Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Biomed Phys Eng Express ; 10(6)2024 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-39191263

RESUMEN

Purpose. Pulsed volumetric modulated arc therapy (VMAT) was proposed as an advanced treatment that combines the biological benefits of pulsed low dose rate (PLDR) and the dosimetric benefits of the intensity-modulated beams. In our conventional pulsed VMAT technique, a daily fractional dose of 200 cGy is delivered in 10 arcs with 3 min intervals between the arcs. In this study, we are testing the feasibility of pulsed VMAT that omits the need to split into ten arcs and excludes any beam-off gaps.Methods. The study was conducted using computed tomographic images of 24 patients previously treated at our institution with the conventional PLDR technique. Our newly installed Elekta machine has a low dose rate option on the order of 25 MU min-1. PLDR requires an effective dose rate of 6.7 cGy min-1with attention being paid to the maximum dose received within any point within the target not to exceed 13 cGy min-1. The quality of treatment plans was judged based on dose-volume histograms, isodose distribution, dose conformality to the target, and target dose homogeneity. The dose delivery accuracy was assessed by measurements using theMatriXXEvolution2D array system.Results. All cases were normalized to cover 95% of the target volume with 100% of the prescription dose. The average conformity index was 1.03 ± 0.08 while the average homogeneity index was 1.05 ± 0.02. The maximum reported dose rate at any point within the target was 10.44 cGy min-1. The mean dose rate for all pulsed VMAT plans was 6.88 ± 0.1 cGy min-1. All cases passed our gamma analysis with an average passing rate of 99.00% ± 0.48%.Conclusion. The study showed the applicability of planning pulsed VMAT using Eclipse and its successful delivery on our Elekta linac. Pulsed VMAT using the machine's low dose rate mode is more efficient than our previous pulsed VMAT delivery.


Asunto(s)
Aceleradores de Partículas , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias/radioterapia
2.
Acta Obstet Gynecol Scand ; 103(9): 1745-1752, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38922851

RESUMEN

INTRODUCTION: Colposcopy is an important part of the diagnostic work-up of women with an abnormal cervical screening test as it is used to guide the collection of biopsies. Although quality assurance has been used in the evaluation of screening programs, not much is known about quality indicators for the diagnostics and treatment of screen-positive women. Therefore, the European Federation for Colposcopy developed quality indicators aiming to support colposcopy practice across Europe. We performed a survey of colposcopy cases to determine if the quality indicators are understandable, relevant, and reproducible. MATERIAL AND METHODS: We conducted a survey among all members of the European Federation for Colposcopy Quality and Standards Group from November 2022 to March 2023. Members were asked to collect information on a total of 17 quality indicators for 50 women who had been newly referred for colposcopy due to an abnormal screening test between January 1, 2020 to December 31, 2021. Results were reported descriptively. RESULTS: We included data on 609 cases from 12 members across Europe. The majority of the quality indicators were either achieved or within reach of the agreed standard, often due to few countries with outlying data. One quality indicator had very low performance, although stratified results indicated that two countries had different clinical management of the patient type thereby skewing the results. In addition, discrepancies between the number of cases included in each quality indicator raised concerns regarding potential misunderstanding of the quality indicator and its objective. CONCLUSIONS: Quality indicators on colposcopy must be understandable to those collecting data, highlighting the importance of validating quality indicators before data collection.


Asunto(s)
Colposcopía , Indicadores de Calidad de la Atención de Salud , Neoplasias del Cuello Uterino , Humanos , Colposcopía/normas , Colposcopía/estadística & datos numéricos , Femenino , Europa (Continente) , Reproducibilidad de los Resultados , Adulto , Neoplasias del Cuello Uterino/diagnóstico , Encuestas y Cuestionarios , Persona de Mediana Edad , Sociedades Médicas , Detección Precoz del Cáncer/normas
3.
Arthroplast Today ; 26: 101322, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38455866

RESUMEN

Background: Hip osteoarthritis is associated with an aging population with the average total hip arthroplasty patient in the U.S. approximately 65 years of age. Although there is an association between femoroacetabular impingement and early arthritis, there is a paucity of data attributed to variation in native acetabular version and early onset osteoarthritis. We investigated that whether patients with relative acetabular retroversion are predisposed to earlier hip osteoarthritis. Methods: Five hundred sixteen charts of patients undergoing THA by a single surgeon between March 2018 and May 2022 were reviewed (221 male and 295 female subjects; mean age 66.7 years [standard deviation (SD) 9.8]). Patients with advanced dysplasia, who are post-traumatic, septic, have inflammatory arthritis, and osteonecrosis were excluded. Operative hip anteversion was measured using three-dimensional computed tomography. A univariate analysis was used to correlate the age of male and female subjects with anteversion angles of ≤15° and >15°. The effect of age and gender on version angle was studied using a multivariate linear regression model. Results: In patients with anteversion ≤15°, both male (P = .006) and female subjects (P = .015) presented at significantly lesser age (male: 98, avg. age: 63.7, SD: 8.7; female: 62, avg. age: 64.8, SD: 9.8) than those with anteversion >15° (male: 123, avg. age: 67.2, SD: 10.2; female: 233, avg. age: 68.2, SD: 9.8). Male subjects had lower anteversion than female subjects with age held constant (P < .001), and older patients had increased anteversion with gender held constant (P < .001). Conclusions: This study suggests that patients with a relatively decreased version angle (≤15°) are more likely to present with earlier-onset symptomatic hip osteoarthritis.

4.
Eur J Orthop Surg Traumatol ; 33(8): 3671-3676, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37278874

RESUMEN

BACKGROUND: Despite continued advances in techniques and implant designs, a population of patients who are dissatisfied after total knee arthroplasty (TKA) remains. During robotic-assisted arthroplasty, real-time intraoperative assessment of patient knee alignment is performed. Here, we assess the prevalence of an under-appreciated deformity, reverse coronal deformity (RCD), and the benefits of utilizing robotic-assisted knee arthroplasty to help correct this dynamic deformity. METHODS: A retrospective study evaluating patients undergoing robotic-assisted cruciate-retaining TKA was performed. Intraoperative measurements were obtained using tibial and femoral arrays to assess coronal plane deformity at full extension and at 90° flexion. RCD was defined as ≥ 2° varus in knee extension that reversed to ≥ 2° valgus in flexion, or vice-versa. Coronal plane deformity was then reassessed after robotic-assisted bony resection and implant placement. RESULTS: Of 204 patients that underwent TKA, 16 patients (7.8%) were found to have RCD, with 14 patients (87.5%) transitioning from varus in extension to valgus in flexion. The average coronal deformity was 7.75°, with a maximum of 12°. These improved to an average coronal change of 0.93° post-TKA. Final medial and lateral gaps were all balanced to within 1° in extension and flexion. Another 34 patients (16.7%) had ≥ 5° change in coronal plane deformity from extension to flexion (average 6.39°), however, did not experience a reversal of their coronal deformity. Outcomes were assessed with KOOS Jr. scores postoperatively. CONCLUSION: Computer and robotic assistance were utilized to demonstrate the prevalence of RCD. We also demonstrated accurate identification and successfully balancing of RCD utilizing robotic-assisted TKA. An increased awareness of these dynamic deformities could aid surgeons in proper gap balancing even in the absence of navigation and robotic-assisted surgery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Rango del Movimiento Articular
5.
Eur J Orthop Surg Traumatol ; 33(7): 2889-2894, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36894707

RESUMEN

PURPOSE: While bone health is instrumental in orthopedic surgery, few studies have described the long-term outcomes of osteoporosis (OP) in patients undergoing total hip (THA) or knee (TKA) arthroplasties. METHODS: Using the New York State statewide planning and research cooperative system database, all patients who underwent primary TKA or THA for osteoarthritis from 2009 to 2011 with minimum 2-year follow-up were identified. They were divided based on their OP status (OP and non-OP) and 1:1 propensity score matched for age, sex, race, and Charlson/Deyo index. Cohorts were compared for demographics, hospital-related parameters, and 2-year postoperative complications and reoperations. Multivariate binary logistic regression was utilized to identify significant independent associations with 2-year medical and surgical complications and revisions. RESULTS: A total of 11,288 TKA and 8248 THA patients were identified. OP and non-OP TKA patients incurred comparable overall hospital charges for their surgical visit and hospital length of stay (LOS) (both, p ≥ 0.125). Though OP and non-OP THA patients incurred similar mean hospital charges for their surgical visit, they experienced longer hospital LOS (4.3 vs. 4.1 days, p = 0.035). For both TKA and THA, OP patients had higher rates of overall and individual medical and surgical complications (all, p < 0.05). OP was independently associated with the 2-year occurrence of any overall, surgical, and medical complications, and any revision in TKA and THA patients (all, OR ≥ 1.42, p < 0.001). CONCLUSION: Our study found OP was associated with a greater risk of 2-year adverse outcomes following TKA or THA, including medical, surgical, and overall complications as well as revision operations compared to non-OP patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Osteoartritis , Osteoporosis , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Osteoartritis/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Osteoporosis/complicaciones , Artroplastia de Reemplazo de Cadera/efectos adversos , Tiempo de Internación , Factores de Riesgo
6.
Phys Med ; 100: 72-80, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35759942

RESUMEN

PURPOSE: To evaluate AAPM TG-218 recommended tolerances for IMRT QA for conventional and SBRT delivery. METHODS: QA analysis was repeated for 150 IMRT/VMAT patients with varying gamma criteria. True composite delivery was utilized, corrected for detector and output variation. Universal tolerance (TLuniv) and action limits (ALuniv) were compared with statistical process control (SPC) TLSPC and ALSPC values. Analysis was repeated as a function of plan complexity for 250 non-stereotactic body radiotherapy (SBRT) VMAT patients at 3%/2mm and a threshold of 10% and for 75 SBRT VMAT patients at 2%/2 mm and a threshold of 50% with results plotted as a function of PTV volume. Regions of failure were dose-scaled on the planning CT data sets based on delivery results. RESULTS: The IMRT/VMAT TLSPC and ALSPC for gamma criteria of 3%/3 mm were 96.5% and 95.6% and for 3%/2 mm were 91.2% and 89.2%, respectively. Correlation with plan complexity for conventional fractionation VMAT was "low" for all sites with pelvis having the highest r value at -0.35. The equivalent SBRT PTV diameter ranged from 2.0 cm to 5.6 cm. Negative low correlation was found for 38 of 75 VMAT cases below ALuniv. CONCLUSIONS: The ALuniv and ALSPC are similar for 3%/2 mm. However, our 5% failure rate for ALuniv, may result in treatment start delays approximately 2 times/month, given 40 new cases/month. VMAT QA failure at stricter criteria did not correlate strongly with plan complexity. Site-specific action limits vary less than 3% from the average. SBRT QA results do not strongly correlate with target size over the range studied.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Rayos gamma , Humanos , Aceleradores de Partículas , Radiocirugia/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
7.
Iowa Orthop J ; 42(2): 60-65, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36601222

RESUMEN

Background: There exists conflicting data that patient sex may influence complication and revision rates when undergoing total hip arthroplasty (THA), specifically when comparing different surgical approaches. Differences in body fat or muscular distribution are proposed mechanisms, but these are poorly understood and not well described in current literature. Methods: A systematic review of the literature was conducted from PubMed, Embase, and Web of Science from inception of the database through September 15, 2020. Studies were included if they included patients undergoing primary elective unilateral THA, delineated infections by surgical approach, and delineated infections by patient sex. Basic science, cadaveric, and animal studies were excluded as were case reports. Two authors screened abstracts and then extracted data from the full text article. Results: Three studies, including 1,694 patients undergoing 1,811 THA were included. 80 infections were included. No study reported a statistically significant difference in infection risk by patient sex or surgical approach, though there was substantial heterogeneity in study design, approach, and analysis. Conclusion: Limited data suggests no relationship between sexes across surgical approaches for infection rates. However, poor reporting and small sample sizes preclude definitive conclusions from being drawn. Future studies should emphasize reporting differences in outcomes by patient sex to better elucidate differences, if any, in adverse outcomes between sexes following THA across surgical approaches. Level of Evidence: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Reoperación
8.
Eur J Orthop Surg Traumatol ; 32(5): 891-897, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34159480

RESUMEN

PURPOSE: To investigate the average fluoroscopy time, as well as the patient and surgical staff average radiation exposure in the context of intraoperative fluoroscopy use during anterior total hip arthroplasty (THA). METHODS: PubMed, Cochrane, Embase, Web of Science and Scopus were systematically searched for studies pertaining to intraoperative anterior THA fluoroscopy (PROSPERO ID 258049). The comprehensive literary search was conducted using "THA," "fluoroscopy" and "radiation exposure" as the search criteria, which resulted in 187 total papers. Of these 187 papers, 11 studies were included in this systematic review as they involved anterior THA and specifically contained data regarding radiation exposure dose and/or time. RESULTS: Eleven studies were included, enrolling 1839 patients. The average fluoroscopy time was 21.4 (95% confidence interval [CI] 16.6-26.1) seconds, whereas the average patient radiation dose was 1.8 × 10-3 (95% CI 7.4 × 10-4-2.9 × 10-3) Gy. CONCLUSIONS: Although several studies fail to report fluoroscopy time and radiation dose in THA patients, fluoroscopy-guided THA has emerged as a safe procedure. Additional studies may analyze if radiation exposure during the surgeon's THA learning curve is significantly higher, as well as what protocols may potentially reduce radiation exposure even further.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Exposición a la Radiación , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Fluoroscopía/efectos adversos , Humanos , Curva de Aprendizaje , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Factores de Tiempo
9.
Adv Radiat Oncol ; 6(1): 100594, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33490729

RESUMEN

PURPOSE: The purpose of this work is to present a practical, structured process allowing for consistent, safe radiation therapy delivery in the re-treatment environment. METHODS AND MATERIALS: A process for reirradiation is described with documentation in the form of a special physics consultation. Data acquisition associated with previous treatment is described from highest to lowest quality. Methods are presented for conversion to equieffective dose, as well as our departmental assumptions for tissue repair. The generation of organ-at-risk available physical dose for use in treatment planning is discussed. Results using our methods are compared with published values after conversion to biologically effective dose. Utilization of pulsed-low-dose-rate delivery is described, and data for reirradiation using these methods over the previous 5 years are presented. RESULTS: Between 2015 and 2019, the number of patients in our department requiring equieffective dose calculation has doubled. We have developed guidelines for estimation of sublethal damage repair as a function of time between treatment courses ranging from 0% for <6 months to 50% for >1 year. These guidelines were developed based on available spinal cord data because we found that 84% of organs at risk involved nerve-like tissues. The average percent repair used increased from 32% to 37% over this time period. When comparing the results obtained using our methods with published values, 99% of patients had a cumulative biologically effective dose below the limits established for acceptable myelopathy rates. Pulsed-low-dose-rate use over this period tripled with an average prescription dose of 49 Gy. CONCLUSIONS: The methods described result in safe, effective treatment in the reirradiation setting. Further correlation with patient outcomes and side effects is warranted.

10.
Phys Med ; 76: 142-149, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32679409

RESUMEN

OBJECTIVE: This work investigates the time and frequency to observe fiducial markers in MLC-modulated fields during intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) beam delivery for real-time prostate localization. METHODS: Thirty seven prostate patients treated with IMRT or VMAT were included in this retrospective study. DRR images were generated for all MLC segments/control points using the TPS. The MLC leaf pattern of each control point was overlaid on the DRR, and the number of fiducials within the MLC opening was analyzed. EPID images of fiducials in a pelvic phantom were obtained to demonstrate the fiducial visibility during modulated beam delivery. RESULTS: Gold fiducials were visible on EPID images. The probability of seeing a number of fiducials within the MLC opening was analyzed. At least one fiducial was visible during 42 ± 2% and 52 ± 2% beam-on time for IMRT of the prostate with and without lymph nodes, and during 81 ± 4% and 80 ± 5% beam-on time for VMAT of the prostate with and without lymph nodes, respectively. The mean time interval to observe at least one fiducial was 8.4 ± 0.7 and 5.9 ± 0.5 s for IMRT of the prostate with and without the lymph nodes, respectively, and 1.6 ± 0.1 s for VMAT prostate patients. The estimated potential dosimetric uncertainty was 7% and 2% for IMRT and VMAT, respectively. CONCLUSIONS: Our results demonstrated that the time and frequency to observe fiducial markers in MLC-modulated fields during IMRT/VMAT beam delivery were adequate for real-time prostate localization. The beam's eye view fiducial positions could be used for intrafractional target monitoring and motion correction in prostate radiotherapy.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Marcadores Fiduciales , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
11.
Nutr Diabetes ; 9(1): 26, 2019 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-31551412

RESUMEN

OBJECTIVES: Diabetes-specific nutritional formulas (DSNFs) are frequently used by patients with type 2 diabetes (T2D) as part of nutrition therapy to improve glycemic control and reduce body weight. However, their effects on hunger and satiety hormones when compared to an isocaloric standardized breakfast are not fully understood. This study aims to evaluate the postprandial effects of two DSNFs-Glucerna (GL) and Ultra Glucose Control (UGC)-versus oatmeal on selected satiety and hunger hormones. METHOD: After an overnight fast, 22 patients with T2D (mean age 62.3 ± 6.8 years, A1C 6.8 ± 0.7%, body weight 97.4 ± 21.3 kg, and BMI 33.2 ± 5.9 kg/m²) were given 200 kcal of each meal on three separate days. Blood samples for amylin, cholecystokinin (CCK), ghrelin, glucagon, leptin, and peptide-YY (PYY) were collected at baseline and 30, 60, 90, 120, 180, and 240 min after the start of each meal. Incremental area under the curve (iAUC0-240) for each hormone was calculated. RESULTS: iAUC0-240 for glucagon and PYY were significantly higher after GL and UGC than after oatmeal (p < 0.001 for both). No difference was observed between the three meals on postprandial amylin, CCK, ghrelin, and leptin hormones. CONCLUSIONS: Intake of DSNFs significantly increases secretion of PYY and glucagon, two important satiety hormones. While subjective satiety was not directly evaluated, the increased effect on satiety hormones may partially explain the mechanism of body weight loss associated with DSNF use.


Asunto(s)
Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/dietoterapia , Alimentos Formulados , Hambre/fisiología , Periodo Posprandial/fisiología , Saciedad/fisiología , Anciano , Glucemia , Colecistoquinina/sangre , Estudios Cruzados , Femenino , Ghrelina/sangre , Glucagón/sangre , Humanos , Polipéptido Amiloide de los Islotes Pancreáticos/sangre , Leptina/sangre , Masculino , Persona de Mediana Edad , Péptido YY/sangre
12.
J Long Term Eff Med Implants ; 28(1): 63-71, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29772995

RESUMEN

Quadriceps tendon ruptures are rare complications of total knee arthroplasty (TKA) and may be associated with preexisting tendon degeneration, vascular injuries during surgery, damage to the quadriceps tendon with over resection of the patella, or incomplete healing after a particular surgical approach. Moreover, postoperative causes include tissue necrosis due to component malalignment, trauma, and infection. Patient factors such as chronic systemic diseases, medications, increased body weight, and sedentary lifestyle could also be responsible. The number of reported cases on bilateral spontaneous quadriceps tendon ruptures is limited and cases are often not associated with TKA, but are likely associated with chronic diseases and medication use. Therefore, the purpose of the present study was to report on a patient who underwent bilateral TKA with sequential bilateral spontaneous quadriceps tendon ruptures postoperatively and to discuss their management.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Traumatismos de los Tendones/etiología , Traumatismos de los Tendones/cirugía , Anciano , Femenino , Humanos , Músculo Cuádriceps , Reoperación , Rotura Espontánea/etiología , Rotura Espontánea/cirugía
13.
Phys Med Biol ; 63(3): 035029, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29300187

RESUMEN

To compare the dosimetric parameters of a novel rotating gamma ray system (RGS) with well-established CyberKnife system (CK) for treating malignant brain lesions. RGS has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. We compared several dosimetric parameters in 10 patients undergoing brain stereotactic radiosurgery including plan normalization, number of beams and nodes for CK and shots for RGS, collimators used, estimated treatment time, D 2 cm and conformity index (CI) among two modalities. The median plan normalization for RGS was 56.7% versus 68.5% (p = 0.002) for CK plans. The median number of shots from RGS was 7.5 whereas the median number of beams and nodes for CK was 79.5 and 46. The median collimator's diameter used was 3.5 mm for RGS as compared to 5 mm for CK (p = 0.26). Mean D 2 cm was 5.57 Gy for CyberKnife whereas it was 3.11 Gy for RGS (p = 0.99). For RGS plans, the median CI was 1.4 compared to 1.3 for the CK treatment plans (p = 0.98). The average minimum and maximum doses to optic chiasm were 21 and 93 cGy for RGS as compared to 32 and 209 cGy for CK whereas these were 0.5 and 364 cGy by RGS and 18 and 399 cGy by CK to brainstem. The mean V12 Gy for brain predicting for radionecrosis with RGS was 3.75 cm3 as compared to 4.09 cm3 with the CK (p = 0.41). The dosimetric parameters of a novel RGS with a ring type gantry are comparable with CyberKnife, allowing its use for intracranial lesions and is worth exploring in a clinical setting.


Asunto(s)
Neoplasias Encefálicas/cirugía , Rayos gamma , Aceleradores de Partículas/instrumentación , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada
14.
Phys Med Biol ; 59(4): 819-36, 2014 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-24487461

RESUMEN

Electron beam therapy has been an important radiation therapy modality for many decades. Studies have been conducted recently for more efficient and advanced delivery of electron beam radiation therapy. X-ray contamination is a common problem that exists with all of the advanced electron beam therapy techniques such as Bolus Electron conformal therapy, segmented electron conformal therapy, and modulated electron arc therapy. X-ray contamination could add some limitations to the advancement and clinical utility of those electron modalities. It was previously shown in the literature that the scattering foil is one of the major accelerator parts contributing to the generation of bremsstrahlung photons. Thus, in this work we investigate the dosimetric characteristics of scattering foil free (SFF) electron beams and the feasibility of using those beams for breast cancer boosts. The SFF electron beams were modeled and simulated using the Monte Carlo method. CT scans of six previously treated breast patients were used for the treatment plan generation utilizing our in-house Monte Carlo-based treatment planning system. Electron boost plans with conventional beams and the SFF beams were generated, respectively, for all patients. A significant reduction of the photon component was observed with the removal of the primary scattering foil for beam energies higher than 12 MeV. Flatness was greatly affected but the difference in flatness between conventional and SFF beams was much reduced for small cone sizes, which were often used clinically for breast boosts. It was found that the SFF electron beams could deliver high-quality dose distributions as conventional electron beams for boost treatments of the breast with an added advantage of a further reduced dose to the lung and the heart.


Asunto(s)
Electrones/uso terapéutico , Dispersión de Radiación , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Humanos , Método de Montecarlo , Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
15.
J Appl Clin Med Phys ; 15(1): 4506, 2014 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-24423848

RESUMEN

The dosimetric advantage of modulated electron radiotherapy (MERT) has been explored by many investigators and is considered to be an advanced radiation therapy technique in the utilization of electrons. A computer-controlled electron multileaf collimator (MLC) prototype, newly designed to be added onto a Varian linac to deliver MERT, was investigated both experimentally and by Monte Carlo simulations. Four different electron energies, 6, 9, 12, and 15 MeV, were employed for this investigation. To ensure that this device was capable of delivering the electron beams properly, measurements were performed to examine the electron MLC (eMLC) leaf leakage and to determine the appropriate jaw positioning for an eMLC-shaped field in order to eliminate a secondary radiation peak that could otherwise appear outside of an intended radiation field in the case of inappropriate jaw positioning due to insufficient radiation blockage from the jaws. Phase space data were obtained by Monte Carlo (MC) simulation and recorded at the plane just above the jaws for each of the energies (6, 9, 12, and 15 MeV). As an input source, phase space data were used in MC dose calculations for various sizes of the eMLC shaped field (10 × 10 cm2, 3.4 × 3.4 cm2, and 2 × 2 cm2) with respect to a water phantom at source-to-surface distance (SSD) = 94 cm, while the jaws, eMLC leaves, and some accessories associated with the eMLC assembly as well were modeled as modifiers in the calculations. The calculated results were then compared with measurements from a water scanning system. The results showed that jaw settings with 5 mm margins beyond the field shaped by the eMLC were appropriate to eliminate the secondary radiation peak while not widening the beam penumbra; the eMLC leaf leakage measurements ranged from 0.3% to 1.8% for different energies based on in-phantom measurements, which should be quite acceptable for MERT. Comparisons between MC dose calculations and measurements showed agreement within 1%/1 mm based on percentage depth doses (PDDs) and off-axis dose profiles for a range of field sizes for each of the electron energies. Our current work has demonstrated that the eMLC and other relevant components in the linac were correctly modeled and simulated via our in-house MC codes, and the eMLC is capable of accurately delivering electron beams for various eMLC-shaped field sizes with appropriate jaw settings. In the next stage, patient-specific verification with a full MERT plan should be performed.


Asunto(s)
Electrones/uso terapéutico , Registro de la Relación Maxilomandibular/instrumentación , Método de Montecarlo , Radiometría/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Intensidad Modulada , Simulación por Computador , Diseño de Equipo , Humanos , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
16.
Phys Med Biol ; 58(16): 5653-72, 2013 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-23892910

RESUMEN

A motorized electron multileaf collimator (eMLC) was developed as an add-on device to the Varian linac for delivery of advanced electron beam therapy. It has previously been shown that electron beams collimated by an eMLC have very similar penumbra to those collimated by applicators and cutouts. Thus, manufacturing patient specific cutouts would no longer be necessary, resulting in the reduction of time taken in the cutout fabrication process. Moreover, cutout construction involves handling of toxic materials and exposure to toxic fumes that are usually generated during the process, while the eMLC will be a pollution-free device. However, undulation of the isodose lines is expected due to the finite size of the eMLC. Hence, the provided planned target volume (PTV) shape will not exactly follow the beam's-eye-view of the PTV, but instead will make a stepped approximation to the PTV shape. This may be a problem when the field edge is close to a critical structure. Therefore, in this study the capability of the eMLC to achieve the same clinical outcome as an applicator/cutout combination was investigated based on real patient computed tomographies (CTs). An in-house Monte Carlo based treatment planning system was used for dose calculation using ten patient CTs. For each patient, two plans were generated; one with electron beams collimated using the applicator/cutout combination; and the other plan with beams collimated by the eMLC. Treatment plan quality was compared for each patient based on dose distribution and dose-volume histogram. In order to determine the optimal position of the leaves, the impact of the different leaf positioning strategies was investigated. All plans with both eMLC and cutouts were generated such that 100% of the target volume receives at least 90% of the prescribed dose. Then the percentage difference in dose between both delivery techniques was calculated for all the cases. The difference in the dose received by 10% of the volume of the target was showing a mean percentage difference of 1.57%± 1.65, while the difference in the dose received by 99% of the volume was showing a mean percentage difference of 1.08%± 0.78. The mean percentage volume of Lung receiving a percentage dose equal to or greater than 20% of the prescribed dose was found to be 8.55%± 7.3 and 8.67%± 7 for the eMLC and applicator/cutout combination delivery methods respectively. Results have shown that target coverage and critical structure sparing can be effectively achieved by electron beams collimated with the eMLC. Positioning the eMLC leaves in such a way to avoids shielding any part of the projected treatment volume is most conservative and would be the recommended method to define the actual leaf position for the eMLC defined field. More optimal leaf positions can be achieved in shaping the same treatment field through the interplay of different leaf positioning strategies. We concluded that the eMLC represents an effective time saving and pollution-free device that can completely replace patient specific cutouts.


Asunto(s)
Electrones/uso terapéutico , Medicina de Precisión , Radioterapia Asistida por Computador/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Estudios de Factibilidad , Humanos , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X
17.
J Appl Clin Med Phys ; 11(2): 2913, 2010 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-20592689

RESUMEN

Modulated electron radiation therapy (MERT) has been proven as an effective way to deliver conformal dose distributions to shallow tumors while sparing distal critical structures and surrounding normal tissues. It had been shown that a dedicated electron multileaf collimator (eMLC) is necessary to reach the full potential of MERT. In this study, a manually-driven eMLC for MERT was investigated. Percentage depth dose (PDD) curves and profiles at different depths in a water tank were measured using ionization chamber and were also simulated using the Monte Carlo method. Comparisons have been performed between PDD curves and profiles collimated using the eMLC and conventional electron applicators with similar size of opening. Monte Carlo simulations were performed for all electron energies available (6, 9, 12, 15, 18 and 20 MeV) on a Varian 21EX accelerator. Monte Carlo simulation results were compared with measurements which showed good agreement (< 2%/1mm). The simulated dose distributions resulting from multiple static electron fields collimated by the eMLC agreed well with measurements. Further studies were carried out to investigate the properties of abutting electron beams using the eMLC, as it is an essential issue that needs to be addressed for optimizing the MERT outcome. A series of empirical formulas for abutting beams of different energies have been developed for obtaining the optimum gap sizes, which can highly improve the target dose uniformity.


Asunto(s)
Método de Montecarlo , Neoplasias/radioterapia , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Simulación por Computador , Electrones , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA