1.
Radiology ; 311(1): e240588, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38652029

RESUMEN

Supplemental material is available for this article. See also the article by Lenkinski and Rofsky in this issue. See also the article by McKee et al in this issue.


Asunto(s)
Gases de Efecto Invernadero , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/economía
2.
J Cardiovasc Magn Reson ; 25(1): 1, 2023 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-36642713

RESUMEN

BACKGROUND: Left ventricular (LV) contractility and compliance are derived from pressure-volume (PV) loops during dynamic preload reduction, but reliable simultaneous measurements of pressure and volume are challenging with current technologies. We have developed a method to quantify contractility and compliance from PV loops during a dynamic preload reduction using simultaneous measurements of volume from real-time cardiovascular magnetic resonance (CMR) and invasive LV pressures with CMR-specific signal conditioning. METHODS: Dynamic PV loops were derived in 16 swine (n = 7 naïve, n = 6 with aortic banding to increase afterload, n = 3 with ischemic cardiomyopathy) while occluding the inferior vena cava (IVC). Occlusion was performed simultaneously with the acquisition of dynamic LV volume from long-axis real-time CMR at 0.55 T, and recordings of invasive LV and aortic pressures, electrocardiogram, and CMR gradient waveforms. PV loops were derived by synchronizing pressure and volume measurements. Linear regression of end-systolic- and end-diastolic- pressure-volume relationships enabled calculation of contractility. PV loops measurements in the CMR environment were compared to conductance PV loop catheter measurements in 5 animals. Long-axis 2D LV volumes were validated with short-axis-stack images. RESULTS: Simultaneous PV acquisition during IVC-occlusion was feasible. The cardiomyopathy model measured lower contractility (0.2 ± 0.1 mmHg/ml vs 0.6 ± 0.2 mmHg/ml) and increased compliance (12.0 ± 2.1 ml/mmHg vs 4.9 ± 1.1 ml/mmHg) compared to naïve animals. The pressure gradient across the aortic band was not clinically significant (10 ± 6 mmHg). Correspondingly, no differences were found between the naïve and banded pigs. Long-axis and short-axis LV volumes agreed well (difference 8.2 ± 14.5 ml at end-diastole, -2.8 ± 6.5 ml at end-systole). Agreement in contractility and compliance derived from conductance PV loop catheters and in the CMR environment was modest (intraclass correlation coefficient 0.56 and 0.44, respectively). CONCLUSIONS: Dynamic PV loops during a real-time CMR-guided preload reduction can be used to derive quantitative metrics of contractility and compliance, and provided more reliable volumetric measurements than conductance PV loop catheters.


Asunto(s)
Cateterismo Cardíaco , Isquemia Miocárdica , Porcinos , Animales , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Función Ventricular Izquierda , Volumen Sistólico
3.
J Thorac Imaging ; 37(4): 201-216, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35426857

RESUMEN

Magnetic resonance imaging (MRI) is used for the guidance and follow-up of percutaneous minimally invasive interventions in many body parts. In the thorax, computed tomography (CT) is currently the most used imaging modality for the guidance and follow-up of needle biopsies and thermal ablations. Compared with CT, MRI provides excellent soft tissue contrast, lacks ionizing radiation, and allows functional imaging. The role of MRI is limited in the thorax due to the low hydrogen proton density and many air-tissue interfaces of the lung, as well as respiratory and cardiac motion. Here, we review the current experience of MR-guided thoracic needle biopsies and of MR-guided thermal ablations targeting lesions in the lung, mediastinum, and the chest wall. We provide an overview of MR-compatible biopsy needles and ablation devices. We detail relevant MRI sequences and their relative advantages and disadvantages for procedural guidance, assessment of complications, and long-term follow-up. We compare the advantages and disadvantages of CT and MR for thoracic interventions and identify areas in need of improvement and additional research.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Biopsia con Aguja , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Tórax
4.
Invest Radiol ; 57(3): 178-186, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34652290

RESUMEN

OBJECTIVES: Contemporary lower-field magnetic resonance imaging (MRI) may offer advantages for lung imaging by virtue of the improved field homogeneity. The aim of this study was to evaluate the utility of lower-field MRI for combined morphologic imaging and regional lung function assessment. We evaluate low-field MRI in patients with lymphangioleiomyomatosis (LAM), a rare lung disease associated with parenchymal cysts and respiratory failure. MATERIALS AND METHODS: We performed lung imaging on a prototype low-field (0.55 T) MRI system in 65 patients with LAM. T2-weighted imaging was used for assessment of lung morphology and to derive cyst scores, the percent of lung parenchyma occupied by cysts. Regional lung function was assessed using oxygen-enhanced MRI with breath-held ultrashort echo time imaging and inhaled 100% oxygen as a T1-shortening MR contrast agent. Measurements of percent signal enhancement from oxygen inhalation and percentage of lung with low oxygen enhancement, indicating functional deficits, were correlated with global pulmonary function test measurements taken within 2 days. RESULTS: We were able to image cystic abnormalities using T2-weighted MRI in this patient population and calculate cyst score with strong correlation to computed tomography measurements (R = 0.86, P < 0.0001). Oxygen-enhancement maps demonstrated regional deficits in lung function of patients with LAM. Heterogeneity of oxygen enhancement between cysts was observed within individual patients. The percent low-enhancement regions showed modest, but significant, correlation with FEV1 (R = -0.37, P = 0.007), FEV1/FVC (R = -0.33, P = 0.02), and cyst score (R = 0.40, P = 0.02). The measured arterial blood ΔT1 between normoxia and hyperoxia, used as a surrogate for dissolved oxygen in blood, correlated with DLCO (R = -0.28, P = 0.03). CONCLUSIONS: Using high-performance 0.55 T MRI, we were able to perform simultaneous imaging of pulmonary structure and regional function in patients with LAM.


Asunto(s)
Quistes , Linfangioleiomiomatosis , Quistes/complicaciones , Humanos , Pulmón/diagnóstico por imagen , Linfangioleiomiomatosis/complicaciones , Linfangioleiomiomatosis/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Oxígeno/química
5.
J Magn Reson Imaging ; 55(6): 1855-1863, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34668604

RESUMEN

BACKGROUND: MRI T2* and R2* mapping have gained clinical acceptance for noninvasive assessment of iron overload. Lower field MRI may offer increased measurement dynamic range in patients with high iron concentration and may potentially increase MRI accessibility, but it is compromised by lower signal-to-noise ratio that reduces measurement precision. PURPOSE: To characterize a high-performance 0.55 T MRI system for evaluating patients with liver iron overload. STUDY TYPE: Prospective. POPULATION: Forty patients with known or suspected iron overload (sickle cell anemia [n = 5], ß-thalassemia [n = 3], and hereditary spherocytosis [n = 2]) and a liver iron phantom. FIELD STRENGTH/SEQUENCE: A breath-held multiecho gradient echo sequence at 0.55 T and 1.5 T. ASSESSMENT: Patients were imaged with T2*/R2* mapping 0.55 T and 1.5 T within 24 hours, and 16 patients returned for follow-up exams within 6-16 months, resulting in 56 paired studies. Liver T2* and R2* measurements and standard deviations were compared between 0.55 T and 1.5 T and used to validate a predictive model between field strengths. The model was then used to classify iron overload at 0.55 T. STATISTICAL TESTS: Linear regression and Bland-Altman analysis were used for comparisons, and measurement precision was assessed using the coefficient of variation. A P-value < 0.05 was considered statistically significant. RESULTS: R2* was significantly lower at 0.55 T in our cohort (488 ± 449 s-1 at 1.5 T vs. 178 ± 155 s-1 at 0.55 T, n = 56 studies) and in the patients with severe iron overload (937 ± 369 s-1 at 1.5 T vs. 339 ± 127 s-1 at 0.55 T, n = 23 studies). The coefficient of variation indicated reduced precision at 0.55 T (3.5 ± 2.2% at 1.5 T vs 6.9 ± 3.9% at 0.55 T). The predictive model accurately predicted 1.5 T R2* from 0.55 T R2* (Bland Altman bias = -6.6 ± 20.5%). Using this model, iron overload at 0.55 T was classified as: severe R2* > 185 s-1 , moderate 81 s-1  < R2* < 185 s-1 , and mild 45 s-1  < R2* < 91 s-1 . DATA CONCLUSION: We demonstrated that 0.55 T provides T2* and R2* maps that can be used for the assessment of liver iron overload in patients. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Sobrecarga de Hierro , Humanos , Hierro/análisis , Sobrecarga de Hierro/diagnóstico por imagen , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos
6.
NMR Biomed ; 34(8): e4562, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34080253

RESUMEN

The purpose of this study was to evaluate oxygen-enhanced pulmonary imaging at 0.55 T with 3D stack-of-spirals ultrashort-TE (UTE) acquisition. Oxygen-enhanced pulmonary MRI offers the measurement of regional lung ventilation and perfusion using inhaled oxygen as a contrast agent. Low-field MRI systems equipped with contemporary hardware can provide high-quality structural lung imaging by virtue of the prolonged T2 *. Fortuitously, the T1 relaxivity of oxygen increases at lower field strengths, which is expected to improve the sensitivity of oxygen-enhanced lung MRI. We implemented a breath-held T1 -weighted 3D stack-of-spirals UTE acquisition with a 7 ms spiral-out readout. Measurement repeatability was assessed using five repetitions of oxygen-enhanced lung imaging in healthy volunteers (n = 7). The signal intensity at both normoxia and hyperoxia was strongly dependent on lung tissue density modulated by breath-hold volume during the five repetitions. A voxel-wise correction for lung tissue density improved the repeatability of percent signal enhancement maps (coefficient of variation = 34 ± 16%). Percent signal enhancement maps were compared in 15 healthy volunteers and 10 patients with lymphangioleiomyomatosis (LAM), a rare cystic disease known to reduce pulmonary function. We measured a mean percent signal enhancement of 9.0 ± 3.5% at 0.55 T in healthy volunteers, and reduced signal enhancement in patients with LAM (5.4 ± 4.8%, p = 0.02). The heterogeneity, estimated by the percent of lung volume exhibiting low enhancement, was significantly increased in patients with LAM compared with healthy volunteers (11.1 ± 6.0% versus 30.5 ± 13.1%, p = 0.01), illustrating the capability to measure regional functional deficits.


Asunto(s)
Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Oxígeno/química , Adulto , Femenino , Voluntarios Sanos , Humanos , Imagenología Tridimensional , Pulmón/patología , Linfangioleiomiomatosis , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador
7.
J Cardiovasc Magn Reson ; 20(1): 62, 2018 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-30201013

RESUMEN

BACKGROUND: The hallmark of heart failure is increased blood volume. Quantitative blood volume measures are not conveniently available and are not tested in heart failure management. We assess ferumoxytol, a marketed parenteral iron supplement having a long intravascular half-life, to measure the blood volume with cardiovascular magnetic resonance (CMR). METHODS: Swine were administered 0.7 mg/kg ferumoxytol and blood pool T1 was measured repeatedly for an hour to characterize contrast agent extraction and subsequent effect on Vblood estimates. We compared CMR blood volume with a standard carbon monoxide rebreathing method. We then evaluated three abbreviated acquisition protocols for bias and precision. RESULTS: Mean plasma volume estimated by ferumoxytol was 61.9 ± 4.3 ml/kg. After adjustment for hematocrit the resultant mean blood volume was 88.1 ± 9.4 ml/kg, which agreed with carbon monoxide measures (91.1 ± 18.9 ml/kg). Repeated measurements yielded a coefficient of variation of 6.9%, and Bland-Altman repeatability coefficient of 14%. The blood volume estimates with abbreviated protocols yielded small biases (mean differences between 0.01-0.06 L) and strong correlations (r2 between 0.97-0.99) to the reference values indicating clinical feasibility. CONCLUSIONS: In this swine model, ferumoxytol CMR accurately measures plasma volume, and with correction for hematocrit, blood volume. Abbreviated protocols can be added to diagnostic CMR examination for heart failure within 8 min.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Volumen Sanguíneo , Medios de Contraste/administración & dosificación , Óxido Ferrosoférrico/administración & dosificación , Imagen por Resonancia Magnética , Animales , Monóxido de Carbono/administración & dosificación , Modelos Animales , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sus scrofa
8.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-28874164

RESUMEN

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías/diagnóstico , Imagen por Resonancia Magnética Intervencional , Exposición a la Radiación/prevención & control , Adolescente , Factores de Edad , Niño , Estudios de Factibilidad , Femenino , Cardiopatías/fisiopatología , Hemodinámica , Humanos , Masculino , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Factores de Tiempo
9.
J Magn Reson Imaging ; 46(4): 935-950, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28493526

RESUMEN

Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:935-950.


Asunto(s)
Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/terapia , Imagen por Resonancia Magnética Intervencional/métodos , Enfermedades Cardiovasculares/cirugía , Corazón/diagnóstico por imagen , Humanos
10.
Sci Rep ; 7: 43439, 2017 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-28240317

RESUMEN

ß-thalassemia (ßT) is a genetic blood disorder causing profound and life threatening anemia. Current clinical management of ßT is a lifelong dependence on regular blood transfusions, a consequence of which is systemic iron overload leading to acute heart failure. Recent developments in gene and chelation therapy give hope of better prognosis for patients, but successful translation to clinical practice is hindered by the lack of thorough preclinical testing using representative animal models and clinically relevant quantitative biomarkers. Here we demonstrate a quantitative and non-invasive preclinical Magnetic Resonance Imaging (MRI) platform for the assessment of ßT in the γß0/γßA humanized mouse model of ßT. Changes in the quantitative MRI relaxation times as well as severe splenomegaly were observed in the heart, liver and spleen in ßT. These data showed high sensitivity to iron overload and a strong relationship between quantitative MRI relaxation times and hepatic iron content. Importantly these changes preceded the onset of iron overload cardiomyopathy, providing an early biomarker of disease progression. This work demonstrates that multiparametric MRI is a powerful tool for the assessment of preclinical ßT, providing sensitive and quantitative monitoring of tissue iron sequestration and cardiac dysfunction- parameters essential for the preclinical development of new therapeutics.


Asunto(s)
Corazón/diagnóstico por imagen , Sobrecarga de Hierro/diagnóstico por imagen , Hígado/diagnóstico por imagen , Bazo/diagnóstico por imagen , Esplenomegalia/diagnóstico por imagen , Talasemia beta/diagnóstico por imagen , Animales , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/metabolismo , Cardiomiopatías/patología , Modelos Animales de Enfermedad , Femenino , Corazón/fisiopatología , Humanos , Hierro/análisis , Hierro/metabolismo , Sobrecarga de Hierro/metabolismo , Sobrecarga de Hierro/patología , Hígado/metabolismo , Hígado/patología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Masculino , Ratones , Ratones Transgénicos , Bazo/metabolismo , Bazo/patología , Esplenomegalia/metabolismo , Esplenomegalia/patología , Talasemia beta/metabolismo , Talasemia beta/patología
11.
JACC Basic Transl Sci ; 1(5): 376-383, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27631028

RESUMEN

BACKGROUND: Diagnostic yield of endomyocardial biopsy is low, particularly in disease that affects the myocardium in a non-uniform distribution. We hypothesized that real-time MRI guidance could improve the yield through targeted biopsy of focal myocardial pathology. METHODS: An animal model of focal myocardial pathology was created by infusing 3mL of fluorescent microspheres (NuFlow Hydrocoat, 15µm diameter, 5 million spheres/mL) followed by 2mL of 100% ethanol to a branch coronary artery. Animals were survived for minimum 14days, before undergoing MRI guided endomyocardial biopsy using a custom 6.5Fr active visualization MRI-conditional bioptome and X-ray guided biopsy using a commercial bioptome. Specimens were analyzed using a dissecting microscope under ultraviolet light to determine the proportion of 'on-target' specimens containing fluorescent microspheres. RESULTS: A total of 77 specimens were obtained using real-time MRI guidance and 87 using X-ray guidance, in five animals. Specimens obtained with the MRI-conditional bioptome were smaller compared with the commercial X-ray bioptome. Real-time MRI guidance significantly increased the diagnostic yield of endomyocardial biopsy (82% vs. 56% on-target biopsy specimens with real-time MRI vs. X-ray guidance, p<0.01). CONCLUSIONS: Endomyocardial biopsy performed using real-time MRI guidance is feasible and significantly improves the diagnostic yield compared with X-ray fluoroscopy guidance.

12.
Br J Cancer ; 114(8): 897-904, 2016 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-27031853

RESUMEN

BACKGROUND: Non-invasive measures of tumour vascular perfusion are desirable, in order to assess response to vascular targeting (or modifying) therapies. In this study, hepatic arterial spin labelling (ASL) magnetic resonance imaging (MRI) was investigated to measure acute changes in perfusion of colorectal cancer in the liver, in response to vascular disruption therapy with OXi4503. METHODS: SW1222 and LS174T tumours were established in the liver of MF1 nu/nu mice via intrasplenic injection. Perfusion and R2(*) MRI measurements were acquired with an Agilent 9.4T horizontal bore scanner, before and at 90 min after 40 mg kg(-1) OXi4503. RESULTS: A significant decrease in SW1222 tumour perfusion was observed (-43±33%, P<0.005). LS174T tumours had a significantly lower baseline level of perfusion. Intrinsic susceptibility MRI showed a significant increase in R2(*) in LS174T tumours (28±25%, P<0.05). An association was found between the change in tumour perfusion and the proximity to large vessels, with pre-treatment blood flow predictive of subsequent response. Histological evaluation confirmed the onset of necrosis and evidence of heterogeneous response between tumour deposits. CONCLUSIONS: Hepatic ASL-MRI can detect acute response to targeted tumour vascular disruption entirely non-invasively. Hepatic ASL of liver tumours has potential for use in a clinical setting.


Asunto(s)
Arteria Hepática/patología , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patología , Hígado/patología , Animales , Línea Celular Tumoral , Neoplasias Colorrectales/patología , Femenino , Angiografía por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Ratones , Ratones Desnudos , Marcadores de Spin
13.
Amyloid ; 20(2): 93-8, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23621497

RESUMEN

We report the in vivo evaluation, in a murine model, of MRI measurements of the extracellular volume fraction (ECV) for the detection and monitoring of systemic amyloidosis. A new inducible transgenic model was used, with increased production of mouse serum amyloid A protein controlled by oral administration of doxycycline, that causes both the usual hepatic and splenic amyloidosis and also cardiac deposits. ECV was measured in vivo by equilibrium contrast MRI in the heart and liver of 11 amyloidotic and 10 control mice. There was no difference in the cardiac function between groups, but ECV was significantly increased in the heart, mean (standard deviation) 0.20 (0.05) versus 0.14 (0.04), p < 0.005, and liver, 0.27 (0.04) versus 0.15 (0.04), p < 0.0005, of amyloidotic animals and was strongly correlated with the histological amyloid score, myocardium, ρ = 0.67, p < 0.01; liver, ρ = 0.87, p < 0.01. In a further four mice that received human serum amyloid P component (SAP) followed by anti-human SAP antibody, a treatment to eliminate visceral amyloid deposits, ECV in the liver and spleen returned to baseline after therapy (p < 0.01). MRI measurement of ECV is a sensitive marker of amyloid deposits with potential application for early detection and monitoring therapies promoting their clearance.


Asunto(s)
Amiloide/metabolismo , Amiloidosis/diagnóstico , Líquido Extracelular/metabolismo , Hígado/patología , Imagen por Resonancia Magnética , Miocardio/patología , Bazo/patología , Amiloidosis/metabolismo , Amiloidosis/patología , Animales , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/metabolismo , Masculino , Ratones , Ratones Transgénicos , Miocardio/metabolismo , Radiografía , Proteína Amiloide A Sérica/metabolismo , Componente Amiloide P Sérico/inmunología , Componente Amiloide P Sérico/metabolismo , Bazo/diagnóstico por imagen , Bazo/metabolismo
14.
PLoS One ; 8(1): e54903, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23382996

RESUMEN

OBJECTIVES: To use primed infusions of the magnetic resonance imaging (MRI) contrast agent Gd.DTPA (Magnevist), to achieve an equilibrium between blood and tissue (eqMRI). This may increase tumor Gd concentrations as a novel cancer imaging methodology for the enhancement of small tumor nodules within the low signal-to-noise background of the lung. METHODS: A primed infusion with a delay before equilibrium (eqMRI) of the Gd(III) chelator Gd.DTPA, via the intraperitoneal route, was used to evaluate gadolinium tumor enhancement as a function of a bolus injection, which is applied routinely in the clinic, compared to gadolinium maintained at equilibrium. A double gated (respiration and cardiac) spin-echo sequence at 9.4T was used to evaluate whole lungs pre contrast and then at 15 (representative of bolus enhancement), 25 and 35 minutes (representative of eqMRI). This was carried out in two lung metastasis models representative of high and low tumor cell seeding. Lungs containing discrete tumor nodes where inflation fixed and taken for haematoxylin and eosin staining as well as CD34 staining for correlation to MRI. RESULTS: We demonstrate that sustained Gd enhancement, afforded by Gd equilibrium, increases the detection of pulmonary metastases compared to bolus enhancement and those tumors which enhance at equilibrium are sub-millimetre in size (<0.7 mm(2)) with a similar morphology to early bronchoalveolar cell carcinomas. CONCLUSION: As Gd-chelates are routinely used in the clinic for detecting tumors by MRI, this methodology is readily transferable to the clinic and advances MRI as a methodology for the detection of small pulmonary tumors.


Asunto(s)
Gadolinio DTPA/farmacocinética , Infusiones Parenterales/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Carga Tumoral , Animales , Quelantes/administración & dosificación , Quelantes/química , Quelantes/farmacocinética , Medios de Contraste/administración & dosificación , Medios de Contraste/química , Medios de Contraste/farmacocinética , Gadolinio/química , Gadolinio DTPA/administración & dosificación , Gadolinio DTPA/química , Células HEK293 , Humanos , Neoplasias Pulmonares/metabolismo , Masculino , Metástasis de la Neoplasia , Factores de Tiempo