Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Life (Basel) ; 13(8)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37629610

RESUMEN

INTRODUCTION: In some cases, there may be a discrepancy between the symptomatology alleged by Crohn's disease (CD) patients and the results of laboratory tests or imaging investigations. Ileocolonoscopy with biopsy is the primary investigation for diagnosing and monitoring CD patients. Cross-sectional imaging techniques such as CT or MR enterography (MRE) and intestinal ultrasonography (IUS) have been proposed as complementary methods to colonoscopy for a complete evaluation of this category of patients. This study aims to identify the role of IUS, contrast-enhanced ultrasound (CEUS) and MRE in evaluating ileal CD activity, using clinical severity scores (Crohn's disease activity index-CDAI, Harvey-Bradshaw index-HBI) and faecal calprotectin or C-reactive protein (CRP) levels as reference methods. MATERIALS AND METHODS: A total of 44 adult patients with ileal CD confirmed using an ileocolonoscopy with biopsy and histopathological examination were assessed by IUS, CEUS and MRE. The evaluation of the disease activity based on the results obtained from the cross-sectional imaging tests was carried out by using some severity scores available in the literature. The sensitivity and specificity of IUS + CEUS and MRE for differentiating active from inactive forms of CD were determined using CDAI, HBI, faecal calprotectin and CRP as reference methods. The accuracy of the results was assessed by the receiver operating characteristics method. The Pearson correlation coefficient was used to determine the types of correlation. A p-value less than 0.05 suggested a statistically significant relationship. RESULTS: Compared to CDAI, the best correlation was identified for Limberg score (r = 0.667, 95% confidence interval (CI) [0.46, 0.8], p < 0.001), followed by MaRIAs score (r = 0.614, 95% CI [0.39, 0.77], p < 0.001). A sensitivity of 93.33% and a specificity of 71.43% (AUC = 0.98) were demonstrated in the case of Limberg score for differentiating patients with active disease from those in remission and for MaRIAs score a sensitivity of 100.00% and a specificity of 57.14% (AUC = 0.97). Regarding HBI, the best correlation was observed for MaRIAs score (r = 0.594, 95% CI [0.36, 0.76], p < 0.001). Also, faecal calprotectin showed the best correlation with MaRIAs score (r = 0.697, 95% CI [0.46, 0.84], p < 0.001), but in the case of CRP, there was only a weak correlation for all evaluated scores. CONCLUSIONS: Although magnetic resonance imaging does not appear to be superior to ultrasonography in terms of accuracy for differentiating active forms of CD from those in remission, the results of our study suggest that MRE associates a better correlation with clinical severity scores and faecal calprotectin levels compared to ultrasonography. More studies are needed to validate these results.

2.
Diagnostics (Basel) ; 13(3)2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36766671

RESUMEN

The diagnosis of inflammatory bowel disease (IBD) can sometimes be challenging. By corroborating clinical, imaging and histological data, the two main entities of IBD, ulcerative colitis and Crohn's disease (CD), can be differentiated in most cases. However, there remains 10-20% of patients where the diagnosis cannot be accurately established, in which case the term "IBD unclassified" is used. The imaging techniques most used to evaluate patients with IBD include colonoscopy, ultrasonography and magnetic resonance imaging. Endoscopic ultrasonography is mainly recommended for the evaluation of perianal CD. Through this work, we aim to identify other uses of this method in the case of patients with IBD.

3.
Rom J Morphol Embryol ; 64(4): 595-601, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38184841

RESUMEN

BACKGROUND: Gastrointestinal stromal tumors (GISTs) are rare mesenchymal tumors, mostly located within the stomach. About 30% of GISTs are incidentally diagnosed and as they become symptomatic may be associated with bleeding, bowel obstruction or spontaneous rupture. CASE PRESENTATION: We present the case of a middle-aged patient diagnosed with a giant gastric GIST, which presented for intermittent gastric outlet obstruction symptoms, and emphasize the major imagistic, histopathological, and therapeutic challenges that may be encountered. There are only several cases of gastric exophytic gastric GIST provoking intermittent gastric outlet obstruction. Tumor resection should be adapted to every patient's status, focused on en bloc extraction, with preservation of invaded organs as much as possible.


Asunto(s)
Obstrucción de la Salida Gástrica , Tumores del Estroma Gastrointestinal , Obstrucción Intestinal , Neoplasias Gástricas , Persona de Mediana Edad , Humanos , Tumores del Estroma Gastrointestinal/complicaciones , Obstrucción de la Salida Gástrica/etiología , Rotura Espontánea , Neoplasias Gástricas/complicaciones
4.
J Clin Ultrasound ; 50(6): 844-849, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35254661

RESUMEN

INTRODUCTION: Pancreatic malignancies represent highly fatal diseases with poor prognosis and constantly increasing incidence despite modern diagnostic and therapeutic options. Both endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) are regarded as mainstays in pancreatic cancer management. The present study aims to evaluate whether accuracy EUS with fine-needle aspiration or biopsy (FNA or FNB) in pancreatic cancer diagnosis is influenced by prior biliary stenting or by technical or anatomical features (stent type, number of needle passes, common bile duct or Wirsung's diameter, topographical characteristics and diameter of the pancreatic tumor). MATERIALS AND METHODS: This retrospective study includes 243 patients with pancreatic cancer who underwent ERCP and EUS with fine-needle aspiration or biopsy (FNA or FNB). RESULTS AND DISCUSSION: Out of the total number of patients, 68 were stented prior to EUS. We found that the EUS-FNA diagnostic yield is not influenced either by the presence of biliary stent, nor by the type of stent (plastic or metallic). Moreover, the mean needle passes required were similar for both stented patients and not stented ones. CONCLUSIONS: Ultimately, given our results, we can state that EUS-FNA/FNB can be safely and accurately performed in the presence of biliary stents.


Asunto(s)
Neoplasias Pancreáticas , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Endosonografía , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Estudios Retrospectivos , Neoplasias Pancreáticas
5.
Rom J Morphol Embryol ; 62(3): 723-731, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35263400

RESUMEN

OBJECTIVE: The purpose of this study was to present the experience of a single center on endoscopic ultrasound-fine-needle biopsy (EUS-FNB) of pancreatic solid tumors amenable to immunohistochemistry (IHC) assay. PATIENTS, MATERIALS AND METHODS: Inclusion criterion for this prospective study was identifying patients with pancreatic solid tumors, by means of imaging methods, from January 2018 to February 2020, within the Department of Gastroenterology, Emergency Clinical Hospital, Bucharest, Romania. All patients underwent EUS-FNB and the harvested tissue was sent to the Department of Pathology for histopathological (HP) diagnosis and IHC assessment if tumoral origin remained undetermined. RESULTS: A total of 57 patients were ultimately selected to take part in our study. We performed immunohistochemical analysis based on the morphological diagnosis of the pancreatic tumors and assessed cytokeratin (CK)7, CK20, caudal type homeobox 2 (CDX2), MutL homolog 1 (MLH1), MutS homolog (MSH)2, MSH6, postmeiotic segregation 2 (PMS2) for all histopathologically uncertain pancreatic ductal adenocarcinoma (PDAC) and chromogranin A, synaptophysin, pan-CK AE1∕AE3 for pancreatic neuroendocrine tumors (pNETs). Cox hazard regression was performed to identify the factors influencing the survival rate. In univariate analysis, patient survival time was significantly associated with stage, location, surgical management and CK7 positivity. Our data show a statistically significant predictive relationship between stage (regional or metastatic) and hazard for survival (p=0.015). Tumoral location in the tail (p=0.015) and radicality surgery (p=0.015) significantly decrease the survival of pancreatic cancer (PAC) patients. The presence of CK7 (p=0.015) significantly increases the survival of pancreas cancer patients. CONCLUSIONS: EUS-FNB has opened up a new path for pancreatic tumor diagnosis providing enough tissue for HP examination and IHC. A panel of several immunomarkers might aid in providing new therapies for PAC patients.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Carcinoma Ductal Pancreático/patología , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Humanos , Páncreas/patología , Neoplasias Pancreáticas/patología , Estudios Prospectivos , Estudios Retrospectivos
6.
Curr Health Sci J ; 46(4): 323-328, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33717505

RESUMEN

Despite progresses made in oncology, pancreatic adenocarcinoma has a grim prognosis and commonly presents with rapidly advancing jaundice which requires endoscopic treatment. AIM: Our objective was to show the perspective of a high ERCP volume dedicated Center on endoscopic stenting for malignant biliary obstruction consecutive to pancreatic cancer. METHODS: We conducted a retrospective study, between October 2017 and October 2020, and enrolled hospitalized patients within the Gastroenterology Department of the Clinical Emergency Hospital Bucharest, diagnosed with pancreatic cancer with secondary malignant biliary obstruction which underwent ERCP stenting. RESULTS: We identified 269 patients which were admitted in our Clinic with a pancreatic lesion on computed tomography or magnetic resonance imaging and underwent EUS-FNA. 115 patients with proven pancreatic malignancy were selected and underwent ERCP stenting. 69 received plastic stents and 46 metal biliary stents, with the stent chosen based on patient's characteristics and availability at the time of the procedure. Per total 234 stents were used for relief of the cholestasis syndrome. The number of ERCP procedures was higher in the plastic stents group with a median of 1,8 whereas the SEMS had 1,5 range of procedures. Procedures were successful in 54 patients following plastic stents and 33 that underwent SEMS. At 30 days, overall mortality rate was of 5%. CONCLUSIONS: Malignant obstruction secondary to pancreatic cancer is amenable by ERCP. However, choosing the right stents still varies. SEMS seem to be more efficient on a long term with fewer complications rates and further studies should be performed.

7.
Rom J Morphol Embryol ; 60(2): 659-665, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31658341

RESUMEN

Isolated esophageal ulcerations in Crohn's disease pose a great challenge in diagnosing and providing the correct treatment. We present the case of a 23-year-old woman with recurrent episodes of oral aphthosis, dysphagia, odynophagia and heartburn. Upper digestive endoscopy revealed an irregular mucosa with multiple ulcerations with irregular margins within the mid-esophagus. Immunoglobulin G (IgG) for cytomegalovirus and herpes virus were both positive. Four years after, she presented with the same symptoms and the involvement of ileo-colonic lesions, with pathological findings helped establish the Crohn's disease diagnosis. Crohn's disease represents an idiopathic chronic inflammatory gut disease, which can affect any part of the digestive tract. The onset by esophageal disease and no intestinal involvement is rare and challenging for a proper diagnosis.


Asunto(s)
Enfermedad de Crohn/complicaciones , Citomegalovirus/patogenicidad , Enfermedades del Esófago/etiología , Esófago/patología , Herpesvirus Cercopitecino 1/patogenicidad , Úlcera/etiología , Adulto , Enfermedad de Crohn/patología , Femenino , Humanos , Adulto Joven
8.
Rom J Morphol Embryol ; 59(1): 297-302, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29940641

RESUMEN

Cholangiocarcinoma is an extremely rare and highly aggressive primary malignancy of the biliary tract. The current report illustrates a rare case of distal common bile duct adenocarcinoma encountered in a 65-year-old male patient who was thoroughly investigated after presenting with a two weeks history of pain in the right hypochondrium, jaundice and unintentional weight loss (6 kg in two weeks). The medical team opted for a pancreaticoduodenectomy (Whipple procedure) managing to obtain negative resection margins of the tumor with a favorable immediate postoperative evolution. However, the surgical team was forced to reintervene twice due to complications caused mainly by the patient's disregard.


Asunto(s)
Adenocarcinoma/diagnóstico , Neoplasias de los Conductos Biliares/diagnóstico , Adenocarcinoma/patología , Anciano , Neoplasias de los Conductos Biliares/patología , Humanos , Masculino , Enfermedades Raras
10.
Rom J Morphol Embryol ; 57(3): 931-936, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28002507

RESUMEN

Gastric cancer (GC) is an important health problem despite the advances in surgery and chemotherapy and although the incidence is decreasing, GC is still considered the second most common cause of deceases produced by cancer. Survival rates in gastric cancer are low, mainly because most patients are often diagnosed in late stages. The current interest in the diagnostic of GC is the detection of early gastric cancer. Advances in high-resolution endoscopic techniques such as narrow band imaging (NBI) allow the detection of early precancerous lesions like polyps or metaplastic mucosa. Performing only white light imaging endoscopy in order to detect gastric cancer can lead to omission or misdiagnose of a considerable number of early gastric cancers. NBI endoscopy associated with other high-resolution examinations is viable in detecting early gastric cancer, though few studies also indicate that the endoscopist's expertise plays an important factor as well.


Asunto(s)
Endoscopía/métodos , Imagen de Banda Estrecha/métodos , Lesiones Precancerosas/diagnóstico por imagen , Neoplasias Gástricas/diagnóstico por imagen , Tracto Gastrointestinal Superior/diagnóstico por imagen , Detección Precoz del Cáncer , Humanos , Lesiones Precancerosas/patología , Neoplasias Gástricas/mortalidad , Neoplasias Gástricas/patología , Tracto Gastrointestinal Superior/patología
11.
Rom J Morphol Embryol ; 57(3): 1025-1030, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28002519

RESUMEN

PURPOSE: Colorectal carcinoma is an important cause of mortality worldwide. The fact that tumor growth is dependent on angiogenesis has supported researches for new prognostic parameters and the development of novel therapeutic strategies. Accordingly, we sought to evaluate angiogenesis quantitatively by assessing microvessel density in colorectal cancer. MATERIALS AND METHODS: The blood vessels stained with CD31, CD34 and CD105 were counted, and we reported their number per square millimeter in order to obtain microvascular density (MVD). Then, we aimed at comparing the performance of three endothelial cell markers (CD31, CD34, and CD105) on formalin-fixed tissues from 58 patients diagnosed with colorectal cancer. RESULTS: Following the comparison of the average effective vessels marked with the three markers, Student's t-test showed that the mean number of blood vessels marked with CD34 is higher than the blood vessels marked with CD31 and CD105. A significant difference that has been registered between the three levels of the T stage was found in the patients in our study, in terms of value marker CD105, ANOVA p=0.049, which returns to a value <0.05. Quick time decreases the pT stage, the observed differences being close to statistical significance. However, the result of ANOVA test does not allow us to say that differences can be generalized and not just a particular result, valid only for the study group, p=0.061 >0.05. There is a significant difference between patients with stage T, in terms of value: hemoglobin (ANOVA p<0.001), hematocrit (ANOVA p<0.001), mean corpuscular volume (MCV) (ANOVA p<0.001), mean corpuscular hemoglobin (MCH) (ANOVA p=0.002 <0.01 - significant difference with 99% confidence). By calculating the Pearson's correlation coefficient for the relationship CD31-CD105, we obtained a value r=0.440, which corresponds to p=0.0013 <0.05, indicating a statistically noteworthy direct correlation between the two factors. CONCLUSIONS: CD31 marker increases simultaneously with the CD105, in the cases analyzed throughout the present study. The ability of tumors to maintain a high vascular blood density in their inner portions may represent a reliable parameter to evaluate tumor angiogenesis and a finding relevant for future development of therapeutic angiogenesis strategies.


Asunto(s)
Antígenos CD/metabolismo , Neoplasias Colorrectales/genética , Neoplasias Colorrectales/metabolismo , Células Endoteliales/metabolismo , Anciano , Células Endoteliales/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
12.
Rom J Morphol Embryol ; 57(2 Suppl): 619-626, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27833952

RESUMEN

Conventional white light endoscopy is far from being an ideal tool to detect, characterize, and confirm the nature of colorectal lesions in order to indicate targeted biopsies or polyp resections only when necessary. Minimally invasive imaging techniques have gradually emerged to reveal previously unseen abnormalities to the operator during endoscopic examination. In this respect, technology and applications of narrow band imaging (NBI) are rapidly evolving. Magnification using NBI with near-focus mode has been introduced recently to enable closer examination under the control of a single button. The aim of this article is to offer an in-depth overview of this topic with emphasis on colorectal polyps through a literature review by using PubMed search tools including full-text articles, up-to-date guidelines and recent abstracts with obvious conclusions.


Asunto(s)
Pólipos del Colon/diagnóstico , Imagen de Banda Estrecha/métodos , Pólipos del Colon/patología , Colonoscopía , Humanos , Imagen de Banda Estrecha/normas , Fenómenos Ópticos
13.
Rom J Morphol Embryol ; 57(2): 413-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27516013

RESUMEN

UNLABELLED: G-protein coupled estrogen receptor 1 (GPER), a particular extranuclear estrogen receptor (ER), seems not to be significantly involved in normal female phenotype development but especially associated with severe genital malignancies. This study investigated the GPER expression in different types of normal and abnormal proliferative endometrium, and the correlation with the presence of ERα. GPER was much highly expressed in cytoplasm (than onto cell membrane), contrary to ERα, which was almost exclusively located in the nucleus. Both ERs' densities were higher in columnar epithelial then in stromal cells, according with higher estrogen-sensitivity of epithelial cells. GPER and ERα density decreased as follows: complex endometrial hyperplasia (CEH) > simple endometrial hyperplasia (SHE) > normal proliferative endometrium (NPE) > atypical endometrial hyperplasia (AEH), ERα' density being constantly higher. In endometrial adenocarcinomas, both ERs were significant lower expressed, and widely varied, but GPER÷ERα ratio was significantly increased in high-grade lesions. CONCLUSIONS: The nuclear ERα is responsible for the genomic (the most important) mechanism of action of estrogens, involved in cell growth and multiplication. In normal and benign proliferations, ERα expression is increased as an evidence of its effects on cells with conserved architecture, in atypical and especially in malignant cells ERα's (and GPER's) density being much lower. Cytoplasmic GPER probably interfere with different tyrosine÷protein kinases signaling pathways, also involved in cell growth and proliferation. In benign endometrial lesions, GPER's presence is, at least partially, the result of an inductor effect of ERα on GPER gene transcription. In high-grade lesions, GPER÷ERα ratio was increased, demonstrating that GPER is involved per se in malignant endometrial proliferations.


Asunto(s)
Endometrio/metabolismo , Endometrio/patología , Receptor alfa de Estrógeno/metabolismo , Receptores de Estrógenos/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Proliferación Celular , Femenino , Humanos , Inmunohistoquímica , Células del Estroma/metabolismo , Células del Estroma/patología
14.
Gastrointest Endosc ; 82(1): 59-69, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25792386

RESUMEN

BACKGROUND: The role of EUS with contrast agents can be expanded through the use of time-intensity curve (TIC) analysis and computer-aided interpretation. OBJECTIVE: To validate the use of parameters derived from TIC analysis in an artificial neural network (ANN) classification model designed to diagnose pancreatic carcinoma (PC) and chronic pancreatitis (CP). SETTING: Prospective, multicenter, observational trial-endoscopy units from Romania, Denmark, Germany, and Spain. PATIENTS: A total of 167 consecutive patients with PC or CP. INTERVENTIONS: Contrast-enhanced harmonic EUS (CEH-EUS) and EUS-guided FNA (EUS-FNA), TIC analysis, and ANN processing. MAIN OUTCOME MEASUREMENTS: Sensitivity, specificity, positive and negative predictive values (PPV, NPV) for EUS-FNA, CEH-EUS, and the ANN. RESULTS: After excluding all of the recordings that did not meet the technical and procedural criteria, 112 cases of PC and 55 cases of CP were included. EUS-FNA was performed in 129 patients, and the diagnosis was confirmed by surgery (n = 15) or follow-up (n = 23) in the remaining cases. Its sensitivity and specificity were 84.82% and 100%, respectively, whereas the PPV and NPV were 100% and 76.63%, respectively. The sensitivity of real-time quantitative assessment of CEH-EUS was 87.5%, specificity 92.72%, PPV 96.07%, and NPV 78.46%. Peak enhancement, wash-in area under the curve, wash-in rate, and the wash-in perfusion index were significantly different between the groups. No significant differences were found between rise time, mean transit time, and time to peak. For the ANN, sensitivity was 94.64%, specificity 94.44%, PPV 97.24%, and NPV 89.47%. LIMITATIONS: Only PC and CP lesions were included. CONCLUSION: Parameters obtained through TIC analysis can differentiate between PC and CP cases and can be used in an automated computer-aided diagnostic system with good diagnostic results. ( CLINICAL TRIAL REGISTRATION NUMBER: NCT01315548.).


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Diagnóstico por Computador/métodos , Endosonografía/métodos , Neoplasias Pancreáticas/diagnóstico por imagen , Pancreatitis Crónica/diagnóstico por imagen , Adenocarcinoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Diagnóstico Diferencial , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Neoplasias Pancreáticas/patología , Pancreatitis Crónica/patología , Estudios Prospectivos , Sensibilidad y Especificidad
15.
BMC Gastroenterol ; 13: 2, 2013 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-23286918

RESUMEN

BACKGROUND: Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, as well as improved staging and guidance of therapeutic procedures. METHODS: The aim of our study was to prospectively compare the vascularisation patterns in chronic pseudotumoral pancreatitis and pancreatic cancer using quantitative low mechanical index (MI) contrast-enhanced EUS. We included 51 patients with chronic pseudotumoral pancreatitis (n = 19) and pancreatic cancer (n = 32). Perfusion imaging started with a bolus injection of Sonovue (2.4 ml), followed by analysis in the early arterial (wash-in) and late venous (wash-out) phase. Perfusion analysis was performed by post-processing of the raw data (time intensity curve [TIC] analysis). TIC analysis was performed inside the tumor and the pancreatic parenchyma, with depiction of the dynamic vascular pattern generated by specific software. Statistical analysis was performed on raw data extracted from the TIC analysis. Final diagnosis was based on a combination of EUS-FNA, surgery and follow-up of minimum 6 months in negative cases. RESULTS: The sensitivity and specificity of low MI contrast enhanced EUS using TIC were sensitivity and specificity of low MI contrast enhanced EUS using TIC analysis were 93.75% (95% CI = 77.77-98.91%) and 89.47% (95% CI = 65.46-98.15%), respectively. Pseudotumoral chronic pancreatitis showed in the majority of cases a hypervascular appearance in the early arterial phase of contrast-enhancement, with a dynamic enhancement pattern similar with the rest of the parenchyma. Statistical analysis of the resulting series of individual intensities revealed no statistically relevant differences (p = .78). Pancreatic adenocarcinoma was usually a hypovascular lesion, showing low contrast-enhancement during the early arterial and also during the late venous phase of contrast-enhancement, also lower than the normal surrounding parenchyma. We found statistically significant differences in values during TIC analysis (p < .001). CONCLUSIONS: Low MI contrast enhanced EUS technique is expected to improve the differential diagnosis of focal pancreatic lesions. However, further multicentric randomized studies will confirm the exact role of the technique and its place in imaging assessment of focal pancreatic lesions.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Endosonografía/métodos , Granuloma de Células Plasmáticas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Pancreatitis Crónica/diagnóstico por imagen , Adenocarcinoma/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Diagnóstico Diferencial , Femenino , Granuloma de Células Plasmáticas/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/diagnóstico , Pancreatitis Crónica/diagnóstico , Estudios Prospectivos , Sensibilidad y Especificidad
16.
World J Gastroenterol ; 18(32): 4427-34, 2012 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-22969209

RESUMEN

AIM: To study the role of time-intensity curve (TIC) analysis parameters in a complex system of neural networks designed to classify liver tumors. METHODS: We prospectively included 112 patients with hepatocellular carcinoma (HCC) (n = 41), hypervascular (n = 20) and hypovascular (n = 12) liver metastases, hepatic hemangiomas (n = 16) or focal fatty changes (n = 23) who underwent contrast-enhanced ultrasonography in the Research Center of Gastroenterology and Hepatology, Craiova, Romania. We recorded full length movies of all contrast uptake phases and post-processed them offline by selecting two areas of interest (one for the tumor and one for the healthy surrounding parenchyma) and consecutive TIC analysis. The difference in maximum intensities, the time to reaching them and the aspect of the late/portal phase, as quantified by the neural network and a ratio between median intensities of the central and peripheral areas were analyzed by a feed forward back propagation multi-layer neural network which was trained to classify data into five distinct classes, corresponding to each type of liver lesion. RESULTS: The neural network had 94.45% training accuracy (95% CI: 89.31%-97.21%) and 87.12% testing accuracy (95% CI: 86.83%-93.17%). The automatic classification process registered 93.2% sensitivity, 89.7% specificity, 94.42% positive predictive value and 87.57% negative predictive value. The artificial neural networks (ANN) incorrectly classified as hemangyomas three HCC cases and two hypervascular metastases, while in turn misclassifying four liver hemangyomas as HCC (one case) and hypervascular metastases (three cases). Comparatively, human interpretation of TICs showed 94.1% sensitivity, 90.7% specificity, 95.11% positive predictive value and 88.89% negative predictive value. The accuracy and specificity of the ANN diagnosis system was similar to that of human interpretation of the TICs (P = 0.225 and P = 0.451, respectively). Hepatocellular carcinoma cases showed contrast uptake during the arterial phase followed by wash-out in the portal and first seconds of the late phases. For the hypovascular metastases did not show significant contrast uptake during the arterial phase, which resulted in negative differences between the maximum intensities. We registered wash-out in the late phase for most of the hypervascular metastases. Liver hemangiomas had contrast uptake in the arterial phase without agent wash-out in the portal-late phases. The focal fatty changes did not show any differences from surrounding liver parenchyma, resulting in similar TIC patterns and extracted parameters. CONCLUSION: Neural network analysis of contrast-enhanced ultrasonography - obtained TICs seems a promising field of development for future techniques, providing fast and reliable diagnostic aid for the clinician.


Asunto(s)
Aumento de la Imagen/métodos , Neoplasias Hepáticas/clasificación , Neoplasias Hepáticas/diagnóstico por imagen , Redes Neurales de la Computación , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Hemangioma/diagnóstico , Hemangioma/diagnóstico por imagen , Humanos , Neoplasias Hepáticas/diagnóstico , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia/diagnóstico , Metástasis de la Neoplasia/diagnóstico por imagen , Estudios Prospectivos , Rumanía , Sensibilidad y Especificidad , Factores de Tiempo
17.
Can J Gastroenterol ; 26(8): 532-6, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22891178

RESUMEN

BACKGROUND: Gastric cancer remains one of the most common types of cancer worldwide, with a large geographical variation in incidence and mortality rates. Cytokine polymorphisms are the most studied host polymorphisms and are associated with an increased risk of stomach cancer in many regions, but have not been studied extensively in Eastern European populations. OBJECTIVE: To investigate the potential association between five cytokine promoter polymorphisms (interleukin [IL] 1b -511C→T [rs16944], IL-4 receptor [IL-4R] -3223C→T [rs2057768], IL-8 -251T→A [rs4073], IL-10 -1082A→G [rs1800896] and tumour necrosis factor-alpha -308G→A [rs1800629]) and susceptibility to gastric adenocarcinoma in a Romanian population. METHODS: A total of 347 subjects, consisting of 105 patients with gastric adenocarcinoma and 242 controls, were included. All cytokine polymorphisms were genotyped using allele-specific, commercially available probes. Hardy-Weinberg equilibrium in both groups was analyzed using the chi squared test, and the relationship between targeted polymorphisms and the risk of gastric cancer was estimated using OR and 95% CI. RESULTS: A significant association between the IL-4R -3223C→T polymorphism and risk of gastric cancer was found. Carriers of the IL-4R -3223TT genotype were at a 2.5-fold increased risk for gastric cancer (OR 2.51 [95% CI 1.08 to 5.84]; P=0.041). Moreover, the presence of the IL-4R -3223TT genotype was associated with an increased risk of noncardia gastric adenocarcinoma (OR 3.08 [95% CI 1.25 to 7.58]; P=0.023). No associations were found among the other polymorphisms. CONCLUSION: The results suggest that the IL-4R -3223C→T polymorphism may increase the risk of gastric adenocarcinoma, mainly for the noncardia type, in the Romanian population.


Asunto(s)
Adenocarcinoma/genética , Polimorfismo de Nucleótido Simple , Receptores de Interleucina-4/genética , Neoplasias Gástricas/genética , Adenocarcinoma/etnología , Anciano , Alelos , Distribución de Chi-Cuadrado , Intervalos de Confianza , Femenino , Genotipo , Humanos , Interleucina-10/genética , Interleucina-1beta/genética , Interleucina-8/genética , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Rumanía/epidemiología , Neoplasias Gástricas/etnología , Factor de Necrosis Tumoral alfa/genética , Población Blanca/genética
18.
Med Ultrason ; 14(2): 101-7, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22675709

RESUMEN

AIM: Besides representing angiogenesis markers, microvascular density (MVD) and vascular endothelial growth factor (VEGF) are two important tools for the assessment of prognosis in patients with gastric cancer. The aim of our study was to assess the Doppler parameters (resistivity and pulsatility indexes) and vascularity index (VI) calculated by contrast-enhanced power Doppler endoscopic ultrasound (CEPD-EUS) in correlation with the expression of intra-tumoral MVD and VEGF in patients with gastric cancer. MATERIAL AND METHODS: The study included 20 consecutive patients with advanced gastric carcinoma, but without distant metastasis at initial assessment. All the patients were assessed by contrast-enhanced power Doppler endoscopic ultrasound (EUS) combined with pulsed Doppler examinations in the late venous phase. The vascularity index (VI) was calculated before and after injection of second generation microbubble contrast specific agent (SonoVue 2.4 mL), used as a Doppler signal enhancer. Moreover, pulsed Doppler parameters (resistivity and pulsatility indexes) were further calculated. The correlation between power Doppler parameters and pathological/molecular parameters (MVD assessed through immunohistochemistry with CD31 and CD34, as well as VEGF assessed through real-time PCR) was assessed. Kaplan-Meier survival analysis was used for the assessment of prognosis. RESULTS: Significantly statistical correlations were found between post-contrast VI and CD34 (p=0.0226), VEGF (p=0.0231), VEGF-A (p=0.0464) and VEGF-B (p=0.0022) while pre-contrast VI was correlated only with CD34 expression. Pulsatility index and resistivity index were not correlated with MVD or VEGF expression. Survival analysis demonstrated that VEGF-A is an accurate parameter for survival rate (p=0.045), as compared to VEGF (p=0.085) and VEGF-B (p=0.230). We did not find any correlation between the survival rate and ultrasound parameters (RI, PI, pre-contrast VI or post-contrast VI). CONCLUSION: Assessment of tumor vascularity using contrast-enhanced EUS, including analysis of spectral Doppler parameters is possible and feasible in gastric cancer patients. A correlation between measured EUS vascularity and pathological parameters of angiogenesis (MVD and VEGF expression) was found.


Asunto(s)
Neovascularización Patológica/complicaciones , Neovascularización Patológica/diagnóstico por imagen , Fosfolípidos , Neoplasias Gástricas/complicaciones , Neoplasias Gástricas/diagnóstico por imagen , Hexafluoruro de Azufre , Adulto , Anciano , Medios de Contraste , Endosonografía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Clin Gastroenterol Hepatol ; 10(1): 84-90.e1, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21963957

RESUMEN

BACKGROUND & AIMS: By using strain assessment, real-time endoscopic ultrasound (EUS) elastography provides additional information about a lesion's characteristics in the pancreas. We assessed the accuracy of real-time EUS elastography in focal pancreatic lesions using computer-aided diagnosis by artificial neural network analysis. METHODS: We performed a prospective, blinded, multicentric study at of 258 patients (774 recordings from EUS elastography) who were diagnosed with chronic pancreatitis (n = 47) or pancreatic adenocarcinoma (n = 211) from 13 tertiary academic medical centers in Europe (the European EUS Elastography Multicentric Study Group). We used postprocessing software analysis to compute individual frames of elastography movies recorded by retrieving hue histogram data from a dynamic sequence of EUS elastography into a numeric matrix. The data then were analyzed in an extended neural network analysis, to automatically differentiate benign from malignant patterns. RESULTS: The neural computing approach had 91.14% training accuracy (95% confidence interval [CI], 89.87%-92.42%) and 84.27% testing accuracy (95% CI, 83.09%-85.44%). These results were obtained using the 10-fold cross-validation technique. The statistical analysis of the classification process showed a sensitivity of 87.59%, a specificity of 82.94%, a positive predictive value of 96.25%, and a negative predictive value of 57.22%. Moreover, the corresponding area under the receiver operating characteristic curve was 0.94 (95% CI, 0.91%-0.97%), which was significantly higher than the values obtained by simple mean hue histogram analysis, for which the area under the receiver operating characteristic was 0.85. CONCLUSIONS: Use of the artificial intelligence methodology via artificial neural networks supports the medical decision process, providing fast and accurate diagnoses.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Redes Neurales de la Computación , Enfermedades Pancreáticas/diagnóstico , Enfermedades Pancreáticas/patología , Centros Médicos Académicos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Programas Informáticos , Grabación en Video , Adulto Joven
20.
World J Gastroenterol ; 17(1): 9-14, 2011 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-21218078

RESUMEN

It is well known that angiogenesis is critical in the transition from premalignant to malignant lesions. Consequently, early detection and diagnosis based on morphological changes to the microvessels are crucial. In the last few years, new imaging techniques which utilize the properties of light-tissue interaction have been developed to increase early diagnosis of gastrointestinal (GI) tract neoplasia. We analyzed several "red-flag" endoscopic techniques used to enhance visualization of the vascular pattern of preneoplastic and neoplastic lesions (e.g. trimodal imaging including autofluorescence imaging, magnifying endoscopy and narrow band imaging). These new endoscopic techniques provide better visualization of mucosal microsurface structure and microvascular architecture and may enhance the diagnosis and characterization of mucosal lesions in the GI tract. In the near future, it is expected that trimodal imaging endoscopy will be practiced as a standard endoscopy technique as it is quick, safe and accurate for making a precise diagnosis of gastrointestinal pathology, with an emphasis on the diagnosis of early GI tract cancers. Further large-scale randomized controlled trials comparing these modalities in different patient subpopulations are warranted before their endorsement in the routine practice of GI endoscopy.


Asunto(s)
Diagnóstico por Imagen/métodos , Endoscopía Gastrointestinal/métodos , Neoplasias Gastrointestinales/diagnóstico , Lesiones Precancerosas/diagnóstico , Fluorescencia , Neoplasias Gastrointestinales/patología , Tracto Gastrointestinal/anatomía & histología , Tracto Gastrointestinal/patología , Humanos , Neovascularización Patológica , Lesiones Precancerosas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA