Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Aging Clin Exp Res ; 35(9): 1865-1872, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37392348

RESUMEN

BACKGROUND: Postoperative delirium (POD) is a serious complication following anaesthesia and surgery and significantly influences postoperative outcome especially in the elderly population. Intraoperative music and positive suggestions influence postoperative outcomes by attenuating analgesic demand and increasing patient satisfaction. AIMS: Here, we examined the effect of intraoperative music and positive suggestions on the development of POD in aged patients undergoing transcatheter aortic valve replacement (TAVR) procedure under general anaesthesia. METHODS: For this randomized placebo-controlled study, eligible patients without cognitive deficit, indicated by a MMSE < 10 points, were anesthetized using remifentanil and sevoflurane. Anaesthetic depth was guide with bispectral index. An audiotape with positive suggestions was applied from a MP3 player via headphones. POD, pain and PONV was assessed. CAM-ICU and Nu-DESC were done twice daily for the first 5 days. RESULTS: Of 140 patients 118 patients could be analysed (57 male, 80.6 ± 5.1 years). POD was diagnosed in 16 patients (12.7%). POD was significantly more often observed in male (12, 21.1%) than in female (4, 6.6%, p = 0.02) and in patients with a low MMSE (23.6 ± 4.5 vs. 26.8 ± 2.8, p = 0.001). Anaesthetic depth did not influence the incidence of POD. Intraoperative music and suggestions did not affect the rate of POD, pain, analgesic requirement or PONV. DISCUSSION: In patients undergoing TAVR male sex and low MMSE scoring are associated with an increase in POD. CONCLUSIONS: Intraoperative music and positive suggestions do not influence the incidence of POD in this patient group. STUDY REGISTRATION: DRKS: 00024444, start of registration: 4.02.202, final registration: 17.09.2021.


Asunto(s)
Anestésicos , Delirio , Delirio del Despertar , Humanos , Masculino , Anciano , Femenino , Delirio del Despertar/prevención & control , Delirio/etiología , Delirio/prevención & control , Delirio/epidemiología , Náusea y Vómito Posoperatorios/complicaciones , Dolor , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/epidemiología
2.
J Nucl Cardiol ; 29(3): 1191-1204, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33354758

RESUMEN

BACKGROUND: We assessed the diagnostic value of FDG PET/CT in a real-world cohort of patients with surgically managed infective endocarditis (IE). METHODS: We performed a retrospective analysis of all patients hospitalized in a tertiary IE referral medical center from January 2014 to October 2018 fulfilling the following criteria: ICD-10 code for IE and OPS code for both, heart surgery and FDG PET/CT. RESULTS: Final analysis included 29 patients, whereof 28 patients had surgically proven IE. FDG PET/CT scan was true-positive in 15 patients (sensitivity (SEN) 56%) and false-negative in 12 patients. Combination of Duke criteria (DC) with FDG PET/CT scan resulted in gain of SEN for all patients with confirmed IE (SEN of DC 79% vs SEN of combination DC and FDG PET/CT 89%), driven by a relevant gain in PVE patients only (SEN of DC 78% vs SEN of combination DC and FDG PET/CT 94%). Interestingly, higher prosthesis age was observed in patients with false-negative scans. CONCLUSIONS: We found a SEN of 56% for FDG PET/CT in a real-world cohort of patients with surgically proven IE which was associated with a 16% gain of IE diagnosis in patients with PVE when combined with DC.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Endocarditis/diagnóstico por imagen , Endocarditis/cirugía , Endocarditis Bacteriana/diagnóstico , Fluorodesoxiglucosa F18 , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Estudios Retrospectivos
3.
Thorac Cardiovasc Surg ; 70(5): 377-383, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33368107

RESUMEN

BACKGROUND: Over the years, open heart surgery has become more complex, and especially reoperative surgery, more demanding. The risk of third-time or more sternotomy procedures is unclear. METHODS: We reviewed our institutional experience of 25 years based on two generations of cardiac surgeons in a German university medical center to document frequency, outcome, and complications of the various types of open heart procedures. RESULTS: Overall, we included 104 patients with a mean age of 64 ± 13 years. The EuroSCORE II (European System for Cardiac Operative Risk Evaluation) calculated an average mortality risk of 15.7 ± 15.4%. Subgroup comparison of isolated coronary artery bypass grafting (CABG), aortic valve replacement, and mitral valve replacement procedures did not delineate significantly different risk profiles except for the incidence of acute myocardial infarction, which was present in every second patient (53.3%) scheduled for CABG surgery. The time interval to previous surgery was 4.7 ± 6.3 years on average. Most frequent surgical procedures were valve operations, which were accomplished in 72 patients (69.2%), whereas coronary bypass surgery was performed in 23 patients (22.1%) only. Combined procedures were performed in 27 patients. Complex aortic arch replacement with a frozen elephant trunk procedure was necessary in six patients. Overall, 30-day survival was 81.7%. CONCLUSION: In conclusion, third-time and more sternotomy procedures offer acceptable outcome and should therefore be considered in appropriate patients.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Complicaciones Posoperatorias , Reoperación , Estudios Retrospectivos , Esternotomía/efectos adversos , Resultado del Tratamiento
4.
JACC Cardiovasc Interv ; 12(22): 2309-2316, 2019 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-31753302

RESUMEN

OBJECTIVES: This study reports an international experience using the transfemoral ACURATE neo transcatheter heart valve (Boston Scientific, Marlborough, Massachusetts) for the treatment of degenerated surgical aortic bioprostheses. BACKGROUND: Transcatheter valve-in-valve procedures have emerged as an alternative to redo surgery. Supra-annular prostheses might be particularly useful in this indication. METHODS: This is an international multicenter analysis including 85 patients from 14 centers in Europe and Canada undergoing an ACURATE neo valve-in-valve procedure from March 2015 to February 2019. RESULTS: Internal diameter of the degenerated bioprosthesis was 20.3 ± 2.1 mm. Prosthesis size S was used in 70 (82%) procedures. The median depth of implantation was 3 mm and the upper crown of the ACURATE neo was positioned above the stent posts of the degenerated bioprosthesis in 54 (64%) and inside in 31 (36%). Mean transvalvular gradient before discharge was significantly lower if the upper crown was above the degenerated bioprosthesis (13.7 ± 5.9 mm Hg vs. 19.5 ± 10.0 mm Hg; p = 0.001). However, a high position of the ACURATE neo resulted in embolization in 1 patient, conversion to open-heart surgery in 1, and need for reintervention due to transcatheter heart valve failure within the first 18 months of follow-up in 4. CONCLUSIONS: This early experience shows that a high implantation of the ACURATE neo with the upper crown above the stent posts of the degenerated bioprosthesis resulted in lower mean transvalvular gradients but a higher rate of malpositioning and early valve degeneration.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Stents , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Canadá , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Masculino , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Eur Heart J ; 40(38): 3156-3165, 2019 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-31230081

RESUMEN

AIMS: Peri-procedural transcatheter valve embolization and migration (TVEM) is a rare but potentially devastating complication of transcatheter aortic valve implantation (TAVI). We sought to assess the incidence, causes, and outcome of TVEM in a large multicentre cohort. METHODS AND RESULTS: We recorded cases of peri-procedural TVEM in patients undergoing TAVI between January 2010 and December 2017 from 26 international sites. Peri-procedural TVEM occurred in 273/29 636 (0.92%) TAVI cases (age 80.8 ± 7.3 years; 53.8% female), of which 217 were to the ascending aorta and 56 to the left ventricle. The use of self-expanding or first-generation prostheses and presence of a bicuspid aortic valve were independent predictors of TVEM. Bail-out measures included repositioning attempts using snares or miscellaneous tools (41.0%), multiple valve implantations (83.2%), and conversion to surgery (19.0%). Using 1:4-propensity matching, we identified a cohort of 235 patients with TVEM (TVEMPS) and 932 patients without TVEM (non-TVEMPS). In the matched cohort, all-cause mortality was higher in TVEMPS than in non-TVEMPS at 30 days (18.6% vs. 4.9%; P < 0.001) and after 1 year (30.5% vs. 16.6%; P < 0.001). Major stroke was more frequent in TVEMPS at 30 days (10.6% vs. 2.8%; P < 0.001), but not at 1 year (4.6% vs. 1.9%; P = 0.17). The need for emergent cardiopulmonary support, major stroke at 30 days, and acute kidney injury Stages 2 and 3 increased the risk of 1-year mortality, whereas a better renal function at baseline was protective. CONCLUSION: Transcatheter valve embolization and migration occurred in approximately 1% and was associated with increased morbidity and mortality.


Asunto(s)
Embolia , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Embolia/epidemiología , Embolia/etiología , Embolia/mortalidad , Femenino , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Falla de Prótesis/efectos adversos , Falla de Prótesis/etiología , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Resultado del Tratamiento
6.
Circulation ; 139(16): 1865-1871, 2019 04 16.
Artículo en Inglés | MEDLINE | ID: mdl-30732456

RESUMEN

BACKGROUND: The 30-day and 1-year follow-up analysis of the GOPCABE trial (German Off-Pump Coronary Artery Bypass Grafting in Elderly Patients) revealed no significant difference in the composite end point consisting of death, stroke, myocardial infarction, new renal replacement therapy, or repeat revascularization. The 5-year follow-up data of this trial are reported here. METHODS: From June 2008 to September 2011, a total of 2539 patients aged ≥75 years were randomly assigned to undergo off-pump or on-pump coronary artery bypass grafting (CABG) at 12 centers in Germany. The primary outcome was all-cause mortality at 5 years. The secondary 5-year outcomes were a composite of death, myocardial infarction, and repeat revascularization. Furthermore, the impact of complete versus incomplete revascularization was assessed. RESULTS: After a median follow-up of 5 years, 361 patients (31%) assigned to off-pump CABG and 352 patients (30%) assigned to on-pump CABG had died (hazard ratio off-pump/on-pump CABG, 1.03; 95% CI, 0.89-1.19; P=0.71). The composite outcome of death, myocardial infarction, and repeat revascularization occurred in 397 (34%) after off-pump and in 389 (33%) after on-pump CABG (hazard ratio, 1.03; 95% CI, 0.89-1.18; P=0.704). Incomplete revascularization occurred in 403 (34%) patients randomly assigned to off-pump and 354 (29%) patients randomly assigned to on-pump CABG ( P<0.001). Five-year survival rates were 72% (95% CI, 67-76) with incomplete versus 76% (95% CI, 74-80) with complete revascularization (log-rank test: P=0.02) after off-pump CABG and 72% (95% CI, 67-76) versus 77% (95% CI, 74-80) after on-pump CABG (log-rank test: P=0.03), respectively. Cox regression analysis revealed a hazard ratio incomplete/complete revascularization of 1.19 (95% CI, 1.01-1.39; P=0.04). CONCLUSIONS: In elderly patients ≥75 years of age, the 5-year survival rates and the combined outcome of death, myocardial infarction, and repeat revascularization, as well, were similar after on-pump and off-pump CABG. Incomplete revascularization was associated with a lower 5-year survival rate, irrespective of the type of surgery. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00719667.


Asunto(s)
Puente de Arteria Coronaria , Corazón Auxiliar , Infarto del Miocardio/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
7.
Interact Cardiovasc Thorac Surg ; 28(4): 559-565, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30380069

RESUMEN

OBJECTIVES: Preoperative computed tomography (CT) scans for transcatheter aortic valve implantation (TAVI) are used routinely. In elderly high-risk patients, incidental radiographic findings are frequently reported. The aim of this study was to investigate the impact of auxiliary findings on the patients' mid-term survival, which might affect the treatment strategy. METHODS: Between March 2011 and April 2016, all radiological reports of contrast-enhanced CT scans of 976 patients scheduled for TAVI were analysed retrospectively for incidental thoracic findings including solitary pulmonary nodules (SPN) and thoracic lymphadenopathy (LAP). The minimum follow-up period was 1 year after TAVI. RESULTS: The median age of all patients was 79 years; 51.9% (n = 507) were women. Approximately 37% (n = 361) of patients showed 1 of the determined findings. An SPN ≥5 mm was diagnosed in 16.4% (n = 160) of patients. Four of them developed lung cancer and 2 nodules were identified as metastases during follow-up. In addition, 12% (n = 117) of the patients had thoracic LAP. Whereas SPN had no significant effect on the overall survival rate, evidence of LAP turned out to be a statistically significant factor regarding 4-year survival (P = 0.001; hazard ratio 1.66; 95% confidence internal 1.19-2.31). CONCLUSIONS: SPN ≥5 mm were detected in 16.4% of patients scheduled for TAVI. Nevertheless, the incidence of lung cancer was low and the effect on survival in this high-risk group of patients was statistically not significant. In contrast, thoracic LAP had a significant negative effect on survival. It needs to be proven if the outcome of this cohort can be enhanced by further diagnostics and therapy.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hallazgos Incidentales , Neoplasias Pulmonares/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Incidencia , Neoplasias Pulmonares/epidemiología , Masculino , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Nódulo Pulmonar Solitario/epidemiología , Tasa de Supervivencia , Tomografía Computarizada por Rayos X
8.
JACC Cardiovasc Interv ; 11(14): 1368-1374, 2018 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-30025731

RESUMEN

OBJECTIVES: The SAVI-TF (Symetis ACURATE neo Valve Implantation Using Transfemoral Access) registry was initiated to study the ACURATE neo transcatheter heart valve in a large patient population treated under real-world conditions. BACKGROUND: The self-expanding, supra-annular ACURATE neo prosthesis is a transcatheter heart valve that gained the Conformité Européene mark in 2014, but only limited clinical data are available so far. METHODS: This prospective, multicenter registry enrolled 1,000 patients at 25 European centers who were followed for 1 year post-procedure. RESULTS: Mean patient age was 81.1 ± 5.2 years; mean logistic European System for Cardiac Operative Risk Evaluation I score, European System for Cardiac Operative Risk Evaluation II score, and Society of Thoracic Surgeons score were 18.1 ± 12.5%, 6.6 ± 7.5%, and 6.0 ± 5.6%, respectively. At 1 year, 8.0% (95% confidence interval [CI]: 6.3% to 9.7%) of patients had died, 2.3% (95% CI: 1.3% to 3.2%) had disabling strokes, and 9.9% (95% CI: 8.1% to 11.8%) had permanent pacemaker implantations. Through 1 year, 5 reinterventions (0.5%; 95% CI: 0.1% to 1.0%) were performed: 3 valve-in-valve and 2 surgical aortic valve replacements. Mean effective orifice area was 1.84 ± 0.43 cm2, mean gradient was 7.3 ± 3.7 mm Hg, and greater than mild paravalvular leakage was observed in 3.6% of patients. CONCLUSIONS: Transfemoral implantation of the ACURATE neo prosthesis resulted in favorable 1-year clinical and echocardiographic outcomes with very low mortality and new pacemaker rates.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Bioprótesis , Calcinosis/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Estimulación Cardíaca Artificial , Europa (Continente) , Femenino , Hemodinámica , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
Eur J Cardiothorac Surg ; 54(4): 762-767, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-29554265

RESUMEN

OBJECTIVES: We assessed the safety and efficacy of a novel low-profile, 22-Fr transapical delivery system together with the ACURATE neo™ resheathable transcatheter heart valve. METHODS: This prospective, single-arm, multicentre study enrolled 60 patients with severe symptomatic aortic stenosis and high surgical risk ineligible for transfemoral access. Primary end points were 6-month mortality and procedural success. RESULTS: The mean age of patients was 79.8 ± 4.7 years, and the patients had severe comorbidities including coronary artery disease (71.7%), diabetes (38.3%), atrial fibrillation (30.0%) and chronic obstructive pulmonary disease (21.7%); logistic EuroSCORE-I, -II and the Society of Thoracic Surgeons (STS) scores were 20.9 ± 8.9%, 6.1 ± 5.0% and 4.3 ± 2.9%, respectively. A non-rib spreading approach using soft tissue retractors only was used in 88.3% of patients (n = 53). Resheathing and repositioning of transcatheter heart valve were performed in 6.7% of cases (n = 4); the device implantation time was 3 ± 2 min. Apical access site complications occurred in 1.7% (n = 1). Procedural success was 98.3% (n = 59), and procedural success in the absence of major adverse cardiac and cerebrovascular events at 30 days was 90.0% (n = 54). At 30 days, cardiovascular and overall mortality were 8.3% (n = 5), stroke rate was 1.7% (n = 1), and 17.2% of patients (n = 10) received a permanent pacemaker implant. No paravalvular leakage ≥2+ was observed, and the mean transvalvular gradient was 5.9 ± 2.7 mmHg. At 6 months, survival was 84.3% with sustained haemodynamic results. CONCLUSIONS: This study indicates safety and efficacy of transapical aortic valve implantation using a novel low-profile delivery system. High procedural success, short implantation times and a low rate of apical access site complications underline the favourable safety profile and ease of use. Clinical trial registration: ClinicalTrials.gov: NCT02950428.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
10.
Thorac Cardiovasc Surg ; 66(6): 464-469, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29566406

RESUMEN

BACKGROUND: Coronary artery bypass grafting (CABG) without cardiopulmonary bypass (off-pump CABG) may reduce severe adverse events including stroke. METHODS: In the German Off-Pump Coronary Artery Bypass Grafting in Elderly patients trial, the rate of major adverse cardiovascular events was compared in 2,394 elderly (≥ 75 years) patients undergoing CABG with (on-pump) or without (off-pump) cardiopulmonary bypass. This exploratory post-hoc analysis investigated the impact of surgical aortic manipulation on the rate of stroke. RESULTS: There was no significant difference in the rate of stroke within 30 days after surgery between both groups (off-pump: 2.2%; on-pump: 2.7%; odds ratio [OR]: 0.83 [0.5-1.38]; p = 0.47). Within the off-pump group, different degrees of aortic manipulation did not lead to significant different stroke rates (tangential clamping: 2.3%; OR 0.86 [0.46-1.60]; clampless device: 1.8%; OR 0.67 [0.26-1.75]; no aortic manipulation: 2.4%; OR 0.88 [0.37-2.14]). An aggregate analysis including more than 10,000 patients out of the four recent major trials also yielded comparable stroke rates for on- and off-pump CABG (off-pump: 1.4%; on-pump: 1.7%; OR 0.87 [0.64-1.20]). CONCLUSION: Within recent prospective randomized multicenter trials off-pump CABG did not result in lower stroke rates. The possible intrinsic benefit of off-pump CABG may be offset by the complexity of the operative therapy as well as the multiple pathomechanisms involved in perioperative stroke.


Asunto(s)
Puente Cardiopulmonar/efectos adversos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Proyectos de Investigación , Accidente Cerebrovascular/etiología , Factores de Edad , Anciano , Puente Cardiopulmonar/mortalidad , Distribución de Chi-Cuadrado , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/mortalidad , Puente de Arteria Coronaria Off-Pump/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Alemania , Humanos , Masculino , Oportunidad Relativa , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 92(1): 149-156, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29130616

RESUMEN

BACKGROUND: Although the incidence of periprocedural complications has decreased in transcatheter aortic valve implantation (TAVI), life-threatening complications occur and emergency veno-arterial extracorporeal membrane oxygenation (vaECMO) can provide immediate circulatory stabilization. We report our two-center experience of vaECMO during life-threatening complications in TAVI. METHODS: From January 2010 to December 2015, 1,810 consecutive patients underwent TAVI at two centers. Clinical characteristics, type of complication, outcome and temporal trends in the requirement of emergency vaECMO were evaluated. RESULTS: Life-threatening complications requiring vaECMO occurred in 1.8% of cases (33 patients; 22 transfemoral, 11 transapical). Indications for vaECMO were ventricular rupture (30%, 10/33), low output (15%, 5/33), bleeding (12%, 4/33), coronary artery impairment (9%, 3/33), ventricular arrhythmias (6%, 2/33), severe aortic regurgitation (6%, 2/33), aortic annular rupture (6%, 2/33), and aortic dissection (3%, 1/33). In 4 cases, no definite cause for hemodynamic instability was identified. Conversion to open heart surgery was necessary in 42% of patients (14/33). Percutaneous coronary intervention was performed in all cases with coronary artery impairment (9%, 3/33). Patients with severe aortic regurgitation (6%, 2/33) underwent emergency valve-in-valve implantation. Other patients received, in addition to vaECMO support conservative treatment (42%, 14/33). In-hospital mortality and 30-day mortality were 46% (15/33). Of patients discharged, 67% (12/18) had no neurological impairment, whereas mild and severe neurological impairment was found in 11% (2/18) and 22% (4/18), respectively. From 2010 to 2015, with increasing procedures (from n = 43 to n = 553) requirement of vaECMO decreased from 9.3% to 0.9% (P for the trend <0.001). CONCLUSION: Over a 6-year period, need for emergency vaECMO during TAVI significantly decreased over time. Despite high in-hospital mortality, vaECMO represents a feasible strategy for hemodynamic support in case of life-threatening complications.


Asunto(s)
Válvula Aórtica/cirugía , Oxigenación por Membrana Extracorpórea , Enfermedades de las Válvulas Cardíacas/cirugía , Complicaciones Posoperatorias/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Urgencias Médicas , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Alemania , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Mortalidad Hospitalaria , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
12.
EuroIntervention ; 13(15): e1764-e1770, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29131801

RESUMEN

AIMS: The aim of the SAVI TF registry was to assess the safety and performance of the self-expanding ACURATE neo transfemoral transcatheter heart valve in a large patient population with severe aortic stenosis and to investigate whether the outcomes obtained in the CE-mark cohort can be replicated in an unselected all-comers population. METHODS AND RESULTS: From October 2014 until April 2016, 1,000 patients were enrolled in this prospective, European multicentre registry. Patients were 81.1±5.2 years and had a logistic EuroSCORE II and STS score of 6.6±7.5% and 6.0±5.6%, respectively. Predilatation was performed in 96.1% of patients and postdilatation in 44.8%. Procedural and device success were both obtained in 98.7%; failure comprised nine valve-in-valve procedures, three conversions to surgery, and one aborted procedure. The primary endpoint was 30-day mortality, which was observed in 14 patients (1.4% [95% CI: 0.7-2.1]). Disabling stroke was seen in 1.2% (95% CI: 0.5-1.9) and new pacemaker implantation in 8.3% (95% CI: 6.6-10.0). At discharge, mean effective orifice area was 1.77±0.46 cm² and mean gradient 8.4±4.0 mmHg; 4.1% of patients had a more than mild paravalvular leak. CONCLUSIONS: In this initial experience, treatment with the ACURATE neo prosthesis resulted in good clinical outcomes with very low complication rates.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Valvuloplastia con Balón , Estimulación Cardíaca Artificial , Cateterismo Periférico/métodos , Evaluación de la Discapacidad , Europa (Continente)/epidemiología , Femenino , Arteria Femoral , Humanos , Masculino , Marcapaso Artificial , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
13.
Eur J Cardiothorac Surg ; 51(5): 936-942, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28175264

RESUMEN

OBJECTIVES: The ACURATE TA TM system is a self-expanding transcatheter heart valve system designed for transapical access which has been proven to be safe and effective in the controlled setting of clinical trials. The SAVI-1 and SAVI-2 registries aimed to assess whether these promising outcomes can be translated into all-comers clinical routine. METHODS: From November 2011 to 2012 (SAVI-1), and November 2013 to 2014 (SAVI-2), a total of 500 patients were enrolled in the prospective, all-comers, multicentre, multinational SAVI registries. Patients were treated according to the standard of care at their respective hospitals. We report and compare 30-day and 1-year clinical outcomes between SAVI-1 and -2. RESULTS: Patients were 80.8 ± 6.1 years old, the mean logistic EuroSCORE-I was 23.4 ± 14.3%. Valves were deployed under rapid pacing in 71.3% of the procedures in SAVI-1, and in 3.6% in SAVI-2. There was no relevant difference in clinical and echocardiographic outcomes between SAVI-1 and SAVI-2. Overall mortality at 30 days and 1 year was 6.8% and 19.9%, the stroke rate was 2.2% and 3.7%, respectively; 10.2% of patients had received a permanent pacemaker, and no transcatheter valve-related complications after discharge were observed. Paravalvular leakage ≥2+ was reported in 1.9% of the patients at the early follow-up, and in 2.6% at the 1-year follow-up. CONCLUSIONS: The SAVI-registries have confirmed that transapical implantation using the ACURATE TA TM device is safe and effective in an all-comers setting with low complication rates and stable performance outcomes at short-term and 1 year; outcomes were similar between SAVI-1 and -2.


Asunto(s)
Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Resultado del Tratamiento
14.
Rev Esp Cardiol (Engl Ed) ; 70(3): 186-193, 2017 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-27623490

RESUMEN

INTRODUCTION AND OBJECTIVES: Conventional risk scores have not been accurate in predicting peri- and postprocedural risk of patients undergoing transcatheter aortic valve implantation (TAVI). Elevated levels of the tumor marker carbohydrate antigen 125 (CA125) have been linked to adverse outcomes after TAVI. We studied the additional value of CA125 to that of the EuroSCORE in predicting long-term mortality after TAVI. METHODS AND RESULTS: During a median follow-up of 59 weeks, 115 of 422 patients (27%) died after TAVI. Mortality was higher with elevated CA125 (> 30 U/mL) and EuroSCORE (> median) (47% vs 20%, P<.001 and 38% vs 16%, P<.001, respectively). In the multivariable analysis, CA125 (> 30 U/mL) remained an independent predictor of mortality (hazard ratio [HR], 2.16; 95% confidence interval [95%CI], 1.48-3.15; P<.001) and improved the predictive capability of the model (C-statistic: 0.736 vs 0.731) and the net reclassification index (51% 95%CI, 33-73) with an integrated discriminative improvement of 3.5% (95%CI, 0.5-8.4). A new variable (CA125-EuroSCORE) was created, with the combinations of the 2 possible binary states of these variables (+, elevated, -, not elevated; C1: CA125- EuroSCORE-; C2: CA125+ EuroSCORE-; C3: CA125- EuroSCORE+; C4: CA125+ EuroSCORE+). Patients in C1 exhibited the lowest cumulative mortality rate (14% [26 of 181]). Mortality was intermediate for C2 (CA125 > 30 U/mL and EuroSCORE ≤ median) and C3 (CA125 ≤ 30 U/mL and EuroSCORE > median): 27% (8 of 30) and 28% (37 of 131), respectively. Patients in C4 (CA125 > 30 U/mL and EuroSCORE > median) exhibited the highest mortality (55% [44 of 80], P-value for trend<.001). CONCLUSIONS: CA125 offers additional prognostic information beyond that obtained by the EuroSCORE. Elevation of both markers was associated with a poor prognosis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Antígeno Ca-125/metabolismo , Proteínas de la Membrana/metabolismo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Humanos , Masculino , Pronóstico , Estudios Prospectivos , Medición de Riesgo/métodos , Índice de Severidad de la Enfermedad
15.
Eur J Cardiothorac Surg ; 48(6): 879-85; discussion 885-6, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25825262

RESUMEN

OBJECTIVES: We demonstrate a multislice computed tomography (MSCT)-based method to calculate the prediction of the so-called 'line of perpendicularity' (LOP) and the 'implanter's views' (IVs) for transcatheter aortic valve implantation (TAVI) procedures. The LOP represents all possible angiographic angulations that result in an orthogonal view to the aortic annulus plane. The IVs allow visual confirmation of correct implantation planes, and are crucial for the commissural aligned implantation of second-generation TAVI prostheses. METHODS: The LOP and IVs of 335 concomitant patients were prospectively analysed using multiple plane reconstruction (MPR) of the patient's MSCT scans. Exclusion criteria were bicuspid valves (n = 18) and valve-in-valve TAVI (n = 15). In the MPRs, the aortic cusps' lowest points were marked. With the marker's three-dimensional coordinates, the graph of the LOP with the IVs was calculated and plotted using vector mathematics. In the last 244 cases, the IV with the right coronary cusp in front was chosen for the first aortic root angiogram of the TAVI procedure. The finally used angulation was confirmed by aortic angiogram prior to the valve implantation. Solid angle differences that show the combined left anterior oblique/right anterior oblique and cranio/caudal movement of the C-arm allow quantification of corrections as well as demonstrate interindividual variations. RESULTS: There is a broad interindividual variation of the aortic valve's topology with solid angle variations of up to 74°. The shape of the LOPs is extremely varying, especially regarding the slope of the curve that indicates differences in valve orientations. Among the 244 patients for whom we used the prediction for the procedure, the first angiogram was considered perfect for implantation without further corrections in 97% (n = 237) of them. In case of the 7 patients with subsequent corrections, the mean solid angle between the prediction and the final angiogram prior to implantation was 6.2° (±5°); the largest correction was 14°. CONCLUSIONS: Prediction of the implantation plane by analysing the patient's MSCT is highly reliable in achieving an adequate view of the aortic annulus in TAVI. The analysis of LOPs showed the large interindividual differences that permit using a standard implantation plane. Therefore, we strongly recommend determining the LOP and IVs during the patient's screening process in each single TAVI case.


Asunto(s)
Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/anatomía & histología , Fluoroscopía , Humanos , Tomografía Computarizada Multidetector/métodos
16.
Ann Thorac Surg ; 99(5): 1532-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25661576

RESUMEN

BACKGROUND: Transcatheter valve-in-valve (VIV) implantation evolved as a therapeutic alternative, despite an increased risk of coronary obstruction in comparison with a regular transcatheter aortic valve implantation (TAVI). We report a comprehensive single-institution experience emphasizing strategies to reduce the risk of myocardial ischemia. METHODS: Since 2009, 639 patients underwent a TAVI procedure in our institution. All patients are prospectively collected into an institutional registry. In total 31 patients underwent a VIV procedure at our institution (age 77.8 ± 6.3 years; The Society or Thoracic Surgeons predicted risk of mortality 20.9% ± 8.8%; New York Heart Association (NYHA) 3.0 ± 0.6). Degenerated bioprostheses included 24 Mitroflow, 6 Edwards Perimount, and Cryo-Valve O' Brien with label sizes from 21 to 27 mm. The type of failure was mostly regurgitation with or without concomitant stenosis (78%). RESULTS: Patients were provided with 5 Medtronic CoreValves, 15 Edwards SapienXT, 1 Edwards Sapien 3, 7 Medtronic Engager, and 3 Symetis Acurate TA valves. The procedural success rate was 88%. The left main stem was occluded in 1 patient (Sapien XT 26 in a Mitroflow 25 mm) who underwent emergent revascularization. Two patients suffering from a degenerated Mitroflow prosthesis needed a second valve (Sapien XT). Two patients with a degenerated Mitroflow prosthesis treated with a Sapien XT developed postprocedural myocardial ischemia and deceased on postoperative days 1 and 2, accounting to an overall incidence of coronary insufficiency associated to the VIV procedure of 10%. With the introduction of valves allowing commissural alignment (Acurate TA) and leaflet capturing as well (Engager) no further coronary insufficiency occurred. The mean gradient decreased significantly from 39.3 ± 14.0 to 16.1 ± 7.2 mm Hg (p = 0.002). Post-procedural regurgitation was classified as trace in 7 patients (23%) and moderate in 4 patients (13%). The 30-day survival was 77% with a significantly improved NYHA class of 1.79 ± 0.58 (p = 0.001). CONCLUSIONS: Jeopardizing coronary blood flow is likely in stenotic and calcified bioprostheses, particularly in tubelike aortic sinuses. Planning, imaging, and the use of valves allowing commissural alignment as well as leaflet capturing seem to reduce the risk. Further studies are necessary to support this hypothesis.


Asunto(s)
Bioprótesis , Oclusión Coronaria/prevención & control , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Cateterismo Cardíaco , Oclusión Coronaria/etiología , Femenino , Humanos , Masculino , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Interact Cardiovasc Thorac Surg ; 20(1): 74-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25273036

RESUMEN

OBJECTIVES: Patients undergoing coronary bypass grafting (CABG) are at higher risk if they suffer from atrial fibrillation (AF). It was suggested that performing CABG without the use of cardiopulmonary bypass (off-pump) would reduce perioperative risk. We assessed the influence of preoperative AF on outcome in a randomized cohort of patients above the age of 75 undergoing either on-pump or off-pump CABG. METHODS: The German Off-Pump Coronary Artery Bypass grafting in the Elderly trial, a randomized, controlled multicentre trial conducted at 12 German institutions, enrolled 2303 patients between 2008 and 2011. The presence of AF was recorded at admission and discharge. There was no record on the rhythm status during hospital stay. RESULTS: AF at admission was present in 5% in the on-pump (121/1158) and 5% in the off-pump (112/1145) group. The number of patients with AF at discharge was not different between these two groups (10% on pump, 10% off pump). As expected, AF patients had worse preoperative conditions, which had a negative impact on outcome: The combined end-point of death, infarction, stroke, dialysis and revascularization occurred more often (13 vs 8%, P = 0.008) and 30-day mortality was significantly higher (6 vs 2%, P = 0.003) in AF patients. However, the operative technique used for CABG did not affect these outcome parameters. CONCLUSIONS: AF at admission is a significant risk factor for elderly patients undergoing coronary bypass grafting. However, this risk is not altered by performing bypass grafting off pump.


Asunto(s)
Fibrilación Atrial/complicaciones , Puente de Arteria Coronaria Off-Pump , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Puente Cardiopulmonar , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria Off-Pump/mortalidad , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Alemania , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
J Cardiothorac Surg ; 9: 143, 2014 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-25185963

RESUMEN

BACKGROUND: Objective of this study was to evaluate the impact of age on comparative early outcomes after coronary artery bypass graft surgery (CABG) with minimized (MECC) and conventional extracorporeal circulation (CECC). METHODS: A retrospective age-, gender- and operation-matched cohort analysis between January 2005 and December 2010 with a total of 2274 patients undergoing CABG with MECC (n = 1137; 50%) or CECC was performed. Patients were stratified into 4 groups according to age: <59 years, 60-69 years, 70-79 years, and 80 years of age or older. Outcomes were compared within each age group. Patients with preoperative dialysis were excluded from analysis. Primary endpoint was 30-day mortality. RESULTS: Patients treated with CECC had a significantly higher mean logistic EuroSCORE (6.3% vs. 5.0%; p < 0.001), a slightly lower rate of preoperative myocardial infarction (46% vs. 51%; p = 0.01) and a higher rate of impaired renal function (eGFR < 60 mL/min/1.73 m2: 24% vs. 20%; p = 0.01) compared to MECC-patients. Left internal mammary artery was significantly used more often in MECC patients (93% vs. 86%; p < 0.001). Cardiopulmonary bypass and aortic-cross clamping time were significantly lower in the MECC group (p < 0.001). Overall 30-day mortality was significantly higher in patients treated with CECC (4.4% vs. 2.2%; p = 0.002). Within the different age groups mortality rates were not significantly different except for patients aged 60-69 years (4.5% vs. 1.8%; p = 0.03). Postoperative requirement of renal replacement therapy (4% vs. 2.2%; p = 0.01), respiratory insufficiency (9.9% vs. 6.6%; P = 0.004) and incidence of low cardiac output syndrome (3% vs. 1.2%; p = 0.003) were significantly increased in patients with CECC. Multivariate analysis identified age (p = 0.005; 95% CI 1.01 to 1.08; OR 1.05) among other parameters as an independent risk factor, whereas conventional extracorporeal circulation itself did not present as an independent risk factor for 30-day mortality. CONCLUSIONS: In this matched study sample early outcome was significantly better in patients with MECC compared to CECC, irrespective of age. Prior myocardial infarction estimated GFR < 60 mL and waiving the use of LIMA were independent risk factors for 30-day mortality, which were more present in the CECC group.


Asunto(s)
Puente Cardiopulmonar/métodos , Puente de Arteria Coronaria/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Puente Cardiopulmonar/efectos adversos , Puente Cardiopulmonar/mortalidad , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Periodo Posoperatorio , Insuficiencia Renal/etiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
19.
J Cardiothorac Surg ; 9: 93, 2014 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-24884921

RESUMEN

BACKGROUND: LVAD speed adjustment according to a functioning aortic valve has hypothetic advantages but could lead to submaximal support. The consequences of an open aortic valve policy on exercise capacity and hemodynamics have not yet been investigated systematically. METHODS: Ambulatory patients under LVAD support (INCOR®, Berlin Heart, mean support time 465 ± 257 days, average flow 4.0 ± 0.3 L/min) adjusted to maintain a near normal aortic valve function underwent maximal cardiopulmonary exercise testing (CPET) and right heart catheterization (RHC) at rest and during constant work rate exercise (20 Watt). RESULTS: Although patients (n = 8, mean age 45 ± 13 years) were in NYHA class 2, maximum work-load and peak oxygen uptake on CPET were markedly reduced with 69 ± 13 Watts (35% predicted) and 12 ± 2 mL/min/kg (38% predicted), respectively. All patients showed a typical cardiac limitation pattern and severe ventilatory inefficiency with a slope of ventilation to carbon dioxide output of 42 ± 12. On RHC, patients showed an exercise-induced increase of mean pulmonary artery pressure (from 16 ± 2.4 to 27 ± 2.8 mmHg, p < 0.001), pulmonary artery wedge pressure (from 9 ± 3.3 to 17 ± 5.3 mmHg, p = 0.01), and cardiac output (from 4.7 ± 0.5 to 6.2 ± 1.0 L/min, p = 0.008) with a corresponding slight increase of pulmonary vascular resistance (from 117 ± 35.4 to 125 ± 35.1 dyn*sec*cm-5, p = 0.58) and a decrease of mixed venous oxygen saturation (from 58 ± 6 to 32 ± 9%, p < 0.001). CONCLUSION: An open aortic valve strategy leads to impaired exercise capacity and hemodynamics, which is not reflected by NYHA-class. Unknown compensatory mechanisms can be suspected. Further studies comparing higher vs. lower support are needed for optimization of LVAD adjustment strategies.


Asunto(s)
Válvula Aórtica/fisiopatología , Tolerancia al Ejercicio/fisiología , Insuficiencia Cardíaca/fisiopatología , Corazón Auxiliar , Adulto , Ejercicio Físico/fisiología , Prueba de Esfuerzo , Insuficiencia Cardíaca/terapia , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad
20.
Ann Thorac Surg ; 98(1): 9-14; discussion 14-5, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24881861

RESUMEN

BACKGROUND: An exploratory analysis of the German Off Pump Coronary Artery Bypass Grafting in Elderly Patients (GOPCABE) trial was performed to investigate the effect of off-pump coronary artery bypass grafting (CABG) on kidney function after the operation. METHODS: Data on kidney function were available from 1,612 patients, representing 67% of the study population. Preoperative kidney function was graded according to the glomerular filtration rate. Acute kidney injury (AKI) within the first week after the operation was defined and classified according to the Acute Kidney Injury Network (AKIN) criteria. The incidence and severity of AKI was compared between patients operated on on-pump or off-pump. RESULTS: Impaired kidney function was seen in 642 patients (40%), and 19 patients had preexisting end-stage kidney disease. AKI of any severity occurred in half of all patients undergoing CABG, with AKIN stage 1 accounting for most of the cases. The incidence and severity of AKI in patients undergoing on-pump vs off-pump CABG was AKIN stage 1: 298 (37%) vs 329 (42%); AKIN stage 2: 38 (5%) vs 43 (5%); and AKIN stage 3: 44 (6%) vs 44 (6%), which did not differ significantly (p=0.174). New renal replacement therapy was necessary in 3.2% (on-pump) and in 2.7% (off-pump) of all patients. Stratification according to preoperative kidney function yielded comparable frequencies of AKI for on-pump and off-pump CABG. CONCLUSIONS: AKI was common in elderly patients undergoing CABG, but deterioration of kidney function requiring renal replacement therapy was a rare event. Off-pump CABG was not associated with decreased rates or reduced severity of AKI in elderly patients.


Asunto(s)
Lesión Renal Aguda/etiología , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/epidemiología , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria Off-Pump/efectos adversos , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Tasa de Filtración Glomerular , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA