Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Rev. bras. cir. cardiovasc ; 37(5): 765-768, Sept.-Oct. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1407298

RESUMEN

ABSTRACT Transfemoral transcatheter aortic valve replacement (TAVR) is currently the standard catheter-based treatment of severe aortic stenosis patients. Being the transfemoral route not feasible, other access sites could be chosen. Transaortic TAVR via either a J mini-sternotomy or a right anterolateral mini-thoracotomy is a good option for patients having tricky thoracoabdominal aorta. Some tips and tricks may help in getting a fast and safe transaortic procedure.

2.
Braz J Cardiovasc Surg ; 37(4): 595-598, 2022 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-35976212

RESUMEN

Iatrogenic acute aortic dissections during percutaneous coronary interventions are an extremely rare but potentially life-threatening complication, occurring in less than 0.02% of transcatheter procedures. We report three patients with different characteristics suffering from iatrogenic aortic dissection during percutaneous coronary intervention successfully treated with an emergency open-heart surgery. A conservative strategy should be pursuit only in small, localized lesions.


Asunto(s)
Disección Aórtica , Intervención Coronaria Percutánea , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Disección Aórtica/cirugía , Vasos Coronarios/cirugía , Humanos , Enfermedad Iatrogénica , Intervención Coronaria Percutánea/efectos adversos
3.
Rev. bras. cir. cardiovasc ; 37(4): 595-598, Jul.-Aug. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1394733

RESUMEN

ABSTRACT Iatrogenic acute aortic dissections during percutaneous coronary interventions are an extremely rare but potentially life-threatening complication, occurring in less than 0.02% of transcatheter procedures. We report three patients with different characteristics suffering from iatrogenic aortic dissection during percutaneous coronary intervention successfully treated with an emergency open-heart surgery. A conservative strategy should be pursuit only in small, localized lesions.

4.
Braz J Cardiovasc Surg ; 37(5): 765-768, 2022 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-35895988

RESUMEN

Transfemoral transcatheter aortic valve replacement (TAVR) is currently the standard catheter-based treatment of severe aortic stenosis patients. Being the transfemoral route not feasible, other access sites could be chosen. Transaortic TAVR via either a J mini-sternotomy or a right anterolateral mini-thoracotomy is a good option for patients having tricky thoracoabdominal aorta. Some tips and tricks may help in getting a fast and safe transaortic procedure.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Esternotomía , Toracotomía , Válvula Aórtica/cirugía , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/métodos
5.
J Card Surg ; 37(7): 1887-1893, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35249231

RESUMEN

AIMS: In the clinical practice a noteworthy proportion of severe symptomatic aortic stenosis patients presents with low-flow low-gradients features, these having reported a less favorable prognosis even when surgically or transcatheter treated. METHODS AND RESULTS: We retrospectively analyzed the prospectively collected data on 1051 consecutive patients undergone balloon-expandable transcatheter aortic valve replacement at our Institution from January 2008 to January 2020. We divided the population according with a mean aortic gradient (MAG) < or ≥40 mmHg and we performed a propensity-matched analysis based on the Society of Thoracic Surgery Score and age, obtaining two homogeneous groups of 314 patients each (Groups A and B, respectively). We then analyzed the outcomes of the two groups by implementing adjusted Cox models adjusted for significant clinical differences between the two groups, such as sex, ejection fraction, comorbidities and other variables not included in the propensity-matched analysis. The only variable associated with both cardiovascular and all-cause events was an ejection fraction ≤35%. Finally, a sensitivity analysis found that an ejection fraction ≤35% was associated with an increase cardiovascular and all-cause mortality only in patients with an indexed end-diastolic volume >97 ml/m2 (p = .0438 and .3363, respectively). CONCLUSIONS: In our series a MAG <40 mmHg was not found to be per se an independent risk factor for cardiac and all-cause mortality after transcatheter aortic valve replacement. The ejection fraction was found to be an independent risk factor only in the context of enlarged left ventricular dimensions.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Humanos , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Función Ventricular Izquierda
6.
J Card Surg ; 37(7): 2053-2059, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35249238

RESUMEN

INTRODUCTION: The proportion of patients with symptomatic severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR) is increasing, driven by favorable outcomes from randomized trials and current valve guidelines recommendations. Despite device and technique improvements having reduced procedural morbidities, complications during or immediately after TAVR still carries significant mortality risk. METHODS: We propose a check-list of essential items to anticipate potentially life-threatening complications in TAVR. RESULTS: Purpose of this review is to discuss the most common life-threatening complications during TAVR from a troubleshooting perspective, depicting the minimum required equipment needed in emergency situations. CONCLUSIONS: Prevention of complications remains the most important strategy to optimize outcomes in TAVR procedures. Each specialized Center should institute and make easily accessible standardized emergency kits for the most common life-threatening conditions during TAVR that should be readily available in the cath-lab or hybrid operating room.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
7.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-34463727

RESUMEN

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Anciano , Anciano de 80 o más Años , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Estudios Retrospectivos , Resultado del Tratamiento
8.
Eur J Heart Fail ; 24(3): 442-454, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34894039

RESUMEN

Tricuspid regurgitation (TR) is a highly prevalent valvular heart disease and is associated with an increased risk of cardiovascular events and death at long-term follow-up. Functional TR accounts for over 90% of TR and is mainly due to annular or right ventricular dilatation. Most often, TR is observed in patients with left-sided valvular heart disease (with or without previous surgical correction) and pulmonary hypertension. Isolated TR is less frequent, though burdened by high surgical mortality. This, together with an incomplete understanding of the disease, has brought to a significant undertreatment in spite of the growing evidence of the impact of severe TR on mortality. Moreover, uncertainties about the appropriate timing for intervention and the predictors of procedural success have contributed to limit TR treatment. Transcatheter tricuspid valve replacement or repair interventions represent novel and less invasive alternatives to surgery and have shown early promising results. The purpose of this review is to provide a complete and updated overview of TR pathology with a special focus on current percutaneous treatment options, future challenges and directions.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/cirugía
9.
JACC Cardiovasc Interv ; 14(18): 2010-2021, 2021 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-34556275

RESUMEN

OBJECTIVES: The aim of this study was to determine clinical and echocardiographic characteristics, mechanisms of failure, and outcomes of mitral valve (MV) surgery after transcatheter edge-to-edge repair (TEER). BACKGROUND: Although >100,000 mitral TEER procedures have been performed worldwide, longitudinal data on MV surgery after TEER are lacking. METHODS: Data from the multicenter, international CUTTING-EDGE registry were retrospectively analyzed. Clinical and echocardiographic outcomes were evaluated. Median follow-up duration was 9.0 months (interquartile range [IQR]: 1.2-25.7 months) after MV surgery, and follow-up was 96.1% complete at 30 days and 81.1% complete at 1 year. RESULTS: From July 2009 to July 2020, 332 patients across 34 centers underwent MV surgery after TEER. The mean age was 73.8 ± 10.1 years, median Society of Thoracic Surgeons risk for MV repair at initial TEER was 4.0 (IQR: 2.3-7.3), and primary/mixed and secondary mitral regurgitation were present in 59.0% and 38.5%, respectively. The median interval from TEER to surgery was 3.5 months (IQR: 0.5-11.9 months), with overall median Society of Thoracic Surgeons risk of 4.8% for MV replacement (IQR: 2.8%-8.4%). The primary indication for surgery was recurrent mitral regurgitation (33.5%), and MV replacement and concomitant tricuspid surgery were performed in 92.5% and 42.2% of patients, respectively. The 30-day and 1-year mortality rates were 16.6% and 31.3%, respectively. On Kaplan-Meier analysis, the actuarial estimates of mortality were 24.1% at 1 year and 31.7% at 3 years after MV surgery. CONCLUSIONS: In this first report of the CUTTING-EDGE registry, the mortality and morbidity risks of MV surgery after TEER were not negligible, and only <10% of patients underwent MV repair. These registry data provide valuable insights for further research to improve these outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
10.
Circ Cardiovasc Interv ; 14(9): e010628, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34407621

RESUMEN

Mitral transcatheter therapies represent the treatment of choice for all patients deemed unsuitable for cardiac surgery. So far, the largest clinical experience has been limited to percutaneous repair techniques. However, given the complexity and heterogeneity of mitral valve anatomy and pathology, transcatheter mitral valve implantation will widen the mitral valve therapies horizon, toward a patient-tailored approach. Current data about transcatheter mitral valve implantation is still limited and, although some data are promising, there are still some issues to be addressed. This review provides a comprehensive insight into the available devices and describes potential advantages and limitations of transcatheter mitral valve implantation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
11.
J Clin Med ; 10(9)2021 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-33921996

RESUMEN

Patients with severe mitral regurgitation (MR) after myocardial infarction (MI) have an increased risk of mortality. Transcatheter mitral valve repair may therefore be a suitable therapy. However, data on clinical outcomes of patients in an acute setting are scarce, especially those with reduced left ventricle (LV) dysfunction. We conducted a multinational, collaborative data analysis from 21 centers for patients who were, within 90 days of acute MI, treated with MitraClip due to severe MR. The cohort was divided according to median left ventricle ejection fraction (LVEF)-35%. Included in the study were 105 patients. The mean age was 71 ± 10 years. Patients in the LVEF < 35% group were younger but with comparable Euroscore II, multivessel coronary artery disease, prior MI and coronary artery bypass graft surgery. Procedure time was comparable and acute success rate was high in both groups (94% vs. 90%, p = 0.728). MR grade was significantly reduced in both groups along with an immediate reduction in left atrial V-wave, pulmonary artery pressure and improvement in New York Heart Association (NYHA) class. In-hospital and 1-year mortality rates were not significantly different between the two groups (11% vs. 7%, p = 0.51 and 19% vs. 12%, p = 0.49) and neither was the 3-month re-hospitalization rate. In conclusion, MitraClip intervention in patients with acute severe functional mitral regurgitation (FMR) due to a recent MI in an acute setting is safe and feasible. Even patients with severe LV dysfunction may benefit from transcatheter mitral valve intervention and should not be excluded.

12.
J Card Surg ; 36(6): 2095-2098, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33709408

RESUMEN

Fully percutaneous transfemoral transcatheter aortic valve replacement (TF-TAVR) is currently the standard of the catheter-based treatment of severe aortic stenosis patients. Even though experience, lower delivery catheters profile and improved vascular closure devices performances have resulted in an overall reduction of both vascular and bleeding complications after TAVR, femoral pseudoaneurysm due to incomplete local hemostasis may occur, prolonging the in-hospital length of stay, causing discomfort to the patient and potentially evolving in serious consequences affecting the outcome. We report two successful percutaneous ultrasound-guided closure of both the main and secondary femoral access pseudoaneurysm.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
J Card Surg ; 35(8): 2089-2092, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32652613

RESUMEN

Multiple valve replacements are known to carry additional risk of morbidity and mortality in redo context. Currently, a transcatheter-based valve-in-valve approach could be useful in reducing potential serious consequences. On the other hand, this approach poses several technical challenges regarding the device and the procedural aspects. We present the case of a 78-year-old man who presented with symptoms of heart failure due to mitral and aortic bioprosthesis degenerations who was deemed to be at extremely high risk for a conventional redo surgery. A two-step transcatheter-based approach was planned and a transfemoral aortic valve-in-valve procedure was followed by a transapical mitral valve-in-valve implantation with a favorable early and long-term outcome.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Estenosis de la Válvula Aórtica/cirugía , Humanos , Masculino , Estenosis de la Válvula Mitral/cirugía , Grupo de Atención al Paciente , Reoperación , Volumen Sistólico , Resultado del Tratamiento
15.
J Card Surg ; 35(1): 158-162, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31730741

RESUMEN

OBJECTIVES: Morbidity associated with coronary artery bypass grafts and embolization during aortic cannulation is strongly related to patient characteristics/comorbidities, arterial cannulation site used and the shape of arterial cannulae tips. The desired features of an arterial cannula should be to mitigate the morbid effects of these cannulas and to focus on achieving higher blood flows with lower cannula pressures (CPs). MATERIALS AND METHODS: To evaluate the in vivo performance of two aortic dispersion flow cannulas: the Optiflow (Sorin Group, Italy) and EZ Glide (Edwards Lifesciences). They were evaluated for CPs, pump-flow rates (FRs), and plasma-free hemoglobin (Hb) over a 12-month period. Data were collected in a prospective, randomized (1:1), nonblinded, monocentric study with a cohort of 30 patients (optiflow group N = 15; EZ Glide group N = 15). RESULTS: The optiflow cannula was found to have decreasing CPs as the pump FRs were increased (112.3 ± 10.9 vs 131.1 ± 11.4 mm Hg; P < .001). Results indicated no significant differences between groups for increases in plasma free Hb (P = .41) and total microembolic signals counts during the period of cardiac surgery (P = .63). CONCLUSIONS: Both optiflow and EZ Glide dispersion flow arterial cannulas performed well, but the optiflow cannula demonstrated an ability to increase pump FRs with lower arterial line and CPs than the EZ Glide cannula. This implies an ability to improve peripheral perfusion while reducing cannula shear stress and the risk of endothelial damage, thereby having the potential to reduce the risk of atherosclerotic plaque dislodgement.


Asunto(s)
Arterias , Cateterismo/métodos , Anciano , Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Puente de Arteria Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad
16.
J Cardiothorac Surg ; 14(1): 208, 2019 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-31775822

RESUMEN

BACKGROUND: Redo surgery in patient who underwent aortic valve replacement with an aortic homograft can result technically challenging because of the massive calcification of the conduit. CASE PRESENTATION: We present a case of a patient who underwent open surgery on cardiopulmonary bypass assistance to implant a standard transcatheter aortic bioprosthesis through aortotomy in an off-label procedure and we discuss its safety and feasibility. CONCLUSIONS: The combination of open cardiac surgery and open trans-aortic implant of a transcatheter prosthesis may reduce the surgical risk shrinking the technical difficulties that the implantation of a standard surgical prosthesis would have given.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Insuficiencia de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Puente Cardiopulmonar , Humanos , Masculino , Trasplante Homólogo
17.
Open J Cardiovasc Surg ; 11: 1179065219853582, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31210733

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is nowadays generally accepted as the treatment of choice for high- to intermediate-risk patients with severe aortic stenosis not suitable for the standard surgical replacement. Many vascular accesses have been described for the valve delivery, comprising the common iliac artery as the arterial site of access. METHODS: From September 2008 to June 2014, 440 patients underwent TAVR at our institution. We report a series of 12 patients that have undergone TAVR via a trans-iliac (TI) retroperitoneal surgical approach and also discuss its feasibility, security, and medium-term follow-up. RESULTS: The 30-day survival rate was 92%. Only 1 local vascular access major complication occurred requiring an iliac-femoral bypass grafting with a vascular graft. Two patients experienced transient neurological ischemic attack. At 3-year follow-up, all the 11 patients were alive and well and the echocardiographic evaluation revealed good function of the prosthesis. CONCLUSIONS: The TI route seems to be feasible with a low profile of local complications. It may be a reasonable access alternative to the femoral artery and to the trans-apical approach. A broader, prospective study is advisable to gain general consensus on this approach.

20.
J Cardiothorac Surg ; 13(1): 126, 2018 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-30558628

RESUMEN

BACKGROUND: Valve thrombosis - either biological or mechanical - is proved to increase patient's morbidity and mortality. No consensus exist on the best management in such cases. CASE PRESENTATION: We report the case of a 69-year-old man presenting with a late thrombosis of a transcatheter aortic valve who was medically managed until he acutely worsened, developing myocardial ischemia and cardiogenic shock. CONCLUSION: This unlucky case raises a word of caution about the safety of a reactive management.


Asunto(s)
Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis/efectos adversos , Trombosis/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Oxigenación por Membrana Extracorpórea/métodos , Resultado Fatal , Humanos , Masculino , Falla de Prótesis/etiología , Choque Cardiogénico/etiología , Trombosis/tratamiento farmacológico , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA