Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38448258

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Remoción de Dispositivos , Sistema de Registros , Humanos , Masculino , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Femenino , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Fibrilación Atrial/terapia , Fibrilación Atrial/mortalidad , Remoción de Dispositivos/efectos adversos , Embolia/etiología , Embolia/mortalidad , Persona de Mediana Edad , Dispositivo Oclusor Septal , Cierre del Apéndice Auricular Izquierdo
2.
JACC Clin Electrophysiol ; 10(1): 31-39, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37943190

RESUMEN

BACKGROUND: Bilateral cardiac sympathetic denervation (BCSD) for refractory life-threatening ventricular arrhythmias is a neuromodulatory intervention targeting sympathetically driven focal or re-entrant ventricular arrhythmias. OBJECTIVES: This study sought to provide a more complete and successful option for intervention in patients in whom premature ventricular contraction (PVC) ablation is not feasible or has been unsuccessful. METHODS: A total of 43 patients with >5% PVC burden and concomitant nonischemic cardiomyopathy (NICM) who previously failed medical and ablation therapies were referred for BCSD. All patients underwent bilateral video-assisted thoracoscopic surgical approach with T1-T4 sympathectomy. Primary effectiveness endpoints were postprocedural PVC burden resolution, improvement in left ventricular ejection fraction (LVEF), and cessation of antiarrhythmic drugs (AADs). Safety endpoints included peri- and postprocedural complications. Outcomes were assessed over a 1-year follow-up period. RESULTS: Among the 43 patients who underwent BCSD, the mean age was 52.3 ± 14.7 years, 69.8% of whom were male patients. Presenting mean LVEF was 38.7% ± 7.8%, and PVC burden was 23.7% ± 9.9%. There were significant reductions in PVC burden postprocedurally (1.3% ± 1.1% post-BCSD, compared with 23.7% ± 9.9% pre-BCSD, P < 0.001) and improvements in LVEF (46.3% ± 9.5% post-BCSD, compared with 38.7% ± 7.8% pre-BCSD, P < 0.001). The rate of ICD therapies decreased from 81.4% (n = 35) to 11.6% (n = 5) (P < 0.001), leading to a significant reduction in use of AADs (100.0% to 11.6%, P < 0.001) and improvement in mean NYHA functional class (2.5 ± 0.5 to 1.4 ± 0.2, P < 0.001). Major intraoperative complications were seen in 4.7% of patients (hemothorax and chylothorax). Of the patients, 81.4% (n = 35) experienced no mortality or major complications over a 1-year follow-up period, with the remaining still within their first year postprocedure. CONCLUSIONS: BCSD is effective for the management of refractory PVCs and ventricular tachycardia who have failed previous ablation therapy.


Asunto(s)
Cardiomiopatías , Complejos Prematuros Ventriculares , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Volumen Sistólico , Función Ventricular Izquierda , Antiarrítmicos/uso terapéutico , Simpatectomía/efectos adversos , Simpatectomía/métodos
3.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378783

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Complejos Prematuros Ventriculares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Prevalencia , Volumen Sistólico , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/epidemiología , Complejos Prematuros Ventriculares/cirugía , Ablación por Catéter/efectos adversos
4.
J Interv Card Electrophysiol ; 66(6): 1383-1389, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36456653

RESUMEN

INTRODUCTION: Complex atrial tachyarrhythmias (CATs) are commonly observed in patients with prior catheter ablation or cardiac surgery. These arrhythmias are challenging to map and ablate. Historically, entrainment mapping was utilized to characterize CAT. With the advent of high-definition mapping (HDM), full visualization of the CAT circuit is possible which may obviate the need for entrainment mapping. METHODS: We sought to investigate the outcomes of catheter ablation of CAT guided only by HDM. Consecutive patients who underwent CAT ablation from 2017 to 2021 were included in our study (excluding right atrial tachyarrhythmias). Patients were sorted by the type of mapping performed. Group I consisted of patients where HDM alone was utilized with no attempt of entrainment. Group II consisted of patients where both entrainment and HDM were utilized. RESULTS: A total of 67 patients were included in our study, with 40 patients in HDM group (I) and 27 patients in entrainment group (II). No statistically significant difference regarding 1-year freedom from atrial arrhythmias was found between the two groups (80% vs 77.8%, p = 0.819). Four CATs were terminated by entrainment during procedure versus none in the HDM-only group (p = 0.011). CONCLUSIONS: CAT ablation with HDM alone yielded similar 1-year freedom from atrial arrhythmias compared to ablation with HDM and entrainment. Entrainment combined with HDM was associated with higher undesired CAT interruption rate. Further validation is needed with randomized control trials.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Taquicardia/cirugía , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos
5.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38245007

RESUMEN

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Anciano , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Puntaje de Propensión , Resultado del Tratamiento , Atrios Cardíacos , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
6.
Card Electrophysiol Clin ; 13(2): 303-311, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33990269

RESUMEN

Intracardiac echocardiography (ICE) is a valuable tool and should be standard of care in any modern electrophysiology laboratory. Through real-time imaging of cardiac anatomy, ICE is used to guide electrophysiology procedures and monitor for complications. This article is a short overview of the application of real-time ICE imaging during atrial fibrillation ablation procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía/métodos , Cirugía Asistida por Computador/métodos , Humanos
7.
Heart Rhythm ; 17(9): 1575-1581, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32389681

RESUMEN

BACKGROUND: Single-chamber leadless pacemakers (LPs) have been shown to be an effective alternative to conventional transvenous pacemakers (CTPs), but their benefit in the context of cardioinhibitory vasovagal syncope (CI-VVS) is unknown. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of LP compared with dual-chamber CTP for CI-VVS. METHODS: We conducted a multicenter, retrospective study comparing patients who received LP or dual-chamber CTP for drug-refractory CI-VVS. CI-VVS was diagnosed clinically and supported by cardiac monitoring and head-up tilt table testing. The primary efficacy endpoint was freedom from syncope during follow-up. Secondary endpoints included device efficacy and safety estimated by device-related major and minor adverse events (AEs). RESULTS: Seventy-two patients (24 LP, 48 CTP; age 32 ± 5.5 years; 90% female; syncope frequency 7.6 ± 3.4 per year) were included. At 1 year, 91% of patients (22/24) in the LP group and 94% of patients (43/48) in the CTP group met the primary efficacy endpoint (P = .7). Device efficacy endpoint was met in 92% of the LP group and 98% of the CTP group (P = .2). Early major AEs occurred in 2 of 24 in the LP group and 3 of 48 in the CTP group (P = .4). Late major AEs occurred in 0 of 24 in the LP group and 2 of 48 in the CTP group (P = 1). CONCLUSION: In patients with CI-VVS, single-chamber LP demonstrated equivalent efficacy in reducing syncopal events compared to dual-chamber CTP, with a similar safety profile.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial , Síncope Vasovagal/terapia , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Recurrencia , Estudios Retrospectivos , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatología , Pruebas de Mesa Inclinada , Resultado del Tratamiento , Adulto Joven
8.
Card Electrophysiol Clin ; 12(2): 233-245, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32451107

RESUMEN

Fluoroscopy continues to be considered an indispensable part of atrial fibrillation (AF) ablation worldwide. Deleterious effects of radiation exposure to patients, physicians, and catheter laboratory personnel are gaining increased consideration. Safety and efficacy of a fluoroless approach for AF ablation is comparable with outcomes achieved with fluoroscopy use. This article focuses on AF ablation with zero fluoroscopy use as well as current evidence on efficacy and safety of this technique. In contrast, minimal fluoroscopy is an alternative. Relying on intracardiac echocardiography for transseptal access and electroanatomic mapping for catheter manipulation can help implement this approach on a wider scale.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter/métodos , Ecocardiografía , Cirugía Asistida por Computador/métodos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Mapeo Epicárdico , Fluoroscopía/efectos adversos , Humanos
9.
J Cardiovasc Electrophysiol ; 31(8): 2168-2171, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32293063

RESUMEN

There are important limitations that can hinder outcomes of surgical ablation in nonparoxysmal patients with atrial fibrillation (AF), which is the typical AF population undergoing concomitant cardiac surgery for valve or ischemic heart disease. Incomplete lesions with recovered conduction or gaps as well as arrhythmias originating from areas not targeted by surgical ablation are commonly seen at the time of recurrence. Therefore, while it might be reasonable to perform AF surgery in this cohort, it is important to know these limitations and establish adequate postoperative rhythm monitoring to detect recurrences, which can be effectively addressed by catheter ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Frecuencia Cardíaca , Humanos , Recurrencia , Resultado del Tratamiento
10.
JACC Cardiovasc Interv ; 13(3): 306-319, 2020 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-31954677

RESUMEN

OBJECTIVES: The aim of this study was to assess the feasibility and efficacy of transcatheter leak closure with detachable coils in patients with incomplete left atrial appendage (LAA) closure. BACKGROUND: Incomplete LAA closure is common after interventional therapies targeting the LAA, potentially hindering effective thromboembolic prevention. Detachable coils have found a wide range of applications for transcatheter vascular occlusion and embolization procedures. METHODS: Thirty consecutive patients at high thromboembolic risk with clinically relevant residual leaks (mean age 72 ± 9 years, 73.3% men, mean CHA2DS2-VASc score 4.4 ± 1.4, mean HAS-BLED score 3.6 ± 0.8) underwent percutaneous closure of the LAA patency using embolization coils. Transesophageal echocardiography was performed at 60 ± 15 days post-procedure. RESULTS: LAA closure had been previously attempted with the Watchman device in 25 patients, the Amulet device in 2 patients, and the LARIAT device in 3 patients. Baseline transesophageal echocardiography documented moderate and severe leaks in 20 (66.7%) and 10 (33.3%) patients, respectively. After a single procedure, 25 patients (83.3%) showed complete LAA sealing or minimal leaks. Five patients (16.7%) had moderate residual leaks; 3 patients of them were offered repeat procedures. Mean procedure and fluoroscopy times were 76 ± 41 min and 21 ± 14 min, respectively; the mean volume of iodinated contrast medium used was 80 ± 47 ml. Coil deployment was successful in all cases. The overall complication rate was 6.1%. After a median follow-up period of 54 days (range 43 to 265 days) and an average of 1.1 procedures/patient, transesophageal echocardiography revealed complete LAA sealing or negligible residual leaks in 28 patients (93.3%; 25 with no residual leak, 3 patients with minimal to mild residual leaks) and moderate residual leaks in 2 patients (6.7%). CONCLUSIONS: Transcatheter LAA leak occlusion using endovascular coils appears to be a safe, effective, and promising approach in patients at high echo time risk with incomplete LAA closure. (Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures [TREASURE]; NCT03503253).


Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Embolización Terapéutica/instrumentación , Tromboembolia/prevención & control , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Embolización Terapéutica/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Tromboembolia/diagnóstico , Tromboembolia/etiología , Factores de Tiempo , Resultado del Tratamiento
11.
Regen Med ; 9(6): 793-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25431915

RESUMEN

Stem/progenitor cell-based therapies offer novel treatment for many prevalent diseases. However, most physicians are not trained or introduced to cell therapy. We describe a model of a training program aimed at empowering physician-scientists with the knowledge and skills necessary for advancing the field of cardiovascular cell therapy. To date, five full-time scholars have completed this training program, obtained a full-time academic appointment in Cardiovascular Disease, and continue to actively contribute to the advancement of cell therapy applications. Another has returned to his parent institution to complete his PhD and several part-time scholars have continued in scholarly activities in other academic programs.


Asunto(s)
Investigación Biomédica/educación , Enfermedades Cardiovasculares/terapia , Tratamiento Basado en Trasplante de Células y Tejidos , Educación Médica , Médicos , Medicina Regenerativa/educación , Becas , Humanos , National Heart, Lung, and Blood Institute (U.S.) , Trasplante de Células Madre , Estados Unidos
12.
Ann Thorac Surg ; 95(3): 1081-4, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23438538

RESUMEN

Perforation and migration of pacemaker electrodes into the pleural cavity is a rare event. We report the clinical course and surgical treatment of massive acute hemothorax resulting from intercostal artery laceration, caused by a retained active-fixation pacing lead implanted 10 months earlier.


Asunto(s)
Bloqueo Atrioventricular/terapia , Remoción de Dispositivos/métodos , Electrodos Implantados/efectos adversos , Hemotórax/etiología , Marcapaso Artificial/efectos adversos , Enfermedad Aguda , Anciano de 80 o más Años , Electrocardiografía , Femenino , Estudios de Seguimiento , Hemotórax/diagnóstico , Hemotórax/cirugía , Humanos , Factores de Tiempo , Tomografía Computarizada por Rayos X
13.
Med Hypotheses ; 79(5): 673-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22939314

RESUMEN

Despite remarkable effectiveness of reperfusion and drug therapies to reduce morbidity and mortality following myocardial infarction (MI), many patients have debilitating symptoms and impaired left ventricular (LV) function highlighting the need for improved post-MI therapies. A promising concept currently under investigation is intramyocardial injection of high-water content, polymeric biomaterial gels (e.g., hydrogels) to modulate myocardial scar formation and LV adverse remodeling. We propose a degradable, bioactive hydrogel that forms a unique microstructure of continuous, parallel capillary-like channels (Capgel). We hypothesize that the innovative architecture and composition of Capgel can serve as a platform for endogenous cell recruitment and drug/cell delivery, therefore facilitating myocardial repair after MI.


Asunto(s)
Alginatos/química , Infarto del Miocardio/terapia , Factor de Células Madre/administración & dosificación , Trasplante de Células Madre , Humanos , Hidrogeles , Microscopía Electrónica de Rastreo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA