Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Arch Pathol Lab Med ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38631690

RESUMEN

CONTEXT.­: Laboratories performing predictive marker testing for breast carcinoma are encouraged to compare patient results to published benchmarks. OBJECTIVE.­: To collect expression rates for estrogen receptor (ER), progesterone receptor (PgR), and human epidermal growth factor receptor 2 (HER2) in invasive breast carcinoma from multiple laboratories. DESIGN.­: Participants submitted data from up to 50 primary cases during the study period. Participants reported ER, PgR, and HER2 results in addition to demographic and histologic information. Participants also provided annual institution-level expression rates. RESULTS.­: A total of 21 institutions submitted data for 687 cases. Aggregate positivity rates for ER and PgR were 85.6% and 75.1%, respectively. Receptor positivity rates were higher in well-differentiated (grade 1) tumors (ER, 97.4%; PgR, 88.0%) compared with moderately differentiated (grade 2) tumors (ER, 92.4%; PgR, 84.0%) and poorly differentiated (grade 3) tumors (ER, 61.8%; PgR, 48.0%). Expression rates were higher in postmenopausal women (ER, 87.2%) than premenopausal women (ER, 79.6%) and higher in lobular carcinomas (ER, 98.7%; PgR, 85.3%) than ductal carcinomas (ER, 84.1%; PgR, 74.5%). The aggregate HER2 positivity (score 3+) rate was 9.0%. The aggregate HER2 equivocal (score 2+) rate was 14.5%. Of 81 equivocal (score 2+) cases, 70 (86.4%) were nonamplified. CONCLUSIONS.­: The data from this study provide multi-institutional benchmark data to assist laboratories performing periodic comparisons as part of a quality management program. Overall expression rates were generally similar to those of other published reports, with the exception of the ER-negative and HER2-positive rates, both of which were somewhat lower.

2.
Cancers (Basel) ; 15(17)2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37686613

RESUMEN

Dynamic biomarkers that permit the real-time monitoring of the tumor microenvironment response to therapy are an unmet need in breast cancer. Breast magnetic resonance imaging (MRI) has demonstrated value as a predictor of pathologic complete response and may reflect immune cell changes in the tumor microenvironment. The purpose of this pilot study was to investigate the value of breast MRI features as early markers of treatment-induced immune response. Fourteen patients with early HER2+ breast cancer were enrolled in a window-of-opportunity study where a single dose of trastuzumab was administered and both tissue and MRIs were obtained at the pre- and post-treatment stages. Functional diffusion-weighted and dynamic contrast-enhanced MRI tumor measures were compared with tumor-infiltrating lymphocytes (TILs) and RNA immune signature scores. Both the pre-treatment apparent diffusion coefficient (ADC) and the change in peak percent enhancement (DPE) were associated with increased tumor-infiltrating lymphocytes with trastuzumab therapy (r = -0.67 and -0.69, p < 0.01 and p < 0.01, respectively). Low pre-treatment ADC and a greater decrease in PE in response to treatment were also associated with immune-activated tumor microenvironments as defined by RNA immune signatures. Breast MRI features hold promise as biomarkers of early immune response to treatment in HER2+ breast cancer.

3.
JMIR Med Educ ; 8(2): e30988, 2022 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-35486423

RESUMEN

BACKGROUND: Residents may benefit from simulated practice with personalized feedback to prepare for high-stakes disclosure conversations with patients after harmful errors and to meet American Council on Graduate Medical Education mandates. Ideally, feedback would come from patients who have experienced communication after medical harm, but medical researchers and leaders have found it difficult to reach this community, which has made this approach impractical at scale. The Video-Based Communication Assessment app is designed to engage crowdsourced laypeople to rate physician communication skills but has not been evaluated for use with medical harm scenarios. OBJECTIVE: We aimed to compare the reliability of 2 assessment groups (crowdsourced laypeople and patient advocates) in rating physician error disclosure communication skills using the Video-Based Communication Assessment app. METHODS: Internal medicine residents used the Video-Based Communication Assessment app; the case, which consisted of 3 sequential vignettes, depicted a delayed diagnosis of breast cancer. Panels of patient advocates who have experienced harmful medical error, either personally or through a family member, and crowdsourced laypeople used a 5-point scale to rate the residents' error disclosure communication skills (6 items) based on audiorecorded responses. Ratings were aggregated across items and vignettes to create a numerical communication score for each physician. We used analysis of variance, to compare stringency, and Pearson correlation between patient advocates and laypeople, to identify whether rank order would be preserved between groups. We used generalizability theory to examine the difference in assessment reliability between patient advocates and laypeople. RESULTS: Internal medicine residents (n=20) used the Video-Based Communication Assessment app. All patient advocates (n=8) and 42 of 59 crowdsourced laypeople who had been recruited provided complete, high-quality ratings. Patient advocates rated communication more stringently than crowdsourced laypeople (patient advocates: mean 3.19, SD 0.55; laypeople: mean 3.55, SD 0.40; P<.001), but patient advocates' and crowdsourced laypeople's ratings of physicians were highly correlated (r=0.82, P<.001). Reliability for 8 raters and 6 vignettes was acceptable (patient advocates: G coefficient 0.82; crowdsourced laypeople: G coefficient 0.65). Decision studies estimated that 12 crowdsourced layperson raters and 9 vignettes would yield an acceptable G coefficient of 0.75. CONCLUSIONS: Crowdsourced laypeople may represent a sustainable source of reliable assessments of physician error disclosure skills. For a simulated case involving delayed diagnosis of breast cancer, laypeople correctly identified high and low performers. However, at least 12 raters and 9 vignettes are required to ensure adequate reliability and future studies are warranted. Crowdsourced laypeople rate less stringently than raters who have experienced harm. Future research should examine the value of the Video-Based Communication Assessment app for formative assessment, summative assessment, and just-in-time coaching of error disclosure communication skills.

4.
J Biomed Opt ; 27(3)2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35315258

RESUMEN

SIGNIFICANCE: For breast cancer patients, the extent of regional lymph node (LN) metastasis influences the decision to remove all axillary LNs. Metastases are currently identified and classified with visual analysis of a few thin tissue sections with conventional histology that may underrepresent the extent of metastases. AIM: We sought to enable nondestructive three-dimensional (3D) pathology of human axillary LNs and to develop a practical workflow for LN staging with our method. We also sought to evaluate whether 3D pathology improves staging accuracy in comparison to two-dimensional (2D) histology. APPROACH: We developed a method to fluorescently stain and optically clear LN specimens for comprehensive imaging with multiresolution open-top light-sheet microscopy. We present an efficient imaging and data-processing workflow for rapid evaluation of H&E-like datasets in 3D, with low-resolution screening to identify potential metastases followed by high-resolution localized imaging to confirm malignancy. RESULTS: We simulate LN staging with 3D and 2D pathology datasets from 10 metastatic nodes, showing that 2D pathology consistently underestimates metastasis size, including instances in which 3D pathology would lead to upstaging of the metastasis with important implications on clinical treatment. CONCLUSIONS: Our 3D pathology method may improve clinical management for breast cancer patients by improving staging accuracy of LN metastases.


Asunto(s)
Neoplasias de la Mama , Axila/patología , Neoplasias de la Mama/patología , Femenino , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática/diagnóstico por imagen , Estadificación de Neoplasias
5.
Lab Chip ; 22(7): 1354-1364, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35212692

RESUMEN

Minimally invasive core needle biopsies for medical diagnoses have become increasingly common for many diseases. Although tissue cores can yield more diagnostic information than fine needle biopsies and cytologic evaluations, there is no rapid assessment at the point-of-care for intact tissue cores that is low-cost and non-destructive to the biopsy. We have developed a proof-of-concept 3D printed millifluidic histopathology lab-on-a-chip device to automatically handle, process, and image fresh core needle biopsies. This device, named CoreView, includes modules for biopsy removal from the acquisition tool, transport, staining and rinsing, imaging, segmentation, and multiplexed storage. Reliable removal from side-cutting needles and bidirectional fluid transport of core needle biopsies of five tissue types has been demonstrated with 0.5 mm positioning accuracy. Automation is aided by a MATLAB-based biopsy tracking algorithm that can detect the location of tissue and air bubbles in the channels of the millifluidic chip. With current and emerging optical imaging technologies, CoreView can be used for a rapid adequacy test at the point-of-care for tissue identification as well as glomeruli counting in renal core needle biopsies.


Asunto(s)
Algoritmos , Riñón , Biopsia , Biopsia con Aguja Gruesa
6.
Theranostics ; 10(13): 5865-5878, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32483424

RESUMEN

Calcifications play an essential role in early breast cancer detection and diagnosis. However, information regarding the chemical composition of calcifications identified on mammography and histology is limited. Detailed spectroscopy reveals an association between the chemical composition of calcifications and breast cancer, warranting the development of novel analytical tools to better define calcification types. Previous investigations average calcification composition across broad tissue sections with no spatially resolved information or provide qualitative visualization, which prevents a robust linking of specific spatially resolved changes in calcification chemistry with the pathologic process. Method: To visualize breast calcification chemical composition at high spatial resolution, we apply hyperspectral stimulated Raman scattering (SRS) microscopy to study breast calcifications associated with a spectrum of breast changes ranging from benign to neoplastic processes, including atypical ductal hyperplasia, ductal carcinoma in situ, and invasive ductal carcinoma. The carbonate content of individual breast calcifications is quantified using a simple ratiometric analysis. Results: Our findings reveal that intra-sample calcification carbonate content is closely associated with local pathological processes. Single calcification analysis supports previous studies demonstrating decreasing average carbonate level with increasing malignant potential. Sensitivity and specificity reach >85% when carbonate content level is used as the single differentiator in separating benign from neoplastic processes. However, the average carbonate content is limiting when trying to separate specific diagnostic categories, such as fibroadenoma and invasive ductal carcinoma. Second harmonic generation (SHG) data can provide critical information to bridge this gap. Conclusion: SRS, combined with SHG, can be a valuable tool in better understanding calcifications in carcinogenesis, diagnosis, and possible prognosis. This study not only reveals previously unknown large variations of breast microcalcifications in association with local malignancy but also corroborates the clinical value of linking microcalcification chemistry to breast malignancy. More importantly, it represents an important step in the development of a label-free imaging strategy for breast cancer diagnosis with tremendous potential to address major challenges in diagnostic discordance in pathology.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Espectrometría Raman/métodos , Adulto , Enfermedades de la Mama/patología , Neoplasias de la Mama/química , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Calcinosis/patología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Mamografía/métodos , Persona de Mediana Edad , Sensibilidad y Especificidad
7.
Biomed Opt Express ; 10(3): 1257-1272, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30891344

RESUMEN

Open-top light-sheet microscopy is a technique that can potentially enable rapid ex vivo inspection of large tissue surfaces and volumes. Here, we have optimized an open-top light-sheet (OTLS) microscope and image-processing workflow for the comprehensive examination of surgical margin surfaces, and have also developed a novel fluorescent analog of H&E staining that is robust for staining fresh unfixed tissues. Our tissue-staining method can be achieved within 2.5 minutes followed by OTLS microscopy of lumpectomy surfaces at a rate of up to 1.5 cm2/minute. An image atlas is presented to show that OTLS image quality surpasses that of intraoperative frozen sectioning and can approximate that of gold-standard H&E histology of formalin-fixed paraffin-embedded (FFPE) tissues. Qualitative evidence indicates that these intraoperative methods do not interfere with downstream post-operative H&E histology and immunohistochemistry. These results should facilitate the translation of OTLS microscopy for intraoperative guidance of lumpectomy and other surgical oncology procedures.

8.
J Biomed Opt ; 24(2): 1-11, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30737911

RESUMEN

Intraoperative assessment of breast surgical margins will be of value for reducing the rate of re-excision surgeries for lumpectomy patients. While frozen-section histology is used for intraoperative guidance of certain cancers, it provides limited sampling of the margin surface (typically <1 % of the margin) and is inferior to gold-standard histology, especially for fatty tissues that do not freeze well, such as breast specimens. Microscopy with ultraviolet surface excitation (MUSE) is a nondestructive superficial optical-sectioning technique that has the potential to enable rapid, high-resolution examination of excised margin surfaces. Here, a MUSE system is developed with fully automated sample translation to image fresh tissue surfaces over large areas and at multiple levels of defocus, at a rate of ∼5 min / cm2. Surface extraction is used to improve the comprehensiveness of surface imaging, and 3-D deconvolution is used to improve resolution and contrast. In addition, an improved fluorescent analog of conventional H&E staining is developed to label fresh tissues within ∼5 min for MUSE imaging. We compare the image quality of our MUSE system with both frozen-section and conventional H&E histology, demonstrating the feasibility to provide microscopic visualization of breast margin surfaces at speeds that are relevant for intraoperative use.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Márgenes de Escisión , Microscopía Ultravioleta/métodos , Imagen Óptica/métodos , Animales , Mama/cirugía , Neoplasias de la Mama/cirugía , Carcinoma/diagnóstico por imagen , Carcinoma/cirugía , Femenino , Secciones por Congelación , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Riñón/diagnóstico por imagen , Mastectomía Segmentaria , Ratones , Microscopía Fluorescente/métodos , Microscopía Ultravioleta/instrumentación , Imagen Óptica/instrumentación , Propiedades de Superficie
9.
Appl Immunohistochem Mol Morphol ; 27(9): 637-643, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30358609

RESUMEN

Immunohistochemistry (IHC) is often critical for distinction between metastatic carcinomas of Mullerian organ and breast origin. Paired box family protein 8 (PAX8) has been described as a transcription factor highly specific to neoplasms derived from Mullerian organs, thyroid, and kidney. PAX8 IHC with polyclonal and monoclonal antibody reagents was performed on 27 primary and 22 metastatic breast carcinomas. Eight of 27 primary breast carcinomas (30%) were positive for PAX8 with the monoclonal antibody reagent only; 0 of 22 were polyclonal anti-PAX8 immunoreactive. Substantial numbers of metastases had positive immunoreactivity for polyclonal anti-PAX8 (23%). Each of these metastases and additional cases (45% total) also had positive immunoreactivity for monoclonal anti-PAX8, including 5 of 7 brain metastases. IHC with monoclonal anti-PAX8 was positive on 6 of 7 primary breast carcinomas corresponding to PAX8-positive metastases. Together, these results indicate a significant fraction of breast carcinoma metastases and corresponding primary neoplasms have immunoreactivity for PAX8, and positivity rates depend on the antibody used. Diagnoses of metastatic breast carcinoma were achieved with the aid of clinical history and additional IHC in cases of PAX8 immunoreactivity. Contextual interpretation is imperative for PAX8 IHC, particularly when the differential diagnosis includes metastatic breast carcinoma with limited diagnostic material available.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Inmunohistoquímica/métodos , Tumor Mulleriano Mixto/diagnóstico , Tumor Mulleriano Mixto/metabolismo , Factor de Transcripción PAX8/metabolismo , Anticuerpos Monoclonales , Biomarcadores de Tumor/metabolismo , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Humanos , Tumor Mulleriano Mixto/patología , Metástasis de la Neoplasia , Estadificación de Neoplasias , Factor de Transcripción PAX8/inmunología
10.
Arch Pathol Lab Med ; 143(9): 1076-1083, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30550350

RESUMEN

CONTEXT.­: Resection of breast carcinoma with adequate margins reduces the risk of local recurrence and reoperation. Tozuleristide (BLZ-100) is an investigational peptide-fluorophore agent that may aid in intraoperative tumor detection and margin assessment. In this study, fluorescence imaging was conducted ex vivo on gross breast pathology specimens. OBJECTIVES.­: To determine the potential of tozuleristide to detect breast carcinoma in fresh pathology specimens and the feasibility of fluorescence-guided intraoperative pathology assessment of surgical margins. DESIGN.­: Twenty-three patients received an intravenous bolus dose of 6 or 12 mg of tozuleristide at least 1 hour before surgery. Fifteen lumpectomy and 12 mastectomy specimens were evaluated for fluorescence by the site's clinical pathology staff using the SIRIS, an investigational near-infrared imaging device. The breast tissue was then processed per usual procedures. Fluorescent patterns were correlated with the corresponding hematoxylin-eosin-stained sections. Clinical pathology reports were used to correlate fluorescent signal to grade, histotype, prognostic marker status, and margin measurements. RESULTS.­: Tozuleristide fluorescence was readily observed in invasive and in situ breast carcinoma specimens. Most invasive carcinomas were bright and focal, whereas in situ lesions demonstrated a less intense, more diffuse pattern. Tozuleristide was detected in ductal and lobular carcinomas with a similar fluorescent pattern. Fluorescence was detected in high- and low-grade lesions, and molecular marker/hormone receptor status did not affect signal. Fluorescence could be used to identify the relationship of carcinoma to margins intraoperatively. CONCLUSIONS.­: Tumor targeting with tozuleristide allowed visual real-time distinction between pathologically confirmed breast carcinoma and normal tissue.


Asunto(s)
Carcinoma de Mama in situ/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Lobular/diagnóstico por imagen , Colorantes Fluorescentes , Verde de Indocianina/análogos & derivados , Venenos de Escorpión , Carcinoma de Mama in situ/patología , Carcinoma de Mama in situ/cirugía , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Carcinoma Lobular/patología , Carcinoma Lobular/cirugía , Femenino , Humanos , Cuidados Intraoperatorios/métodos , Márgenes de Escisión , Mastectomía , Mastectomía Segmentaria , Invasividad Neoplásica/diagnóstico por imagen , Invasividad Neoplásica/patología , Pronóstico
11.
Adv Anat Pathol ; 25(2): 124-130, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29356714

RESUMEN

Harmful error is an infrequent but serious challenge in the pathology laboratory. Regulatory bodies and advocacy groups have mandated and encouraged disclosure of error to patients. Many pathologists are interested in participating in disclosure of harmful error but are ill-equipped to do so. This review of the literature with recommendations examines the current state of the patient safety movement and error disclosure as it pertains to pathology and provides a practical and explicit guide for pathologists for who, when, and how to disclose harmful pathology error to patients. The authors provide a definition of harmful pathology error, and the rationale and principles behind effective disclosure are discussed. The changing culture of medicine and its effect on pathology is examined including the trend towards increasing transparency and patient engagement. Related topics are addressed including the management of expected adverse events, barriers to disclosure, and additional resources for the implementation of disclosure programs in pathology.


Asunto(s)
Errores Médicos , Patología , Revelación de la Verdad , Humanos , Patólogos
12.
Cancer Res ; 77(16): 4506-4516, 2017 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-28615226

RESUMEN

Intraoperative identification of carcinoma at lumpectomy margins would enable reduced re-excision rates, which are currently as high as 20% to 50%. Although imaging of disease-associated biomarkers can identify malignancies with high specificity, multiplexed imaging of such biomarkers is necessary to detect molecularly heterogeneous carcinomas with high sensitivity. We have developed a Raman-encoded molecular imaging (REMI) technique in which targeted nanoparticles are topically applied on excised tissues to enable rapid visualization of a multiplexed panel of cell surface biomarkers at surgical margin surfaces. A first-ever clinical study was performed in which 57 fresh specimens were imaged with REMI to simultaneously quantify the expression of four biomarkers HER2, ER, EGFR, and CD44. Combined detection of these biomarkers enabled REMI to achieve 89.3% sensitivity and 92.1% specificity for the detection of breast carcinoma. These results highlight the sensitivity and specificity of REMI to detect biomarkers in freshly resected tissue, which has the potential to reduce the rate of re-excision procedures in cancer patients. Cancer Res; 77(16); 4506-16. ©2017 AACR.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Mastectomía Segmentaria/instrumentación , Imagen Molecular/instrumentación , Imagen Molecular/métodos , Nanopartículas/metabolismo , Neoplasias de la Mama/patología , Femenino , Humanos , Mastectomía Segmentaria/métodos
13.
Arch Pathol Lab Med ; 141(6): 841-845, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28362155

RESUMEN

CONTEXT: - Medical errors are unfortunately common. The US Institute of Medicine proposed guidelines for mitigating and disclosing errors. Implementing these recommendations in pathology will require a better understanding of how errors occur in pathology, the relationship between pathologists and treating clinicians in reducing error, and pathologists' experiences with and attitudes toward disclosure of medical error. OBJECTIVE: - To understand pathologists' attitudes toward disclosing pathology error to treating clinicians and patients. DESIGN: - We conducted 5 structured focus groups in Washington State and Missouri with 45 pathologists in academic and community practice. Participants were questioned about pathology errors, how clinicians respond to pathology errors, and what roles pathologists should play in error disclosure to patients. RESULTS: - These pathologists believe that neither treating physicians nor patients understand the subtleties and limitations of pathologic diagnoses, which complicates discussions about pathology errors. Pathologists' lack of confidence in communication skills and fear of being misrepresented or misunderstood are major barriers to their participation in disclosure discussions. Pathologists see potential for their future involvement in disclosing error to patients, but at present advocate reliance on treating clinicians to disclose pathology errors to patients. Most group members believed that going forward pathologists should offer to participate more actively in error disclosure to patients. CONCLUSIONS: - Pathologists lack confidence in error disclosure communication skills with both treating physicians and patients. Improved communication between pathologists and treating physicians could enhance transparency and promote disclosure of pathology errors. Consensus guidelines for best practices in pathology error disclosure may be useful.


Asunto(s)
Actitud del Personal de Salud , Errores Médicos/psicología , Patólogos/psicología , Adulto , Comunicación , Femenino , Humanos , Masculino , Errores Médicos/ética , Persona de Mediana Edad , Missouri , Revelación de la Verdad
14.
Mod Pathol ; 30(2): 227-235, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27739440

RESUMEN

The 2013 CAP/ASCO HER2 Testing Guidelines Update modified HER2 FISH categories such that some cases with 'monosomy', 'co-amplification/polysomy', low-level increased HER2 signals or clustered heterogeneity now are considered amplified or equivocal. This study examines the frequency and clinico-pathologic characteristics of breast cancers with equivocal or 'non-classical' HER2 FISH results. Breast cancers (2001-2014) with HER2 FISH results, HER2 immunohistochemistry, ER, grade, and age from three institutions (Stanford, UCSF, UWMC) were collected. HER2 FISH was interpreted using the updated recommendations. Amplified cases with non-classical results were grouped into the following categories: (1) 'monosomy' (ratio ≥2.0, mean HER2/cell<4.0); (2) 'co-amplified' (ratio<2.0, mean HER2/cell ≥6.0); (3) 'low amplified' (ratio ≥2.0, mean HER2/cell 4.0-5.9). Heterogeneous cases with clustered HER2-positive cells were also included. Of 8068 cases, 5.2% were equivocal and 4.6% had a 'non-classical' HER2 amplified result; 1.4% 'monosomy', 0.8% 'co-amplified', 2.1% 'low amplified', and 0.3% clustered heterogeneity. These cancers had a high frequency of ER positive (80.4%), Nottingham grade 3 (52.1%) results. The highest percentage of grade 3 cancers (66.7%) and positive HER2 immunohistochemistry (31.7%) was in the 'co-amplified' group. The 'monosomy' group had the highest percent grade 1 cancers (13.3%) and was most frequently HER2 immunohistochemistry negative (30.1%). Equivocal cases had very similar characteristics to the 'low-amplified' category. Cases with non-classical HER2 amplification or equivocal results are typically ER positive, higher grade cancers. 'Co-amplified' cases have the highest frequencies of aggressive characteristics and 'monosomy' cases the highest frequencies of lower risk features. With little clinical outcomes data currently available on these non-classical HER2 results, these results support the current classification scheme for HER2 FISH, with case-by-case correlation with additional clinical-pathologic factors when evaluating whether to offer HER2-targeted therapies in these non-classical cases.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Hibridación Fluorescente in Situ , Receptor ErbB-2/análisis , Biomarcadores de Tumor/análisis , Neoplasias de la Mama/genética , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Femenino , Amplificación de Genes , Humanos , Inmunohistoquímica , Clasificación del Tumor
15.
Arch Pathol Lab Med ; 140(12): 1390-1396, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27610645

RESUMEN

CONTEXT: - Surgical specimen adverse events can lead to delays in treatment or diagnosis, misdiagnosis, reoperation, inappropriate treatment, and anxiety or serious patient harm. OBJECTIVES: - To describe the types and frequency of event reports associated with the management of surgical specimens, the contributing factors, and the level of harm associated with these events. DESIGN: - A retrospective review was undertaken of surgical specimen adverse events and near misses voluntarily reported in the University HealthSystem Consortium Safety Intelligence Patient Safety Organization database by more than 50 health care facilities during a 3-year period (2011-2013). Event reports that involved surgical specimen management were reviewed for patients undergoing surgery during which tissue or fluid was sent to the pathology department. RESULTS: - Six hundred forty-eight surgical specimen events were reported in all stages of the specimen management process, with the most common events reported during the prelaboratory phase and, specifically, with specimen labeling, collection/preservation, and transport. The most common contributing factors were failures in handoff communication, staff inattention, knowledge deficit, and environmental issues. Eight percent of the events (52 of 648) resulted in either the need for additional treatment or temporary or permanent harm to the patient. CONCLUSIONS: - All phases of specimen handling and processing are vulnerable to errors. These results provide a starting point for health care organizations to conduct proactive risk analyses of specimen handling procedures and to design safer processes. Particular attention should be paid to effective communication and handoffs, consistent processes across care areas, and staff training. In addition, organizations should consider the use of technology-based identification and tracking systems.


Asunto(s)
Errores Diagnósticos/prevención & control , Errores Médicos/prevención & control , Potencial Evento Adverso , Patología Clínica/métodos , Seguridad del Paciente , Manejo de Especímenes , Procedimientos Quirúrgicos Operativos , Atención , Competencia Clínica , Comunicación , Errores Diagnósticos/efectos adversos , Registros Electrónicos de Salud , Ambiente de Instituciones de Salud , Hospitales Universitarios , Humanos , Errores Médicos/efectos adversos , Patología Clínica/normas , Seguridad del Paciente/normas , Guías de Práctica Clínica como Asunto , Estudios Retrospectivos , Manejo de Especímenes/normas , Factores de Tiempo , Conservación de Tejido , Estados Unidos , United States Agency for Healthcare Research and Quality
16.
Sci Rep ; 6: 21242, 2016 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-26878888

RESUMEN

There is a need to image excised tissues during tumor-resection procedures in order to identify residual tumors at the margins and to guide their complete removal. The imaging of dysregulated cell-surface receptors is a potential means of identifying the presence of diseases with high sensitivity and specificity. However, due to heterogeneities in the expression of protein biomarkers in tumors, molecular-imaging technologies should ideally be capable of visualizing a multiplexed panel of cancer biomarkers. Here, we demonstrate that the topical application and quantification of a multiplexed cocktail of receptor-targeted surface-enhanced Raman scattering (SERS) nanoparticles (NPs) enables rapid quantitative molecular phenotyping (QMP) of the surface of freshly excised tissues to determine the presence of disease. In order to mitigate the ambiguity due to nonspecific sources of contrast such as off-target binding or uneven delivery, a ratiometric method is employed to quantify the specific vs. nonspecific binding of the multiplexed NPs. Validation experiments with human tumor cell lines, fresh human tumor xenografts in mice, and fresh human breast specimens demonstrate that QMP imaging of excised tissues agrees with flow cytometry and immunohistochemistry, and that this technique may be achieved in less than 15 minutes for potential intraoperative use in guiding breast-conserving surgeries.


Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/cirugía , Mastectomía Segmentaria/métodos , Imagen Molecular/métodos , Nanopartículas , Receptores de Superficie Celular , Espectrometría Raman/métodos , Animales , Modelos Animales de Enfermedad , Femenino , Xenoinjertos , Humanos , Márgenes de Escisión , Ratones , Nanopartículas/química , Receptores de Superficie Celular/metabolismo , Cirugía Asistida por Computador
17.
J Mol Diagn ; 16(1): 56-67, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24189654

RESUMEN

Recent years have seen development and implementation of anticancer therapies targeted to particular gene mutations, but methods to assay clinical cancer specimens in a comprehensive way for the critical mutations remain underdeveloped. We have developed UW-OncoPlex, a clinical molecular diagnostic assay to provide simultaneous deep-sequencing information, based on >500× average coverage, for all classes of mutations in 194 clinically relevant genes. To validate UW-OncoPlex, we tested 98 previously characterized clinical tumor specimens from 10 different cancer types, including 41 formalin-fixed paraffin-embedded tissue samples. Mixing studies indicated reliable mutation detection in samples with ≥ 10% tumor cells. In clinical samples with ≥ 10% tumor cells, UW-OncoPlex correctly identified 129 of 130 known mutations [sensitivity 99.2%, (95% CI, 95.8%-99.9%)], including single nucleotide variants, small insertions and deletions, internal tandem duplications, gene copy number gains and amplifications, gene copy losses, chromosomal gains and losses, and actionable genomic rearrangements, including ALK-EML4, ROS1, PML-RARA, and BCR-ABL. In the same samples, the assay also identified actionable point mutations in genes not previously analyzed and novel gene rearrangements of MLL and GRIK4 in melanoma, and of ASXL1, PIK3R1, and SGCZ in acute myeloid leukemia. To best guide existing and emerging treatment regimens and facilitate integration of genomic testing with patient care, we developed a framework for data analysis, decision support, and reporting clinically actionable results.


Asunto(s)
Técnicas de Diagnóstico Molecular/métodos , Neoplasias/diagnóstico , Neoplasias/genética , Análisis de Secuencia de ADN/métodos , Variaciones en el Número de Copia de ADN/genética , Perfilación de la Expresión Génica , Regulación Neoplásica de la Expresión Génica , Reordenamiento Génico/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Límite de Detección , Mutación , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Polimorfismo de Nucleótido Simple/genética
18.
Transl Oncol ; 6(4): 458-69, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23908689

RESUMEN

Deregulation of DNA repair enzymes occurs in cancers and may create a susceptibility to chemotherapy. Expression levels of DNA repair enzymes have been shown to predict the responsiveness of cancers to certain chemotherapeutic agents. The RECQ helicases repair damaged DNA including damage caused by topoisomerase I inhibitors, such as irinotecan. Altered expression levels of these enzymes in colorectal cancer (CRC) may influence the response of the cancers to irinotecan. Thus, we assessed RECQ helicase (WRN, BLM, RECQL, RECQL4, and RECQL5) expression in primary CRCs, matched normal colon, and CRC cell lines. We found that BLM and RECQL4 mRNA levels are significantly increased in CRC (P = .0011 and P < .0001, respectively), whereas RECQL and RECQL5 are significantly decreased (P = .0103 and P = .0029, respectively). RECQ helicase expression patterns varied between specific molecular subtypes of CRCs. The mRNA and protein expression of the majority of the RECQ helicases was closely correlated, suggesting that altered mRNA expression is the predominant mechanism for deregulated RECQ helicase expression. Immunohistochemistry localized the RECQ helicases to the nucleus. RECQ helicase expression is altered in CRC, suggesting that RECQ helicase expression has potential to identify CRCs that are susceptible to specific chemotherapeutic agents.

19.
Ann Surg Oncol ; 19(3): 914-21, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21861212

RESUMEN

BACKGROUND: The surgical management of lobular in-situ neoplasia (LN) identified by core needle biopsy (CNB) is currently variable. Our institution has routinely excised LN on CNB since 2003, allowing for an unbiased assessment of upgrade rates. METHODS: Cases of LN on CNB, including atypical lobular hyperplasia (ALH) and lobular carcinoma-in-situ (LCIS), were identified in our pathology database. CNBs with concurrent pleomorphic LCIS, ductal carcinoma-in-situ (DCIS), and invasive carcinoma were excluded. Imaging indication/modality, biopsy indication, and radiologic concordance were determined. Pathology review included scoring total foci of LN in each CNB. Upgrade rates to invasive carcinoma or DCIS at excision were calculated. RESULTS: A total of 106 cases of LN (73 ALH and 33 LCIS) on CNB were identified. Thirty patients had concurrent atypical ductal hyperplasia (ADH) and 76 had LN alone; 93 (88%) of the patients had available surgical follow-up (25 LN + ADH and 68 LN alone). The upgrade rate at excision was 16% (4 of 25) for LN + ADH and 4.4% (3 of 68) for LN alone. Patients with LN alone and discordant imaging, imaging for high-risk indications, or extensive LCIS (>4 foci) accounted for all the upgrades. Normal-risk patients who underwent biopsy to assess calcifications found by routine mammographic screening with LN alone did not result in upgrade. CONCLUSIONS: Women with a CNB diagnosis of LN for calcifications found on routine, normal-risk mammographic screening have a negligible risk of upgrade and may not require excisional biopsy. However, excisional biopsy should be offered to women undergoing imaging for other indications or with >4 foci of LN on CNB.


Asunto(s)
Biopsia con Aguja , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/cirugía , Carcinoma in Situ/diagnóstico , Carcinoma in Situ/cirugía , Carcinoma Lobular/diagnóstico , Carcinoma Lobular/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Carcinoma in Situ/diagnóstico por imagen , Carcinoma in Situ/patología , Carcinoma Lobular/patología , Femenino , Humanos , Hiperplasia , Imagen por Resonancia Magnética , Mamografía , Persona de Mediana Edad , Ultrasonografía Mamaria
20.
Am J Clin Pathol ; 136(6): 864-71, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22095371

RESUMEN

In 2009, a College of American Pathologists expert panel published supplemental HER2 testing recommendations suggesting that cases with between 5% and 50% individual cells amplified by fluorescence in situ hybridization be reported as "heterogeneous for HER2 gene amplification." We examined the implications of applying these recommendations to clinical practice in 1,329 consecutive breast cancer cases. By ratio criteria, 23.2% of cases met the proposed criteria for heterogeneity, of which 81.6% were not amplified and 15.5% were equivocal by standard criteria. In contrast, the proposed criteria based on HER2 signals per cell classified only 6.5% of cases as heterogeneous, of which only 8% (7/87) were not amplified and 79% (69/87) were equivocal by standard criteria. These results show that the 2 proposed criteria sets are not equivalent and that the ratio-based definition results in large numbers of nonamplified cases being classified as heterogeneous. Further definition of optimal criteria with clinical relevance is needed before HER2 heterogeneity reporting is adopted in routine practice.


Asunto(s)
Neoplasias de la Mama/genética , Genes erbB-2 , Receptor ErbB-2/genética , Neoplasias de la Mama/patología , Femenino , Humanos , Hibridación Fluorescente in Situ/métodos , Guías de Práctica Clínica como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA