Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Pers Med ; 12(4)2022 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-35455769

RESUMEN

BACKGROUND: In the multimodal breast-conserving curative therapy of some high-risk breast cancer patients, extended external beam radiotherapy (EBRT) not only to the breast but also to the supraclavicular fossa and the internal mammary chain (parasternal region (PSR)) is indicated. We report a dosimetric study on the EBRT of the breast ("B") and the breast including PSR ("B + PSR"), comparing the supine and the laterally tilted prone patient positions in free breathing. METHODS: The planning CT scans of 20 left- and 20 right-sided patients were analyzed. EBRT plans were calculated with 3D conformal EBRT (3D) and with intensity-modulated EBRT (IMRT) for "B" and "B + PSR" in the prone and supine positions. The mean and threshold doses were computed. The quality of EBRT plans was compared with an overall plan assessment factor (OPAF), comprising three subfactors, homogeneity, conformity, and radiogenic exposure of OAR. RESULTS: In the EBRT of "B", prone positioning significantly reduced the exposure of the OARs "heart" and "ipsilateral lung" and "lymphatic regions". The OPAF was significantly better in the prone position, regardless of the planning technique or the treated breast side. In the EBRT of "B + PSR", supine positioning significantly reduced the OAR "heart" exposure but increased the dose to the OARs "ipsilateral lung" and "lymphatic regions". There were no significant differences for the OPAF, independent of the irradiated breast side. Only the IMRT planning technique increased the chance of a comparatively good EBRT plan. CONCLUSION: Free breathing prone positioning significantly improves plan quality in the EBRT of the breast but not in the EBRT of the breast + PSR.

2.
Rofo ; 193(7): 778-786, 2021 Jul.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-33327031

RESUMEN

BACKGROUND: The exposure of a pregnant woman to X-rays is an event that can cause uncertainty for all concerned. This review provides guidance on how to assess such a situation and how to determine the dose to the unborn child. In general, the use of X-rays in pregnant women in radiology should be avoided. If possible, alternatives should be used, or examinations postponed to a time after the pregnancy. This review gives a summary of the procedure for determining the radiation exposure of a pregnant woman. METHOD: Based on the previous report of 2002 and the literature on prenatal radiation exposure published thereafter, the DGMP/DRG report on the procedure for the assessment of prenatal radiation exposure was adapted to the current state of science and technology. RESULTS: Typically, only relatively low radiation exposures of less than 20 mSv occur for the unborn child in X-ray diagnostics in the vast majority of cases. At these dose level the additional risk of damage to the embryo or fetus caused by the radiation is low and therefore only a rough conservative estimate using tabulated values are made. Only in a few types of examination (CT and interventional radiology) higher doses values might occur in the uterus. Instead of dose estimates (step 1 in the two-step model) in these cases the calculation of dose (step 2) are required and further action by the physician may be necessary. CONCLUSIONS: During the assessment, it is useful to initially use simple conservative estimation procedures to quickly determine whether a case falls into this large group less than 20 mSv, where there is a very low risk to the unborn child. If this is the case, the pregnant woman should be informed immediately by the doctor who performed the examination/treatment. This avoids a psychological burden on the patient. The DGMP/DRG report suggests a relatively simple, clearly structured procedure with advantages for all parties involved (physician, medical physics experts, MTRA and patient). KEY POINTS: · The DGMP/DRG report on prenatal radiation exposure describes the procedure for calculating radiation exposures and the associated risks for the unborn child.. · Using the two-step model, only a simple assessment based on the first step is necessary for most prenatal radiation exposures.. · With the given tables it is possible to estimate individual risks for the unborn child taking into account the radiation exposure.. · Only in the rare case that the first estimate results in a uterine dose larger 20 mSv a more accurate calculation is necessary.. CITATION FORMAT: · Fiebich M, Block A, Borowski M et al. Prenatal radiation exposure in diagnostic and interventional radiology. Fortschr Röntgenstr 2021; 193: 778 - 786.


Asunto(s)
Feto/efectos de la radiación , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Radiología Intervencionista , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Embarazo , Exposición a la Radiación/análisis
3.
J Nucl Med ; 62(1): 37-42, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32385164

RESUMEN

The value of interim 18F-FDG PET/CT (iPET)-guided treatment decisions in patients with diffuse large B-cell lymphoma (DLBCL) has been the subject of much debate. This investigation focuses on a comparison of the Deauville score and the change-in-SUVmax (ΔSUVmax) approach-2 methods to assess early metabolic response to standard chemotherapy in DLBCL. Methods: Of 609 DLBCL patients participating in the PET-Guided Therapy of Aggressive Non-Hodgkin Lymphomas trial, iPET scans of 596 patients originally evaluated using the ΔSUVmax method were available for post hoc assessment of the Deauville score. A commonly used definition of an unfavorable iPET result according to the Deauville score is an uptake greater than that of the liver, whereas an unfavorable iPET scan with regard to the ΔSUVmax approach is characterized as a relative reduction of the SUVmax between baseline and iPET staging of less than or equal to 66%. We investigated the 2 methods' correlation and concordance by Spearman rank correlation coefficient and the agreement in classification, respectively. We further used Kaplan-Meier curves and Cox regression to assess differences in survival between patient subgroups defined by the prespecified cutoffs. Time-dependent receiver-operating-characteristic curve analysis provided information on the methods' respective discrimination performance. Results: Deauville score and ΔSUVmax approach differed in their iPET-based prognosis. The ΔSUVmax approach outperformed the Deauville score in terms of discrimination performance-most likely because of a high number of false-positive decisions by the Deauville score. Cutoff-independent discrimination performance remained low for both methods, but cutoff-related analyses showed promising results. Both favored the ΔSUVmax approach, for example, for the segregation by iPET response, where the event-free survival hazard ratio was 3.14 (95% confidence interval, 2.22-4.46) for ΔSUVmax and 1.70 (95% confidence interval, 1.29-2.24) for the Deauville score. Conclusion: When considering treatment intensification, the currently used Deauville score cutoff of an uptake above that of the liver seems to be inappropriate and associated with potential harm for DLBCL patients. The ΔSUVmax criterion of a relative reduction in SUVmax of less than or equal to 66% should be considered as an alternative.


Asunto(s)
Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
4.
Z Med Phys ; 31(1): 58-64, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33309149

RESUMEN

A multicenter study was conducted to assess the radiation exposure of relatives and caregivers of patients suffering from castration resistant prostate cancer with bone metastases and treated with Ra-223 dichloride in an outpatient setting. As Ra-223 and most of its progeny emit alpha particles, especially the internal exposure of persons in the patient's vicinity had to be evaluated. METHODS: The external radiation was measured in distances of 1 m and 2 m. Wipe-tests were taken in the patients' homes to identify significant contaminations and evaluated by liquid scintillation counting. Samples of saliva and sweat were taken and measured using gamma spectrometry. RESULTS: The external exposure from the patients measured 10-20min post injection (p. i.) was<0.080µSv/h in median in 1 m distance (range: below decision threshold (

Asunto(s)
Cuidadores , Familia , Exposición a la Radiación/análisis , Radio (Elemento)/efectos adversos , Humanos , Exposición a la Radiación/efectos adversos
5.
Eur J Nucl Med Mol Imaging ; 45(11): 1934-1944, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29967943

RESUMEN

PURPOSE: The chemokine receptor CXCR4 is a promising target for molecular imaging of CXCR4+ cell types, e.g. inflammatory cells, in cardiovascular diseases. We speculated that a specific CXCR4 ligand, [68Ga]pentixafor, along with novel techniques for motion correction, would facilitate the in vivo characterization of CXCR4 expression in small culprit and nonculprit coronary atherosclerotic lesions after acute myocardial infarction by motion-corrected targeted PET/CT. METHODS: CXCR4 expression was analysed ex vivo in separately obtained arterial wall specimens. [68Ga]Pentixafor PET/CT was performed in 37 patients after stent-based reperfusion for a first acute ST-segment elevation myocardial infarction. List-mode PET data were reconstructed to five different datasets using cardiac and/or respiratory gating. Guided by CT for localization, the PET signals of culprit and various groups of nonculprit coronary lesions were analysed and compared. RESULTS: Ex vivo, CXCR4 was upregulated in atherosclerotic lesions, and mainly colocalized with CD68+ inflammatory cells. In vivo, elevated CXCR4 expression was detected in culprit and nonculprit lesions, and the strongest CXCR4 PET signal (median SUVmax 1.96; interquartile range, IQR, 1.55-2.31) was observed in culprit coronary artery lesions. Stented nonculprit lesions (median SUVmax 1.45, IQR 1.23-1.88; P = 0.048) and hot spots in naive remote coronary segments (median SUVmax 1.34, IQR 1.23-1.74; P = 0.0005) showed significantly lower levels of CXCR4 expression. Dual cardiac/respiratory gating provided the strongest CXCR4 PET signal and the highest lesion detectability. CONCLUSION: We demonstrated the basic feasibility of motion-corrected targeted PET/CT imaging of CXCR4 expression in coronary artery lesions, which was triggered by vessel wall inflammation but also by stent-induced injury. This novel methodology may serve as a platform for future diagnostic and therapeutic clinical studies targeting the biology of coronary atherosclerotic plaque.


Asunto(s)
Complejos de Coordinación , Regulación Neoplásica de la Expresión Génica , Movimiento , Péptidos Cíclicos , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones , Receptores CXCR4/metabolismo , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/fisiopatología , Respiración , Estudios Retrospectivos
6.
J Clin Oncol ; 36(20): 2024-2034, 2018 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-29750632

RESUMEN

Purpose Interim positron emission tomography (PET) using the tracer, [18F]fluorodeoxyglucose, may predict outcomes in patients with aggressive non-Hodgkin lymphomas. We assessed whether PET can guide therapy in patients who are treated with cyclophosphamide, doxorubicin, vincristine, and prednisone (CHOP). Patients and Methods Newly diagnosed patients received two cycles of CHOP-plus rituximab (R-CHOP) in CD20-positive lymphomas-followed by a PET scan that was evaluated using the ΔSUVmax method. PET-positive patients were randomly assigned to receive six additional cycles of R-CHOP or six blocks of an intensive Burkitt's lymphoma protocol. PET-negative patients with CD20-positive lymphomas were randomly assigned or allocated to receive four additional cycles of R-CHOP or the same treatment with two additional doses rituximab. The primary end point was event-free survival time as assessed by log-rank test. Results Interim PET was positive in 108 (12.5%) and negative in 754 (87.5%) of 862 patients treated, with statistically significant differences in event-free survival and overall survival. Among PET-positive patients, 52 were randomly assigned to R-CHOP and 56 to the Burkitt protocol, with 2-year event-free survival rates of 42.0% (95% CI, 28.2% to 55.2%) and 31.6% (95% CI, 19.3% to 44.6%), respectively (hazard ratio, 1.501 [95% CI, 0.896 to 2.514]; P = .1229). The Burkitt protocol produced significantly more toxicity. Of 754 PET-negative patients, 255 underwent random assignment (129 to R-CHOP and 126 to R-CHOP with additional rituximab). Event-free survival rates were 76.4% (95% CI, 68.0% to 82.8%) and 73.5% (95% CI, 64.8% to 80.4%), respectively (hazard ratio, 1.048 [95% CI, 0.684 to 1.606]; P = .8305). Outcome prediction by PET was independent of the International Prognostic Index. Results in diffuse large B-cell lymphoma were similar to those in the total group. Conclusion Interim PET predicted survival in patients with aggressive lymphomas treated with R-CHOP. PET-based treatment intensification did not improve outcome.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Linfoma no Hodgkin/diagnóstico por imagen , Linfoma no Hodgkin/tratamiento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Ciclofosfamida/administración & dosificación , Ciclofosfamida/efectos adversos , Supervivencia sin Enfermedad , Doxorrubicina/administración & dosificación , Doxorrubicina/efectos adversos , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Prednisona/administración & dosificación , Prednisona/efectos adversos , Pronóstico , Rituximab/administración & dosificación , Rituximab/efectos adversos , Resultado del Tratamiento , Vincristina/administración & dosificación , Vincristina/efectos adversos
7.
Eur J Nucl Med Mol Imaging ; 45(5): 824-845, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29234845

RESUMEN

Radium Ra-223 dichloride (radium-223, Xofigo®) is a targeted alpha therapy approved for the treatment of castration-resistant prostate cancer (CRPC) with symptomatic bone metastases and no known visceral metastatic disease. Radium-223 is the first targeted alpha therapy in this indication providing a new treatment option, with evidence of a significant survival benefit, both in overall survival and in the time to the first symptomatic skeletal-related event. The skeleton is the most common metastatic site in patients with advanced prostate cancer. Bone metastases are a clinically significant cause of morbidity and mortality, often resulting in bone pain, pathologic fracture, or spinal cord compression necessitating treatment. Radium-223 is selectively accumulated in the bone, specifically in areas of high bone turnover, by forming complexes with the mineral hydroxyapatite (the inorganic matrix of the bone). The alpha radiation generated during the radioactive decay of radium-223 produces a palliative anti-tumour effect on the bone metastases. The purpose of this guideline is to assist nuclear medicine specialists in evaluating patients who might be candidates for treatment using radium-223, planning and performing this treatment, understanding and evaluating its consequences, and improving patient management during therapy and follow-up.


Asunto(s)
Neoplasias Óseas/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Radio (Elemento)/uso terapéutico , Neoplasias Óseas/secundario , Europa (Continente) , Humanos , Masculino , Guías de Práctica Clínica como Asunto , Radioisótopos
8.
Adv Ther ; 34(4): 986-994, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28265811

RESUMEN

INTRODUCTION: The bone scan index (BSI) was introduced as a quantitative tool for tumor involvement in bone of patients with metastatic prostate cancer (mPCa). The computer-aided diagnosis device for BSI analysis EXINIboneBSI seems to represent technical progress for the quantitative assessment of bone involvement. But it is not yet clear if the automated BSI (aBSI) could contribute to improved evaluation of progression in patients under antiandrogens or chemotherapy in contrast to the visual interpretation and/or conventional biomarkers such as the prostate-specific antigen (PSA). METHODS: In 49 mPCa patients, bone scans were performed initially and during different therapy courses. Scans were evaluated visually and by the artificial-neural-network-based expert system EXINIboneBSI. Progression of metastatic bone involvement was defined according to the Prostate Cancer Clinical Trials Working Group 2 (PCWG2) criteria in the visual interpretation. The computer-assisted interpretation was based on different cutoff values in relative changes of the aBSI. Additionally, assessments according to bone scanning were compared to changes in the PSA value as a potential surrogate for treatment response. RESULTS: Using a sensitive cutoff value (5% or 10%) for the relative aBSI increase led to significantly increased progression determination compared to the visual interpretation of bone scans (49% and 43% vs. 27%, p < 0.001). In 63% of the cases PSA and BSI changes matched, whereas in 18% progression was only indicated by the aBSI. A relative cutoff of 5% for the aBSI decrease could reclassify 47 serial scan pairs which were visually interpreted as stable into 22 progressive and 25 remissive scans. CONCLUSION: Distinct thresholds of the relative aBSI could help to better assess disease progression in mPCa patients. Manual corrections of the BSI values are not required in most cases. The aBSI could serve as a useful additional parameter for therapy monitoring in mPCa patients in the future.


Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/secundario , Sistemas Especialistas , Neoplasias de la Próstata/patología , Anciano , Progresión de la Enfermedad , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Cintigrafía , Estudios Retrospectivos
9.
Clin Nucl Med ; 42(6): e286-e293, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28221194

RESUMEN

PURPOSE: The aims of this study were to gain mechanistic insights into prostate cancer biology using dynamic imaging and to evaluate the usefulness of multiple time-point Ga-prostate-specific membrane antigen (PSMA) I&T PET/CT for the assessment of primary prostate cancer before prostatectomy. METHODS: Twenty patients with prostate cancer underwent Ga-PSMA I&T PET/CT before prostatectomy. The PET protocol consisted of early dynamic pelvic imaging, followed by static scans at 60 and 180 minutes postinjection (p.i.). SUVs, time-activity curves, quantitative analysis based on a 2-tissue compartment model, Patlak analysis, histopathology, and Gleason grading were compared between prostate cancer and benign prostate gland. RESULTS: Primary tumors were identified on both early dynamic and delayed imaging in 95% of patients. Tracer uptake was significantly higher in prostate cancer compared with benign prostate tissue at any time point (P ≤ 0.0003) and increased over time. Consequently, the tumor-to-nontumor ratio within the prostate gland improved over time (2.8 at 10 minutes vs 17.1 at 180 minutes p.i.). Tracer uptake at both 60 and 180 minutes p.i. was significantly higher in patients with higher Gleason scores (P < 0.01). The influx rate (Ki) was higher in prostate cancer than in reference prostate gland (0.055 [r = 0.998] vs 0.017 [r = 0.996]). CONCLUSIONS: Primary prostate cancer is readily identified on early dynamic and static delayed Ga-PSMA ligand PET images. The tumor-to-nontumor ratio in the prostate gland improves over time, supporting a role of delayed imaging for optimal visualization of prostate cancer.


Asunto(s)
Ácido Edético/análogos & derivados , Oligopéptidos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Isótopos de Galio , Radioisótopos de Galio , Humanos , Ligandos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Próstata/diagnóstico por imagen , Próstata/cirugía , Prostatectomía , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Factores de Tiempo
10.
Eur Heart J ; 38(6): 436-443, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-27469371

RESUMEN

Aims: High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This study was designed to determine the feasibility and diagnostic accuracy of simultaneous imaging of inflammation with 111In-labeled white blood cells (WBCs) and myocardial perfusion with 99mTc-sestamibi, for localization of WBCs relative to the valve plane in suspected endocarditis. Methods and results: A dedicated cardiac CZT camera (Discovery 530c, GE Healthcare) was employed. Anthropomorphic thorax phantom studies were followed by clinical studies in 34 patients with suspected infection of native valves (n = 12) or implants (n = 22). Simultaneous 111In-WBC/99mTc perfusion imaging was performed, and compared with standard 111In-WBC planar scintigraphy and SPECT-CT. Phantom studies ruled out significant radioisotope crosstalk. Downscatter on 99mTc images was not observed for 111In activity as high as 2.5*99mTc activity. In patients, image quality was superior for CZT imaging vs. conventional SPECT-CT and planar scintigraphy (P < 0.01). Cadmium-zinc-telluride dual isotope imaging improved reader confidence for detection of inflammatory foci. Diagnostic accuracy based on surgery or Duke Criteria during follow-up was highest for CZT imaging (P < 0.001). Conclusion: Novel CZT SPECT technology improves the accuracy of molecular/cellular cardiac imaging. Simultaneous multi-isotope imaging with 111In and 99mTc is feasible and aids in the workup of suspected endocarditis.


Asunto(s)
Endocarditis/diagnóstico por imagen , Radioisótopos de Indio , Leucocitos , Radiofármacos , Tecnecio Tc 99m Sestamibi , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fantasmas de Imagen , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada de Emisión de Fotón Único/normas
11.
Z Med Phys ; 27(1): 49-55, 2017 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-27431973

RESUMEN

Ga-68-labeled radiotracers, particularly used for the detection of neuroendocrine tumors by means of Ga-68-DOTA-TATE or -DOTA-TOC or for the diagnosis of prostate cancer by means of Ga-68-labeled antigens (Ga 68-PSMA), become increasingly important. In addition to the high sensitivity and specificity of these radiopharmaceuticals, the short-lived radionuclide Ga-68 offers almost ideal nuclear characteristics for use in PET. Ga-68 is obtained from a germanium-gallium-generator system, so that the availability of Ga-68-labeled radiotracers is independent of an on-site-cyclotron regardless of the short half-life of Ga-68 of about 68minutes. Regarding the disposal of the radioactively contaminated waste from the preparation of the radiopharmaceutical, the eluted Ga-68 has to be considered to be additionally contaminated with its parent nuclide Ge-68. Due to this production-related impurity in combination with the short half-life of Ga-68, the radioactive waste has to be considered to be contaminated with Ge-68 and Ga-68 in radioactive equilibrium (hereafter referred to as Ge-68+). As there are no clearance levels for Ge-68+ given in the German Radiation Protection Ordinance, this work presents a method to calculate the missing value basing on a recommendation of the German Radiation Protection Commission in combination with simple geometric models of practical radiation protection. Regarding the relevant exposure scenarios, a limit value for the unrestricted clearance of Ge-68+ of 0.4 Bq/g was determined.


Asunto(s)
Radioisótopos de Galio , Residuos Radiactivos , Radiofármacos , Administración de Residuos , Humanos , Tomografía de Emisión de Positrones , Radioisótopos
12.
Nuklearmedizin ; 55(5): 177-86, 2016 Sep 26.
Artículo en Alemán | MEDLINE | ID: mdl-27417067

RESUMEN

This document describes the guideline for therapy of bone metastases with radium-223 ((223)Ra) published by the Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften in Germany (AWMF) under the auspices of the Deutsche Gesellschaft für Nuklearmedizin (DGN), Östereichische Gesellschaft für Nuklearmedizin (OGN), and Schweizerische Gesellschaft für Nuklearmedizin (SGNM). This guidance is based on an interdisciplinary consensus. These recommendations are a prerequisite for the quality management in the treatment of patients with bone metastases from prostate cancer using (223)Ra. They are aimed at guiding nuclear medicine specialists in selecting candidates to receive therapy and to deliver the treatment in a safe and effective manner. The document contains background information and definitions. It covers the rationale, indications and contraindications for therapy with (223)Ra. Essential topics are the requirements for institutions performing the therapy, which patient data have to be available prior to performance of therapy, and how treatment has to be carried out technically and organisationally. Moreover, essential elements of follow-up and aftercare are specified. As a matter of principle, the treatment inclusive aftercare has to be realised in close cooperation with the involved medical disciplines.


Asunto(s)
Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Medicina Nuclear/normas , Guías de Práctica Clínica como Asunto , Radioterapia/normas , Radio (Elemento)/uso terapéutico , Medicina Basada en la Evidencia , Alemania , Radiofármacos/normas , Radiofármacos/uso terapéutico , Radio (Elemento)/normas , Resultado del Tratamiento
13.
Z Med Phys ; 26(4): 298-303, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26341280

RESUMEN

The human eye lens appears to be more radiosensitive than previously assumed. The reduction of the limit for the dose to the lens of the eye to 20 mSv per year has been passed in the current Euratom Directives (2013). Therefore, in this work the impact of laboratory glasses and X-ray protective goggles was investigated and reciprocal attenuation factors (i.e. transmission factors) for different nuclides (Tc-99m, I-131, Y-90, F-18 and Ga-68) were determined. The radionuclides in typical geometry (syringe, applicator) were positioned at a distance of 50 cm to the eyes of four Alderson-Head-Phantoms. Different dosemeters measuring Hp(3) respective Hp(0.07) were fixed to the eyes of the phantoms, either behind the glasses or without any protection means, respectively. The mean reciprocal attenuation factors were determined to be between unity for F-18 and I-131 using laboratory glasses (no attenuation effect) and < 0.01 for Y-90 using X-ray protective goggles. All other results were between these extremes. It has been shown, that prospective doses to the lens of the eye can be reduced significantly by using appropriate radiation protection means, especially for those dose-relevant beta radiation emitting nuclides such as Y-90.


Asunto(s)
Dispositivos de Protección de los Ojos , Cristalino/efectos de la radiación , Exposición Profesional/prevención & control , Exposición a la Radiación/prevención & control , Protección Radiológica/instrumentación , Radioisótopos/análisis , Absorción de Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Lesiones Oculares/prevención & control , Humanos , Cristalino/lesiones , Medicina Nuclear/instrumentación , Medicina Nuclear/métodos , Exposición Profesional/análisis , Dosis de Radiación , Exposición a la Radiación/análisis , Traumatismos por Radiación/prevención & control , Protección Radiológica/métodos , Radiometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Z Med Phys ; 26(4): 304-310, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26702761

RESUMEN

According to recent studies, the human eye lens is more sensitive to ionising radiation than previously assumed. Therefore, the dose limit for personnel occupationally exposed to ionising radiation will be lowered from currently 150 mSv to 20 mSv per year. Currently, no data base for a reliable estimation of the dose to the lens of the eye is available for nuclear medicine. Furthermore, the dose is usually not monitored. The aim of this work was to determine dose rate constants for the quantity Hp(3), which is supposed to estimate the dose to the lens of the eye. For this, Hp(3)-dosemeters were fixed to an Alderson Phantom at different positions. The dosemeters were exposed to radiation from nuclides typically used in nuclear medicine in their geometries analog to their application in nuclear medicine, e.g. syringe or vial. The results show that the handling of high-energy beta (i.e. electron or positron) emitters may lead to a relevant dose to the lens of the eye. For low-energy beta emitters and gamma emitters, an exceeding of the lowered dose limit seems to be unlikely.


Asunto(s)
Cristalino/efectos de la radiación , Exposición Profesional/análisis , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Radioisótopos/análisis , Radiometría/métodos , Absorción de Radiación , Lesiones Oculares/prevención & control , Humanos , Medicina Nuclear/métodos , Exposición Profesional/prevención & control , Dosis de Radiación , Traumatismos por Radiación/prevención & control , Radiofármacos/análisis , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
BMC Neurol ; 14: 136, 2014 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-24950993

RESUMEN

BACKGROUND: Pathogenic autoantibodies targeting the recently identified leucine rich glioma inactivated 1 protein and the subunit 1 of the N-methyl-D-aspartate receptor induce autoimmune encephalitis. A comparison of brain metabolic patterns in 18F-fluoro-2-deoxy-d-glucose positron emission tomography of anti-leucine rich glioma inactivated 1 protein and anti-N-methyl-D-aspartate receptor encephalitis patients has not been performed yet and shall be helpful in differentiating these two most common forms of autoimmune encephalitis. METHODS: The brain 18F-fluoro-2-deoxy-d-glucose uptake from whole-body positron emission tomography of six anti-N-methyl-D-aspartate receptor encephalitis patients and four patients with anti-leucine rich glioma inactivated 1 protein encephalitis admitted to Hannover Medical School between 2008 and 2012 was retrospectively analyzed and compared to matched controls. RESULTS: Group analysis of anti-N-methyl-D-aspartate encephalitis patients demonstrated regionally limited hypermetabolism in frontotemporal areas contrasting an extensive hypometabolism in parietal lobes, whereas the anti-leucine rich glioma inactivated 1 protein syndrome was characterized by hypermetabolism in cerebellar, basal ganglia, occipital and precentral areas and minor frontomesial hypometabolism. CONCLUSIONS: This retrospective 18F-fluoro-2-deoxy-d-glucose positron emission tomography study provides novel evidence for distinct brain metabolic patterns in patients with anti-leucine rich glioma inactivated 1 protein and anti-N-methyl-D-aspartate receptor encephalitis.


Asunto(s)
Encefalitis Antirreceptor N-Metil-D-Aspartato/diagnóstico por imagen , Encefalitis Antirreceptor N-Metil-D-Aspartato/metabolismo , Química Encefálica/fisiología , Encefalitis/diagnóstico por imagen , Encefalitis/metabolismo , Glucosa/metabolismo , Proteínas/inmunología , Adulto , Anciano , Encefalitis Antirreceptor N-Metil-D-Aspartato/psicología , Autoanticuerpos/inmunología , Encefalitis/inmunología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Péptidos y Proteínas de Señalización Intracelular , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radiofármacos , Reproducibilidad de los Resultados , Estudios Retrospectivos
16.
Z Med Phys ; 24(3): 252-60, 2014 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-24560040

RESUMEN

Clearance monitor systems are used for gross gamma measurements of waste potentially contaminated with radioactivity. These measurements are to make sure that legal requirements, e.g. clearance criteria according to the german radiation protection ordinance, are met. This means that measurement results may overestimate, but must not underestimate the true values. This paper describes a pragmatic way using a calibrated Cs-137 point source to generate a conservative calibration for the clearance monitor system used in the Medizinische Hochschule Hannover (MHH). The most important nuclides used in nuclear medicine are considered. The measurement result reliably overestimates the true value of the activity present in the waste. The calibration is compliant with the demands for conservativity and traceability to national standards.


Asunto(s)
Algoritmos , Residuos Sanitarios/análisis , Medicina Nuclear/normas , Guías de Práctica Clínica como Asunto , Monitoreo de Radiación/instrumentación , Monitoreo de Radiación/normas , Residuos Radiactivos/análisis , Calibración , Alemania , Residuos Sanitarios/prevención & control , Dosis de Radiación , Residuos Radiactivos/prevención & control , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
PLoS One ; 8(3): e58152, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23516443

RESUMEN

UNLABELLED: A multi-centre trial using PET requires the analysis of images acquired on different systems We designed a multi-centre trial to estimate the value of 18F-FLT-PET to predict response to neoadjuvant chemotherapy in patients with newly diagnosed breast cancer. A calibration check of each PET-CT and of its peripheral devices was performed to evaluate the reliability of the results. MATERIAL AND METHODS: 11 centres were investigated. Dose calibrators were assessed by repeated measurements of a 68Ge certified source. The differences between the clocks associated with the dose calibrators and inherent to the PET systems were registered. The calibration of PET-CT was assessed with an homogeneous cylindrical phantom by comparing the activities per unit of volume calculated from the dose calibrator measurements with that measured on 15 Regions of Interest (ROIs) drawn on 15 consecutive slices of reconstructed filtered back-projection (FBP) images. Both repeatability of activity concentration based upon the 15 ROIs (ANOVA-test) and its accuracy were evaluated. RESULTS: There was no significant difference for dose calibrator measurements (median of difference -0.04%; min = -4.65%; max = +5.63%). Mismatches between the clocks were less than 2 min in all sites and thus did not require any correction, regarding the half life of 18F. For all the PET systems, ANOVA revealed no significant difference between the activity concentrations estimated from the 15 ROIs (median of difference -0.69%; min = -9.97%; max = +9.60%). CONCLUSION: No major difference between the 11 centres with respect to calibration and cross-calibration was observed. The reliability of our 18F-FLT multi-centre clinical trial was therefore confirmed from the physical point of view. This type of procedure may be useful for any clinical trial involving different PET systems.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Didesoxinucleósidos , Radioisótopos de Flúor , Imagen Multimodal/normas , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Análisis de Varianza , Neoplasias de la Mama/tratamiento farmacológico , Calibración , Femenino , Humanos , Imagen Multimodal/instrumentación , Control de Calidad , Reproducibilidad de los Resultados
18.
Z Med Phys ; 21(4): 266-73, 2011 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-21719263

RESUMEN

The aim of the study was to estimate the external radiation exposure emitted by the patient to his surroundings after discharge. Being in compliance with legal requirements is especially important when doing multiple therapies. To estimate the effective half-life to be used quite realistically, the individual effective half-lives for 41 patients with 52 therapies were calculated. From the resulting histogram the maximum value was determined to be 100 h. Substituting the physical half-life by this maximum effective half-life results in dose estimates, which are lower but still conservative. In addition, the analysis of dose related parameters for patients who underwent multiple therapies demonstrates that the parameters estimated for the first therapy cannot be transferred to the subsequent ones.


Asunto(s)
Neoplasias/radioterapia , Tumores Neuroendocrinos/radioterapia , Octreótido/análogos & derivados , Compuestos Organometálicos/uso terapéutico , Radiometría/métodos , Adolescente , Adulto , Anciano , Carga Corporal (Radioterapia) , Relación Dosis-Respuesta en la Radiación , Femenino , Semivida , Humanos , Masculino , Persona de Mediana Edad , Octreótido/farmacocinética , Octreótido/uso terapéutico , Compuestos Organometálicos/farmacocinética , Dispersión de Radiación , Adulto Joven
19.
Z Med Phys ; 21(4): 274-80, 2011 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-21719264

RESUMEN

During the last years angiographic Selective Internal Radiotherapy (SIRT) with (90)Y-labelled microspheres has become a common technique for the local-ablative treatment of cancer patients. SIRT is a palliative therapy concept for the treatment of liver malignancies. As a result of (90)Y-decay as ß(-)-emitter without a concomitant gamma radiation, Bremsstrahlung imaging is needed to validate the distribution achieved by radioembolisation. This article demonstrates the method of imaging through phantom measurement and shows the advantages of post-therapeutic tomography by means of a patient study. Approaches for further optimization of Bremsstrahlung imaging are discussed.


Asunto(s)
Embolización Terapéutica/métodos , Neoplasias Hepáticas/radioterapia , Cuidados Paliativos , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Radioisótopos de Itrio/uso terapéutico , Carga Corporal (Radioterapia) , Relación Dosis-Respuesta en la Radiación , Humanos , Hígado/irrigación sanguínea , Microesferas , Fantasmas de Imagen , Resultado del Tratamiento , Radioisótopos de Itrio/farmacocinética
20.
Eur J Nucl Med Mol Imaging ; 37(2): 310-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19763565

RESUMEN

PURPOSE: Since meningiomas show a high expression of somatostatin receptor subtype 2, PET with (68)Ga-DOTATOC was proposed as an additional imaging modality beside CT and MRI for planning radiotherapy. We investigated the input of (68)Ga-DOTATOC-PET/CT on the definition of the "gross tumour volume" (GTV) in meningiomas, in order to assess the potential value of this method. METHODS: Prior to radiotherapy, 42 patients with meningiomas (26 f, 16 m, mean age 55) underwent MRI and (68)Ga-DOTATOC-PET/CT examinations. HISTORY: operated n = 24, radiotherapy n = 1, operation and radiotherapy n = 8, no treatment n = 9. PET/CT and MRI data were co-registered using a BrainLAB workstation. For comparison, the GTV was defined first under consideration of CT and MRI data, then using PET data. RESULTS: 3/42 patients were excluded from the analysis (two with negative PET results, one with an extensive tumour, not precisely delineable by MRI or PET/CT). The average GTV(CT/MRI) was 22(+/-19)cm(3); GTV(PET) was 23(+/-20)cm(3). Additional GTV, obtained as a result of PET was 9(+/-10)cm(3) and was observed in patients with osseous infiltration. In some pre-treated patients there were intratumoural areas (as identified in CT/MRI) without SR-expression (7(+/-11)cm(3)). Common GTV as obtained by both CT/MRI and PET was 15(+/-14)cm(3). The mean bi-directional difference between the GTV(CT/MRI) and GTV(PET) accounted to 16(+/-15)cm(3) (93%, p < 0.001). In a subgroup of seven patients with multiple meningiomas, PET showed a total of 19 lesions; nine of them were not recognizable by CT or MRI. CONCLUSION: (68)Ga-DOTATOC-PET enables delineation of SR-positive meningiomas and delivers additional information to both CT and MRI regarding the planning of stereotactic radiotherapy. The acquisition on a PET/CT scanner helps to estimate the relation of PET findings to anatomical structures and is especially useful for detection of osseous infiltration. (68)Ga-DOTATOC-PET also allows detection of additional lesions in patients with multiple meningiomas.


Asunto(s)
Meningioma/diagnóstico por imagen , Meningioma/cirugía , Octreótido/análogos & derivados , Compuestos Organometálicos , Tomografía de Emisión de Positrones/métodos , Radiocirugia/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Estudios de Factibilidad , Humanos , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción , Cirugía Asistida por Computador/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA