Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Radiother Oncol ; 198: 110414, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38942120

RESUMEN

BACKGROUND AND PURPOSE: As no guidelines for pencil beam scanning (PBS) proton therapy (PT) of paediatric posterior fossa (PF) tumours exist to date, this study investigated planning techniques across European PT centres, with special considerations for brainstem and spinal cord sparing. MATERIALS AND METHODS: A survey and a treatment planning comparison were initiated across nineteen European PBS-PT centres treating paediatric patients. The survey assessed all aspects of the treatment chain, including but not limited to delineations, dose constraints and treatment planning. Each centre planned two PF tumour cases for focal irradiation, according to their own clinical practice but based on common delineations. The prescription dose was 54 Gy(RBE) for Case 1 and 59.4 Gy(RBE) for Case 2. For both cases, planning strategies and relevant dose metrics were compared. RESULTS: Seventeen (89 %) centres answered the survey, and sixteen (80 %) participated in the treatment planning comparison. In the survey, thirteen (68 %) centres reported using the European Particle Therapy Network definition for brainstem delineation. In the treatment planning study, while most centres used three beam directions, their configurations varied widely across centres. Large variations were also seen in brainstem doses, with a brainstem near maximum dose (D2%) ranging from 52.7 Gy(RBE) to 55.7 Gy(RBE) (Case 1), and from 56.8 Gy(RBE) to 60.9 Gy(RBE) (Case 2). CONCLUSION: This study assessed the European PBS-PT planning of paediatric PF tumours. Agreement was achieved in e.g. delineation-practice, while wider variations were observed in planning approach and consequently dose to organs at risk. Collaboration between centres is still ongoing, striving towards common guidelines.

3.
Phys Med Biol ; 68(17)2023 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-37506707

RESUMEN

Objective.The treatment of mobile tumours using Pencil Beam Scanning (PBS) has become more prevalent in the last decade. However, to achieve the same beam delivery quality as for static tumours, treatments have to be combined with motion mitigation techniques, not limited but including, breath hold, gating and re-scanning, which typically prolong treatment time. In this article we present a novel method of bi-directional energy modulation and demonstrate our initial experience in improvement of treatment efficiency. Approach.At Paul Scherrer Institute Gantry 2 mobile tumours are treated by combining PBS with gating and volumetric re-scanning (VR), where the target volume is irradiated multiple times. Initial implementation of VR used only descending beam energies, creating a substantial dead time due to the beam-line initialization (ramping) before each re-scan. In 2019 we commissioned an energy meandering strategy that allows us to avoid beam line ramping in-between energy series while maintaining beam delivery quality.Main results.The measured beam parameters difference for both energy sequence are in the order of the typical daily variations: 0.2 mm in beam position and 0.2 mm in range. Using machine log files, we performed point-to-point dose difference calculations between original and new applications where we observed dose differences of less than 2%. After three years of operation employing bi-directional energy modulation, we have analysed the individual beam delivery time for 181 patients and have compared this to simulations of the timing behaviour assuming uni-directional energy sequence application. Depending on treatment complexity, we obtained plan delivery time reductions of up to 55%, with a median time gain of 17% for all types of treatments.Significance. Bi-directional energy modulation can help improving patient treatment efficiency by reducing delivery times especially for complex and specialised irradiations. It could be implemented in many existing facilities without significant additional hardware upgrades.


Asunto(s)
Neoplasias , Terapia de Protones , Humanos , Terapia de Protones/métodos , Neoplasias/radioterapia , Movimiento (Física) , Contencion de la Respiración , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica
4.
Cancers (Basel) ; 15(12)2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37370709

RESUMEN

The aim of this study was to assess the clinical outcome, including QoL, of patients with intracranial meningiomas WHO grade 1-3 who were treated with Pencil Beam Scanning Proton Therapy (PBS PT) between 1997 and 2022. Two hundred patients (median age 50.4 years, 70% WHO grade 1) were analyzed. Acute and late side effects were classified according to CTCAE version 5.0. Time to event data were calculated. QoL was assessed descriptively by the EORTC-QLQ-C30 and BN20 questionnaires. With a median follow-up of 65 months (range: 3.8-260.8 months) the 5 year OS was 95.7% and 81.8% for WHO grade 1 and grade 2/3, respectively (p < 0.001). Twenty (10%) local failures were observed. Failures occurred significantly (p < 0.001) more frequent in WHO grade 2 or 3 meningioma (WHO grade 1: n = 7, WHO grade 2/3: n = 13), in patients with multiple meningiomas (p = 0.005), in male patients (p = 0.005), and when PT was initiated not as upfront therapy (p = 0.011). There were no high-grade toxicities in the majority (n = 176; 88%) of patients. QoL was assessed for 83 (41.5%) patients and for those patients PT did not impacted QoL negatively during the follow-up. In summary, we observed very few local recurrences of meningiomas after PBS PT, a stable QoL, and a low rate of high-grade toxicity.

5.
Phys Imaging Radiat Oncol ; 26: 100442, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37197154

RESUMEN

Background and purpose: Anatomical changes may compromise the planned target coverage and organs-at-risk dose in particle therapy. This study reports on the practice patterns for adaptive particle therapy (APT) to evaluate current clinical practice and wishes and barriers to further implementation. Materials and methods: An institutional questionnaire was distributed to PT centres worldwide (7/2020-6/2021) asking which type of APT was used, details of the workflow, and what the wishes and barriers to implementation were. Seventy centres from 17 countries participated. A three-round Delphi consensus analysis (10/2022) among the authors followed to define recommendations on required actions and future vision. Results: Out of the 68 clinically operational centres, 84% were users of APT for at least one treatment site with head and neck being most common. APT was mostly performed offline with only two online APT users (plan-library). No centre used online daily re-planning. Daily 3D imaging was used for APT by 19% of users. Sixty-eight percent of users had plans to increase their use or change their technique for APT. The main barrier was "lack of integrated and efficient workflows". Automation and speed, reliable dose deformation for dose accumulation and higher quality of in-room volumetric imaging were identified as the most urgent task for clinical implementation of online daily APT. Conclusion: Offline APT was implemented by the majority of PT centres. Joint efforts between industry research and clinics are needed to translate innovations into efficient and clinically feasible workflows for broad-scale implementation of online APT.

6.
Radiother Oncol ; 184: 109675, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37084884

RESUMEN

BACKGROUND AND PURPOSE: Studies have shown large variations in stopping-power ratio (SPR) prediction from computed tomography (CT) across European proton centres. To standardise this process, a step-by-step guide on specifying a Hounsfield look-up table (HLUT) is presented here. MATERIALS AND METHODS: The HLUT specification process is divided into six steps: Phantom setup, CT acquisition, CT number extraction, SPR determination, HLUT specification, and HLUT validation. Appropriate CT phantoms have a head- and body-sized part, with tissue-equivalent inserts in regard to X-ray and proton interactions. CT numbers are extracted from a region-of-interest covering the inner 70% of each insert in-plane and several axial CT slices in scan direction. For optimal HLUT specification, the SPR of phantom inserts is measured in a proton beam and the SPR of tabulated human tissues is computed stoichiometrically at 100 MeV. Including both phantom inserts and tabulated human tissues increases HLUT stability. Piecewise linear regressions are performed between CT numbers and SPRs for four tissue groups (lung, adipose, soft tissue, and bone) and then connected with straight lines. Finally, a thorough but simple validation is performed. RESULTS: The best practices and individual challenges are explained comprehensively for each step. A well-defined strategy for specifying the connection points between the individual line segments of the HLUT is presented. The guide was tested exemplarily on three CT scanners from different vendors, proving its feasibility. CONCLUSION: The presented step-by-step guide for CT-based HLUT specification with recommendations and examples can contribute to reduce inter-centre variations in SPR prediction.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Protones , Consenso , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Calibración
7.
Pediatr Blood Cancer ; 70(2): e30087, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36377685

RESUMEN

Central nervous system (CNS) tumors are the most common solid malignancies in children and adolescents and young adults (C-AYAs). Craniospinal irradiation (CSI) is an essential treatment component for some malignancies, but it can also lead to important toxicity. Pencil beam scanning proton therapy (PBSPT) allows for a minimization of dose delivered to organs at risk and, thus, potentially reduced acute and late toxicity. This study aims to report the clinical outcomes and toxicity rates after CSI for C-AYAs treated with PBSPT. Seventy-one C-AYAs (median age: 7.4 years) with CNS tumors were treated with CSI between 2004 and 2021. Medulloblastoma (n = 42: 59%) and ependymoma (n = 8; 11%) were the most common histologies. Median prescribed total PBSPT dose was 54 GyRBE (range: 18-60.4), and median prescribed craniospinal dose was 24 GyRBE (range: 18-36.8). Acute and late toxicities were coded according to Common Terminology Criteria for Adverse Events. After a median follow-up of 24.5 months, the estimated 2-year local control, distant control, and overall survival were 86.3%, 80.5%, and 84.7%, respectively. Late grade ≥3 toxicity-free rate was 92.6% at 2 years. Recurrent and metastatic tumors were associated with worse outcome. In conclusion, excellent tumor control with low toxicity rates was observed in C-AYAs with brain tumors treated with CSI using PBSPT.


Asunto(s)
Neoplasias Encefálicas , Neoplasias del Sistema Nervioso Central , Neoplasias Cerebelosas , Irradiación Craneoespinal , Terapia de Protones , Humanos , Niño , Adolescente , Adulto Joven , Terapia de Protones/efectos adversos , Irradiación Craneoespinal/efectos adversos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/etiología , Neoplasias Cerebelosas/radioterapia , Dosificación Radioterapéutica
8.
In Vivo ; 36(2): 678-686, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35241522

RESUMEN

BACKGROUND/AIM: The effective atomic number (Zeff) and electron density relative to water (ρe or Rho) of elements can be derived in dual-energy computed tomography (DECT). The aim of this phantom study was to investigate the effect of different photon energies, radiation doses, and reconstruction kernels on Zeff and Rho measured in DECT. MATERIALS AND METHODS: An anthropomorphic head phantom including five probes of known composition was scanned under three tube-voltage combinations in DECT: Sn140/100 kV, 140/80 kV and Sn140/80 kV with incremented radiation doses. Raw data were reconstructed with four reconstruction kernels (I30, I40, I50, and I70). Rho and Zeff were measured for each probe for all possible combinations of scan and reconstruction parameters. RESULTS: DECT-based Rho and Zeff closely approached the reference values with a mean and maximum error of 1.7% and 6.8%, respectively. Rho was lower for 140/80 kV compared with Sn140/100 kV and Sn140/80 kV with differences being 0.009. Zeff differed among all tube voltages with the most prominent difference being 0.28 between 140/80 kV and Sn140/100 kV. Zeff was lower in I70 compared with those of I30 and I40 with a difference of 0.07. Varying radiation dose yielded a variation of 0.0002 in Rho and 0.03 in Z, both considered negligible in practice. CONCLUSION: DECT comprises a feasible method for the extraction of material-specific information. Slight variations should be taken into account when different radiation doses, photon energies, and kernels are applied; however, they are considered small and in practice not crucial for an effective tissue differentiation.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Computadores , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
9.
Z Med Phys ; 32(1): 52-62, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32830006

RESUMEN

We present the commissioning and quality assurance of our clinical protocol for respiratory gating in pencil beam scanning proton therapy for cancer patients with moving targets. In a novel approach, optical tracking has been integrated in the therapy workflow and used to monitor respiratory motion from multiple surrogates, applied on the patients' chest. The gating system was tested under a variety of experimental conditions, specific to proton therapy, to evaluate reaction time and reproducibility of dose delivery control. The system proved to be precise in the application of beam gating and allowed the mitigation of dose distortions even for large (1.4cm) motion amplitudes, provided that adequate treatment windows were selected. The total delivered dose was not affected by the use of gating, with measured integral error within 0.15cGy. Analysing high-resolution images of proton transmission, we observed negligible discrepancies in the geometric location of the dose as a function of the treatment window, with gamma pass rate greater than 95% (2%/2mm) compared to stationary conditions. Similarly, pass rate for the latter metric at the 3%/3mm level was observed above 97% for clinical treatment fields, limiting residual movement to 3mm at end-exhale. These results were confirmed in realistic clinical conditions using an anthropomorphic breathing phantom, reporting a similarly high 3%/3mm pass rate, above 98% and 94%, for regular and irregular breathing, respectively. Finally, early results from periodic QA tests of the optical tracker have shown a reliable system, with small variance observed in static and dynamic measurements.


Asunto(s)
Terapia de Protones , Humanos , Fantasmas de Imagen , Terapia de Protones/métodos , Protones , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Respiración
10.
Sci Rep ; 11(1): 6085, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33727599

RESUMEN

We report on a comparative dosimetrical study between deep inspiration breath hold (DIBH) and shallow breathing (SB) in prone crawl position for photon and proton radiotherapy of whole breast (WB) and locoregional lymph node regions, including the internal mammary chain (LN_MI). We investigate the dosimetrical effects of DIBH in prone crawl position on organs-at-risk for both photon and proton plans. For each modality, we further estimate the effects of lung and heart doses on the mortality risks of different risk profiles of patients. Thirty-one patients with invasive carcinoma of the left breast and pathologically confirmed positive lymph node status were included in this study. DIBH significantly decreased dose to heart for photon and proton radiotherapy. DIBH also decreased lung doses for photons, while increased lung doses were observed using protons because the retracting heart is displaced by low-density lung tissue. For other organs-at-risk, DIBH resulted in significant dose reductions using photons while minor differences in dose deposition between DIBH and SB were observed using protons. In patients with high risks for cardiac and lung cancer mortality, average thirty-year mortality rates from radiotherapy-related cardiac injury and lung cancer were estimated at 3.12% (photon DIBH), 4.03% (photon SB), 1.80% (proton DIBH) and 1.66% (proton SB). The radiation-related mortality risk could not outweigh the ~ 8% disease-specific survival benefit of WB + LN_MI radiotherapy in any of the assessed treatments.


Asunto(s)
Mama , Contencion de la Respiración , Ganglios Linfáticos , Neoplasias de Mama Unilaterales/radioterapia , Adulto , Anciano , Supervivencia sin Enfermedad , Femenino , Humanos , Persona de Mediana Edad , Posición Prona , Terapia de Protones , Dosificación Radioterapéutica , Radioterapia Conformacional , Tasa de Supervivencia , Neoplasias de Mama Unilaterales/mortalidad
11.
Front Oncol ; 10: 558845, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33381447

RESUMEN

Meningeal tumors represent approximately 10-25% of primary brain tumors and occur usually in elderly female patients. Most meningiomas are benign (80-85%) and for symptomatic and/or large tumors, surgery, with or without radiation therapy (RT), has been long established as an effective means of local tumor control. RT can be delivered to inoperable lesions or to those with non-benign histology and for Simpson I-III and IV-V resection. RT can be delivered with photons or particles (protons or carbon ions) in stereotactic or non-stereotactic conditions. Particle therapy delivered for these tumors uses the physical properties of charged carbon ions or protons to spare normal brain tissue (i.e. Bragg peak), with or without or a dose-escalation paradigm for non-benign lesions. PT can substantially decrease the dose delivered to the non-target brain tissues, including but not limited to the hippocampi, optic apparatus or cochlea. Only a limited number of meningioma patients have been treated with PT in the adjuvant or recurrent setting, as well as for inoperable lesions with pencil beam scanning and with protons only. Approximately 500 patients with image-defined or WHO grade I meningioma have been treated with protons. The reported outcome, usually 5-year local tumor control, ranges from 85 to 99% (median, 96%). For WHO grade II or III patients, the outcome of only 97 patients has been published, reporting a median tumor local control rate of 52% (range, 38-71.1). Only 24 recurring patients treated previously with photon radiotherapy and re-treated with PT were reported. The clinical outcome of these challenging patients seems interesting, provided that they presented initially with benign tumors, are not in the elderly category and have been treated previously with conventional radiation dose of photons. Overall, the number of meningioma patients treated or-re-irradiated with this treatment modality is small and the clinical evidence level is somewhat low (i.e. 3b-5). In this review, we detail the results of upfront PT delivered to patients with meningioma in the adjuvant setting and for inoperable tumors. The outcome of meningioma patients treated with this radiation modality for recurrent tumors, with or without previous RT, will also be reviewed.

12.
Radiat Oncol ; 15(1): 266, 2020 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-33198810

RESUMEN

BACKGROUND: Despite combined modality treatment involving surgery and radiotherapy, a relevant proportion of skull-base chordoma and chondrosarcoma patients develop a local recurrence (LR). This study aims to analyze patterns of recurrence and correlate LR with a detailed dosimetric analysis. METHODS: 222 patients were treated with proton radiotherapy for chordoma (n = 151) and chondrosarcoma (n = 71) at the PSI between 1998 and 2012. All patients underwent surgery, followed by pencil-beam scanning proton therapy to a mean dose of 72.5 ± 2.2GyRBE. A retrospective patterns of recurrence analysis was performed: LR were contoured on follow-up MRI, registered with planning-imaging and the overlap with initial target structures (GTV, PTVhigh-dose, PTVlow-dose) was calculated. DVH parameters of planning structures and recurrences were calculated and correlated with LR using univariate and multivariate cox regression. RESULTS: After a median follow-up of 50 months, 35 (16%) LR were observed. Follow-up MRI imaging was available for 27 (77%) of these recurring patients. Only one (3.7%) recurrence was located completely outside the initial PTV (surgical pathway recurrence). The mean proportions of LR covered by the initial target structures were 48% (range 0-86%) for the GTV, 70% (range 0-100%) for PTVhigh and 83% (range 0-100%) for PTVlow. In the univariate analysis, the following DVH parameters were significantly associated with LR: GTV(V < 66GyRBE, p = 0.01), GTV(volume, p = 0.02), PTVhigh(max, p = 0.02), PTVhigh(V < 66GyRBE, p = 0.03), PTVhigh(V < 59GyRBE, p = 0.02), PTVhigh(volume, p = 0.01) and GTV(D95, p = 0.05). In the multivariate analysis, only histology (chordoma vs. chondrosarcoma, p = 0.01), PTVhigh(volume, p = 0.05) and GTV(V < 66GyRBE, p = 0.02) were independent prognostic factors for LR. CONCLUSION: This study identified DVH parameters, which are associated with the risk of local recurrence after proton therapy using pencil-beam scanning for patients with skull-base chordoma and chondrosarcoma.


Asunto(s)
Condrosarcoma/radioterapia , Cordoma/radioterapia , Terapia de Protones/métodos , Neoplasias de la Base del Cráneo/radioterapia , Adulto , Condrosarcoma/mortalidad , Cordoma/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Terapia de Protones/efectos adversos , Dosificación Radioterapéutica , Estudios Retrospectivos , Neoplasias de la Base del Cráneo/mortalidad , Insuficiencia del Tratamiento
13.
Radiother Oncol ; 149: 197-204, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32387488

RESUMEN

BACKGROUND AND PURPOSE: This study analyses the dosimetric and dose averaged Linear Energy transfer (LETd) correlation in paediatric craniopharyngioma (CP) patients with and without radiation-induced cerebral vasculopathies (RICVs) treated with pencil beam scanning (PBS) proton therapy (PT). MATERIAL AND METHODS: We reviewed a series of 16 CP patients treated with PT to a median dose of 54 Gy(RBE). Two (12.5%) index patients presented RICVs 14 and 24 months (median, 19) after PT. Organs at risks (OARs) as bilateral internal carotid arteries (ICAs) and circle of Willis were contoured based on CTs and MRIs pre- and post-PT. Dosimetry was reviewed and LETd distributions were calculated; LETd metric for PTVs and OARs were analysed. For a sub-cohort, dosimetric and LETd values robustness due to range uncertainties were computed. RESULTS: For the two index patients, no correlation was observed between RICVs and OARs doses. However for those patients mean(maximum) LETd values in the affected OARs were up to 4.0 ± 0.4 (7.8 ± 0.1)keV/µm; those LETd values were significantly higher (p = 0.02) than the mean(maximum) LETd values for the rest of the cohort (mean: 3.1 ± 0.3, maximum: 4.8 ± 1.0 keV/µm). This was due to asymmetric field arrangement, thus resulting in marked asymmetric LETd distributions. For such arrangement, maximum LETd values variations in vascular structures due to range uncertainties were up to 1.2 keV/µm, whilst for the symmetric one they were up to 0.7 keV/µm. CONCLUSIONS: For children with and without RICVs, quantitative analysis showed a significant correlation with LETd average/maximum values in vascular structures, whilst no correlation was found on dosimetric parameters.


Asunto(s)
Craneofaringioma , Neoplasias Hipofisarias , Terapia de Protones , Niño , Craneofaringioma/complicaciones , Craneofaringioma/radioterapia , Humanos , Transferencia Lineal de Energía , Neoplasias Hipofisarias/complicaciones , Neoplasias Hipofisarias/radioterapia , Terapia de Protones/efectos adversos , Planificación de la Radioterapia Asistida por Computador , Efectividad Biológica Relativa
14.
J Neurosurg Spine ; : 1-10, 2020 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-32005008

RESUMEN

OBJECTIVE: The aim of this paper was to evaluate the prognostic factors in surgical and adjuvant care for spinal chordomas and chondrosarcomas after surgery followed by high-dose pencil-beam scanning proton therapy (PBS-PT). METHODS: From 1997 to 2016, 155 patients (61 female patients; median age 55 years) with spinal (cervical, n = 61; thoracic, n = 29; lumbar, n = 13; sacral, n = 46; pelvic, n = 6) classic chordomas (n = 116) and chondrosarcomas (n = 39; most were low grade) were treated with maximal safe resection followed by PBS-PT (median dose prescribed: 74 Gy [relative biological effectiveness], range 48.6-77 Gy). The majority of patients (n = 153, 98.7%) had undergone at least 1 resection prior to PBS-PT (median 1, range 0-5; biopsy only, n = 2). Fewer than half (45.1%) of the surgeries were rated as gross-total resections (GTRs) prior to PBS-PT. Surgical stabilization (SS) was present in 39% of all patients (n = 60). Ninety-one patients (59%) presented with macroscopic tumor at the start of PBS-PT. The median follow-up duration was 64.7 months (range 12.2-204.8 months). RESULTS: The 5-year local tumor control, disease-free survival (DFS), and overall survival were 64.9% (95% CI 56.3%-73.5%), 59.4% (95% CI 50.6%-68.2%), and 77.9% (95% CI 70.6%-85.2%), respectively. In total, 63 patients (40.6%) experienced failure during the follow-up period: local only in 32 (20.6%), distal only in 7 (4.5%), local + distal in 19 (12.3%), surgical pathway failure (SPF) only in 2 (1.3%), local + SPF in 2 (1.3%), and distal + SPF in 1 (< 1%). Univariate analysis identified gross residual disease, the presence of SS, and treatment era prior to 2008 as highly significant for worse outcome, with all 3 remaining significant on multivariate analysis. The type of surgery (GTR or subtotal resection/biopsy) and whether GTR was achieved by en bloc or curettage did not show a significant prognostic effect. Surgical complications prior to PBS-PT were present in 42.5% of all surgically treated patients and were seen more commonly in patients with multiple surgical interventions (p = 0.005) and those operated on with the intent of en bloc resection (p = 0.006). CONCLUSIONS: The extent of resection and metallic stabilization substantially influenced clinical outcomes for patients with spinal chordoma or chondrosarcoma despite high-dose adjuvant PBS-PT. Optimal upfront surgical management of these tumors continues to include GTR, as possible, with prompt adjuvant proton therapy.

15.
Br J Radiol ; 93(1107): 20190028, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31322969

RESUMEN

OBJECTIVE: To assess the radiation-induced optic neuropathy (RION) prevalence, following high dose pencil beam scanning proton therapy (PBSPT) to skull base and head and neck (H&N) tumours. METHODS: Between 1999 and 2014, 216 adult patients, median age 47 years (range, 18-77), were treated with PBS PT for skull base or H&N malignancies, delivering ≥45 GyRBE to the optic nerve(s) (ON) and/or optic chiasma (OC). The median administered dose to the planning target volume was 74.0 GyRBE (range, 54.0-77.4). The median follow-up was 5.3 years (range, 0.8-15.9). RESULTS: RION was observed in 14 (6.5%) patients at a median time of 13.2 months (range, 4.8-42.6) following PBSPT. Most (92.9%) of RION were symptomatic. Most affected patients (11/14; 79%) developed unilateral toxicity. Grade 4, 3, 2 and 1 toxicity was observed in 10, 2, 1 and 1 patients, respectively. On univariate analyses, age (<70 vs ≥70 years; p < 0.0001), hypertension (p = 0.0007) and tumour abutting the optic apparatus (p = 0.012) were associated with RION. OC's V60 GyRBE was of border line significance (p = 0.06). None of the other evaluated OC-ON dose/volume metrics (Dmax, Dmean, V40-60) were significantly associated with this complication. CONCLUSION: These data suggest that high-dose PBS PT for skull base and H&N tumours is associated with a low prevalence of RION. Caution should be however exercised when treating elderly/hypertensive patients with tumours abutting the optic apparatus. ADVANCES IN KNOWLEDGE: This is the first study reporting the risk of developing RION following proton therapy with PBS technique, demonstrating the safety of this treatment.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Enfermedades del Nervio Óptico/etiología , Nervio Óptico/efectos de la radiación , Terapia de Protones/efectos adversos , Traumatismos por Radiación/complicaciones , Neoplasias de la Base del Cráneo/radioterapia , Adolescente , Adulto , Factores de Edad , Anciano , Análisis de Varianza , Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Hipertensión/complicaciones , Persona de Mediana Edad , Quiasma Óptico/efectos de la radiación , Enfermedades del Nervio Óptico/epidemiología , Enfermedades del Nervio Óptico/patología , Prevalencia , Terapia de Protones/métodos , Dosificación Radioterapéutica , Radioterapia Adyuvante , Factores de Riesgo , Neoplasias de la Base del Cráneo/patología , Neoplasias de la Base del Cráneo/cirugía , Adulto Joven
16.
Br J Radiol ; 93(1107): 20180883, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30943055

RESUMEN

OBJECTIVE: Large inoperable sacral chordomas show unsatisfactory local control rates even when treated with high dose proton therapy (PT). The aim of this study is assessing feasibility and reporting early results of patients treated with PT and concomitant hyperthermia (HT). METHODS:: Patients had histologically proven unresectable sacral chordomas and received 70 Gy (relative biological effectiveness) in 2.5 Gy fractions with concomitant weekly HT. Toxicity was assessed according to CTCAE_v4. A volumetric tumor response analysis was performed. RESULTS:: Five patients were treated with the combined approach. Median baseline tumor volume was 735 cc (range, 369-1142). All patients completed PT and received a median of 5 HT sessions (range, 2-6). Median follow-up was 18 months (range, 9-26). The volumetric analysis showed an objective response of all tumors (median shrinkage 46%; range, 9-72). All patients experienced acute Grade 2-3 local pain. One patient presented with a late Grade 3 iliac fracture. CONCLUSION: Combining PT and HT in large inoperable sacral chordomas is feasible and causes acceptable toxicity. Volumetric analysis shows promising early results, warranting confirmation in the framework of a prospective trial. ADVANCES IN KNOWLEDGE:: This is an encouraging first report of the feasibility and early results of concomitant HT and PT in treating inoperable sacral chordoma.


Asunto(s)
Cordoma/terapia , Hipertermia Inducida/métodos , Terapia de Protones/métodos , Sacro , Neoplasias de la Columna Vertebral/terapia , Anciano , Cordoma/diagnóstico por imagen , Cordoma/patología , Terapia Combinada/métodos , Estudios de Factibilidad , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Efectividad Biológica Relativa , Estudios Retrospectivos , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/patología , Factores de Tiempo , Resultado del Tratamiento , Carga Tumoral
18.
Sci Rep ; 9(1): 4755, 2019 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-30894606

RESUMEN

We report on a dosimetrical study comparing supine (S) and prone-crawl (P) position for radiotherapy of whole breast (WB) and loco-regional lymph node regions, including the internal mammary chain (LN_IM). Six left sided breast cancer patients were CT-simulated in S and P positions and four patients only in P position. Treatment plans were made using non-coplanar volumetric modulated arc photon therapy (VMAT) or pencil beam scanning intensity modulated proton therapy (IMPT). Dose prescription was 15*2.67 Gy(GyRBE). The average mean heart doses for S or P VMAT were 5.6 or 4.3 Gy, respectively (p = 0.16) and 1.02 or 1.08 GyRBE, respectively for IMPT (p = 0.8; p < 0.001 for IMPT versus VMAT). The average mean lung doses for S or P VMAT were 5.91 or 2.90 Gy, respectively (p = 0.002) and 1.56 or 1.09 GyRBE, respectively for IMPT (p = 0.016). In high-risk patients, average (range) thirty-year mortality rates from radiotherapy-related cardiac injury and lung cancer were estimated at 6.8(5.4-9.4)% or 3.8(2.8-5.1)% for S or P VMAT (p < 0.001), respectively, and 1.6(1.1-2.0)% or 1.2(0.8-1.6)% for S or P IMPT (p = 0.25), respectively. Radiation-related mortality risk could outweigh the ~8% disease-specific survival benefit of WB + LN_IM radiotherapy for S VMAT but not P VMAT. IMPT carries the lowest radiation-related mortality risks.


Asunto(s)
Fotones/uso terapéutico , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia/efectos adversos , Neoplasias de Mama Unilaterales/radioterapia , Mama/patología , Mama/efectos de la radiación , Mama/cirugía , Femenino , Corazón/efectos de la radiación , Humanos , Pulmón/efectos de la radiación , Ganglios Linfáticos/patología , Ganglios Linfáticos/efectos de la radiación , Mastectomía Segmentaria , Órganos en Riesgo/efectos de la radiación , Fotones/efectos adversos , Posición Prona , Terapia de Protones/efectos adversos , Radiometría , Radioterapia/mortalidad , Dosificación Radioterapéutica , Estudios Retrospectivos , Riesgo , Neoplasias de Mama Unilaterales/patología , Neoplasias de Mama Unilaterales/cirugía
19.
Phys Med Biol ; 64(6): 065021, 2019 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-30641496

RESUMEN

For pencil beam scanned (PBS) proton therapy, analytical dose calculation engines are still typically used for the optimisation process, and often for the final evaluation of the plan. Recently however, the suitability of analytical calculations for planning PBS treatments has been questioned. Conceptually, the two main approaches for these analytical dose calculations are the ray-casting (RC) and the pencil-beam (PB) method. In this study, we compare dose distributions and dosimetric indices, calculated on both the clinical dose calculation grid and as a function of dose grid resolution, to Monte Carlo (MC) calculations. The analysis is done using a comprehensive set of clinical plans which represent a wide choice of treatment sites. When analysing dose difference histograms for relative treatment plans, pencil beam calculations with double grid resolution perform best, with on average 97.7%/91.9% (RC), 97.9%/92.7% (RC, double grid resolution), 97.6%/91.0% (PB) and 98.6%/94.0% (PB, double grid resolution) of voxels agreeing within ±5%/± 3% between the analytical and the MC calculations. Even though these point-to-point dose comparison shows differences between analytical and MC calculations, for all algorithms, clinically relevant dosimetric indices agree within ±4% for the PTV and within ±5% for critical organs. While the clinical agreement depends on the treatment site, there is no substantial difference of indices between the different algorithms. The pencil-beam approach however comes at a higher computational cost than the ray-casting calculation. In conclusion, we would recommend using the ray-casting algorithm for fast dose optimization and subsequently combine it with one MC calculation to scale the absolute dose and assure the quality of the treatment plan.


Asunto(s)
Algoritmos , Método de Montecarlo , Neoplasias/radioterapia , Fantasmas de Imagen , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica
20.
Int J Radiat Oncol Biol Phys ; 101(1): 226-233, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29619966

RESUMEN

PURPOSE: To evaluate the efficacy and safety of high-dose pencil-beam scanning proton therapy (PBS-PT) in the adjuvant treatment of spinal chordomas. METHODS AND MATERIALS: Between 1997 and 2015, 100 patients with spinal chordomas (median age, 56 years; range, 25-81 years) were treated with adjuvant PBS-PT at the Paul Scherrer Institute: cervical (n = 46), thoracic (n = 4), lumbar (n = 12), and sacral (n = 38). The majority (88%) received PBS-PT alone rather than combined photon-proton therapy. The median radiation therapy dose prescribed was 74 Gy (relative biological effectiveness [RBE]) (range, 59.4-77 Gy [RBE]). Thirty-nine patients (39%) had undergone surgical stabilization, primarily with titanium hardware, before radiation therapy. RESULTS: With a median follow-up of 65 months (range, 13-175 months), 5-year local control, disease control, and overall survival rates were 63% (95% confidence interval [CI] 57.7-68.7%; median, 103 months), 57% (95% CI 50.9-62.1%; median, 82 months), and 81% (95% CI 76.8-85.6%; median, 157 months), respectively. On univariate and multivariate analyses, the presence of surgical stabilization was highly prognostic for worsened outcomes. Multivariate analysis also revealed the extent of treatment volumes and presence of gross residual disease to be important in predicting outcomes. High-grade (grade ≥3) toxicities were rare in both the acute (8%) and late (6%) settings. CONCLUSION: For spinal chordomas, PBS-PT remains a highly effective and safe method for delivery of dose-escalated adjuvant radiation therapy. The presence of metallic surgical stabilization prognosticates for worsened outcomes. Further investigation is warranted to characterize ideal treatment volumes and effect of surgical stabilization on therapy for these challenging tumors.


Asunto(s)
Cordoma/radioterapia , Terapia de Protones/métodos , Neoplasias de la Columna Vertebral/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Cordoma/mortalidad , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Terapia de Protones/efectos adversos , Dosificación Radioterapéutica , Efectividad Biológica Relativa , Neoplasias de la Columna Vertebral/mortalidad , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA