third metacarpal were recorded simultaneously. The implantation of the ulnar head endoprosthesis effectively restored the stability of the DRUJ. There were significantly better results after the implantation of the prosthesis compared with the Darrach and the soft tissue stabilization procedures. This study provides laboratory validity to the option of implanting an ulnar head endoprosthesis as an attempt to stabilize the distal forearm after Darrach resection in lieu of performing soft tissue stabilization techniques.


Asunto(s)
Inestabilidad de la Articulación/cirugía , Prótesis Articulares , Osteoartritis/cirugía , Complicaciones Posoperatorias/cirugía , Fracturas del Radio/cirugía , Colgajos Quirúrgicos/fisiología , Tendones/cirugía , Cúbito/cirugía , Traumatismos de la Muñeca/cirugía , Articulación de la Muñeca/cirugía , Fenómenos Biomecánicos , Simulación por Computador , Humanos , Inestabilidad de la Articulación/fisiopatología , Osteoartritis/fisiopatología , Complicaciones Posoperatorias/fisiopatología , Diseño de Prótesis , Fracturas del Radio/fisiopatología , Rango del Movimiento Articular/fisiología , Reoperación , Tendones/fisiopatología , Soporte de Peso/fisiología , Traumatismos de la Muñeca/fisiopatología , Articulación de la Muñeca/fisiopatología
5.
J Hand Surg Br ; 27(4): 307-16, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12162966

RESUMEN

Resection of the entire ulnar head (Darrach operation) and the hemiresection interposition arthroplasty are common methods of treating the arthritic distal radioulnar joint (DRUJ). Biomechnical investigation about both of these procedures is lacking. The purpose of this study was to evaluate the dynamic effects of both the hemiresection interposition arthroplasty and the Darrach procedure on radioulnar convergence and dorsal-palmar displacement and to compare their biomechanical behaviours. With a dynamic computer-controlled testing device, cadaveric forearm rotation was performed with simultaneous loading of relevant muscles. Torque along the forearm axis was generated by simulated muscle action through pneumoactuators attached to relevant tendons while the wrist was constrained to prescribed ranges of motion. The instability of the radius relative to the ulna was evaluated using displacement data of digitized landmarks in an ulnar coordinate system. Seven fresh-frozen cadaver upper extremities were used. The Darrach resection created an extreme instability of the forearm with movement of the radius ulnarly. Anteroposterior translations in each loading condition could also be detected, but the magnitude of displacement was small and less predictable. The results of the hemiresection interposition arthroplasty demonstrated significantly less instability compared with the Darrach results.


Asunto(s)
Artritis/fisiopatología , Artritis/cirugía , Artroplastia/efectos adversos , Inestabilidad de la Articulación/etiología , Radio (Anatomía)/fisiopatología , Radio (Anatomía)/cirugía , Articulación de la Muñeca/fisiopatología , Articulación de la Muñeca/cirugía , Anciano , Fenómenos Biomecánicos , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Torque , Soporte de Peso/fisiología
6.
J Bone Joint Surg Am ; 83(11): 1666-73, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11701789

RESUMEN

BACKGROUND: Second-generation cementless femoral components were designed to provide more reliable ingrowth and to limit distal osteolysis by incorporating circumferential proximal ingrowth surfaces. We examined the eight to eleven-year results of total hip arthroplasty with a cementless, anatomically designed femoral component and a cementless hemispheric acetabular component. METHODS: Ninety-two consecutive primary total hip arthroplasties with implantation of a femoral component with a circumferential proximal porous coating (Anatomic Hip) and a cementless hemispheric porous-coated acetabular component (Harris-Galante II) were performed in eighty-five patients. These patients were prospectively followed clinically and radiographically. Six patients (seven hips) died and five patients (seven hips) were lost to follow-up, leaving seventy-four patients (seventy-eight hips) who had been followed for a mean of ten years (range, eight to eleven years). The mean age at the time of the arthroplasty was fifty-two years. RESULTS: The mean preoperative Harris hip score of 51 points improved to 94 points at the time of final follow-up; 86% of the hips had a good or excellent result. Thigh pain was reported as mild to severe after seven hip arthroplasties. No femoral component was revised for any reason, and none were loose radiographically at the time of the last follow-up. Two hips underwent acetabular revision (one because of dislocation and one because of loosening). Kaplan-Meier survivorship analysis was performed with revision or loosening of any component as the end point. The ten-year survival rate was 96.4% +/- 2.1% for the total hip prosthesis, 100% for the femoral component, and 96.4% +/- 2.1% for the acetabular component. Radiolucencies adjacent to the nonporous portion of the femoral component were seen in sixty-eight (93%) of the -seventy-three hips with complete radiographic follow-up. Femoral osteolysis proximal to the lesser trochanter was noted in four hips (5%). No osteolysis was identified distal to the lesser trochanter. Periacetabular osteolysis was identified in twelve hips (16%). Five patients underwent exchange of the acetabular liner because of polyethylene wear. CONCLUSIONS: This second-generation cementless, anatomically designed femoral component provided excellent clinical and radiographic results with a 100% survival rate at ten years. The circumferential porous coating of this implant improved ingrowth and prevented distal osteolysis at a mean of ten years after the arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Acetábulo , Materiales Biocompatibles Revestidos , Fémur , Prótesis de Cadera , Humanos , Osteólisis/etiología , Osteólisis/prevención & control , Polietilenos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
7.
Orthop Clin North Am ; 32(4): 639-47, ix, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11689376

RESUMEN

Total knee arthroplasty has become the standard treatment for various disabling disorders of the knee and has proven long-term success. Surgical technique and prosthetic design have evolved to produce consistent and excellent results. Despite the current success of total knee arthroplasty, complications remain.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Inestabilidad de la Articulación/etiología , Fenómenos Biomecánicos , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/fisiopatología , Reoperación , Rotación , Tomografía Computarizada por Rayos X
8.
J Bone Joint Surg Br ; 83(7): 1023-8, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11603516

RESUMEN

We studied 57 patients with isolated lunotriquetral injuries treated by arthrodesis, direct ligament repair, or ligament reconstruction. The outcomes were compared by using written questionnaires, the Disabilities of the Arm, Shoulder and Hand (DASH) score, range of movement, strength, morbidity and rates of reoperation. Isolated lunotriquetral injury was confirmed by arthroscopy or arthrotomy. The mean age of the patients was 30.7 years (15.4 to 53.7) and the injuries were subacute or chronic in 98.2%. Eight patients underwent lunotriquetral reconstruction using a distally-based strip of the tendon of extensor carpi ulnaris, 27 had lunotriquetral repair and 22 had lunotriquetral arthrodesis. The mean follow-up was 9.5 years (2 to 22). The probability of remaining free from complications at five years was 68.6% for reconstruction, 13.5% for repair, and less than 1% for arthrodesis. Of the lunotriquetral arthrodeses, 40.9% developed nonunion and 22.7% developed ulnocarpal impaction. The probability of not requiring further surgery at five years was 68.6% for reconstruction, 23.3% for repair and 21.8% for arthrodesis. The DASH scores for each group were not significantly different. Objective improvements in strength and movement, subjective indicators of pain relief and satisfaction were significantly higher in the lunotriquetral repair and reconstruction groups than in those undergoing arthrodesis.


Asunto(s)
Artrodesis , Ligamentos Articulares/lesiones , Ligamentos Articulares/cirugía , Traumatismos de la Muñeca/cirugía , Adolescente , Adulto , Artrodesis/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Hueso Semilunar , Masculino , Persona de Mediana Edad , Procedimientos de Cirugía Plástica/efectos adversos , Procedimientos de Cirugía Plástica/métodos , Estudios Retrospectivos
9.
J Bone Joint Surg Am ; 83(8): 1231-6, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11507132

RESUMEN

BACKGROUND: Although initial reports on posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis have been encouraging, a high rate of late instability necessitating revision has been reported recently. The purpose of the present prospective study was to analyze the results of posterior cruciate ligament-retaining total knee arthroplasty in patients with rheumatoid arthritis. METHODS: Seventy-two posterior cruciate ligament-retaining total knee arthroplasties in fifty-one patients with rheumatoid arthritis were studied prospectively. All procedures were performed with the Miller-Galante I prosthesis. Eighteen patients (twenty-four knees) died before the eight-year follow-up and one patient (two knees) was lost to follow-up, leaving forty-six knees (thirty-two patients) for review. These forty-six knees were evaluated clinically (with particular attention to posterior instability) and radiographically at annual intervals for a mean of 10.5 years (range, eight to fourteen years). RESULTS: Forty-four (95%) of forty-six knees had a good or excellent result at a mean of 10.5 years. However, nine (13%) of the original seventy-two knees had revision of the implant, with six of the revisions performed because of failure of a metal-backed patellar component. The rate of survival at ten years was 93% 4% with femoral or tibial revision for any reason as the end point and 81% 5% with any reoperation as the end point. There was no aseptic loosening in any knee. Posterior instability was identified clinically and/or radiographically in two (2.8%) of the original seventy-two knees; both unstable knees were in the same patient. CONCLUSION: Posterior cruciate ligament-retaining total knee arthroplasty yielded satisfactory clinical and radiographic results in patients with rheumatoid arthritis at intermediate-term follow-up (mean, 10.5 years). Therefore, we believe that it remains an excellent treatment option for these patients.


Asunto(s)
Artritis Reumatoide/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Adulto , Anciano , Artritis Reumatoide/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Masculino , Persona de Mediana Edad , Ligamento Cruzado Posterior , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Resultado del Tratamiento
10.
Hand Clin ; 17(2): 151-68, vii, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11478038

RESUMEN

A detailed description of the ligamentous anatomy of the thumb basal joint is presented from a gross, arthroscopic, and functional point of view. All 16 ligaments that stabilize the trapezium and trapeziometacarpal (TM) joint are discussed in association with their presumed functional relevance regarding trapezial and trapeziometacarpal joint stability. Geometric and mathematical models are introduced to help describe and support anatomic observations with regard to ligament function. The dorsoradial ligament appears to be an important stabilizer of the TM joint against dorsally directed forces. The trapeziotrapezoid, trapezio-II metacarpal, and trapezio-III metacarpal ligaments appear to function as tension bands to help support the trapezium against cantilever bending forces imparted onto the trapezium by the thumb metacarpal.


Asunto(s)
Ligamentos Articulares/anatomía & histología , Pulgar/anatomía & histología , Artritis/patología , Artroscopía , Humanos , Inestabilidad de la Articulación/patología
11.
Clin Orthop Relat Res ; (388): 58-67, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11451133

RESUMEN

One hundred seventy-two consecutive cemented Miller-Galante-I total knee arthroplasties in 155 patients were compared with 109 consecutive cemented Miller-Galante-II total knee arthroplasties in 92 patients. The average followup was 11 years (range, 8-15 years) and 9 years (range, 8-10 years), respectively. Of the 172 Miller-Galante-I arthroplasties, there have been 21 revisions; 15 patellar revisions; two included femoral revisions attributable to abrasion. Six additional well-fixed femoral and tibial components were revised: two for early instability, one for pain, one for periprosthetic fracture, and two for infection. No component had aseptic loosening or osteolysis. Using revision or loosening of any components as the end point, the Kaplan-Meier 10-year survivorship was 84.1% +/- 4.1%. Of the 109 Miller-Galante-II arthroplasties, there have been no component revisions, no aseptic loosening, and no osteolysis. Using revision or loosening of any components as the end point, the Kaplan-Meier 10-year survivorship was 100%. The Miller-Galante knee systems showed excellent fixation with no loosening and no osteolysis at as many as 15 years. Additionally, there have been no component revisions for late instability at as many as 15 years. Finally, the high prevalence of patellofemoral complications with the Miller-Galante-I design has been obviated with the Miller-Galante-II design.


Asunto(s)
Prótesis de la Rodilla , Adulto , Anciano , Anciano de 80 o más Años , Artritis Reumatoide/cirugía , Artroplastia de Reemplazo de Rodilla , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Reoperación
12.
J Bone Joint Surg Am ; 83(6): 868-76, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11407795

RESUMEN

BACKGROUND: Total hip arthroplasty in patients with posttraumatic arthritis has produced results inferior to those in patients with nontraumatic arthritis. The use of cementless acetabular reconstruction, however, has not been extensively studied in this clinical context. Our purpose was to compare the intermediate-term results of total hip arthroplasty with a cementless acetabular component in patients with posttraumatic arthritis with those of the same procedure in patients with nontraumatic arthritis. We also compared the results of arthroplasty in patients who had had prior operative treatment of their acetabular fracture with those in patients who had had prior closed treatment of their acetabular fracture. METHODS: Thirty total hip arthroplasties were performed with use of a cementless hemispheric, fiber-metal-mesh-coated acetabular component for the treatment of posttraumatic osteoarthritis after acetabular fracture. The median interval between the fracture and the arthroplasty was thirty-seven months (range, eight to 444 months). The average age at the time of the arthroplasty was fifty-one years (range, twenty-six to eighty-six years), and the average duration of follow-up was sixty-three months (range, twenty-four to 140 months). Fifteen patients had had prior open reduction and internal fixation of their acetabular fracture (open-reduction group), and fifteen patients had had closed treatment of the acetabular fracture (closed-treatment group). The results of these thirty hip reconstructions were compared with the intermediate-term results of 204 consecutive primary total hip arthroplasties with cementless acetabular reconstruction in patients with nontraumatic arthritis. RESULTS: Operative time (p < 0.001), blood loss (p < 0.001), and perioperative transfusion requirements (p < 0.001) were greater in the patients with posttraumatic arthritis than they were in the patients with nontraumatic arthritis. Of the patients with posttraumatic arthritis, those who had had open reduction and internal fixation of their acetabular fracture had a significantly longer index procedure (p = 0.01), greater blood loss (p = 0.008), and a higher transfusion requirement (p = 0.049) than those in whom the fracture had been treated by closed methods. Eight of the fifteen patients with a previous open reduction and internal fixation required an elevated acetabular liner compared with one of the fifteen patients who had been treated by closed means (p = 0.005). Two of the fifteen patients with a previous open reduction and internal fixation required bone-grafting of acetabular defects compared with seven of the fifteen patients treated by closed means (p = 0.04). The thirty patients treated for posttraumatic arthritis had an average preoperative Harris hip score of 41 points, which increased to 88 points at the time of follow-up; there was no significant difference between the open-reduction and closed-treatment groups (p = 0.39). Twenty-seven patients (90%) had a good or excellent result. There were no dislocations or deep infections. The Kaplan-Meier ten-year survival rate, with revision or radiographic loosening as the end point, was 97%. These results were similar to those of the patients who underwent primary total hip arthroplasty for nontraumatic arthritis. CONCLUSIONS: The intermediate-term clinical results of total hip arthroplasty with cementless acetabular reconstruction for posttraumatic osteoarthritis after acetabular fracture were similar to those after the same procedure for nontraumatic arthritis, regardless of whether the acetabular fracture had been internally fixed initially. However, total hip arthroplasty after acetabular fracture was a longer procedure with greater blood loss, especially in patients with previous open reduction and internal fixation. Previous open reduction and internal fixation predisposed the hip to more intraoperative instability but less bone deficiency.


Asunto(s)
Acetábulo/lesiones , Acetábulo/cirugía , Artritis/cirugía , Artroplastia de Reemplazo de Cadera , Fracturas Óseas/complicaciones , Articulación de la Cadera , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artritis/etiología , Artroplastia de Reemplazo de Cadera/instrumentación , Cementación , Femenino , Estudios de Seguimiento , Fracturas Óseas/terapia , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osificación Heterotópica/etiología , Complicaciones Posoperatorias , Falla de Prótesis , Radiografía , Reoperación
13.
J Biomech ; 34(3): 335-9, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11182124

RESUMEN

In order to perform cadaveric biomechanical studies of the human forearm and distal radio-ulnar joint, a dynamic simulator has been constructed. The device is based upon a Plexiglas frame, to which the ulna is secured in a vertical orientation and the humerus in a horizontal orientation. The hand is secured in a sliding bar linkage to a stepper-motor that is used to rotate the forearm. The tendons to be loaded are connected to pneumatic actuators that provide agonist and antagonist muscle loading resulting in torque along the forearm axis. The muscle loading profiles and magnitudes are programmable as a function of the pronation-supination position and direction. A magnetic tracking system is used to collect three-dimensional kinematics data of up to four segments, in conjunction with the muscle tendon loads, forearm torque and other prescribed experimental measures. All functions are under PC control using custom software written with LabVIEW (National Instruments, Austin, TX). For the DRUJ testing, the validity of the tendon loading protocol to produce physiologic torque/rotation patterns was verified using in vivo data. The relationship of individual muscle forces to forearm torque was determined by a cadaveric study.


Asunto(s)
Articulación de la Muñeca/fisiología , Fenómenos Biomecánicos , Cadáver , Simulación por Computador , Antebrazo/fisiología , Humanos , Magnetismo , Movimiento , Radio (Anatomía)/fisiología , Torque , Cúbito/fisiología , Soporte de Peso
14.
J Bone Joint Surg Am ; 83(1): 86-91, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11205863

RESUMEN

BACKGROUND: Intraoperative disruption of the medial collateral ligament during total knee arthroplasty is an uncommon complication that is frequently treated by implanting a prosthesis with varus-valgus constraint. To our knowledge, no data have been published on primary repair or reattachment of the medial collateral ligament and implantation of a minimally constrained posterior-stabilized or cruciate-retaining prosthesis. This retrospective study evaluates the hypothesis that satisfactory clinical results, at a minimum of two years, can be achieved with immediate repair or reattachment of the medial collateral ligament and without a constrained total knee prosthesis. METHODS: Of 600 knees treated with primary total knee arthroplasty, sixteen (in fourteen patients) sustained either a midsubstance disruption of the medial collateral ligament or an avulsion of the ligament from bone during the procedure. Preoperatively, all patients had either neutral or varus alignment and an intact medial collateral ligament. Midsubstance tears were treated with direct primary repair, and avulsions of the ligament off the tibia or femur were treated with suture-anchor reattachment to bone. All patients wore a hinged knee brace, with no limit to the range of motion, for six weeks postoperatively. Clinical and radiographic data were gathered prospectively as part of a database that was ongoing throughout the period of study; the cohort of patients was assembled retrospectively by searching that database. RESULTS: No patients were lost to follow-up. The mean duration of follow-up was forty-five months (range, twenty-four to ninety-five months). The Hospital for Special Surgery knee scores increased from a mean of 47 points (poor) preoperatively to a mean of 93 points (excellent) at the time of final follow-up. On physical examination, no patient had a Hospital for Special Surgery score in the fair or poor range and all patients had regained normal stability in the coronal plane both at full extension and at 30 degrees of flexion. No patient required knee-bracing beyond the initial six-week postoperative period. The range of motion at the time of final follow-up averaged 108 degrees (range, 85 degrees to 125 degrees ), although one knee required manipulation under anesthesia to obtain a satisfactory range of motion. No arthroplasties required revision. Radiographic examination demonstrated appropriate limb alignment in all patients at the time of final follow-up. CONCLUSIONS: Intraoperative disruption of the medial collateral ligament can be treated with primary repair or reattachment of the ligament to bone and postoperative bracing with good results; this avoids the potential disadvantages associated with the use of varus-valgus constrained implants.


Asunto(s)
Artroplastia de Reemplazo , Complicaciones Intraoperatorias/cirugía , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Ligamento Colateral Medial de la Rodilla/lesiones , Ligamento Colateral Medial de la Rodilla/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos
15.
J Hand Surg Br ; 25(6): 544-7, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11106515

RESUMEN

A retrospective review of 66 T-shaped incisions for exposure of the dorsal distal radius and wrist was performed. The incision provided excellent exposure in all cases and no additional incisions were required. Cosmesis was considered acceptable by all patients. Complications occurred in 6% and were more likely in patients undergoing fixation of acute distal radius fractures using Kirschner wires which protruded through the skin flaps.


Asunto(s)
Procedimientos Quirúrgicos Dermatologicos , Articulación de la Muñeca/cirugía , Adolescente , Adulto , Huesos del Carpo/cirugía , Femenino , Fijación Interna de Fracturas , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/métodos , Fracturas del Radio/cirugía , Cicatrización de Heridas
16.
J Arthroplasty ; 15(7): 938-43, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11061457

RESUMEN

A case is presented in which an elevated serum titanium level was used to make the diagnosis of a failed metal-backed patellar component. The preoperative serum titanium level was 536.8 ppb, which was 98 times higher than the patient's previous level (taken 1 year earlier, when he was asymptomatic) and 2 orders of magnitude higher than the expected level with a well-functioning implant of this type. Revision surgery confirmed that the polyethylene portion of the patellar component had worn through, leaving the titanium portion of the patellar implant to articulate with the femoral component. Wear-through was not evident on preoperative radiographs or clinical examination. As knowledge about the expected ranges for serum metal ion levels after total joint arthroplasty continues to increase, the diagnostic utility of serum metal ion testing in the evaluation of joint arthroplasty function will continue to improve.


Asunto(s)
Prótesis de la Rodilla , Falla de Prótesis , Titanio/sangre , Anciano , Artroplastia de Reemplazo de Rodilla , Humanos , Masculino , Rótula , Reoperación
17.
J Bone Joint Surg Am ; 82(9): 1291-9, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11005520

RESUMEN

BACKGROUND: Use of modern cementing techniques for fixation of femoral components in total hip arthroplasty has had excellent clinical and radiographic results in most patients. However, several authors have described early loosening of femoral components with roughened and precoated finishes. The purpose of this study was to examine the performance of the precoated Iowa stem, which has increased offset, and to compare the results with those of another cemented precoated femoral component with standard offset used at our institution. METHODS: We carried out a prospective analysis of 102 primary hybrid total hip arthroplasties (a cementless acetabular component and a cemented femoral component) performed with use of the Iowa femoral component in ninety-five patients at our institution. The Iowa stem was used in hips that required greater offset than is available with standard stems as determined by preoperative templating. The average age of the patients at the time of the index procedure was sixty-nine years. Sixteen patients (seventeen hips) died before the forty-eight-month minimum follow-up period had elapsed. Two patients were lost to follow-up, and radiographic follow-up was incomplete for one. The mean duration of clinical and radiographic follow-up of the remaining eighty-two hips in the seventy-six surviving patients was sixty-five months (range, forty-eight to 104 months). RESULTS: The average preoperative Harris hip score of 47 points (range, 16 to 69 points) improved to an average of 87 points (range, 24 to 100 points) at the time of the review. Two hips underwent femoral component revision. Four femoral stems were radiographically loose at an average of thirty-four months. Femoral osteolysis was seen in five hips (6 percent) at an average of fifty-four months postoperatively. No acetabular component was revised because of aseptic loosening. According to Kaplan-Meier analysis, the seven-year survival rate, with an end point of femoral revision, osteolysis, or stem debonding, was 90.6 percent (95 percent confidence interval, 0.87 to 0.94). CONCLUSIONS: The prevalence of revision, osteolysis, and loosening after total hip arthroplasty with the Iowa femoral component at our institution was higher than that seen in our series of Harris Precoat stems, which had a survival rate of 98.4 percent (95 percent confidence interval, 0.97 to 1.00) at ten years with the same end points. The design of the Iowa stem may make it difficult to achieve a good cement mantle, and, in combination with the geometry and increased offset of the stem, may compromise the long-term survival of this cemented femoral component.


Asunto(s)
Cementos para Huesos , Materiales Biocompatibles Revestidos , Prótesis de Cadera , Acetábulo , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Radiografía
18.
J Hand Surg Am ; 25(4): 689-99, 2000 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10913210

RESUMEN

Sixteen fresh-frozen adult human cadaveric upper extremities were used in a biomechanical analysis of distal radioulnar joint (DRUJ) stability. The relative contribution to stability of the DRUJ by the surrounding anatomic structures presumed to stabilize the joint was analyzed with respect to forearm rotation and wrist flexion and extension using a purpose-built 4-axis materials testing machine. The dominant structures stabilizing the DRUJ were the ligamentous components of the triangular fibrocartilage complex proper. The major constraint to dorsal translation of the distal ulna relative to the radius is the palmar radioulnar ligament. Palmar translation of the distal ulna relative to the radius is constrained primarily by the dorsal radioulnar ligament, with secondary constraint provided by the palmar radioulnar ligament and interosseous membrane. The ulnocarpal ligaments and extensor carpi ulnaris subsheath did not contribute significantly to DRUJ stability; however, approximately 20% of DRUJ constraint is provided by the articular contact of the radius and ulna. These relationships were consistent regardless of wrist position or degree of forearm rotation.


Asunto(s)
Ligamentos/fisiología , Articulación de la Muñeca/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Humanos , Ligamentos/anatomía & histología , Persona de Mediana Edad , Pronación/fisiología , Radio (Anatomía)/anatomía & histología , Radio (Anatomía)/fisiología , Supinación/fisiología , Cúbito/anatomía & histología , Cúbito/fisiología , Articulación de la Muñeca/anatomía & histología
19.
Handchir Mikrochir Plast Chir ; 32(6): 411-8, 2000 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-11189895

RESUMEN

Pain, weakness, malalignment and limited range of motion (ROM) at the PIP joint following arthrosis (degenerative or post-traumatic) or rheumatoid arthritis frequently require surgical treatment. PIP joint fusion or implantation of a prosthetic device are options. The purpose of this study was to report our long-term results with a surface replacement PIP arthroplasty (SR PIP arthroplasty) and the description of our operative technique. 82 prostheses were done in 60 patients between 1980 and 1999. All patients were reexamined, the average follow up was 64 months (12 to 260 months); average age was 57 years. 48 patients were operated on the right hand, 12 on the left hand. 44 patients were female, 16 were male. All patients complained of pain preoperatively. Patients were divided into three groups: A degenerative arthrosis, B posttraumatic arthrosis and C inflammatory arthritis. Active range of motion of all fingers of the operated hand, grip-strength, pain relief, joint stability or deformity and comprehensive radiographic assessment were studied. The subjective impressions of the patients were measured in four grades: very satisfied--satisfied--dissatisfied--very dissatisfied. Finally the investigators divided the overall results in: good--fair--poor. The average flexion arc was 31 degrees (maximum 15 degrees hyperextension to 95 degrees flexion) preoperatively and 47 degrees (maximum 14 degrees hyperextension to 90 degrees flexion) postoperatively. Over 70% of the patients had complete pain relief. In 12 fingers secondary procedures were necessary, usually related to soft tissue deformity and extensor tendon function. No arthrodesis was performed as a following operation. In 40 fingers a good result was achieved (49%), 25 had a fair (30%) and 17 (21%) a poor result. Our results of resurfacing PIP arthroplasty are encouraging and provide equal and usually improved motion in comparison with other joints. With experience and refinements of the operative technique our confidence in surface replacement arthroplasty has increased. For this reason we prefer this procedure for posttraumatic or degenerative arthrosis as against PIP joint fusion or silastic implants.


Asunto(s)
Articulaciones de los Dedos/cirugía , Prótesis Articulares , Osteoartritis/cirugía , Anciano , Femenino , Articulaciones de los Dedos/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Diseño de Prótesis , Radiografía , Reoperación
20.
J Bone Joint Surg Am ; 81(12): 1682-91, 1999 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-10608379

RESUMEN

BACKGROUND: The decision as to whether to revise or retain a well fixed cemented acetabular component during revision of a femoral component is especially difficult; the rate of loosening of cemented acetabular components is high, whereas that of porous-coated acetabular components inserted during revision is low. However, removal of a well fixed cemented acetabular component can result in increased operative morbidity and cost and in loss of acetabular bone. Data that can be used to predict the long-term survival of retained well fixed cemented acetabular components are therefore needed. METHODS: We studied the five to thirteen-year clinical and radiographic results in a group of twenty-six consecutive patients in whom a well fixed cemented acetabular component had been retained during revision of a femoral component. Typical demographic data on the patients and information about the components were recorded, and the cemented acetabular components were graded as A through F, according to the system of Ranawat et al., at the time of the femoral revision. The average duration of follow-up was 8.4 years (range, 5.0 to 12.7 years). No patient was lost to follow-up. RESULTS: Four acetabular components (15 percent) had progressive radiolucency (at forty-eight, forty-eight, fifty-nine, and seventy-five months after the femoral revision) and were considered radiographically loose despite not being associated with symptoms. All four components were graded as either E or F at the time that they were retained during the femoral revision; radiographic loosening was significantly related to these two grades (p < 0.01). No acetabular component with a grade of A, B, C, or D loosened. The components that loosened had been in vivo for a relatively shorter, as opposed to longer, duration before the femoral revision compared with the components that did not loosen (p < 0.05). CONCLUSIONS: Retention of the well fixed cemented acetabular components was associated with good clinical results but with a 15 percent rate of loosening. Revision of a cemented acetabular component solely on the basis of the duration that it was in vivo or whether a previous revision had been done does not appear to be warranted. Our findings suggest that acetabular components with a grade of A, B, C, or D at the time of a femoral revision may be retained, as these components continued to function at the time of the five to thirteen-year follow-up in the current study.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Materiales Biocompatibles Revestidos , Fémur/cirugía , Osteólisis/cirugía , Falla de Prótesis , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Fémur/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/diagnóstico por imagen , Radiografía , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA