Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros











Intervalo de año de publicación
1.
JSES Rev Rep Tech ; 3(2): 209-214, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37588431

RESUMEN

Background: Severe humeral bone loss in the setting of failed total elbow arthroplasty (TEA) poses a particularly challenging reconstructive problem. The objective of this study was to review the rationale, indications, contraindications, and detailed surgical technique for using an extended anterior deltopectoral approach to perform a revision TEA when substantially long allografts are required in the presence of severely compromised proximal humerus bone stock. Methods: The authors developed this exposure and reconstructive strategy for failed elbow arthroplasties where the remaining segment of proximal humerus is extremely short, which makes adequate plate fixation of an allograft-prosthetic composite (APC) to the native bone extremely challenging. From an anterior deltopectoral approach, it is possible to use dedicated long, precontoured proximal humerus locking plates to maximize fixation in any remaining proximal humerus. This exposure still makes it possible to provide adequate access to the coupling mechanism of the humeral and ulnar components for implantation of a linked elbow arthroplasty. This exposure also allows for adequate judgment of humeral length and rotation. Pitfalls and Challenges: Crucial steps in the surgery include extending the dissection past the elbow flexion crease such that one can obtain circumferential exposure of the distal humerus. It is also important to couple the humeral and ulnar components prior to committing to the length of the APC. Special attention must be paid to gauge appropriate APC rotation and length for proper soft tissue tension. When performing fixation of the proximal humeral plate, screw purchase must be maximized in both the remaining native proximal humerus and the APC. Compression across the allograft-host interface is paramount for healing to occur. Conclusion: An extended anterior deltopectoral approach to perform a revision TEA when very long APCs are required is a viable option to restore humeral bone stock and regain humeral stem fixation in the setting of failed TEA with extensive humeral bone loss.

2.
J Shoulder Elbow Surg ; 32(6): e311-e318, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36567013

RESUMEN

BACKGROUND: The objective of this study was to retrospectively review clinical and radiographic outcomes of patients who underwent corrective osteotomies for clavicle malunion and internal fixation for nonunion using a combination of virtual surgical planning, patient-specific 3-dimensional (3D)-printed clavicles, and 3D-printed cutting guides manufactured at the point of care. METHODS: Between 2015 and 2021, 18 patients underwent corrective osteotomy for a clavicle malunion (7 shoulders) or internal fixation for a clavicle nonunion (11 shoulders). There were 11 male and 7 female individuals with an average patient age of 43.9 (range 19-76) years. All patients underwent computed tomography evaluation of both clavicles. The DICOM files were manually segmented, virtual surgical planning was performed selectively using commercially available software, and a mirrored version of the normal clavicle was 3D printed along with a 3D-printed replica of the affected clavicle. Three-dimensionally printed mirrored clavicles were used in all cases to ensure adequate restoration of the shape and length of the clavicle and to precontour fixation plates. Virtual surgical planning and 3D-printed cutting guides for osteotomy were used in 4 of 18 (22%) patients. Either cancellous or structural intercalary bone grafting was used in 15 of 18 (83%) cases. Patients were contacted postoperatively to determine clinical outcome scores. Preoperative, early postoperative, and late postoperative radiographs were reviewed to assess for union and complications. The average follow-up time was 24.9 months. RESULTS: Radiographic evaluation at the most recent follow-up demonstrated adequate restoration of length and successful union for all shoulders. There were no complications or reoperations. Postoperative patient-reported outcomes could be obtained in 16 of 18 (88.9%) patients. At the most recent follow-up, the mean visual analog scale for pain was 2.38 points (range, 1-7), the mean shoulder American Shoulder and Elbow Surgeons score was 73.2 points (range, 25-100), and the mean Patient-Reported Outcome Measurement Information System Upper Extremity score was 26 points (range, 7-35). All (100%) the patients were satisfied with their outcome (9 very satisfied, 7 satisfied), and their mean subjective shoulder value was 73% (range, 10%-100%). However, 2 patients complained of hardware-related symptoms, and 1 patient had return of preoperative symptoms after an interim 2 years of pain relief. CONCLUSION: The use of mirrored 3D-printed clavicles combined with virtual surgical planning and patient-specific 3D guides provides a reliable technique for restoring native anatomy when performing corrective osteotomies for clavicle malunion or internal fixation for clavicle nonunion, with a high rate of satisfactory clinical and radiographic outcomes.


Asunto(s)
Clavícula , Fracturas Mal Unidas , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Clavícula/diagnóstico por imagen , Clavícula/cirugía , Fracturas Mal Unidas/diagnóstico por imagen , Fracturas Mal Unidas/cirugía , Estudios Retrospectivos , Osteotomía/métodos , Dolor , Resultado del Tratamiento
3.
JSES Int ; 6(4): 690-695, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35813147

RESUMEN

Background: Aseptic loosening, polyethylene wear, and mechanical failure have limited the use of total elbow arthroplasty (TEA) in physically demanding patients. Newer implant designs have been introduced to improve mechanical performance. The purpose of this study was to report the results obtained after implantation of the Nexel TEA. Methods: Over a 3-year period, 2 surgeons implanted a total of 35 consecutive Nexel primary TEAs. The average patient age was 65 years, and standard TEA indications were utilized. Elbows were evaluated for pain, motion, the Mayo Elbow Performance Score, complications, and reoperations. Results: Twelve elbows underwent a revision surgery with removal of either a part of or all Nexel components at an average of 2.2 years. All revision surgeries performed at our institution revealed gross loosening of the component(s). Metallic debris and periprosthetic fractures were present in 45% and 50% of cases, respectively. Radiographic evaluation of existing components revealed humeral component loosening and periprosthetic fractures in 2 and 4 elbows, respectively. Overall, 17 of 35 (50%) elbows underwent reoperation, and 20 of 35 (60%) elbows sustained at least 1 postoperative complication. Conclusion: Primary TEA with implantation of this implant was associated with an unacceptably high rate of early implant loosening, periprosthetic fracture, and reoperation. We hypothesize that this early unexpected mechanical failure could be explained by both the utilization of a titanium-on-polyethylene bearing surface and a more posterior center of rotation causing premature anterior impingement with flexion leading to failure of the bonding interface, secondary titanium particle shedding, polyethylene wear, and osteolysis.

4.
JSES Rev Rep Tech ; 2(4): 464-468, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37588470

RESUMEN

Background: Venous thromboembolic events (VTEs) following orthopedic surgery may lead to serious morbidity and mortality. Fortunately, VTEs following upper extremity procedures are uncommon. However, the true incidence is likely underreported. The aim of this study is to provide a systematic review, excluding large database studies, to report on the incidence of VTEs following shoulder arthroscopic procedures. Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, a systematic review of multiple databases was performed. A comprehensive search of several databases from inception to September 1, 2021, limited to English language and excluding animal studies, was designed and conducted. Studies were screened by 2 independent reviewers. A decision to exclude studies from large surgical or insurance claim databases was made to minimize the risk of including overlapping data points in this systematic review. Results: Thirteen studies met inclusion and exclusion criteria and form part of this systematic review. A total of 32,407 patients were included in this study. Among these patients, the deep vein thrombosis, pulmonary embolism, and overall VTE rates were 0.15%, 0.08%, and 0.21%, respectively. Among the patients specified to have undergone arthroscopic rotator cuff repair, the rate of deep vein thrombosis, pulmonary embolism, and overall VTE was 0.71%, 0.37%, and 1.04%, respectively. Conclusion: While symptomatic VTEs are rare following shoulder arthroscopic procedures, surgeons must be aware that they still account for a certain number of postoperative complications. Factors such as operative time, open procedures, obesity, and altitude may increase the risk of postoperative VTE although conflicting data exist. Current literature supports the idea that chemical antithrombotic prophylaxis likely provides no significant advantage over early mobilization in reducing VTEs following shoulder arthroscopy in low-risk patients.

6.
Ann Biomed Eng ; 49(5): 1333-1341, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33145676

RESUMEN

Cigarette smoking is the largest cause of preventable deaths, and a known risk factor for musculoskeletal issues including rotator cuff tendon tears. Tendon degeneration is believed to be due in part to changes in tendon cell health and collagen structure. Several studies have demonstrated that exposure to nicotine negatively impacts tendon healing, but surprisingly, nicotine exposure was shown to increase rat supraspinatus tendon stiffness. In order to address this seeming contradiction, the objective of this study was to comprehensively investigate the effects of long-term (18 weeks) exposure of nicotine on tendon-to-bone microstructural properties in a rat model. We hypothesized that long term subcutaneous nicotine delivery would lead to diminished tendon mechanical properties, decreased bone microstructure in the humeral head, and altered tendon cell morphology compared to age-matched control rats receiving saline. Results demonstrated a small decrease in tendon size and stiffness, with decreased cell density in the tendon midsubstance. However, no differences were found in the enthesis fibrocartilage or in the underlying subchondral or trabecular bone. In conclusion, our study revealed limited effects of nicotine on the homeostatic condition of the supraspinatus tendon, enthesis, and underlying bone. Future studies are needed to ascertain effects of other components of tobacco products.


Asunto(s)
Húmero/efectos de los fármacos , Nicotina/toxicidad , Manguito de los Rotadores/efectos de los fármacos , Animales , Húmero/anatomía & histología , Húmero/diagnóstico por imagen , Húmero/fisiología , Masculino , Ratas Sprague-Dawley , Manguito de los Rotadores/anatomía & histología , Manguito de los Rotadores/diagnóstico por imagen , Microtomografía por Rayos X
7.
J Hand Surg Glob Online ; 2(4): 246-249, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32322804

RESUMEN

The American Society for Surgery of the Hand (ASSH) was established in 1946. Since then, important advances have been made in the diagnosis and treatment of conditions affecting the upper extremity. However, there has been little documentation regarding how the largest and oldest society dedicated to hand surgery has evolved over time. Furthermore, an understanding of the history of the ASSH and the specialty of hand surgery should be emphasized in resident and fellow education. The authors aim to provide a historical overview of the ASSH through the speeches of ASSH past presidents that sheds light on future directions and long-term goals. Presidential addresses from 1961 to 2018 (courtesy of ASSH Chase Library historical archives) were reviewed. The overall percentage of ASSH presidents by specialty was 67% orthopedic, 25% plastic surgery, and 8% general surgery. The most common speech theme overall was how to be a good hand surgeon (31%). The most common speech themes were, by decade: the 1960s, history and the current state of ASSH; the 1970s and 1980s, assessments of how to be a good surgeon and goals for ASSH; the 1990s, health care and governmental regulation; the 2000s, how to be a better hand surgeon; and the 2010s goals for ASSH. In earlier years, there was more of a focus on education and technical skill development in the ASSH. Work-life balance, introduced in the 1990s, has become more of a focus in the past 20 years. Revisiting the history of the ASSH and its goals allows us to reflect on progress made while recognizing what is important as we look into the future. Furthermore, as we strive to make progress in the field of hand surgery during the current pandemic, valuable tools surface that will allow the specialty to strengthen its education, research, and patient care delivery in the future.

8.
J Hand Surg Glob Online ; 2(3): 117-120, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-35415490

RESUMEN

Purpose: Fireworks may result in a wide spectrum of injury to the upper extremity ranging from mild burns to amputation. In this cross-sectional study, we describe the epidemiology of upper-extremity injuries in the United States associated with fireworks using the Consumer Product Safety Commission's National Electronic Injury Surveillance System (NEISS). Methods: The NEISS database was queried between 2011 and 2017 for all injuries of the upper extremity (from shoulder to fingertip) associated with fireworks. There were 806 unique cases, yielding a total weighted estimate of 31,430 national cases presenting to emergency departments in the United States during this time frame. National estimates, standard errors, and 95% confidence intervals were calculated using parameters provided by the NEISS database. Significance of trends was determined using adjusted Wald tests, for which P values less than .05 were considered significant. Results: The weighted estimate was 4,490 yearly cases from 2011 until 2017. Trend analysis did not show a significant change in the number of yearly cases during that time frame. Most injuries (62%) occurred around June 27 until July 11. Nearly 50% of those injured were aged 10 to 29 years and were male. Fireworks with low pyrotechnic content such as sparklers, snakes, and poppers resulted in 26% of injuries. Although 83% of patients were treated and released from the emergency department, other injuries were more severe, with a 4.5% rate of amputation, 7% rate of hospital admission, and 8% rate of transfer to another hospital. Conclusions: Fireworks injuries to the hand and upper extremity continue to represent a serious burden of disease to the United States population and the health care system. Increased awareness, legislation, and targeted public education about the dangers of fireworks should be considered ways to reduce the incidence of these injuries. Type of study/level of evidence: Prognostic III.

9.
J Hand Surg Eur Vol ; 44(5): 510-516, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30871405

RESUMEN

The purpose of this study was to systematically quantify distal radioulnar joint stability with a cadaveric model, using radiographic and joint contact force measurements. Six fresh-frozen cadavers underwent sequential ulnar styloid osteotomies. Posteroanterior and lateral stress radiographs were obtained and joint contact forces and areas were measured. Posteroanterior radiographs showed a significant increase in the distal radioulnar joint gap after osteotomy of the base of the ulnar styloid. Contact force and contact area measurements were not significantly different. We conclude that fractures that involve the ulnar styloid base should be considered for operative fixation when carrying out open reduction and internal fixation of fractures of the distal radius.


Asunto(s)
Osteotomía , Cúbito/cirugía , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos/fisiología , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronación/fisiología , Rotación , Supinación/fisiología
10.
J Orthop Res ; 37(1): 94-103, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30345583

RESUMEN

Nicotine is harmful to many bodily systems; however, the effects of nicotine on intra-substance tendon healing remain largely unexplored. The purpose of this study was to examine the functional, structural, and biomechanical effects of nicotine on the healing of Achilles tendons in rats after an acute full-thickness injury. Sixty Sprague-Dawley rats were enrolled in this study. Half were exposed to 0.9% saline and half to 61 ng/mL of nicotine for 3 months via subcutaneous osmotic pumps. At 3 months, all rats underwent blunt full thickness transection of the left Achilles tendon and were immobilized for one week in plantarflexion. In-vivo assays were conducted prior to injury, at 21 days, and at 42 days post-injury and included the following: Functional limb assessment, passive joint mechanics, and vascular evaluation. Rats were sacrificed at 21 and 42 days for biomechanical testing and histologic evaluation. Rats exposed to nicotine demonstrated decreased vascularity, greater alteration in gait mechanics, and increased passive ROM of the ankle joint. Biomechanically, the nicotine tendons failed at lower maximum loads, were less stiff, had smaller cross-sectional areas and had altered viscoelastic properties. Histologically, nicotine tendons demonstrated decreased vessel density at the injury site. This study demonstrates that nicotine leads to worse functional outcomes and biomechanical properties in tendons. The decreased vascularity in the nicotine group may suggest an underlying mechanism for inferior tendon healing. Patients should be counseled that using nicotine products increase their risk of poor tendon healing and may predispose them to tendon re-rupture. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Asunto(s)
Tendón Calcáneo/efectos de los fármacos , Estimulantes Ganglionares/efectos adversos , Nicotina/efectos adversos , Regeneración/efectos de los fármacos , Traumatismos de los Tendones , Tendón Calcáneo/lesiones , Tendón Calcáneo/patología , Animales , Masculino , Ratas Sprague-Dawley
11.
J Hand Surg Am ; 43(12): 1092-1097, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29908930

RESUMEN

PURPOSE: Reformatting computed tomography (CT) scans along the scaphoid longitudinal axis improves the ability to detect scaphoid fractures compared with reformats along the wrist axis. However, it remains unclear whether scaphoid axis reformats affect measurements of displacement or deformity, which are factors that drive the clinical decision to perform open reduction internal fixation. Our null hypothesis was that reformatting CT scans along the scaphoid axis does not affect measurements of fracture displacement and deformity. METHODS: Thirty patients with CT scans demonstrating scaphoid fractures (4 proximal pole, 17 midwaist fractures, and 9 distal) were identified and reformatted along 2 axes: the longitudinal axis of the scaphoid and the longitudinal axis of the wrist. The reformatted scans were sent to 2 musculoskeletal radiologists and 2 orthopedic hand surgeons who made the following measurements: (1) fracture gap, (2) displacement of the articular surface, (3) intrascaphoid angle, and (4) height to length (H:L) ratio. RESULTS: The reliability of each of the measurements cited above was compared for all raters between the 2 axes using intraclass correlation coefficients. Measurement of fracture gap and articular displacement trended toward more reliability in the wrist axis, whereas measurement of H:L ratio and intrascaphoid angle trended toward more reliability in the scaphoid axis. However, no differences in measurements between the 2 axes were statistically significant. CONCLUSIONS: This study demonstrates that reformatting CT scans in line with the axis of the scaphoid does not result in more reliable measurements of displacement or deformity. CLINICAL RELEVANCE: Measurements of displacement and deformity in scaphoid fractures can be made in the wrist axis with comparative reliability to those in the longitudinal scaphoid axis.


Asunto(s)
Fracturas Óseas/diagnóstico por imagen , Hueso Escafoides/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA