Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Clin Apher ; 36(1): 135-142, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33247855

RESUMEN

BACKGROUND: Peripheral blood stem cell (PBSC) collection is important for successful hematopoietic stem cell transplantation. This study aimed to investigate the laboratory parameters associated with the optimal timing of autologous PBSC collection from lymphoma and multiple myeloma patients. METHODS: We retrospectively evaluated data from 1105 PBSC apheresis procedures performed on 379 adult patients at the National Cancer Center between June 2005 and December 2019. Laboratory parameters, including cutoff values for the number of hematopoietic progenitor cells (HPCs) and circulating CD34+ cells, were analyzed to determine their association with CD34+ cell yield. RESULTS: The pre-apheresis HPC and CD34+ cell count were statistically significant variables associated with harvested CD34+ cell in lymphoma and MM patients. The optimal cutoff values were 18 × 106 /L for pre-HPC count (66.8% sensitivity, 66.4% specificity) and 11/µL for pre-CD34+ cell count (85.8% sensitivity, 87.2% specificity), to achieve CD34+ cell yields ≥ 1.0 × 106 /kg for each apheresis procedure. Moreover, the optimal cutoff values were 23 × 106 /L for pre-HPC count (71.0% sensitivity, 69.0% specificity) and 18/µL for pre-CD34+ cell count (87.5% sensitivity, 86.3% specificity) to achieve CD34+ cell yields ≥ 2.0 × 106 /kg for each apheresis procedure. CONCLUSION: HPC count is a potential surrogate marker for monitoring the starting time for PBSC collection. Applying cutoff values for the number of HPC and CD34+ cells may be clinically useful for optimizing the timing of PBSC collection.


Asunto(s)
Eliminación de Componentes Sanguíneos/métodos , Movilización de Célula Madre Hematopoyética/métodos , Linfoma/terapia , Mieloma Múltiple/terapia , Trasplante de Células Madre de Sangre Periférica/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neutrófilos , Estudios Retrospectivos , Trasplante Autólogo , Adulto Joven
2.
J Clin Apher ; 36(1): 28-33, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32882095

RESUMEN

INTRODUCTION: Autologous peripheral blood stem cell (PBSC) transplantation has become a standard treatment option for many oncology patients. The aim of this study was to evaluate the performance of two cell separators, Spectra Optia (Terumo BCT, Japan) and Amicus (Fresenius-Kabi) for autologous PBSC collection. METHODS: We retrospectively evaluated 56 apheresis by Spectra Optia with Continuous Mononuclear Cell Collection (cMNC) from 20 patients, and 50 apheresis by Amicus from 27 patients between December 2018 and December 2019. CD34+ collection efficiency (CE2) and platelet (PLT) loss were evaluated. RESULTS: There was no significant difference in CD34+ CE2 between Spectra Optia with cMNC (median, 28.8%) and Amicus (median, 33.1%; P = 0.537). PLT loss was significantly lower in Amicus (median, 28.6%) than in Spectra Optia with cMNC (median, 37.8%; P = 0.009). CONCLUSION: CD34+ CE2 was comparable between Spectra Optia and Amicus, and PLT loss was significantly lower in Amicus. To the best of our knowledge, this is the first report comparing autologous PBSC collection of the Spectra Optia and Amicus. These results may provide general guidance with regard to device selection to apheresis clinics that use both separators for optimal outcomes depending on each patient's characteristics.


Asunto(s)
Eliminación de Componentes Sanguíneos/métodos , Movilización de Célula Madre Hematopoyética/métodos , Células Madre de Sangre Periférica/citología , Adulto , Eliminación de Componentes Sanguíneos/instrumentación , Femenino , Movilización de Célula Madre Hematopoyética/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Trasplante Autólogo , Adulto Joven
3.
Transfus Apher Sci ; 59(2): 102679, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31831328

RESUMEN

BACKGROUND: The collection of a sufficient number of stem cells is important for success of allogeneic hematopoietic stem cell transplantation (HSCT). This study aimed to investigate the factors associated with successful allogeneic peripheral stem cell (PBSC) collection in healthy donors. METHODS: We retrospectively reviewed clinical data of allogeneic PBSC collection in 175 donors from 2007 to 2017 at the National Cancer Center, Korea. This study analyzed factors associated with the CD34+ cell yield such as the characteristics of donors, including age, laboratory results before apheresis, and data of procedures on the first day. The CD34+ cell dose of ≥ 4.0 × 106/kg have recently been the accepted minimum recommended dose in allogeneic HSCT settings, and this was the target dose in our study. RESULTS: The factors associated with the CD34+ cell yield were age (p = 0.007), baseline platelet (PLT) (p = 0.014), and pre-collection hematopoietic progenitor cells (HPCs) (p = 0.001) by multivariate analysis. This study represented that age, baseline platelet count, and pre-collection HPC count are important predictive factors as shown in other previous studies. CONCLUSION: Our data suggest that young age, high baseline platelet counts and high HPC counts before collection might be useful for identifying successful mobilizers.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas/métodos , Acondicionamiento Pretrasplante/métodos , Trasplante Homólogo/métodos , Adolescente , Adulto , Anciano , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Donantes de Tejidos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA