Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Arthroplasty ; 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38355066

RESUMEN

BACKGROUND: Robotic-assisted total knee arthroplasty is increasingly used in revision total knee arthroplasty (rTKA), with imageless systems recently receiving Food and Drug Administration (FDA) approval. However, there remains a paucity of literature on the use of robotic assistance in revision total knee arthroplasty (TKA). This paper describes the imageless surgical technique for robotic revision TKA using a second-generation robotic system and details both intraoperative and 90-day outcomes. METHODS: This was a retrospective review of 115 robotic revision TKAs from March 2021 to May 2023 at 3 tertiary academic centers. Patient demographics, perioperative surgical data, and 90-day outcomes were collected. Pain and Patient-Reported Outcomes Measurement Information System scores preoperatively and postoperatively were recorded. All-cause reoperations at the final follow-up were detailed. The mean patient age was 65 years (range, 43 to 88), and 58% were women. The mean follow-up time was 13 months (range, 3 to 51). RESULTS: The most common indications for rTKA were instability (n = 37, 32%) and aseptic loosening (n = 42, 37%). There were 83 rTKAs to a posterior-stabilized liner, 22 to a varus-valgus constrained liner, and 5 to a hinged construct. The median polyethylene size was 11 (interquartile range, 10 to 13), and 93% of patients had their joint line restored within 5 millimeters of the native contralateral knee. Within the 90-day postoperative window, there were 8 emergency department visits and 2 readmissions. At the final follow-up, there were 5 reoperations and 2 manipulations under anesthesia. There were 4 patients who required irrigation and debridement after superficial wound dehiscence, and one had an arthrotomy disruption after a fall. CONCLUSIONS: This review demonstrates favorable intraoperative and 90-day outcomes and suggests that imageless robotic surgery is a promising modality in rTKA. Further studies comparing the longitudinal outcomes after robotic and conventional rTKA are warranted.

2.
J Arthroplasty ; 39(7): 1771-1776, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38103802

RESUMEN

BACKGROUND: The use of technology allows surgeons increased precision in component positioning in total hip arthroplasty (THA). The objective of this study was to compare (1) perioperative complications and (2) resource utilizations between robotic-assisted (RA) and computer-navigated (CN) versus conventional instrumenttaion (CI) THA. METHODS: A retrospective cohort study was performed using a large national database to identify patients undergoing unilateral, primary elective THA from January 1, 2016 to December 31, 2019 using RA, CN, or CI. There were 1,372,300 total patients identified and included RA (29,735), CN (28,480), and CI (1,314,085) THA. Demographics, complications, lengths of stay, dispositions, and costs were compared between the cohorts. Binary logistic regression analyses were performed. RESULTS: The use of RA THA led to lower rates of intraoperative fracture (0.22% versus 0.39%), delirium (0.1% versus 0.2%), postoperative anemia (14.4% versus 16.7%), higher myocardial infarction (0.13% versus 0.08%), renal failure (1.7% versus 1.6%), blood transfusion (2.0% versus 1.9%), and wound dehiscence (0.02% versus 0.01%) compared to CI THA. The use of CN led to lower rates of respiratory complication (0.5% versus 0.8%), renal failure (1.1% versus 1.6%), blood transfusion (1.3% versus 1.9%), and pulmonary embolism (0.02% versus 0.1%) compared to CI THA. Total costs were increased in RA ($17,729 versus $15,977) and CN ($22,529 versus $15,977). Lengths of hospital stay were decreased in RA (1.8 versus 1.9 days) and CN (1.7 versus 1.9 days). CONCLUSIONS: Perioperative complication rates vary in technology-assisted THA, with higher rates in RA THA and lower rates in CN THA, relative to CI THA. Both RA THA and CN THA were associated with more costs, shorter postoperative hospital stays, and higher rates of discharge home compared to CI THA.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Cadera/economía , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/efectos adversos , Masculino , Femenino , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/economía , Persona de Mediana Edad , Anciano , Procedimientos Quirúrgicos Robotizados/economía , Procedimientos Quirúrgicos Robotizados/efectos adversos , Tiempo de Internación/economía , Tiempo de Internación/estadística & datos numéricos , Cirugía Asistida por Computador/economía , Adulto
3.
J Arthroplasty ; 39(6): 1512-1517, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38103801

RESUMEN

BACKGROUND: The use of technology allows increased precision in component positioning in total knee arthroplasty (TKA). The objectives of this study were to compare (1) perioperative complications and (2) resource utilization between robotic-assisted (RA) and computer-navigated (CN) versus conventional (CI) TKA. METHODS: A retrospective cohort study was performed using a national database to identify patients undergoing unilateral, primary elective TKA from January 2016 to December 2019. A total of 2,174,685 patients were identified and included RA (69,445), CN (112,225), or CI (1,993,015) TKA. Demographics, complications, lengths of stay, dispositions, and costs were compared between the cohorts. Binary logistic regression analysis was performed. RESULTS: The RA TKA cohort had lower rates of intraoperative fracture (0.05 versus 0.08%, P < .05), respiratory complications (0.6 versus 1.1%, P < .05), renal failure (1.3 versus 1.7%, P < .05), delirium (0.1 versus 0.2%, P < .05), gastrointestinal complications (0.04 versus 0.09%, P < .05), postoperative anemia (8.9 versus 13.9%, P < .05), blood transfusion (0.4 versus 0.9%, P < .05), pulmonary embolism, and deep vein thrombosis (0.1 versus 0.2%, P < .05), and mortality (0.01 versus 0.02%, P < .05) compared to conventional TKA, though the cohort did have higher rates of myocardial infarction (0.09 versus 0.07%, P < .05). The CN cohort had lower rates of myocardial infarction (0.02 versus 0.07%, P < .05), respiratory complications (0.8 versus 1.1%, P < .05), renal failure (1.5 versus 1.7%, P < .05), blood transfusion (0.8 versus 0.9%, P < .05), pulmonary embolism (0.08 versus 0.2%, P < .05), and deep vein thrombosis (0.2 versus 0.2%, P < .05) over CI TKA. Total cost was increased in RA (16,190 versus $15,133, P < .05) and CN (17,448 versus $15,133, P < .05). However, the length of hospital stay was decreased in both RA (1.8 versus 2.2 days, P < .05) and CN (2.1 versus 2.2 days, P < .05). CONCLUSIONS: Technology-assisted TKA was associated with lower perioperative complication rates and faster recovery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Tiempo de Internación , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Estudios Retrospectivos , Tiempo de Internación/estadística & datos numéricos , Anciano , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Robotizados/efectos adversos , Cirugía Asistida por Computador
4.
Med Biol Eng Comput ; 58(10): 2387-2396, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32725540

RESUMEN

Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implants. This study compared four techniques to measure 3D pelvic rotations in LD position using computer models. CT scans of 19 subjects in LD position were used to create 3D pelvis models. Pelvic rotations were measured by three users using four techniques: landmark (LM), defined plane (DP), anterior pelvic plane (APP), and plane of best symmetry (POBS) methods. Measurements were analysed for intra-user reliability and relationships between methods were assessed using intraclass correlation coefficient, standard error of measurement, and coefficient of determination. The POBS method exhibited the highest inter-observer reliability and is recommended as a new measurement technique to measure pelvic rotations before THA surgery. The LM method exhibited low reliability but may be suitable for expert users familiar with pelvic landmarks. The APP method should only be used when the patients' APP planes are known in neutral standing and side-lying postures. The DP method is not recommended due to substantial individual variability. Graphical abstract.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Pelvis/diagnóstico por imagen , Postura , Cirugía Asistida por Computador/métodos , Acetábulo/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
6.
Am J Orthop (Belle Mead NJ) ; 44(3): 135-9, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25750948

RESUMEN

Discoid lateral menisci represent a range of morphologic abnormalities of the lateral meniscus. The Wrisberg-variant discoid lateral meniscus is an unstable type that lacks posterior ligament attachments, resulting in "snapping knee syndrome." Abnormally mobile discoid lateral menisci are difficult to diagnose both clinically and with traditional static imaging, such as magnetic resonance imaging. In this article, we discuss the pathophysiology, clinical features, imaging findings, and treatment options for Wrisberg-variant discoid lateral menisci. We focus on the role of dynamic ultrasonography in revealing lateral meniscal subluxation during provocative maneuvers.


Asunto(s)
Enfermedades de los Cartílagos/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Meniscos Tibiales/diagnóstico por imagen , Enfermedades de los Cartílagos/patología , Humanos , Articulación de la Rodilla/patología , Meniscos Tibiales/patología , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA