Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Clin Med ; 10(21)2021 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-34768456

RESUMEN

(1) Background: Endoscopic colorectal stenting with high technical success and safety is essential in discussing the oncological outcomes for the management of malignant colorectal obstruction. Mechanical properties of self-expandable metal stents are usually considered to affect clinical outcomes. (2) Methods: A multicenter, prospective study was conducted in Japan. A self-expandable metal stent with low axial force was inserted endoscopically. The primary endpoint was clinical success, defined as the resolution of symptoms and radiological findings within 24 h. Secondary endpoints were technical success and adverse events. Short-term outcomes of 7 days were evaluated in this study. (3) Results: Two hundred and five consecutive patients were enrolled. Three patients were excluded, and the remaining 202 patients were evaluated. The technical and clinical success rates were 97.5% and 96.0%, respectively. Major stent-related adverse events included stent migration (1.0%), insufficient stent expansion (0.5%), and stent occlusion (0.5%). No colonic perforation was observed. There were two fatal cases (1%) which were not related to stent placement. (4) Conclusions: The placement of self-expandable metal stents with low axial force is safe with no perforation and showed high technical and clinical success rates in short-term outcomes for the management of malignant colorectal obstruction.

2.
Scand J Gastroenterol ; 56(10): 1229-1235, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34375164

RESUMEN

OBJECTIVE: The treatment result of the uncovered metallic stent (uncovered MS) and covered metallic stent (covered MS) for unresectable malignant distal biliary obstruction is controversial. This time, we conducted this study to compare the efficacies and complication rates of uncovered MS and covered MS in unresectable malignant distal biliary obstructions at a prospective randomized multicenter trial. MATERIALS AND METHODS: From April 2014 to September 2018, patients with unresectable malignant distal biliary obstruction were randomly assigned to 2 groups: the uncovered MS group and the covered MS group. RESULTS: 92 treatment results patients were discussed. 48 patients were assigned to the uncovered MS group and 44 cases were assigned to the covered MS group. Both groups showed a drainage effect. No significant difference was found in the drainage effect between the 2 groups. The number of stent occlusion was significantly greater (p = .0467) in uncovered MS (43.8%) comparing with those in covered MS (22.7%). As the cause of stent occlusion, tumor ingrowth was significantly greater (p < .001) in the uncovered MS group (35.4%) than in the covered MS group (2.3%). The median stent patency period was significantly longer (p = .0112) in the covered MS group (455 days) than that of the uncovered MS group (301 days). A significant difference in the median survival period was not found between the 2 groups. CONCLUSIONS: Covered MS showed the possibility of extending the stent patency period by suppressing tumor ingrowth more than uncovered MS does. The UMIN Clinical Trial Registry number is UMIN000015093.


Asunto(s)
Colestasis , Neoplasias , Colestasis/etiología , Colestasis/cirugía , Humanos , Cuidados Paliativos , Estudios Prospectivos , Stents
3.
Surg Endosc ; 33(2): 499-509, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30006840

RESUMEN

BACKGROUND: Self-expandable metallic stenting (SEMS) for malignant colorectal obstruction (MCO) as a bridge to elective surgery (BTS) is a widely used procedure. The aim of this study was to assess short-term outcomes of SEMS for MCO as BTS. METHODS: This study analyzed pooled data from BTS patients who were enrolled in two multicenter prospective single-arm observational clinical studies that used different stent types. Both studies were conducted by the Japan Colonic Stent Safe Procedure Research Group (JCSSPRG). The first study evaluated the WallFlex™ colonic stent for BTS or palliative treatment (PAL) from May 2012 to October 2013 and the second evaluated the Niti-S™ colonic stent from October 2013 to May 2014. Fifty-three facilities in Japan participated in the studies. Before each study started, the procedure had been shared with the participating institutions by posting details of the standard methods of SEMS placement on the JCSSPRG website. Patients were followed until discharged after surgery. RESULTS: A total of 723 consecutive patients were enrolled in the two studies. After excluding nine patients, the remaining 714 patients were evaluated as a per-protocol cohort. SEMS placement was performed in 426 patients (312 WallFlex and 114 Niti-S) as BTS and in 288 as PAL. In the 426 BTS patients, the technical success rate was 98.1% (418/426). The clinical success rate was 93.8% (392/418). SEMS-related preoperative complications occurred in 8.5% of patients (36/426), perforations in 1.9% (8/426), and stent migration in 1.2% (5/426). Primary anastomosis was possible in 91.8% of patients (391/426), 3.8% of whom (15/393) had anastomosis leakage. The overall stoma creation rate was 10.6% (45/426). The postoperative complication rate was 16.9% (72/426) and mortality rate was 0.5% (2/426). CONCLUSIONS: SEMS placement for MCO as BTS is safe and effective with respect to peri-procedural outcomes. Further investigations are needed to confirm long-term oncological outcomes.


Asunto(s)
Neoplasias Colorrectales/cirugía , Obstrucción Intestinal/cirugía , Stents Metálicos Autoexpandibles , Anciano , Neoplasias Colorrectales/complicaciones , Procedimientos Quirúrgicos Electivos/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Obstrucción Intestinal/etiología , Obstrucción Intestinal/mortalidad , Japón , Masculino , Persona de Mediana Edad , Cuidados Paliativos , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Stents Metálicos Autoexpandibles/efectos adversos
4.
Dig Endosc ; 31(1): 51-58, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30113095

RESUMEN

BACKGROUND AND AIM: Colorectal cancer patients often present with large bowel obstruction. Elective placement of a self-expandable metallic stent (SEMS) can relieve obstruction, but can be challenging. Previous studies have compared cases by outcomes only, but the present study investigated successful cases only to identify factors related to prolonged and difficult SEMS placement in patients with malignant colonic obstruction. METHODS: A post-hoc analysis of a multicenter clinical trial conducted between March 2012 and October 2013 at 46 facilities across Japan (UMIN000007953) was carried out; 511 patients who required SEMS placement for acute colorectal obstruction or symptomatic stricture secondary to malignant neoplasm were enrolled. Technical success rates and procedure times were recorded. Clinical and interventional parameters were investigated for their potential effect on procedure time by univariate and multivariate analyses. RESULTS: Technical success rate of SEMS placement was 98%. Median procedure time was 30 (range, 4-170) min. In 27% of patients, procedure time exceeded 45 min, indicating technically difficult placement. Multivariate analyses showed significant associations between technically difficult placement and a ColoRectal Obstruction Scoring System (CROSS) score of 0 before SEMS placement (odds ratio [OR], 1.6; P < 0.05), tumor site in the right colon (OR, 2.5; P < 0.0001), stricture length ≥5 cm (OR, 2.2; P < 0.001), peritoneal carcinomatosis (OR, 1.7; P < 0.05), and multiple SEMS placement (OR, 8.0; P < 0.01). CONCLUSION: Clinicians must anticipate technical challenges in cases with peritoneal carcinomatosis, a CROSS score of 0, or expansive strictures; such cases require experienced clinicians to carry out SEMS placement.


Asunto(s)
Enfermedades del Colon/cirugía , Neoplasias Colorrectales/patología , Obstrucción Intestinal/cirugía , Stents Metálicos Autoexpandibles , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Enfermedades del Colon/etiología , Enfermedades del Colon/patología , Femenino , Humanos , Obstrucción Intestinal/etiología , Obstrucción Intestinal/patología , Japón , Masculino , Persona de Mediana Edad , Tempo Operativo , Resultado del Tratamiento
5.
J Infect Chemother ; 25(2): 141-146, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30100399

RESUMEN

Lactococcus lactis is a rare causative organism in humans. Cases of L. lactis infection have only rarely been reported. However, because it is often difficult to identify by conventional commercially available methods, its incidence may be underestimated. We herein report the case of a 70-year-old man with cholangiocarcinoma who developed L. lactis cholangitis and review previously reported cases of L. lactis infection. Our case was confirmed by matrix-assisted desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). This case shows L. lactis is a potential causative pathogen of cholangitis and that MALDI-TOF MS can be useful for the rapid and accurate identification of L. lactis infection. We searched the literature for published case reports on cholangitis and any other infections caused by L. lactis, and thereby identified 36 cases, including our case. At least 66.7% (n = 24) of the cases had significant underlying conditions; 15 of the cases involved patients with an immunocompromised status. At least 41.7% (n = 15) had a significant food consumption history, such as the consumption of unpasteurized dairy products. The clinical sources of L. lactis were diverse and endocarditis was the most common diagnosis (n = 8), followed by hepatobiliary infection (n = 6), central nervous system infection (n = 5), and peritonitis (n = 4). The prognosis was favorable in most cases.


Asunto(s)
Bacteriemia/diagnóstico , Colangitis/diagnóstico , Infecciones por Bacterias Grampositivas/diagnóstico , Lactococcus lactis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Anciano , Humanos , Masculino , Tipificación Molecular
6.
Intern Med ; 56(12): 1515-1519, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28626176

RESUMEN

A 95-year-old Japanese woman presented to our hospital with intermittent vomiting and several episodes of melena. Abdominal computed tomography revealed intussusception of the gastric tumor into the duodenum. After endoscopic reduction, endoscopic ultrasonography identified a hypoechogenic lesion limited to the submucosal layer. Endoscopic resection was performed as a localized treatment for the prevention of recurrent gastroduodenal intussusception. To our knowledge, there have been no other reports describing a gastric gastrointestinal stromal tumor presenting with gastroduodenal intussusception and treated using an endoscopic submucosal dissection technique.


Asunto(s)
Resección Endoscópica de la Mucosa/métodos , Tumores del Estroma Gastrointestinal/cirugía , Intususcepción/cirugía , Anciano de 80 o más Años , Endosonografía , Femenino , Tumores del Estroma Gastrointestinal/patología , Humanos , Melena , Neoplasias Gástricas/patología , Tomografía Computarizada por Rayos X
7.
Endosc Ultrasound ; 5(6): 390-392, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28000631

RESUMEN

A 71-year-old female was diagnosed with hepatocellular carcinoma (HCC). The tumor measured 65 mm in diameter and was located in the caudate lobe. Transarterial chemoembolization (TACE) was performed repeatedly; however, a follow-up dynamic computed tomography (CT) scan showed that the tumor remained viable. Thus, TACE was performed using drug-eluting beads that had been preloaded with epirubicin. Contrast-enhanced endoscopic ultrasonography (CE-EUS) was conducted for evaluating the treatment effects. First, we detected the internal part of the tumor. Then, a perflubutane suspension was injected intravenously. Next, CE-EUS was performed for the external ventral part of the tumor in the same manner. The perflubutane flowed into the tumor and spread into both its internal and external ventral regions. Thus, we considered that the tumor was still viable and planned to carry out TACE again. CE-EUS could be a useful tool for evaluating the treatment effects of TACE on HCC deep inside the liver.

8.
Endosc Int Open ; 4(10): E1111-E1115, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27747288

RESUMEN

Background and study aims: Accurately puncturing hepatocellular carcinomas (HCC) that arise from the caudate lobe is generally considered to be technically difficult. We conducted a retrospective study to evaluate the feasibility and safety (the therapeutic outcomes and adverse events) of endoscopic ultrasound (EUS)-guided ethanol injection as a novel treatment for HCC in the caudate lobe. Patients and methods: Twelve patients with early-stage HCC of the caudate lobe that were treated with EUS-guided ethanol injection at two tertiary referral centers were reviewed retrospectively. To evaluate the therapeutic effect of the treatment, a local control curve and an overall survival curve were constructed using the Kaplan-Meier method. Results: The mean follow-up duration was 31.0 months. The 1-year local control rate was 80.2 %, and recurrent lesions developed in 2 cases (after 3 and 9 months, respectively). The overall survival rate was 91.7 %, 75.0 %, and 53.3 % at 1, 2, and 3 years, respectively. Concerning procedure-related adverse events (AEs), 2 patients suffered episodes of fever lasting a few days; however, no serious AEs occurred. Conclusions: EUS-guided ethanol injection could be a useful treatment for early-stage HCC in the caudate lobe because of its simplicity and reduced invasiveness.

9.
Surg Endosc ; 30(9): 3976-86, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26684205

RESUMEN

BACKGROUND: Endoscopic stenting with a self-expandable metallic stent (SEMS) is a widely accepted procedure for malignant colonic obstruction. The Colonic Stent Safe Procedure Research Group conducted the present prospective feasibility study. METHODS: Our objectives were to estimate the safety and feasibility of SEMS placement as a bridge to surgery (BTS) for malignant colorectal obstruction. We conducted a prospective, observational, single-arm, multicenter clinical trial from March 2012 to October 2013. Each patient was treated with an uncovered WallFlex enteral colonic stent. Patients were followed up until discharge after surgery. RESULTS: A total of 518 consecutive patients were enrolled in this study. The cohort intended for BTS consisted of 312 patients (61 %), and the stent could be released in 305 patients. Technical and clinical success rates were 98 and 92 %, respectively. Elective surgery was performed in 297 patients, and emergency surgery was performed in eight patients for the treatment of complications. The overall preoperative complication rate was 7.2 %. Major complications, including perforation, occurred in 1.6 %, persistent colonic obstruction occurred in 1.0 %, and stent migration occurred in 1.3 % patients. The median time from SEMS to surgery was 16 days. Silent perforations were observed in 1.3 %. Open and laparoscopic surgery was performed in 121 and 184 patients, respectively. The tumor could be resected in 297 patients. The primary anastomosis rate was 92 %. The rate of anastomotic leakage was 4 %, and the overall stoma creation rate was 10 %. The median duration of hospitalization following surgery was 12 days. Overall postoperative morbidity and mortality rates were 16 and 0.7 %, respectively. CONCLUSIONS: This largest, multicenter, prospective study demonstrates the feasibility of SEMS placement as a BTS for malignant colorectal obstruction. SEMS serves as a safe and effective BTS with acceptable stoma creation and complication rates in patients with acute malignant colonic obstruction.


Asunto(s)
Neoplasias del Colon/complicaciones , Obstrucción Intestinal/etiología , Obstrucción Intestinal/cirugía , Neoplasias del Recto/complicaciones , Stents Metálicos Autoexpandibles , Adulto , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Electivos , Urgencias Médicas , Estudios de Factibilidad , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos
11.
Gastrointest Endosc ; 82(4): 697-707.e1, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25975529

RESUMEN

BACKGROUND: Endoscopic self-expandable metal stent placement has been used as an alternative to surgery for malignant colorectal obstruction; however, factors affecting its clinical outcome are unclear. OBJECTIVE: To clarify the short-term safety and efficacy of endoscopic self-expandable metal stent placement for malignant colorectal obstruction and to identify factors associated with its clinical and technical failure. DESIGN: Prospective clinical cohort study. SETTING: Fourteen academic centers and 32 community hospitals. PATIENTS: A total of 513 consecutive patients with malignant colorectal obstruction. INTERVENTION: Endoscopic self-expandable metal stent placement, sharing of stent placement methods among participating facilities. MAIN OUTCOME MEASUREMENTS: The primary endpoint was clinical success, defined as symptom and radiological finding resolution within 24 hours. Secondary endpoints were technical success and adverse events. The follow-up period was 7 days. RESULTS: The clinical and technical success rates were 95.5% and 97.9%, respectively. Major adverse events included perforation (2.1%), stent migration (1.0%), and stent occlusion (0.8%). The main causes of perforation were the procedure itself (0.8%) and comorbidities (obstructive colitis and impending perforation) not apparent before stent placement (0.6%). Extrinsic tumor origin was independently associated with the clinical failure after stent placement (odds ratio 4.23; 95% confidence interval, 1.21-14.79; P = .02). Stricture marking trended toward a negative association with technical failure (P = .09). LIMITATIONS: Noncomparative study. CONCLUSION: Strict inclusion criteria and stricture marking may improve the technical and clinical success of stent placement.


Asunto(s)
Neoplasias Colorrectales/complicaciones , Obstrucción Intestinal/terapia , Stents Metálicos Autoexpandibles , Adulto , Anciano , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Obstrucción Intestinal/etiología , Japón , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
13.
Dig Endosc ; 27(1): 159-61, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24684669

RESUMEN

In the expanded indications for endoscopic resection, Japanese guidelines for gastric cancer include differentiated cancers confined to the mucosa with an ulcer <30 mm. We describe a patient with lymph node metastasis after curative endoscopic submucosal dissection (ESD) for a tumor of this indication. The patient was a 70-year-old man with chronic hepatitis C. He underwent ESD for early gastric cancer in May 2010. Pathology revealed a moderately differentiated adenocarcinoma, 22 × 17 mm in size, that was confined to the mucosa with an ulcer. The horizontal and vertical margins were negative for the tumor. We diagnosed thiscase as curative resection of expanded indication and followed this patient with endoscopy, abdominal ultrasonography (AUS) or enhanced computed tomography (CT) approximately every 6 months. After 17 months, lymph node metastasis was detected with AUS and CT and diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy in August 2011. Distal gastrectomy with D2 dissection was carried out in December 2011. Although it is low, the possibility of recurrence should be borne in mind after endoscopic treatment of early gastric cancer, despite its inclusion in the expanded indications for endoscopic resection.


Asunto(s)
Adenocarcinoma/cirugía , Gastrectomía/métodos , Mucosa Gástrica/patología , Gastroscopía/métodos , Neoplasias Gástricas/cirugía , Úlcera/cirugía , Adenocarcinoma/diagnóstico , Adenocarcinoma/secundario , Anciano , Biopsia , Biopsia con Aguja Fina , Disección/métodos , Mucosa Gástrica/cirugía , Humanos , Ganglios Linfáticos/patología , Metástasis Linfática , Masculino , Neoplasias Gástricas/complicaciones , Neoplasias Gástricas/patología , Úlcera/etiología , Úlcera/patología
14.
World J Gastroenterol ; 20(16): 4817-21, 2014 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-24782637

RESUMEN

Gastrointestinal stromal tumors (GISTs) usually develop in the stomach and small intestine and only rarely occur at the ampulla of Vater, with only 11 cases reported in the literature. We report a case of a GIST of the ampulla of Vater. A 36-year-old, previously healthy man presented with a loss of consciousness lasting a few minutes. A gastroduodenal endoscopy revealed a submucosal tumor with central ulceration at the ampulla of Vater. The enhanced computed tomography scan revealed a smooth-outlined hypervascular solid mass (24 mm × 30 mm) in the second part of the duodenum. Neither lymphadenopathy nor metastasis was observed. Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography showed normal bile and pancreatic ducts. Biopsies were collected from the ulcerative lesion, and the tumor was diagnosed as a GIST. A submucosal tumor with central ulceration may be a characteristic form of GISTs of the ampulla of Vater, and biopsy studies are useful for the diagnosing such tumors. The patient underwent pancreatoduodenectomy, and the operative specimen revealed a 2.2-cm GIST with 1 mitosis per 50 high-power fields. The gold standard for treatment of GISTs is surgical resection without rupture of a capsule. If technically possible, local resection may be considered. However, when the location of the lesion presents challenges, a pancreatoduodenectomy should be performed for GIST of the ampulla of Vater.


Asunto(s)
Ampolla Hepatopancreática/patología , Neoplasias del Conducto Colédoco/patología , Tumores del Estroma Gastrointestinal/patología , Adulto , Ampolla Hepatopancreática/química , Ampolla Hepatopancreática/diagnóstico por imagen , Ampolla Hepatopancreática/cirugía , Biomarcadores de Tumor/análisis , Proliferación Celular , Colangiopancreatografia Retrógrada Endoscópica , Pancreatocolangiografía por Resonancia Magnética , Neoplasias del Conducto Colédoco/química , Neoplasias del Conducto Colédoco/cirugía , Duodenoscopía , Endosonografía , Tumores del Estroma Gastrointestinal/química , Tumores del Estroma Gastrointestinal/cirugía , Gastroscopía , Humanos , Inmunohistoquímica , Masculino , Índice Mitótico , Pancreaticoduodenectomía , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
15.
Endoscopy ; 46(3): 248-51, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24573734

RESUMEN

We present three cases of pseudoaneurysm caused by self-expandable metal stents that formed arteriobiliary fistulas and caused hemobilia. Diagnoses were made on the basis of dynamic computed tomography or angiography. One patient died because of bleeding and cholangitis, whereas the others were successfully treated by transarterial embolization.


Asunto(s)
Aneurisma Falso/etiología , Fístula Biliar/etiología , Enfermedades del Conducto Colédoco/etiología , Stents/efectos adversos , Fístula Vascular/etiología , Anciano , Anciano de 80 o más Años , Aneurisma Falso/terapia , Fístula Biliar/terapia , Colangiopancreatografia Retrógrada Endoscópica , Colangitis/etiología , Enfermedades del Conducto Colédoco/terapia , Embolización Terapéutica , Endoscopía Gastrointestinal , Resultado Fatal , Femenino , Hemobilia/etiología , Humanos , Masculino , Metales , Fístula Vascular/terapia
16.
Clin J Gastroenterol ; 7(2): 180-4, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26183638

RESUMEN

Pancreatic involvement is an extremely rare manifestation of lymphoblastic lymphoma (LBL), and only a few cases have been reported. We report a case of LBL arising from the pancreas that was diagnosed using endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 57-year-old female who had suffered from abdominal pain for 2 weeks. A physical examination revealed an upper abdominal mass, but did not detect peripheral lymphadenopathy. Imaging studies including computed tomography (CT) and (18)F-fluorodeoxy glucose (FDG)-positron emission tomography-CT revealed an enlarged pancreatic body, which was positive for FDG uptake. EUS-FNA detected medium-sized proliferating atypical lymphocytes, and immunohistochemical staining demonstrated that these cells were positive for CD20, CD10, PAX5, and terminal deoxynucleotidyl transferase. A bone marrow examination was negative for lymphoma infiltration, and a diagnosis of LBL arising from the pancreas was made. The patient was successfully treated with a combination of chemotherapy and pancreatic irradiation.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pancreáticas/patología , Leucemia-Linfoma Linfoblástico de Células Precursoras/patología , Femenino , Humanos , Persona de Mediana Edad , Neoplasias Pancreáticas/terapia , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia
17.
Cancer Chemother Pharmacol ; 73(2): 389-96, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24322377

RESUMEN

PURPOSE: The aim of this study was to evaluate efficacy and safety of gemcitabine plus S-1 (GS) combination chemotherapy in patients with unresectable pancreatic cancer. METHODS: Patients were randomly assigned to receive GS (oral S-1 60 mg/m(2) daily on days 1-15 every 3 weeks and gemcitabine 1,000 mg/m(2) on days 8 and 15) or gemcitabine (1,000 mg/m(2) on days 1, 8, and 15 every 4 weeks). The primary endpoint was progression-free survival (PFS). RESULTS: One hundred and one patients were randomly assigned. PFS was significantly longer in the GS arm with an estimated hazard ratio (HR) of 0.65 (95 % CI 0.43-0.98; P = 0.039; median 5.3 vs 3.8 months). Objective response rate (ORR) was also better in the GS arm (21.6 vs 6 %, P = 0.048). Median survival was 8.6 months for GS and 8.6 months for GEM (HR 0.93; 95 % CI 0.61-1.41; P = 0.714). Grade 3-4 neutropenia (44 vs 19.6 %, P = 0.011) and thrombocytopenia (26 vs 8.7 %, P = 0.051) were more frequent in the GS arm. CONCLUSIONS: GS therapy improved PFS and ORR with acceptable toxicity profile in patients with unresectable pancreatic cancer.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Neoplasias Pancreáticas/tratamiento farmacológico , Anciano , Desoxicitidina/administración & dosificación , Desoxicitidina/análogos & derivados , Supervivencia sin Enfermedad , Esquema de Medicación , Combinación de Medicamentos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Ácido Oxónico/administración & dosificación , Neoplasias Pancreáticas/patología , Estudios Prospectivos , Tegafur/administración & dosificación , Resultado del Tratamiento , Gemcitabina , Neoplasias Pancreáticas
18.
Hepatogastroenterology ; 60(128): 1854-60, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24088309

RESUMEN

BACKGROUND/AIMS: Covered metallic stent was developed to prevent tumor ingrowth. However, procedural accidents due to its insertion often occur and migration after long-term insertion causes problems. The WallFlex partially covered stent (WF) with reduced axial force enables stenting along the bile duct. We examined the usefulness of WF placement in an unresectable malignant distal biliary obstruction. METHODOLOGY: We examined procedural accidents, stent obstruction rate, and patency period caused by WF insertion. RESULTS: Ninety-seven patients were analyzed; procedural accidents caused by WF insertion occurred in 8 patients (7.2%) composed of acute cholecystitis in 3 patients (3.2%), acute pancreatitis in 2 patients (2.1%), acute cholangitis in 1 patient (1%), and other in 1 patient (1%). The stent obstruction rate was 19.6% (19 patients), and obstruction cause includes sludge in 9 patients (9.3%), migration in 4 patients (4.1%), food impaction in 3 patients (3.1%), ingrowth in 1 patient (1%), overgrowth in 0 patients (0%), and unknown in 2 patients (2.1%). The mean stent patency period was 634.918 +/- 66.545 (7-946) days. CONCLUSIONS: WF has less procedural accidents when inserted into unresectable malignant biliary obstruction patients with reduced migration rate after a long period and low obstruction rate.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/instrumentación , Colestasis/terapia , Neoplasias/complicaciones , Stents , Anciano , Anciano de 80 o más Años , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colestasis/diagnóstico por imagen , Colestasis/etiología , Femenino , Humanos , Japón , Masculino , Metales , Persona de Mediana Edad , Cuidados Paliativos , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Factores de Tiempo , Resultado del Tratamiento
19.
Nihon Shokakibyo Gakkai Zasshi ; 110(4): 669-78, 2013 Apr.
Artículo en Japonés | MEDLINE | ID: mdl-23558131

RESUMEN

A 42-year-old woman was admitted to our hospital with weight loss and right upper quadrant abdominal pain. Though an 8cm mass in liver segment 5/8 was detected by abdominal imaging, we could not confirm the diagnosis because findings on physical examination, blood chemistry, and radiologic examination were nonspecific. No cancer or immunocompromising diseases were found. We performed a liver biopsy because we were suspicious of a cold abscess caused by tuberculosis. Purulent material acquired from the biopsy revealed positive TB-PCR results, which confirmed the diagnosis of solitary liver tuberculosis. She received anti-tuberculosis medications leading to hepatic tumor resolution. There are very few reports of solitary liver tuberculosis diagnosed without surgery, thus we report this case of a solitary tubercle diagnosed by TB-PCR.


Asunto(s)
Reacción en Cadena de la Polimerasa , Tuberculosis Hepática/diagnóstico , Tuberculosis Hepática/tratamiento farmacológico , Adulto , Antituberculosos/uso terapéutico , Femenino , Humanos , Mycobacterium tuberculosis/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA