Phys Med Biol ; 69(13)2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38843812

RESUMEN

Objective. In current clinical practice for quality assurance (QA), intensity modulated proton therapy (IMPT) fields are verified by measuring planar dose distributions at one or a few selected depths in a phantom. A QA device that measures full 3D dose distributions at high spatiotemporal resolution would be highly beneficial for existing as well as emerging proton therapy techniques such as FLASH radiotherapy. Our objective is to demonstrate feasibility of 3D dose measurement for IMPT fields using a dedicated multi-layer strip ionization chamber (MLSIC) device.Approach.Our developed MLSIC comprises a total of 66 layers of strip ion chamber (IC) plates arranged, alternatively, in thexandydirection. The first two layers each has 128 channels in 2 mm spacing, and the following 64 layers each has 32/33 IC strips in 8 mm spacing which are interconnected every eight channels. A total of 768-channel IC signals are integrated and sampled at a speed of 6 kfps. The MLSIC has a total of 19.2 cm water equivalent thickness and is capable of measurement over a 25 × 25 cm2field size. A reconstruction algorithm is developed to reconstruct 3D dose distribution for each spot at all depths by considering a double-Gaussian-Cauchy-Lorentz model. The 3D dose distribution of each beam is obtained by summing all spots. The performance of our MLSIC is evaluated for a clinical pencil beam scanning (PBS) plan.Main results.The dose distributions for each proton spot can be successfully reconstructed from the ionization current measurement of the strip ICs at different depths, which can be further summed up to a 3D dose distribution for the beam. 3D Gamma Index analysis indicates acceptable agreement between the measured and expected dose distributions from simulation, Zebra and MatriXX.Significance.The dedicated MLSIC is the first pseudo-3D QA device that can measure 3D dose distribution in PBS proton fields spot-by-spot.


Asunto(s)
Terapia de Protones , Radiometría , Radiometría/instrumentación , Terapia de Protones/instrumentación , Dosis de Radiación , Dosificación Radioterapéutica , Protones , Fantasmas de Imagen , Humanos , Radioterapia de Intensidad Modulada/instrumentación
2.
Med Phys ; 51(4): 2967-2974, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38456557

RESUMEN

BACKGROUND: Position verification and motion monitoring are critical for safe and precise radiotherapy (RT). Existing approaches to these tasks based on visible light or x-ray are suboptimal either because they cannot penetrate obstructions to the patient's skin or introduce additional radiation exposure. The low-cost mmWave radar is an ideal solution for these tasks as it can monitor patient position and motion continuously throughout the treatment delivery. PURPOSE: To develop and validate frequency-modulated continuous wave (FMCW) mmWave radars for position verification and motion tracking during RT delivery. METHODS: A 77 GHz FMCW mmWave module was used in this study. Chirp Z Transform-based (CZT) algorithm was developed to process the intermediate frequency (IF) signals. Absolute distances to flat Solid Water slabs and human shape phantoms were measured. The accuracy of absolute distance and relative displacement were evaluated. RESULTS: Without obstruction, mmWave based on the CZT algorithm was able to detect absolute distance within 1 mm for a Solid Water slab that simulated the reflectivity of the human body. Through obstructive materials, the mmWave device was able to detect absolute distance within 5 mm in the worst case and within 3.5 mm in most cases. The CZT algorithm significantly improved the accuracy of absolute distance measurement compared with Fast Fourier Transform (FFT) algorithm and was able to achieve submillimeter displacement accuracy with and without obstructions. The surface-to-skin distance (SSD) measurement accuracy was within 8 mm in the anterior of the phantom. CONCLUSIONS: With the CZT signal processing algorithm, the mmWave radar is able to measure the absolute distance to a flat surface within 1 mm. But the absolute distance measurement to a human shape phantom is as large as 8 mm at some angles. Further improvement is necessary to improve the accuracy of SSD measurement to uneven surfaces by the mmWave radar.


Asunto(s)
Procesamiento de Señales Asistido por Computador , Agua , Humanos , Movimiento (Física) , Radiografía
3.
Sci Rep ; 13(1): 20181, 2023 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-37978269

RESUMEN

Ultra-high dose rate (UHDR) radiotherapy (RT) or FLASH-RT can potentially reduce normal tissue toxicity. A small animal irradiator that can deliver FLASH-RT treatments similar to clinical RT treatments is needed for pre-clinical studies of FLASH-RT. We designed and simulated a novel small animal FLASH irradiator (SAFI) based on distributed x-ray source technology. The SAFI system comprises a distributed x-ray source with 51 focal spots equally distributed on a 20 cm diameter ring, which are used for both FLASH-RT and onboard micro-CT imaging. Monte Carlo simulation was performed to estimate the dosimetric characteristics of the SAFI treatment beams. The maximum dose rate, which is limited by the power density of the tungsten target, was estimated based on finite-element analysis (FEA). The maximum DC electron beam current density is 2.6 mA/mm2, limited by the tungsten target's linear focal spot power density. At 160 kVp, 51 focal spots, each with a dimension of [Formula: see text] mm2 and 10° anode angle, can produce up to 120 Gy/s maximum DC irradiation at the center of a cylindrical water phantom. We further demonstrate forward and inverse FLASH-RT planning, as well as inverse-geometry micro-CT with circular source array imaging via numerical simulations.


Asunto(s)
Radiometría , Tungsteno , Animales , Rayos X , Dosis de Radiación , Microtomografía por Rayos X , Fantasmas de Imagen , Dosificación Radioterapéutica , Método de Montecarlo
4.
Phys Med Biol ; 67(17)2022 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-35905730

RESUMEN

Objective. Proton pencil beam scanning (PBS) treatment fields needs to be verified before treatment deliveries to ensure patient safety. In current practice, treatment beam quality assurance (QA) is measured at a few selected depths using film or a 2D detector array, which is insensitive and time-consuming. A QA device that can measure all key dosimetric characteristics of treatment beams spot-by-spot within a single beam delivery is highly desired.Approach. We developed a multi-layer strip ionization chamber (MLSIC) prototype device that comprises of two layers of strip ionization chambers (IC) plates for spot position measurement and 64 layers of plate IC for beam energy measurement. The 768-channel strip ion chamber signals are integrated and sampled at a speed of 3.125 kHz. It has a 25.6 cm × 25.6 cm maximum measurement field size and 2 mm spatial resolution for spot position measurement. The depth resolution and maximum depth were 2.91 mm and 18.6 cm for 1.6 mm thick IC plate, respectively. The relative weight of each spot was determined from total charge by all IC detector channels.Main results. The MLSIC is able to measure ionization currents spot-by-spot. The depth dose measurement has a good agreement with the ground truth measured using a water tank and commercial one-dimensional (1D) multi-layer plate chamber. It can verify the spot position, energy, and relative weight of clinical PBS beams and compared with the treatment plans.Significance. The MLSIC is a highly efficient QA device that can measure the key dosimetric characteristics of proton treatment beams spot-by-spot with a single beam delivery. It may improve the quality and efficiency of clinical proton treatments.


Asunto(s)
Terapia de Protones , Radiactividad , Humanos , Fantasmas de Imagen , Terapia de Protones/métodos , Protones , Radiometría , Dosificación Radioterapéutica
5.
J Org Chem ; 85(2): 994-1000, 2020 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-31850754

RESUMEN

Relebactam, a potent ß-lactamase inhibitor, in combination with Primaxin is an FDA-approved (Recarbrio) treatment for serious and antibiotic-resistant bacterial infections. An efficient synthesis of key chiral piperidine intermediate 1 suitable for large-scale preparation of relebactam is described. The key steps include a unique highly diastereoselective FeCl3·6H2O/NaBH4 reduction of a chiral oxime ether and chemoselective amidation of the resulting unprotected pipecolic acid. Nuclear magnetic resonance studies and density functional theory calculations were carried out on the substrate-Fe(III) complexes, which shed light on diastereoselective reduction.


Asunto(s)
Compuestos de Azabiciclo/síntesis química , Compuestos de Azabiciclo/farmacología , Borohidruros/química , Cloruros/química , Compuestos Férricos/química , Oximas/química , Inhibidores de beta-Lactamasas/síntesis química , Inhibidores de beta-Lactamasas/farmacología , Compuestos de Azabiciclo/química , Éteres/química , Estructura Molecular , Oxidación-Reducción , Análisis Espectral/métodos , Estereoisomerismo , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA