Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Diabetes Complications ; 38(4): 108721, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38471431

RESUMEN

AIMS: To investigate the association between diabetic retinopathy (DR) and coronary artery disease (CAD) using coronary angiotomography (CCTA) and multimodal retinal imaging (MMRI) with ultra-widefield retinography and optical coherence tomography angiography and structural domain. METHODS: Single-center, cross-sectional, single-blind. Patients with diabetes who had undergone CCTA underwent MMRI. Uni and multivariate analysis were used to assess the association between CAD and DR and to identify variables independently associated with DR. RESULTS: We included 171 patients, 87 CAD and 84 non-CAD. Most CAD patients were males (74 % vs 38 %, P < 0.01), insulin users (52 % vs 38 %, p < 0.01) and revascularized (64 %). They had a higher prevalence of DR (48 % vs 22 %, p = 0.01), microaneurysms (25 % vs 13 %, p = 0.04), intraretinal cysts (22 % vs 8 %, p = 0.01) and areas of reduced capillary density (46 % vs 20 %, p < 0.01). CAD patients also had lower mean vascular density (MVD) (15.7 % vs 16.5,%, p = 0.049) and foveal avascular zone (FAZ) circularity (0.64 ± 0.1 vs 0.69 ± 0.1, p = 0.04). There were significant and negative correlations between Duke coronary score and MVD (r = -0.189; p = 0.03) and FAZ circularity (r = -0,206; p = 0.02). CAD, DM duration and insulin use independently associated with DR. CONCLUSIONS: CAD patients had higher prevalence of DR and lower MVD. CAD, DM duration and insulin use were independently associated with DR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Retinopatía Diabética , Insulinas , Masculino , Humanos , Femenino , Retinopatía Diabética/diagnóstico , Retinopatía Diabética/diagnóstico por imagen , Estudios Transversales , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Método Simple Ciego , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
2.
Insights Imaging ; 10(1): 62, 2019 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-31197500

RESUMEN

OBJECTIVES: To provide clinical validation of a recent 2D SENSE-based accelerated cardiovascular magnetic resonance (CMR) sequence (accelerated k-t SENSE), investigating whether this technique accurately quantifies left ventricle (LV) volumes, function, and mass as compared to 2D cine steady-state free precession (2D-SSFP). METHODS: Healthy volunteers (n = 16) and consecutive heart failure patients (n = 26) were scanned using a 1.5 T MRI system. Two LV short axis (SA) stacks were acquired: (1) accelerated k-t SENSE (5-6 breath-holds; temporal/spatial resolution: 37 ms/1.82 × 1.87 mm; acceleration factor = 4) and (2) standard 2D-SSFP (10-12 breath-holds; temporal/spatial resolution: 49 ms/1.67 × 1.87 mm, parallel imaging). Ascending aorta phase-contrast was performed on all volunteers as a reference to compare LV stroke volumes (LVSV) and validate the sequences. An image quality score for SA images was used, with lower scores indicating better quality (from 0 to 18). RESULTS: There was a high agreement between accelerated k-t SENSE and 2D-SSFP for LV measurements: bias (limits of agreement) of 2.4% (- 5.4% to 10.1%), 6.9 mL/m2 (- 4.7 to 18.6 mL/m2), - 1.5 (- 8.3 to 5.2 mL/m2), and - 0.2 g/m2 (- 11.9 to 12.3 g/m2) for LV ejection fraction, end-diastolic volume index, end-systolic volume index, and mass index, respectively. LVSV by accelerated k-t SENSE presented good agreement with aortic flow. Interobserver and intraobserver variabilities for all LV parameters were also high. CONCLUSION: The accelerated k-t SENSE CMR sequence is clinically feasible and accurately quantifies LV volumes, function, and mass, with short acquisition time and good image quality.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA