Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
J Orthop Trauma ; 38(1): 49-55, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37559208

RESUMEN

OBJECTIVE: To identify technical factors associated with nonunion after operative treatment with lateral locked plating. DESIGN: Retrospective cohort study. SETTING: Ten Level I trauma centers. PATIENT SELECTION CRITERIA: Adult patients with supracondylar distal femur fractures (OTA/AO type 33A or C) treated with lateral locked plating from 2010 through 2019. OUTCOME MEASURES AND COMPARISONS: Surgery for nonunion stratified by risk for nonunion. RESULTS: The cohort included 615 patients with supracondylar distal femur fractures. The median patient age was 61 years old (interquartile range: 46 -72years) and 375 (61%) were female. Observed were nonunion rates of 2% in a low risk of nonunion group (n = 129), 4% in a medium-risk group (n = 333), and 14% in a high-risk group (n = 153). Varus malreduction with an anatomic lateral distal femoral angle greater than 84 degrees, was associated with double the odds of nonunion compared to those without such varus [odds ratio, 2.1; 95% confidence interval (CI), 1.1-4.2; P = 0.03]. Malreduction by medial translation of the articular block increased the odds of nonunion, with 30% increased odds per 4 mm of medial translation (95% CI, 1.0-1.6; P = 0.03). Working length increased the odds of nonunion in the medium risk group, with an 18% increase in nonunion per 10-mm increase in working length (95% CI, 1.0-1.4; P = 0.01). Increased proximal screw density was protective against nonunion (odds ratio, 0.71; 95% CI, 0.53-0.92; P = 0.02) but yielded lower mRUST scores with each 0.1 increase in screw density associated with a 0.4-point lower mRUST (95% CI, -0.55 to -0.15; P < 0.001). Lateral plate length and type of plate material were not associated with nonunion. ( P > 0.05). CONCLUSIONS: Malreduction is a surgeon-controlled variable associated with nonunion after lateral locked plating of supracondylar distal femur fractures. Longer working lengths were associated with nonunion, suggesting that bridge plating may be less likely to succeed for longer fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas del Fémur/cirugía , Fracturas del Fémur/etiología , Factores de Riesgo , Fijación Interna de Fracturas/efectos adversos , Placas Óseas/efectos adversos , Fémur
2.
Injury ; 52(7): 1788-1792, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33750585

RESUMEN

INTRODUCTION: Operative fixation of pelvic ring injuries is associated with a high risk of hardware failure and loss of reduction. The purpose of this study was to determine whether preoperative radiographs can predict failure after operative treatment of pelvic ring injuries and if the method of fixation effects their risk. PATIENTS AND METHODS: We conducted a retrospective cohort study of 143 patients with pelvic ring injuries treated with operative fixation at a level 1 trauma center. Preoperative radiographs were examined for the presence of the following characteristics: bilateral rami fractures, segmental or comminuted rami fractures, contralateral anterior and posterior injuries, complete sacral fracture, and displaced inferior ramus fractures. The method of fixation was classified based on the presence of anterior, posterior, or combined anterior and posterior fixation as well as whether or not posterior fixation was performed at a single or multiple sacral levels. Post-operative radiographs were examined for hardware failure or loss of reduction. RESULTS: Twenty-one patients (14.7%) demonstrated either hardware complication or fracture displacement within 6 months of surgery. Male sex was associated with a decreased risk of hardware complication (OR 0.11 [0.014, 0.86]; p=0.03). Posterior pelvic ring fixation at multiple sacral levels was associated with a decreased risk of fracture displacement (OR 0.21 [0.056, 0.83]; p=0.02). We were unable to demonstrate a significant association between preoperative radiographic characteristics and risk of hardware failure or fracture displacement. CONCLUSION: Our study demonstrates that both gender and the method of posterior fixation are associated with hardware failure or displacement.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Fijación Interna de Fracturas/efectos adversos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Masculino , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Radiografía , Estudios Retrospectivos , Sacro/diagnóstico por imagen , Sacro/cirugía
3.
Spine (Phila Pa 1976) ; 38(12): 984-90, 2013 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-23324939

RESUMEN

STUDY DESIGN: Laboratory based controlled in vivo study. OBJECTIVE: To determine the in vivo effects of oral glucosamine sulfate on intervertebral disc degeneration. SUMMARY OF BACKGROUND DATA: Although glucosamine has demonstrated beneficial effect in articular cartilage, clinical benefit is uncertain. A Centers for Disease Control report from 2009 reported that many patients are using glucosamine supplementation for low back pain, without significant evidence to support its use. Because disc degeneration is a major contributor of low back pain, we explored the effects of glucosamine on disc matrix homeostasis in an animal model of disc degeneration. METHODS: Eighteen skeletally mature New Zealand White rabbits were divided into 4 groups: control, annular puncture, glucosamine, and annular puncture + glucosamine. Glucosamine treated rabbits received daily oral supplementation with 107 mg/d (weight based equivalent to human 1500 mg/d). Annular puncture surgery involved puncturing the annulus fibrosus of 3 lumbar discs with a 16-gauge needle to induce degeneration. Serial magnetic resonance images were obtained at 0, 4, 8, 12, and 20 weeks. Discs were harvested at 20 weeks for determination of glycosaminoglycan content, relative gene expression measured by real time polymerase chain reaction, and histological analyses. RESULTS: The magnetic resonance imaging index and nucleus pulposus area of injured discs of glucosamine treated animals with annular puncture was found to be lower than that of degenerated discs from rabbits not supplemented with glucosamine. Consistent with this, decreased glycosaminoglycan was demonstrated in glucosamine fed animals, as determined by both histological and glycosaminoglycan content. Gene expression was consistent with a detrimental effect on matrix. CONCLUSION: These data demonstrate that the net effect on matrix in an animal model in vivo, as measured by gene expression, magnetic resonance imaging, histology, and total proteoglycan is antianabolic. This raises concern about this commonly used supplement, and future research is needed to establish the clinical relevance of these findings.


Asunto(s)
Suplementos Dietéticos/toxicidad , Matriz Extracelular/metabolismo , Glucosamina/toxicidad , Degeneración del Disco Intervertebral/tratamiento farmacológico , Disco Intervertebral/efectos de los fármacos , Vértebras Lumbares/efectos de los fármacos , Administración Oral , Animales , Disponibilidad Biológica , Modelos Animales de Enfermedad , Femenino , Regulación de la Expresión Génica , Glucosamina/administración & dosificación , Glucosamina/farmacocinética , Glicosaminoglicanos/metabolismo , Disco Intervertebral/metabolismo , Disco Intervertebral/patología , Degeneración del Disco Intervertebral/genética , Degeneración del Disco Intervertebral/metabolismo , Degeneración del Disco Intervertebral/patología , Vértebras Lumbares/metabolismo , Vértebras Lumbares/patología , Imagen por Resonancia Magnética , Conejos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA