Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
PLoS One ; 11(12): e0168244, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27992495

RESUMEN

BACKGROUND: Expansion of HIV viral load (VL) testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid) was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert's random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites). Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS) and whole blood, was investigated. METHOD: Precision, accuracy (agreement) and clinical misclassification (1000cp/ml) of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155) and Abbott HIV-1 RT (n = 145). Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145) and whole blood (n = 147). RESULTS: Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42) and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32-0.37logcp/ml) and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh) and Abbott HIV-1 RT (frozen), respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward) by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument. CONCLUSION: The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services.


Asunto(s)
Infecciones por VIH/diagnóstico , Tamizaje Masivo/métodos , Técnicas de Diagnóstico Molecular/métodos , ARN Viral/sangre , Carga Viral/métodos , Adulto , Terapia Antirretroviral Altamente Activa , Femenino , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/epidemiología , VIH-1 , Humanos , Masculino , Persona de Mediana Edad , ARN Viral/análisis , Sensibilidad y Especificidad , Sudáfrica/epidemiología , Manejo de Especímenes/métodos
2.
J Clin Microbiol ; 52(6): 1818-23, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24622091

RESUMEN

South Africa implemented Xpert MTB/RIF as the initial diagnostic test for pulmonary tuberculosis (TB). Xpert MTB/RIF's accuracy for diagnosing extrapulmonary tuberculosis (EPTB) was investigated. EPTB specimens (n = 7,916) from hospitalized patients received over a 6-month period at a high-throughput TB referral laboratory in Johannesburg were investigated. Large-volume specimens were centrifuged, tissue biopsy specimens homogenized, and all specimens checked for growth of contaminating bacteria on blood agar. Contaminated samples received NALC-NaOH (N-acetyl-l-cysteine-sodium hydroxide) decontamination prior to liquid culture. Residual specimens (volumes > 1 ml) after inoculation of culture (n = 1,175) were tested using the Xpert MTB/RIF sputum protocol. Using culture as the reference, Xpert MTB/RIF's overall sensitivity was 59% (95% confidence interval [95% CI], 53% to 65%) and specificity was 92% (CI, 90% to 94%), with the highest sensitivities of 91% (95% CI, 78% to 97%) for pus, 80% (95% CI, 56% to 94%) for lymph node aspirates, and 51% (95% CI, 44% to 58%) for fluids (ascitic, 59%; pleural, 47%). A difference in sensitivities was noticed between specimens classified as having a thick (87% [95% CI, 76% to 94%]) versus clear (watery) (48% [95% CI, 36% to 61%]) appearance. This was unchanged with traces of blood (52% [95% CI, 44% to 60%]) or precentrifugation (57% [95% CI, 28% to 82%]) among clear specimens. Xpert MTB/RIF generated an additional 124 specimen results that were contaminated by Mycobacterial Growth Indicator Tubes (MGIT; 10.5%) and diagnosed rifampin (RIF) resistance earlier (9.6% [25/260]). Xpert MTB/RIF's performance on EPTB specimens provides very promising results and should be considered for incorporation into national TB guidelines. Xpert MTB/RIF is less affected by contaminating bacteria and reduces laboratory labor and diagnostic delay compared to traditional methods.


Asunto(s)
Algoritmos , Técnicas Bacteriológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Tuberculosis/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antituberculosos/farmacología , Líquidos Corporales/microbiología , Niño , Preescolar , Farmacorresistencia Bacteriana , Femenino , Humanos , Lactante , Recién Nacido , Ganglios Linfáticos/microbiología , Masculino , Persona de Mediana Edad , Rifampin/farmacología , Sensibilidad y Especificidad , Sudáfrica , Adulto Joven
3.
Viruses ; 4(9): 1753-91, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23170182

RESUMEN

The family Geminiviridae comprises a group of plant-infecting circular ssDNA viruses that severely constrain agricultural production throughout the temperate regions of the world, and are a particularly serious threat to food security in sub-Saharan Africa. While geminiviruses exhibit considerable diversity in terms of their nucleotide sequences, genome structures, host ranges and insect vectors, the best characterised and economically most important of these viruses are those in the genus Begomovirus. Whereas begomoviruses are generally considered to be either monopartite (one ssDNA component) or bipartite (two circular ssDNA components called DNA-A and DNA-B), many apparently monopartite begomoviruses are associated with additional subviral ssDNA satellite components, called alpha- (DNA-αs) or betasatellites (DNA-ßs). Additionally, subgenomic molecules, also known as defective interfering (DIs) DNAs that are usually derived from the parent helper virus through deletions of parts of its genome, are also associated with bipartite and monopartite begomoviruses. The past three decades have witnessed the emergence and diversification of various new begomoviral species and associated DI DNAs, in southern Africa, East Africa, and proximal Indian Ocean islands, which today threaten important vegetable and commercial crops such as, tobacco, cassava, tomato, sweet potato, and beans. This review aims to describe what is known about these viruses and their impacts on sustainable production in this sensitive region of the world.


Asunto(s)
Begomovirus/clasificación , Begomovirus/genética , ADN Viral/genética , Helechos/virología , Variación Genética , Enfermedades de las Plantas/virología , África Oriental , África Austral , Begomovirus/aislamiento & purificación , Islas del Oceano Índico
4.
J Clin Microbiol ; 50(7): 2373-7, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22518871

RESUMEN

Early initiation of antiretroviral therapy reduces HIV-related infant mortality. The early peak of pediatric HIV-related deaths in South Africa occurs at 3 months of age, coinciding with the earliest age at which treatment is initiated following PCR testing at 6 weeks of age. Earlier diagnosis is necessary to reduce infant mortality. The performances of the Amplicor DNA PCR, COBAS AmpliPrep/COBAS TaqMan (CAP/CTM), and Aptima assays for detecting early HIV infection (acquired in utero and intrapartum) up to 6 weeks of age were compared. Dried blood spots (DBS) were collected at birth and at 2, 4, and 6 weeks from HIV-exposed infants enrolled in an observational cohort study in Johannesburg, South Africa. HIV status was determined at 6 weeks by DNA PCR on whole blood. Serial DBS samples from all HIV-infected infants and two HIV-uninfected, age-matched controls were tested with the 3 assays. Of 710 infants of known HIV status, 38 (5.4%) had in utero (n = 29) or intrapartum (n = 9) infections. By 14 weeks, when treatment should have been initiated, 13 (45%) in utero-infected and 2 (22%) intrapartum-infected infants had died or were lost to follow-up. The CAP/CTM and Aptima assays identified 76.3% of all infants with early HIV infections at birth and by 4 weeks were 96% sensitive. DNA PCR demonstrated lower sensitivities at birth and 4 weeks of 68.4% and 87.5%, respectively. All assays had the lowest sensitivity at 2 weeks of age. CAP/CTM was the only assay with 100% specificity at all ages. Testing at birth versus 6 weeks of age identifies a higher total number of HIV-infected infants, irrespective of the assay.


Asunto(s)
Enfermedades Fetales/diagnóstico , Infecciones por VIH/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Virología/métodos , Adulto , Sangre/virología , Estudios de Cohortes , Diagnóstico Precoz , Femenino , VIH/aislamiento & purificación , Humanos , Lactante , Recién Nacido , Estudios Prospectivos , Sensibilidad y Especificidad , Sudáfrica , Adulto Joven
5.
J Clin Microbiol ; 47(8): 2465-9, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19474266

RESUMEN

The early diagnosis of human immunodeficiency virus (HIV) infection in infants is critical to ensure the initiation of treatment before significant immunological compromise. Each year an estimated 300,000 HIV-exposed infants in South Africa require access to tests for the diagnosis of HIV infection. Currently, testing is performed at several facilities by using PCR amplification of HIV DNA at 6 weeks of age by the use of dried blood spots (DBSs) and whole blood (WB). The Gen-Probe Aptima HIV type 1 (HIV-1) screening assay (the Aptima assay) is a qualitative nucleic acid test based on transcription-mediated amplification (TMA), a technology routinely used in blood banks in South Africa. The performance characteristics of Gen-Probe's TMA technology compared well to those of the Roche Amplicor HIV-1 DNA (version 1.5) assay. The sensitivity of the assay with WB and DBS samples was 100%, and the specificities were 99.4% and 99.5% for DBSs and WB, respectively. The detection of HIV by the Aptima assay at greater levels of dilution in samples negative by the comparator assay indicates an improvement in sensitivity by the use of the TMA technology. The ability to process 1,900 samples in a 24-h period on the Tigris instrument makes the Aptima assay an attractive option for high-volume, centralized laboratories.


Asunto(s)
Automatización , Infecciones por VIH/diagnóstico , VIH-1/aislamiento & purificación , Tamizaje Masivo/métodos , Técnicas de Diagnóstico Molecular/métodos , ARN Viral/genética , Virología/métodos , Sangre/virología , Infecciones por VIH/virología , VIH-1/genética , Humanos , Lactante , Sensibilidad y Especificidad , Sudáfrica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA