Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Clin Microbiol ; 58(10)2020 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-32690547

RESUMEN

Control of the ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic requires accurate laboratory testing to identify infected individuals while also clearing essential staff to continue to work. At the current time, a number of quantitative real-time PCR (qRT-PCR) assays have been developed to identify SARS-CoV-2, targeting multiple positions in the viral genome. While the mutation rate of SARS-CoV-2 is moderate, given the large number of transmission chains, it is prudent to monitor circulating viruses for variants that might compromise these assays. Here, we report the identification of a C-to-U transition at position 26340 of the SARS-CoV-2 genome that is associated with failure of the cobas SARS-CoV-2 E gene qRT-PCR in eight patients. As the cobas SARS-CoV-2 assay targets two positions in the genome, the individuals carrying this variant were still called SARS-CoV-2 positive. Whole-genome sequencing of SARS-CoV-2 showed all to carry closely related viruses. Examination of viral genomes deposited on GISAID showed this mutation has arisen independently at least four times. This work highlights the necessity of monitoring SARS-CoV-2 for the emergence of single-nucleotide polymorphisms that might adversely affect RT-PCRs used in diagnostics. Additionally, it argues that two regions in SARS-CoV-2 should be targeted to avoid false negatives.


Asunto(s)
Betacoronavirus/genética , Proteínas del Envoltorio Viral/genética , Betacoronavirus/clasificación , Betacoronavirus/aislamiento & purificación , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Proteínas de la Envoltura de Coronavirus , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/virología , Bases de Datos Genéticas , Reacciones Falso Negativas , Genoma Viral/genética , Humanos , Técnicas de Diagnóstico Molecular , Mutación , Filogenia , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2
2.
Malar J ; 19(1): 121, 2020 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-32197607

RESUMEN

BACKGROUND: The loss of chloroquine (CQ) effectiveness has led to its withdrawal from national policies as a first-line treatment for uncomplicated malaria in several endemic countries, such as the Democratic Republic of Congo (DRC). The K76T mutation on the pfcrt gene has been identified as a marker of CQ resistance and the SVMNT haplotype in codons 72-76 on the same gene has been associated with resistance to amodiaquine (AQ). In the DRC, the prevalence of K76T has decreased from 100% in 2000 to 63.9% in 2014. The purpose of this study was to determine the prevalence of K76T mutations in circulating strains of Plasmodium falciparum, 16 years after CQ withdrawal in the DRC and to investigate the presence of the SVMNT haplotype. METHODS: In 2017, ten geographical sites across the DRC were selected. Dried blood samples were collected from patients attending health centres. Malaria was first detected by a rapid diagnostic test (RDT) available on site (SD Bioline Malaria Ag Pf or CareStart Malaria Pf) or thick blood smear and then confirmed by a P. falciparum species-specific real-time PCR assay. A pfcrt gene segment containing a fragment that encodes amino acids at positions 72-76 was amplified by conventional PCR before sequencing. RESULTS: A total of 1070 patients were enrolled. Of the 806 PCR-confirmed P. falciparum positive samples, 764 were successfully sequenced. The K76T mutation was detected in 218 samples (28.5%; 95% CI 25.4%-31.9%), mainly (96%) with the CVIET haplotype. Prevalence of CQ resistance marker was unequally distributed across the country, ranging from 1.5% in Fungurume to 89.5% in Katana. The SVMNT haplotype, related to AQ resistance, was not detected. CONCLUSION: Overall, the frequency of the P. falciparum CQ resistance marker has decreased significantly and no resistance marker to AQ was detected in the DRC in 2017. However, the between regions variability of CQ resistance remains high in the country. Further studies are needed for continuous monitoring of the CQ resistance level for its prospective re-use in malaria management. The absence of the AQ resistance marker is in line with the use of this drug in the current DRC malaria treatment policy.


Asunto(s)
Amodiaquina/uso terapéutico , Antimaláricos/uso terapéutico , Cloroquina/uso terapéutico , Resistencia a Medicamentos/genética , Malaria Falciparum/tratamiento farmacológico , Proteínas de Transporte de Membrana/genética , Proteínas Protozoarias/genética , Adolescente , Adulto , Anciano , Niño , Preescolar , República Democrática del Congo/epidemiología , Pruebas con Sangre Seca , Humanos , Lactante , Recién Nacido , Malaria Falciparum/epidemiología , Tamizaje Masivo , Persona de Mediana Edad , Mutación , Plasmodium falciparum/genética , Polimorfismo Genético , Estudios Prospectivos , Adulto Joven
3.
J Virol Methods ; 270: 137-145, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31121188

RESUMEN

Real-time PCR are often used for the diagnosis and monitoring of Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) infections in susceptible populations. In this context, we evaluated the analytical performances of the Abbott RealTime CMV/EBV maxCycle protocol automated on the m2000 platform (Abbott). It was compared to our routinely-used procedure consisting of a NucleoMag® DNA extraction automated on a STARlet platform followed by manually processed CMV and EBV quantitative real-time PCR (Diagenode). In this study, we showed that both EBV assays exhibited a similar sensitivity but with a better precision for the EBV Abbott RealTime assay. For the CMV performances, the Abbott assay was more sensitive and more precise than our routine method. The use of WHO International Standards also indicated a slight underestimation of the viral loads (-0.25 log10 IU/mL and -0.21 log10 IU/mL for CMV and EBV assays respectively) while these were rather overestimated with the Starlet/Diagenode method (0.48 log10 IU/mL and 0.19 log10 IU/mL for CMV and EBV assays respectively). These trends were confirmed using relevant whole-blood clinical samples and external quality controls. The workflows were also compared and we highlighted a significant technician hands-on time reduction (-63%) using the Abbott CMV/EBV maxCycle automated protocol.


Asunto(s)
Sangre/virología , Citomegalovirus/aislamiento & purificación , Herpesvirus Humano 4/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Carga Viral/métodos , Automatización de Laboratorios/métodos , Citomegalovirus/genética , Herpesvirus Humano 4/genética , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Manejo de Especímenes/métodos , Carga Viral/normas
4.
Vet Res ; 33(2): 159-68, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-11944805

RESUMEN

Neospora caninum and Toxoplasma gondii are cyst-forming coccidian parasites of human and veterinary clinical relevance. In vitro cultivation of the protozoans using Vero cells is usually performed in order to produce antigenic materials. Quantitative and qualitative comparisons of Vero cells grown in RPMI medium supplemented either with foetal calf serum (FCS), horse serum (HS) or a specific serum-free additive (DefCell) were performed. A serum-free cell culture system used to propagate N. caninum (NC-1 isolate) and T. gondii tachyzoites (Rh stain) were compared with the other two cell culture systems. FCS supplemented media was found to be more effective than the others in promoting Vero cells and N. caninum tachyzoites. However, it was found unable to support adequate T. gondii tachyzoite proliferation. Vero cells, T. gondii and N. caninum tachyzoite production gave similar growth patterns with either HS or DefCell supplemented media. Defcell was considered as a good alternative to supplement culture medium.


Asunto(s)
Neospora/crecimiento & desarrollo , Toxoplasma/crecimiento & desarrollo , Animales , Recuento de Células , Chlorocebus aethiops , Medios de Cultivo , Medio de Cultivo Libre de Suero , Parasitología/métodos , Factores de Tiempo , Células Vero
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA