Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Sci Rep ; 14(1): 13253, 2024 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858500

RESUMEN

We aimed to implement four data partitioning strategies evaluated with four federated learning (FL) algorithms and investigate the impact of data distribution on FL model performance in detecting steatosis using B-mode US images. A private dataset (153 patients; 1530 images) and a public dataset (55 patient; 550 images) were included in this retrospective study. The datasets contained patients with metabolic dysfunction-associated fatty liver disease (MAFLD) with biopsy-proven steatosis grades and control individuals without steatosis. We employed four data partitioning strategies to simulate FL scenarios and we assessed four FL algorithms. We investigated the impact of class imbalance and the mismatch between the global and local data distributions on the learning outcome. Classification performance was assessed with area under the receiver operating characteristic curve (AUC) on a separate test set. AUCs were 0.93 (95% CI 0.92, 0.94) for source-based partitioning scenario with FedAvg, 0.90 (95% CI 0.89, 0.91) for a centralized model, and 0.83 (95% CI 0.81, 0.85) for a model trained in a single-center scenario. When data was perfectly balanced on the global level and each site had an identical data distribution, the model yielded an AUC of 0.90 (95% CI 0.88, 0.92). When each site contained data exclusively from one single class, irrespective of the global data distribution, the AUC fell in the range of 0.34-0.70. FL applied to B-mode US images provide performance comparable to a centralized model and higher than single-center scenario. Global data imbalance and local data heterogeneity influenced the learning outcome.


Asunto(s)
Algoritmos , Hígado Graso , Ultrasonografía , Humanos , Ultrasonografía/métodos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Hígado Graso/diagnóstico por imagen , Hígado Graso/patología , Adulto , Curva ROC , Aprendizaje Automático , Área Bajo la Curva , Anciano
2.
Insights Imaging ; 15(1): 113, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734857

RESUMEN

OBJECTIVE: To investigate the structural alterations, neovascularity, and elasticity of tendons and the relationship between elasticity and the Patient Rated Tennis Elbow Evaluation score after undergoing US-guided fenestration or surgery in patients with chronic lateral elbow tendinopathy. METHODS: Participants from the per-protocol population of a randomized trial conducted between October 2016 and June 2020 were included. The surgery and fenestration groups included 24 (mean age, 50 ± 7 years [standard deviation], 10 men) and 29 (47 ± 8 years, 18 men) participants, respectively. Ultrasound exams were performed at baseline, 6 months, and 12 months. Statistical analyses included linear mixed effects and generalized equation estimation models. RESULTS: Fenestration had no significant impact on tendon thickness (p = 0.46). Conversely, surgery significantly increased tendon thickness at 6 months (p < 0.0001) and remained elevated at 12 months (p = 0.04). Tendon echostructure exhibited a group effect (p = 0.03), indicating a higher proportion of pathological scores in the surgery group post-intervention compared to the fenestration group. Both groups showed a similar reduction in neovascularity from 6 to 12 months postintervention (p = 0.006). Shear-wave velocity increased in the fenestration group at 6 months (p = 0.04), while the surgery group experienced a nonsignificant decrease at 6 months, with some improvement at 12 months (p = 0.08). Changes in shear-wave velocity did not correlate with clinical outcome. CONCLUSIONS: Fenestration and surgery reduced tendon neovascularity over time. Unlike surgery, fenestration did not impact tendon size while improving tendon echostructure and elasticity. CRITICAL RELEVANCE STATEMENT: Fenestration and surgery equally alleviated symptoms and decreased tendon neovascularity in lateral elbow tendinopathy; however, fenestration did not alter tendon thickness and improved echostructure and shear-wave velocity, suggesting shear-wave velocity's potential for quantitatively monitoring tendon elasticity during healing. KEY POINTS: Reliable markers for monitoring healing response and informing treatment protocols in elbow tendinopathy are lacking. Fenestration and surgery reduced tendon neovascularity, while fenestration improved tendon echostructure and shear-wave velocity. Shear-wave velocity may provide quantitative measures to monitor tendon elasticity in response to treatment.

3.
J Ultrasound Med ; 43(5): 829-840, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38205972

RESUMEN

OBJECTIVE: The consequences associated with blood clots are numerous and are responsible for many deaths worldwide. The assessment of treatment efficacy is necessary for patient follow-up and to detect treatment-resistant patients. The aim of this study was to characterize the effect of treatment on blood clots in vitro using quantitative ultrasound parameters. METHODS: Blood from 10 pigs was collected to form three clots per pig in gelatin phantoms. Clots were subjected to 1) no treatment, 2) rt-PA (recombinant tissue plasminogen activator) treatment after 20 minutes of clotting, and 3) rt-PA treatment after 60 minutes of clotting. Clots were weighted before and after the experiment to assess the treatment effect by the mass loss. The clot kinetics was studied over 100 minutes using elastography (Young's modulus, shear wave dispersion, and shear wave attenuation). Homodyne K-distribution (HKD) parameters derived from speckle statistics were also studied during clot formation and dissolving (diffuse-to-total signal power ratio and intensity parameters). RESULTS: Treated clots loosed significantly more mass than non-treated ones (P < .005). A significant increase in Young's modulus was observed over time (P < .001), and significant reductions were seen for treated clots at 20 or 60 minutes compared with untreated ones (P < .001). The shear wave dispersion differed for treated clots at 60 minutes versus no treatments (P < .001). The shear wave attenuation decreased over time (P < .001), and was different for clots treated at 20 minutes versus no treatments (P < .031). The HKD intensity parameter varied over time (P < .032), and was lower for clots treated at 20 and 60 minutes than those untreated (P < .001 and P < .02). CONCLUSION: The effect of rt-PA treatment could be confirmed by a decrease in Young's modulus and HKD intensity parameter. The shear wave dispersion and shear wave attenuation were sensitive to late and early treatments, respectively. The Young's modulus, shear wave attenuation, and HKD intensity parameter varied over time despite treatment.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Trombosis , Humanos , Animales , Porcinos , Activador de Tejido Plasminógeno/uso terapéutico , Activador de Tejido Plasminógeno/farmacología , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Ultrasonografía , Coagulación Sanguínea , Módulo de Elasticidad
4.
Radiology ; 309(1): e230659, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37787678

RESUMEN

Background Screening for nonalcoholic fatty liver disease (NAFLD) is suboptimal due to the subjective interpretation of US images. Purpose To evaluate the agreement and diagnostic performance of radiologists and a deep learning model in grading hepatic steatosis in NAFLD at US, with biopsy as the reference standard. Materials and Methods This retrospective study included patients with NAFLD and control patients without hepatic steatosis who underwent abdominal US and contemporaneous liver biopsy from September 2010 to October 2019. Six readers visually graded steatosis on US images twice, 2 weeks apart. Reader agreement was assessed with use of κ statistics. Three deep learning techniques applied to B-mode US images were used to classify dichotomized steatosis grades. Classification performance of human radiologists and the deep learning model for dichotomized steatosis grades (S0, S1, S2, and S3) was assessed with area under the receiver operating characteristic curve (AUC) on a separate test set. Results The study included 199 patients (mean age, 53 years ± 13 [SD]; 101 men). On the test set (n = 52), radiologists had fair interreader agreement (0.34 [95% CI: 0.31, 0.37]) for classifying steatosis grades S0 versus S1 or higher, while AUCs were between 0.49 and 0.84 for radiologists and 0.85 (95% CI: 0.83, 0.87) for the deep learning model. For S0 or S1 versus S2 or S3, radiologists had fair interreader agreement (0.30 [95% CI: 0.27, 0.33]), while AUCs were between 0.57 and 0.76 for radiologists and 0.73 (95% CI: 0.71, 0.75) for the deep learning model. For S2 or lower versus S3, radiologists had fair interreader agreement (0.37 [95% CI: 0.33, 0.40]), while AUCs were between 0.52 and 0.81 for radiologists and 0.67 (95% CI: 0.64, 0.69) for the deep learning model. Conclusion Deep learning approaches applied to B-mode US images provided comparable performance with human readers for detection and grading of hepatic steatosis. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Tuthill in this issue.


Asunto(s)
Aprendizaje Profundo , Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Masculino , Humanos , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Hígado/diagnóstico por imagen , Hígado/patología , Estudios Retrospectivos , Diagnóstico por Imagen de Elasticidad/métodos , Curva ROC , Biopsia/métodos
5.
Ultrasound Med Biol ; 49(10): 2264-2272, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37482477

RESUMEN

OBJECTIVE: The aims of the work described here were to assess shear wave attenuation (SWA) in volunteers and patients with non-alcoholic fatty liver disease (NAFLD) and compare its diagnostic performance with that of shear wave dispersion (SWD), magnetic resonance imaging (MRI) proton density fat fraction (PDFF) and biopsy. METHODS: Forty-nine participants (13 volunteers and 36 NAFLD patients) were enrolled. Ultrasound and MRI examinations were performed in all participants. Biopsy was also performed in patients. SWA was used to assess histopathology grades as potential confounders. The areas under curves (AUCs) of SWA, SWD and MRI-PDFF were assessed in different steatosis grades by biopsy. Youden's thresholds of SWA were obtained for steatosis grading while using biopsy or MRI-PDFF as the reference standard. RESULTS: Spearman's correlations of SWA with histopathology (steatosis, inflammation, ballooning and fibrosis) were 0.89, 0.73, 0.62 and 0.31, respectively. Multiple linear regressions of SWA confirmed the correlation with steatosis grades (adjusted R2 = 0.77, p < 0.001). The AUCs of MRI-PDFF, SWA and SWD were respectively 0.97, 0.99 and 0.94 for S0 versus ≥S1 (p > 0.05); 0.94, 0.98 and 0.78 for ≤S1 versus ≥S2 (both MRI-PDFF and SWA were higher than SWD, p < 0.05); and 0.90, 0.93 and 0.68 for ≤S2 versus S3 (both SWA and MRI-PDFF were higher than SWD, p < 0.05). SWA's Youden thresholds (Np/m/Hz) (sensitivity, specificity) for S0 versus ≥S1, ≤S1 versus ≥S2 and ≤S2 versus S3 were 1.05 (1.00, 0.92), 1.37 (0.96, 0.96) and 1.51 (0.83, 0.87), respectively. These values were 1.16 (1.00, 0.81), 1.49 (0.91, 0.82) and 1.67 (0.87, 0.92) when considering MRI-PDFF as the reference standard. CONCLUSION: In this pilot study, SWA increased with increasing steatosis grades, and its diagnostic performance was higher than that of SWD but equivalent to that of MRI-PDFF.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Hígado/diagnóstico por imagen , Hígado/patología , Proyectos Piloto , Imagen por Resonancia Magnética/métodos , Ultrasonografía/métodos , Protones
6.
Artículo en Inglés | MEDLINE | ID: mdl-36318570

RESUMEN

Attenuation maps or measurements based on the local attenuation coefficient slope (ACS) in quantitative ultrasound (QUS) have shown potential for the diagnosis of liver steatosis. In liver cancers, tissue abnormalities and tumors detected using ACS are also of interest to provide new image contrast to clinicians. Current phantom-based approaches have the limitation of assuming a comparable speed of sound between the reference phantom and insonified tissues. Moreover, these methods present the inconvenience for operators to acquire data on phantoms and patients. The main goal was to alleviate these drawbacks by proposing a methodology for constructing phantom-free regularized (PF-R) local ACS maps and investigate the performance in both homogeneous and heterogeneous media. The proposed method was tested on two tissue-mimicking media with different ACS constructed as homogeneous phantoms, side-by-side and top-to-bottom phantoms, and inclusion phantoms with different attenuations. Moreover, an in vivo proof-of-concept was performed on healthy, steatotic, and cancerous human liver datasets. Modifications brought to previous works include: 1) a linear interpolation of the power spectrum in the log scale; 2) the relaxation of the underlying hypothesis on the diffraction factor; 3) a generalization to nonhomogeneous local ACS; and 4) an adaptive restriction of frequencies to a more reliable range than the usable frequency range. Regularization was formulated as a generalized least absolute shrinkage and selection operator (LASSO), and a variant of the Bayesian information criterion (BIC) was applied to estimate the Lagrangian multiplier on the LASSO constraint. In addition, we evaluated the proposed algorithm when applying median filtering before and after regularization. Tests conducted showed that the PF-R yielded robust results in all tested conditions, suggesting potential for additional validation as a diagnosis method.


Asunto(s)
Algoritmos , Fantasmas de Imagen , Ultrasonografía , Humanos , Teorema de Bayes , Sonido , Ultrasonografía/métodos
7.
Radiology ; 305(3): 526-537, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36255312

RESUMEN

Nonalcoholic fatty liver disease (NAFLD) is believed to affect one-third of American adults. Noninvasive methods that enable detection and monitoring of NAFLD have the potential for great public health benefits. Because of its low cost, portability, and noninvasiveness, US is an attractive alternative to both biopsy and MRI in the assessment of liver steatosis. NAFLD is qualitatively associated with enhanced B-mode US echogenicity, but visual measures of B-mode echogenicity are negatively affected by interobserver variability. Alternatively, quantitative backscatter parameters, including the hepatorenal index and backscatter coefficient, are being investigated with the goal of improving US-based characterization of NAFLD. The American Institute of Ultrasound in Medicine and Radiological Society of North America Quantitative Imaging Biomarkers Alliance are working to standardize US acquisition protocols and data analysis methods to improve the diagnostic performance of the backscatter coefficient in liver fat assessment. This review article explains the science and clinical evidence underlying backscatter for liver fat assessment. Recommendations for data collection are discussed, with the aim of minimizing potential confounding effects associated with technical and biologic variables.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Adulto , Humanos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/patología , Estudios Prospectivos , Hígado/diagnóstico por imagen , Hígado/patología , Ultrasonografía/métodos , Imagen por Resonancia Magnética
8.
Front Med (Lausanne) ; 9: 935482, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36186794

RESUMEN

Background: Mechanical ventilation is a common therapy in operating rooms and intensive care units. When ill-adapted, it can lead to ventilator-induced lung injury (VILI), which is associated with poor outcomes. Excessive regional pulmonary strain is thought to be a major mechanism responsible for VILI. Scarce bedside methods exist to measure regional pulmonary strain. We propose a novel way to measure regional pleural strain using ultrasound elastography. The objective of this study was to assess the feasibility and reliability of pleural strain measurement by ultrasound elastography and to determine if elastography parameters would correlate with varying tidal volumes. Methods: A single-blind randomized crossover proof of concept study was conducted July to October 2017 at a tertiary care referral center. Ten patients requiring general anesthesia for elective surgery were recruited. After induction, patients received tidal volumes of 6, 8, 10, and 12 mL.kg-1 in random order, while pleural ultrasound cineloops were acquired at 4 standardized locations. Ultrasound radiofrequency speckle tracking allowed computing various pleural translation, strain and shear components. We screened 6 elastography parameters (lateral translation, lateral absolute translation, lateral strain, lateral absolute strain, lateral absolute shear and Von Mises Strain) to identify those with the best dose-response with tidal volumes using linear mixed effect models. Goodness-of-fit was assessed by the coefficient of determination. Intraobserver, interobserver and test-retest reliability were calculated using intraclass correlation coefficients. Results: Analysis was possible in 90.7% of ultrasound cineloops. Lateral absolute shear, lateral absolute strain and Von Mises strain varied significantly with tidal volume and offered the best dose-responses and data modeling fits. Point estimates for intraobserver reliability measures were excellent for all 3 parameters (0.94, 0.94, and 0.93, respectively). Point estimates for interobserver (0.84, 0.83, and 0.77, respectively) and test-retest (0.85, 0.82, and 0.76, respectively) reliability measures were good. Conclusion: Strain imaging is feasible and reproducible. Future studies will have to investigate the clinical relevance of this novel imaging modality. Clinical trial registration: www.Clinicaltrials.gov, identifier NCT03092557.

9.
J Acquir Immune Defic Syndr ; 91(1): 91-100, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35510848

RESUMEN

BACKGROUND: There is a need for a specific atherosclerotic risk assessment for people living with HIV (PLWH). SETTING: A machine learning classification model was applied to PLWH and control subjects with low-to-intermediate cardiovascular risks to identify associative predictors of diagnosed carotid artery plaques. Associations with plaques were made using strain elastography in normal sections of the common carotid artery and traditional cardiovascular risk factors. METHODS: One hundred two PLWH and 84 control subjects were recruited from the prospective Canadian HIV and Aging Cohort Study (57 ± 8 years; 159 men). Plaque presence was based on clinical ultrasound scans of left and right common carotid arteries and internal carotid arteries. A classification task for identifying subjects with plaque was defined using random forest (RF) and logistic regression models. Areas under the receiver operating characteristic curves (AUC-ROCs) were applied to select 5 among 50 combinations of 4 or less features yielding the highest AUC-ROCs. RESULTS: To retrospectively classify individuals with and without plaques, the 5 most discriminant combinations of features had AUC-ROCs between 0.76 and 0.79. AUC-ROCs from RF were statistically significantly higher than those obtained with logistic regressions ( P = 0.0001). The most discriminant features of RF classifications in PLWH were age, smoking status, maximum axial strain and pulse pressure (equal weights), and sex and antiretroviral therapy exposure (equal weights). When considering the whole population, the HIV status was identified as a cofactor associated with carotid artery plaques. CONCLUSIONS: Strain elastography adds to traditional cardiovascular risk factors for identifying individuals with carotid artery plaques.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedades de las Arterias Carótidas , Estenosis Carotídea , Infecciones por VIH , Placa Aterosclerótica , Canadá , Enfermedades Cardiovasculares/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/complicaciones , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Estudios de Cohortes , Infecciones por VIH/complicaciones , Infecciones por VIH/tratamiento farmacológico , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Masculino , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo
10.
Eur Radiol ; 32(11): 7612-7622, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35482125

RESUMEN

OBJECTIVE: Evaluate the efficacy of ultrasound-guided dry needling and open-release surgery in reducing pain and improving function in workers with lateral epicondylosis refractory to at least 6 months of nonsurgical management. METHODS: We randomly assigned participants in a 1:1 ratio to receive dry needling or surgery. The primary outcome was the Patient Rated Tennis Elbow Evaluation (PRTEE) score at 6 months. Secondary outcome measures examined the impact of these techniques on professional activity, grip strength, and Global Rating of Change and Satisfaction scales. Statistical analyses included mixed-effects models and Fisher's exact tests. RESULTS: From October 2016 through June 2019, we enrolled 64 participants. Two participants were excluded, and data from 62 participants (48 ± 8 years, 33 men) with a mean duration of symptoms of 23 ± 21 months were analyzed. Baseline characteristics were similar in both groups. In the intention-to-treat analysis, no treatment-by-time interaction was observed (F(4,201) = 0.72; p = .58). The least-squares mean difference from baseline in PRTEE scores at 6 months was 33.4 (CI 25.2 - 41.5) in the surgery group and 26.9 (CI 19.4 - 34.4) in the dry needling group (p = .25). The proportion of successful treatment was 83% (CI 63 - 95%) and 81% (CI 63 - 93%) in the surgery and dry needling groups, respectively (p = 1.00). Changes in secondary outcomes were in the same direction as those of the primary outcome. No adverse event occurred. CONCLUSIONS: Ultrasound-guided dry needling resulted in comparable improvement in outcome scores on scales of pain, physical function, and global assessment of change and satisfaction than open-release surgery. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02710682 KEY POINTS: • In patients with chronic lateral epicondylosis, ultrasound-guided tendon dry needling provides comparable therapeutic efficacy to open-release surgery. • Ultrasound-guided tendon dry needling allows for an earlier return to work and may be less costly than open-release surgery. • Care management guidelines should recommend treatment by ultrasound-guided tendon dry needling before open-release surgery.


Asunto(s)
Punción Seca , Codo de Tenista , Masculino , Humanos , Resultado del Tratamiento , Tendones , Codo de Tenista/cirugía , Dolor , Ultrasonografía Intervencional
11.
Insights Imaging ; 12(1): 127, 2021 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-34499249

RESUMEN

Quantitative ultrasound (QUS) aims at quantifying interactions between ultrasound and biological tissues. QUS techniques extract fundamental physical properties of tissues based on interactions between ultrasound waves and tissue microstructure. These techniques provide quantitative information on sub-resolution properties that are not visible on grayscale (B-mode) imaging. Quantitative data may be represented either as a global measurement or as parametric maps overlaid on B-mode images. Recently, major ultrasound manufacturers have released speed of sound, attenuation, and backscatter packages for tissue characterization and imaging. Established and emerging clinical applications are currently limited and include liver fibrosis staging, liver steatosis grading, and breast cancer characterization. On the other hand, most biological tissues have been studied using experimental QUS methods, and quantitative datasets are available in the literature. This educational review addresses the general topic of biological soft tissue characterization using QUS, with a focus on disseminating technical concepts for clinicians and specialized QUS materials for medical physicists. Advanced but simplified technical descriptions are also provided in separate subsections identified as such. To understand QUS methods, this article reviews types of ultrasound waves, basic concepts of ultrasound wave propagation, ultrasound image formation, point spread function, constructive and destructive wave interferences, radiofrequency data processing, and a summary of different imaging modes. For each major QUS technique, topics include: concept, illustrations, clinical examples, pitfalls, and future directions.

12.
J Acquir Immune Defic Syndr ; 88(2): 186-191, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34138771

RESUMEN

BACKGROUND: Persistent inflammation in HIV infection is associated with elevated cardiovascular disease (CVD) risk, even with viral suppression. Identification of novel surrogate biomarkers can enhance CVD risk stratification and suggest novel therapies. We investigated the potential of interleukin 32 (IL-32), a proinflammatory multi-isoform cytokine, as a biomarker for subclinical carotid artery atherosclerosis in virologically suppressed women living with HIV (WLWH). METHODS AND RESULTS: Nested within the Women's Interagency HIV Study, we conducted a cross-sectional comparison of IL-32 between 399 WLWH and 100 women without HIV, followed by a case-control study of 72 WLWH (36 carotid artery plaque cases vs. 36 age-matched controls without plaque). Plasma IL-32 protein was measured by ELISA, and mRNA of IL-32 isoforms (IL-32α, ß, γ, D, ε, and θ) was quantified by reverse transcription polymerase chain reaction from peripheral blood mononuclear cells. Plasma IL-32 protein levels were higher in WLWH compared with women without HIV (P = 0.02). Among WLWH, although plasma IL-32 levels did not differ significantly between plaque cases and controls, expression of IL-32 isoforms α, ß, and ε mRNA was significantly higher in peripheral blood mononuclear cells from cases (P = 0.01, P = 0.005, and P = 0.018, respectively). Upregulation of IL-32ß and IL-32ε among WLWH with carotid artery plaque persisted after adjustment for age, race/ethnicity, smoking, systolic blood pressure, body mass index, and history of hepatitis C virus (P = 0.04 and P = 0.045); the adjusted association for IL-32α was marginally significant (P = 0.07). CONCLUSIONS: IL-32 isoforms should be studied further as potential CVD biomarkers. This is of particular interest in WLWH by virtue of altered IL-32 levels in this population.


Asunto(s)
Aterosclerosis/complicaciones , Enfermedades de las Arterias Carótidas/complicaciones , Infecciones por VIH/complicaciones , Interleucinas/metabolismo , Placa Aterosclerótica , Aterosclerosis/metabolismo , Biomarcadores , Enfermedades de las Arterias Carótidas/epidemiología , Estudios de Casos y Controles , Estudios Transversales , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Humanos , Interleucinas/genética , Leucocitos Mononucleares , Persona de Mediana Edad , Isoformas de Proteínas , ARN Mensajero
13.
Eur Radiol ; 31(3): 1347-1358, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32876833

RESUMEN

OBJECTIVE: To evaluate the diagnostic performance of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) for grading hepatic inflammation. METHODS: In this retrospective cross-sectional dual-center study, 91 patients with chronic liver disease were recruited between September 2014 and September 2018. Patients underwent 3.0-T MRI examinations within 6 weeks from a liver biopsy. IVIM parameters, perfusion fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*), were estimated using a voxel-wise nonlinear regression on DWI series (10 b-values from 0 to 800 s/mm2). The reference standard was histopathological analysis of hepatic inflammation grade, steatosis grade, and fibrosis stage. Intraclass correlation coefficients (ICC), univariate and multivariate correlation analyses, and areas under receiver operating characteristic curves (AUC) were assessed. RESULTS: Parameters f, D, and D* had ICCs of 0.860, 0.839, and 0.916, respectively. Correlations of f, D, and D* with inflammation grade were ρ = - 0.70, p < 0.0001; ρ = 0.10, p = 0.35; and ρ = - 0.27, p = 0.010, respectively. When adjusting for fibrosis and steatosis, the correlation between f and inflammation (p < 0.0001) remained, and that between f and fibrosis was also significant to a lesser extent (p = 0.002). AUCs of f, D, and D* for distinguishing inflammation grades 0 vs. ≥ 1 were 0.84, 0.53, and 0.70; ≤ 1 vs. ≥ 2 were 0.88, 0.57, and 0.60; and ≤ 2 vs. 3 were 0.86, 0.54, and 0.65, respectively. CONCLUSION: Perfusion fraction f strongly correlated, D very weakly correlated, and D* weakly correlated with inflammation. Among all IVIM parameters, f accurately graded inflammation and showed promise as a biomarker of hepatic inflammation. KEY POINTS: • IVIM parameters derived from DWI series with 10 b-values are reproducible for liver tissue characterization. • This retrospective two-center study showed that perfusion fraction provided good diagnostic performance for distinguishing dichotomized grades of inflammation. • Fibrosis is a significant confounder on the association between inflammation and perfusion fraction.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Hepatopatías , Estudios Transversales , Humanos , Inflamación/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Imagen por Resonancia Magnética , Movimiento (Física) , Estudios Retrospectivos
14.
Eur Radiol ; 30(7): 3879-3889, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32130495

RESUMEN

PURPOSE: To investigate the feasibility of shear wave sonoelastography (SWS) for endoleak detection and thrombus characterization of abdominal aortic aneurysm (AAA) after endovascular repair (EVAR). MATERIALS AND METHODS: Participants who underwent EVAR were prospectively recruited between November 2014 and March 2016 and followed until March 2019. Elasticity maps of AAA were computed using SWS and compared to computed tomography angiography (CTA) and color Doppler ultrasound (CDUS). Two readers, blinded to the CTA and CDUS results, reviewed elasticity maps and B-mode images to detect endoleaks. Three or more CTAs per participant were analyzed: pre-EVAR, baseline post-EVAR, and follow-ups. The primary endpoint was endoleak detection. Secondary endpoints included correlation between total thrombus elasticity, proportion of fresh thrombus, and aneurysm growth between baseline and reference CTAs. A 3-year follow-up was made to detect missed endoleaks, EVAR complication, and mortality. Data analyses included Cohen's kappa; sensitivity, specificity, and positive predictive value (PPV); Pearson coefficient; and Student's t tests. RESULTS: Seven endoleaks in 28 participants were detected by the two SWS readers (k = 0.858). Sensitivity of endoleak detection with SWS was 100%; specificity and PPV averaged 67% and 50%, respectively. CDUS sensitivity was estimated at 43%. Aneurysm growth was significantly greater in the endoleak group compared to sealed AAAs. No correlation between growth and thrombus elasticity or proportion of fresh thrombus in AAAs was found. No new endoleaks were observed in participants with SWS negative studies. CONCLUSION: SWS has the potential to detect endoleaks in AAA after EVAR with comparable sensitivity to CTA and superior sensitivity to CDUS. KEY POINTS: • Dynamic elastography with shear wave sonoelastography (SWS) detected 100% of endoleaks in abdominal aortic aneurysm (AAA) follow-up that were identified by a combination of CT angiography (CTA) and color Doppler ultrasound (CDUS). • Based on elasticity maps, SWS differentiated endoleaks from thrombi within the aneurysm sac (p < 0.001). • After 3-year follow-up, no new endoleaks were observed in SWS negative examinations.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Diagnóstico por Imagen de Elasticidad/métodos , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Trombosis/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad , Ultrasonografía Doppler en Color/métodos
15.
J Magn Reson Imaging ; 51(5): 1570-1580, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31605412

RESUMEN

BACKGROUND: MR elastography is a noninvasive technique that provides high diagnostic accuracy for the staging of liver fibrosis; however, it requires external hardware and mainly assesses the right lobe. PURPOSE: To evaluate the diagnostic performance of MRI cine-tagging for staging fibrosis in the left liver lobe, using biopsy as the reference standard. STUDY TYPE: Institutional Review Board (IRB)-approved two-center prospective study. POPULATION: Seventy-six patients with chronic liver disease who underwent an MRI cine-tagging examination and a liver biopsy within a 6-week interval. FIELD STRENGTH/SEQUENCE: 2D-GRE multislice sequence at 3.0T with spatial modulation of the magnetization preparation sequence and peripheral pulse-wave triggering on two coronal slices chosen underneath the heart apex to capture maximal deformation with consecutive breath-holds adapted to patient cardiac frequency. ASSESSMENT: A region of interest was selected in the liver close to the heart apex. Maximal strain was evaluated with the harmonic phase (HARP) technique. STATISTICAL TESTS: Spearman's correlation, Kruskal-Wallis test, Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were performed. RESULTS: Liver strain measured on tagged images decreased with higher histological fibrosis stage (ρ = -0.68, P < 0.0001). Strain values were significantly different between all fibrosis stages (P < 0.0001), and between groups of fibrosis stages ≤F3 vs. F4 (P < 0.05). Areas under the ROC curves were 0.95 (95% confidence interval: 0.89-1.00) to distinguish fibrosis stages F0 vs. F4, 0.81 (0.70-0.92) for stages F0 vs. ≥F1, 0.84 (0.76-0.93) for stages ≤F1 vs. ≥F2, 0.86 (0.78-0.94) for stages ≤F2 vs. ≥F3, and 0.87 (0.77-0.96) for stages ≤F3 vs. F4. DATA CONCLUSION: MRI cine-tagging is a promising technique for measuring liver strain without additional elastography hardware. It could be used to assess the left liver lobe as a complement to current techniques assessing the right lobe. LEVEL OF EVIDENCE: 1 Technical Efficacy: 3 J. Magn. Reson. Imaging 2020;51:1570-1580.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Cirrosis Hepática , Biopsia , Humanos , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Estudios Prospectivos , Curva ROC
16.
Ultrasound Med Biol ; 46(2): 436-444, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31785840

RESUMEN

The purpose of this study was to evaluate various combinations of 13 features based on shear wave elasticity (SWE), statistical and spectral backscatter properties of tissues, along with the Breast Imaging Reporting and Data System (BI-RADS), for classification of solid breast lesions at ultrasonography by means of random forests. One hundred and three women with 103 suspicious solid breast lesions (BI-RADS categories 4-5) were enrolled. Before biopsy, additional SWE images and a cine sequence of ultrasound images were obtained. The contours of lesions were delineated, and parametric maps of the homodyned-K distribution were computed on three regions: intra-tumoral, supra-tumoral and infra-tumoral zones. Maximum elasticity and total attenuation coefficient were also extracted. Random forests yielded receiver operating characteristic (ROC) curves for various combinations of features. Adding BI-RADS category improved the classification performance of other features. The best result was an area under the ROC curve of 0.97, with 75.9% specificity at 98% sensitivity.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Aprendizaje Automático , Ultrasonografía Mamaria/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Sistemas de Datos , Femenino , Humanos , Persona de Mediana Edad , Proyectos de Investigación , Adulto Joven
17.
Theranostics ; 9(21): 6143-6156, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31534542

RESUMEN

Purpose: Angiogenesis in liver cancers can be characterized by hepatic functional perfusion imaging (FPI) on the basis of dynamic contrast-enhanced ultrasound (DCEUS). However, accuracy is limited by breathing motion which results in out-of-plane image artifacts. Current hepatic FPI studies do not correct for these artifacts and lack the evaluation of correction accuracy. Thus, a hepatic DCEUS-based dual-phase multi-parametric FPI (DM-FPI) scheme using a derivative principal component analysis (PCA) respiratory gating is proposed to overcome these limitations. Materials and Methods: By considering severe 3D out-of-plane respiratory motions, the proposed scheme's accuracy was verified with in vitro DCEUS experiments in a flow model mimicking a hepatic vein. The feasibility was further demonstrated by considering in vivo DCEUS measurements in normal rabbit livers, and hepatic cavernous hemangioma and hepatocellular carcinoma in patients. After respiratory kinetics was extracted through PCA of DCEUS sequences under free-breathing condition, dual-phase respiratory gating microbubble kinetics was identified by using a derivative PCA zero-crossing dual-phase detection, respectively. Six dual-phase hemodynamic parameters were estimated from the dual-phase microbubble kinetics and DM-FPI was then reconstructed via color-coding to quantify 2.5D angiogenic hemodynamic distribution for live tumors. Results: Compared with no respiratory gating, the mean square error of respiratory gating DM-FPI decreased by 1893.9 ± 965.4 (p < 0.05), and mean noise coefficients decreased by 17.5 ± 7.1 (p < 0.05), whereas correlation coefficients improved by 0.4 ± 0.2 (p < 0.01). DM-FPI observably removed severe respiratory motion artifacts on PFI and markedly enhanced the accuracy and robustness both in vitro and in vivo. Conclusions: DM-FPI precisely characterized and distinguished the heterogeneous angiogenic hemodynamics about perfusion volume, blood flow and flow rate within two anatomical sections in the normal liver, and in benign and malignant hepatic tumors. DCEUS-based DM-FPI scheme might be a useful tool to help clinicians diagnose and provide suitable therapies for liver tumors.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen de Perfusión/métodos , Ultrasonografía/métodos , Animales , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/patología , Medios de Contraste , Femenino , Humanos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/patología , Aprendizaje Automático , Masculino , Microburbujas , Análisis de Componente Principal , Conejos , Respiración
18.
Eur Radiol ; 29(12): 6477-6488, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31278577

RESUMEN

OBJECTIVES: To perform head-to-head comparisons of the feasibility and diagnostic performance of transient elastography (TE), point shear-wave elastography (pSWE), and magnetic resonance elastography (MRE). METHODS: This prospective, cross-sectional, dual-center imaging study included 100 patients with known or suspected chronic liver disease caused by hepatitis B or C virus, nonalcoholic fatty liver disease, or autoimmune hepatitis identified between 2014 and 2018. Liver stiffness measured with the three elastographic techniques was obtained within 6 weeks of a liver biopsy. Confounding effects of inflammation and steatosis on association between fibrosis and liver stiffness were assessed. Obuchowski scores and AUCs for staging fibrosis were evaluated and the latter were compared using the DeLong method. RESULTS: TE, pSWE, and MRE were technically feasible and reliable in 92%, 79%, and 91% subjects, respectively. At univariate analysis, liver stiffness measured by all techniques increased with fibrosis stages and inflammation and decreased with steatosis. For classification of dichotomized fibrosis stages, the AUCs were significantly higher for distinguishing stages F0 vs. ≥ F1 with MRE than with TE (0.88 vs. 0.71; p < 0.05) or pSWE (0.88 vs. 0.73; p < 0.05), and for distinguishing stages ≤ F1 vs. ≥ F2 with MRE than with TE (0.85 vs. 0.75; p < 0.05). TE, pSWE, and MRE Obuchowski scores for staging fibrosis stages were respectively 0.89 (95% CI 0.85-0.93), 0.90 (95% CI 0.85-0.94), and 0.94 (95% CI 0.91-0.96). CONCLUSION: MRE provided a higher diagnostic performance than TE and pSWE for staging early stages of liver fibrosis. TRIAL REGISTRATION: NCT02044523 KEY POINTS: • The technical failure rate was similar between MRE and US-based elastography techniques. • Liver stiffness measured by MRE and US-based elastography techniques increased with fibrosis stages and inflammation and decreased with steatosis. • MRE provided a diagnostic accuracy higher than US-based elastography techniques for staging of early stages of histology-determined liver fibrosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Estudios Transversales , Estudios de Factibilidad , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Adulto Joven
19.
BMJ Open ; 8(6): e021373, 2018 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-29886446

RESUMEN

INTRODUCTION: Chronic lateral epicondylosis (CLE) of the elbow is a prevalent condition among middle-aged people with no consensus on optimal care management but for which surgery is generally accepted as a second intention treatment. Among conservative treatment options, ultrasound (US)-guided fenestration has shown encouraging results that should be explored before surgery is considered. The primary objective of this study is to compare the efficacy of US-guided fenestration with open-release surgery in patients with failure to improve following a minimum 6 months of conservative treatment. METHODS AND ANALYSIS: This study protocol entails a two-arm, single-blinded, randomised, controlled design. Sixty-four eligible patients with clinically confirmed CLE will be assigned to either US-guided fenestration or open-release surgery. Fisher's exact test will be used to compare the proportion of patients reporting a change of 11/100 points or more in the Patient Rated Tennis Elbow Evaluation score at 6 months, according to an intention-to-treat analysis. Secondary analyses will compare the two treatment groups in terms of pain and disability, functional limitations at work, pain-free grip strength, medication burden, patients' global impression of change and level of satisfaction at 6 weeks, 3, 6 and 12 months, using mixed linear models for repeated measures or Fisher's exact test, as appropriate. Finally, recursive partitioning analyses will investigate US and elastography parameters as predictors of treatment success at 6 and 12 months. This data will contribute to evidence-based treatment guidelines for CLE and explore the value of imaging biomarkers to improve risk stratification plans and assist clinicians. ETHICS AND DISSEMINATION: The study has been approved by the Research Ethics Board of our institution on 23 March 2016 (REB 15.327). In case of important protocol modifications, a new version of the protocol with appropriate amendments will be submitted to the REB for approval. Study results will be published in peer-reviewed journals and presented at local, national and international conferences. TRIAL REGISTRATION NUMBER: NCT02710682.


Asunto(s)
Satisfacción del Paciente , Calidad de Vida , Codo de Tenista/diagnóstico por imagen , Codo de Tenista/cirugía , Enfermedad Crónica , Humanos , Dolor/etiología , Dimensión del Dolor , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Método Simple Ciego , Tendones , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
20.
Phys Med Biol ; 2018 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-29509143

RESUMEN

Deep vein thrombosis is a common vascular disease that can lead to pulmonary embolism and death. The early diagnosis and clot age staging are important parameters for reliable therapy planning. This article presents an acoustic radiation force induced resonance elastography method for the viscoelastic characterization of clotting blood. The physical concept of this method relies on the mechanical resonance of the blood clot occurring at specific frequencies. Resonances are induced by focusing ultrasound beams inside the sample under investigation. Coupled to an analytical model of wave scattering, the ability of the proposed method to characterize the viscoelasticity of a mimicked venous thrombosis in the acute phase is demonstrated. Experiments with a gelatin-agar inclusion sample of known viscoelasticity are performed for validation and establishment of the proof of concept. In addition, an inversion method is applied in-vitro for the kinetic monitoring of the blood coagulation process of six human blood samples obtained from two volunteers. The computed elasticity and viscosity values of blood samples at the end of the 90 min kinetics were estimated at 411 ± 71 Pa and 0.25 ± 0.03 Pa.s for volunteer #1, and 387 ± 35 Pa and 0.23 ± 0.02 Pa.s for volunteer #2, respectively. The proposed method allowed reproducible time-varying thrombus viscoelastic measurements from samples having physiological dimensions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA