Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Inorg Biochem ; 257: 112585, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38718498

RESUMEN

Ruthenium complexes are one of the most promising anticancer drugs and ferroptosis is a novel form of regulated cell death, the study on the effect of Ru complexes on ferroptosis is helpful to find more effective antitumor drugs. Here, the synthesis and characterization of two Ru complexes containing 8-hydroxylquinoline and triphenylphosphine as ligands, [Ru(L1) (PPh3)2Cl2] (Ru-1), [Ru(L2) (PPh3)2Cl2] (Ru-2), were reported. Complexes Ru-1 âˆ¼ Ru-2 showed good anticancer activity in Hep-G2 cells. Researches indicated that complexes Ru-1 âˆ¼ Ru-2 could be enriched and appear as red fluorescence in the mitochondria, arouse dysfunction of mitochondria, induce the accumulation of reactive oxygen species (ROS) and lipid peroxidation (LPO), while the morphology of nuclei and cell apoptosis had no significant change. Further experiments proved that GPX4 and Ferritin were down-regulated, which eventually triggered ferroptosis in Hep-G2 cells. Remarkably, Ru-1 showed high inhibitory activity against xenograft tumor growth in vivo (TGIR = 49%). This study shows that the complex Ru-1 could act as a novel drug candidate by triggering cell ferroptosis.


Asunto(s)
Antineoplásicos , Complejos de Coordinación , Ferroptosis , Mitocondrias , Rutenio , Ferroptosis/efectos de los fármacos , Humanos , Antineoplásicos/farmacología , Antineoplásicos/química , Antineoplásicos/síntesis química , Animales , Rutenio/química , Complejos de Coordinación/farmacología , Complejos de Coordinación/química , Complejos de Coordinación/síntesis química , Mitocondrias/efectos de los fármacos , Mitocondrias/metabolismo , Ratones , Células Hep G2 , Especies Reactivas de Oxígeno/metabolismo , Compuestos Organofosforados/química , Compuestos Organofosforados/farmacología , Ratones Desnudos , Ensayos Antitumor por Modelo de Xenoinjerto , Oxiquinolina/química , Oxiquinolina/farmacología , Peroxidación de Lípido/efectos de los fármacos , Ratones Endogámicos BALB C
2.
Interact Cardiovasc Thorac Surg ; 32(4): 552-559, 2021 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-33751118

RESUMEN

OBJECTIVES: Localizing non-palpable pulmonary nodules is challenging for thoracic surgeons. Here, we investigated the accuracy of three-dimensional (3D) printing technology combined with mixed reality (MR) for localizing ground glass opacity-dominant pulmonary nodules. METHODS: In this single-arm study, we prospectively enrolled patients with small pulmonary nodules (<2 cm) that required accurate localization. A 3D-printing physical navigational template was designed based on the reconstruction of computed tomography images, and a 3D model was generated through the MR glasses. We set the deviation distance as the primary end point for efficacy evaluation. Clinicopathological and surgical data were obtained for further analysis. RESULTS: Sixteen patients with 17 non-palpable pulmonary nodules were enrolled in this study. Sixteen nodules were localized successfully (16/17; 94.1%) using this novel approach with a median deviation of 9 mm. The mean time required for localization was 25 ± 5.2 min. For the nodules in the upper/middle and lower lobes, the median deviation was 6 mm (range, 0-12.0) and 16 mm (range, 15.0-20.0), respectively. The deviation difference between the groups was significant (Z = -2.957, P = 0.003). The pathological evaluation of resection margins was negative. CONCLUSIONS: The 3D printing navigational template combined with MR can be a feasible approach for localizing pulmonary nodules.


Asunto(s)
Realidad Aumentada , Nódulos Pulmonares Múltiples , Impresión Tridimensional , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/cirugía , Cirugía Torácica Asistida por Video , Tomografía Computarizada por Rayos X
3.
Thorac Cancer ; 11(9): 2690-2697, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32686309

RESUMEN

BACKGROUND: Localization of small pulmonary nodules is an inevitable challenge for the thoracic surgeon. This study aimed to investigate the accuracy of three-dimensional (3D) printing technology for localizing small pulmonary nodules, especially ground-glass nodules (GGNs). METHODS: This study enrolled patients with peripheral small pulmonary nodules (≤ 2 cm) who required preoperative localization. In the comparison period, patients underwent both computed tomography-guided (CT-G) and 3D-printing template guided (3D-G) localization to compare the accuracies of the two methods. In the testing period, the 3D-printing technique was implemented alone. The 3D-printing physical navigational template was designed based on data from perioperative CT images. Clinical data, imaging data, surgical data, and evaluation index were collected for further analysis. The learning curve of the 3D-printing localization technique was assessed using cumulative sum (CUSUM) analysis and multiple linear regression analysis. RESULTS: In the comparison period (n = 14), the success rates of CT-G and 3D-G were 100% and 92.9% (P = 0.31), respectively; in the testing period (n = 23), the success rate of 3D-G was 95.6%. The localization times of CT-G, 3D-G (comparison), and 3D-G (testing) were 23.6 ± 5.3, 19.3 ± 6.8, and 9.8 ± 4.6 minutes, respectively. The CUSUM learning curve was modeled using the equation: Y = 0.48X2 - 0.013X - 0.454 (R2 = 0.89). The learning curve was composed of two phases, phase 1 (the initial 20 patients) and phase 2 (the remaining 17 patients). CONCLUSIONS: 3D printing localization has adequate accuracy and is a feasible and accessible strategy for use in localizing small pulmonary nodules, especially in right upper lobe. The use of this technique could facilitate lung nodule localization prior to surgery.


Asunto(s)
Nódulos Pulmonares Múltiples/diagnóstico por imagen , Impresión Tridimensional/normas , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/cirugía , Resultado del Tratamiento
4.
Coron Artery Dis ; 26(4): 308-16, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25714067

RESUMEN

PURPOSE: To assess the impact of chest circumference (CC)-adjusted tube current and iterative reconstructions (iDose) on individualized radiation dose reduction and image quality (IQ) in ECG-triggered computed tomography coronary angiography (CTCA). MATERIALS AND METHODS: A total of 102 patients underwent retrospectively ECG-triggered CTCA utilizing CC-adapted tube current [mAs=1000×(0.051×CC-23.765)/900] and filtered back projection (FBP) reconstruction (group A). On the basis of the CC-adjusted tube current technique, 54 patients (group B) underwent retrospective ECG-triggered CTCA with a 20% mAs reduction compared with group A and 90 patients (group C) underwent prospective ECG-triggered CTCA with an 80% mAs reduction compared with group A; both groups B and C were reconstructed with FBP and iDose. Subjective IQ was assessed, and image noise, signal-to-noise, and contrast-to-noise ratios (SNR and CNR) were quantified. RESULTS: Patients in group A had the highest radiation dose, followed by group B and group C. iDose provided decreased image noise and increased SNR and CNR, as did subjective IQ. The image noise was higher and SNR and CNR in group B were obviously lower than those in group A with FBP, but in group B, iDose4 increased the mean objective IQ. There was no difference between group B with iDose and group A with FBP, as was the case with subjective IQ. CONCLUSION: The combination of a CC-adapted technique, prospective triggering, and partial iterative reconstruction techniques reduces the radiation dose significantly, without significant degradation of IQ.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos
5.
Hellenic J Cardiol ; 55(5): 393-401, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25243438

RESUMEN

INTRODUCTION: We aimed to determine a potentially optimal body size index for adjusting the tube current in retrospective ECG-triggered helical 256-slice CT coronary angiography (CTCA) for individualized radiation dose control. METHODS: Consecutive patients (n=102) with suspected coronary artery disease underwent retrospective ECG-triggered CTCA with a 256-slice CT scanner. Body mass index (BMI), nipple level (NL) bust and six anthropometric body size indexes, including thoracic anteroposterior diameter at NL, chest circumference (CC) at NL, left main (LM) and right coronary artery (RCA) origin level, chest area (CAr) and chest attenuation (CAt) at RCA origin level were measured, and their correlation with image noise in the aorta was evaluated using linear regression. Pearson correlation analysis was performed respectively to determine the body size index that correlated best with the other body size indexes. An equation was derived to use the best correlated body size index for adjusting tube current. RESULTS: Linear regression demonstrated that CCRCA had the best correlation with image noise. Pearson correlation analysis showed that CCNL, CCLM and CArRCA had the closest linear relationship with CCRCA. The equations connecting CCRCA and tube current for males and females were XmA = 662 × (0.055 × CCRCA - 28.594) / 302 and XmA = 662 × (0.049 × CCRCA - 21.584) / 302, respectively, for a fixed image noise value of 30 HU. CONCLUSIONS: Tube current selection is different for males and females, particularly in patients with a small chest circumference. CCRCA is an ideal body index for appropriately adjusting tube current in CTCA for individualized radiation dose control.


Asunto(s)
Tamaño Corporal , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Electrocardiografía/métodos , Tomografía Computarizada Multidetector/instrumentación , Traumatismos por Radiación/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos , Adulto Joven
6.
Eur J Radiol ; 81(11): 3146-53, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22677617

RESUMEN

PURPOSE: To reduce radiation dose for retrospective ECG-triggered helical 256-slice CTCA by determining an optimal body size index to prospectively adjust tube current. METHODS: 102 consecutive patients with suspected CAD underwent retrospective ECG-triggered CTCA using 256-slice CT scanner. Six body size indexes including BMI, nipple level (NL) bust, thoracic anteroposterior diameter at NL, chest circumference (CC) at NL, left main and right coronary artery (RCA) origin level were measured and their correlation with noise was evaluated using linear regression. An equation was developed to use this index to adjust tube current. Additional 102 consecutive patients were scanned with the index-based mAs adjustment. A t-test for independent samples was used to compare radiation dose levels with and without the index-based mAs selection method. RESULTS: Linear regression indicated that CC RCA had the best correlation with noise (R2=0.603). Effective radiation dose was reduced from 16.6±0.9 to 9.8±2.7 mSv (p<0.01), i.e. 40.9% lower dose with the CC RCA-adapted tube current method. The image quality scores indicated no significant difference with and without the size-based mAs selection method. CONCLUSION: An accessible measure of body size, such as CC RCA, can be used to adapt tube current for individualized radiation dose control.


Asunto(s)
Tamaño Corporal , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada Espiral/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Técnicas de Imagen Sincronizada Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
7.
Eur J Cardiothorac Surg ; 41(6): e146-53, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22593259

RESUMEN

OBJECTIVES: To explore the feasibility of evaluating the aortopulmonary collateral flow (APCF) and pulmonary vascular growth of patients who underwent bidirectional Glenn shunting (BGS) using phase-contrast magnetic resonance imaging (PC-MRI) and contrast-enhanced magnetic resonance imaging (CE-MRI). METHODS: Blood flow measurements of the great vessels of the body were recorded in 22 post-BGS patients using 3.0 T PC-MRI. Right and left pulmonary blood flow (Q(P)), stroke volume (SV) of the ascending aorta (Q(S)), blood flow of descending aorta (Q(d)) and venous return of the superior and inferior venae cavae (Q(V)) per minute were calculated using the Report Card software. APCF was equal to the difference between Q(S) and Q(V). The parameters for pulmonary vascular growth were assessed using CE-MRI. The relationship between pulmonary vascular growth and APCF was evaluated using correlation analysis. A comparative analysis was conducted between the MRI results and the results of five cases who underwent cardiac catheterization and 10 cases who underwent angiography. RESULTS: Estimated APCF ranged from 0.23 to 1.63 l/(min/m(2)), accounting for 5-44% of Q(S). Morphologic abnormalities such as pulmonary stenosis, dilatation and thrombosis were clearly visualized through CE-MRI. Significant differences in individual pulmonary artery growth were observed. A significant negative correlation was found between APCF and the pulmonary artery index (PAI; r = -0.461, P = 0.031) when the McGoon rate was 2.04 ± 0.59 and the PAI was 253.27 ± 85.86 mm(2)/m(2). Good consistency or relativity was found between cardiac catheterization, angiography and MRI. CONCLUSIONS: Assessing the APCF and parameters for pulmonary vascular growth in patients who underwent BGS is feasible using 3.0 T PC-MRI integrated with CE-MRI, which may play an important role in clinical and therapeutic decision-making and prognostic evaluation.


Asunto(s)
Aorta/fisiopatología , Circulación Colateral/fisiología , Procedimiento de Fontan , Cardiopatías Congénitas/cirugía , Arteria Pulmonar/fisiopatología , Adolescente , Adulto , Angiocardiografía , Cateterismo Cardíaco , Niño , Preescolar , Medios de Contraste , Estudios de Factibilidad , Femenino , Cardiopatías Congénitas/fisiopatología , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Pronóstico , Arteria Pulmonar/crecimiento & desarrollo , Adulto Joven
8.
Pediatr Radiol ; 41(7): 858-66, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21534003

RESUMEN

BACKGROUND: There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). OBJECTIVE: To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. MATERIALS AND METHODS: From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for ≤ 3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). RESULTS: No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 ± 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 ± 2.2/min (range, 0-8). Mean scan length was 115.3 ± 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 ± 0.4 mGy (range, 1.5-2.8), 24.7 ± 5.9 mGy·cm (range, 14.7-35.8) and 1.6 ± 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. CONCLUSION: Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Angiografía Coronaria/métodos , Cardiopatías Congénitas/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Femenino , Cardiopatías Congénitas/fisiopatología , Frecuencia Cardíaca , Humanos , Lactante , Recién Nacido , Yohexol/análogos & derivados , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad
9.
Zhonghua Xin Xue Guan Bing Za Zhi ; 36(2): 132-6, 2008 Feb.
Artículo en Chino | MEDLINE | ID: mdl-19099950

RESUMEN

OBJECTIVE: To investigate the clinical therapeutic effects of endovascular repair for patients with DeBakey III aortic dissection. METHODS: From December 2002 to June 2007, endovascular TALENT stent-graft exclusion was performed in 75 (65 males, mean age 54.4 +/- 12.6 years) patients with DeBakey III aortic dissection (1 young woman due to Ehlers-Danlos syndrome, 2 young men due to primary aldosteronism and trauma respectively). All patients were diagnosed by contrast enhanced computed tomography (CT) or MRI. Stent-grafts were deployed via femoral artery to exclude the tear of dissection. Aortic angiography was performed immediately after procedure. RESULTS: Eighty-one stent-grafts were installed in 75 patients successfully without operation related dissection. Endoleakage immediately after stent-graft deploying was evidenced in 25 patients and disappeared after stent placements (n = 6) or balloon dilation (n = 19). Two patients died from aortic rupture within 2 days after procedure. Iliac artery was torn in a female patient with Ehlers-Danlos syndrome, this patient developed hemorrhagic shock after stent-graft placement and recovered after anti-shock treatments and iliac artery replacement with synthetic artery. During the follow-up of 1 - 24 months, 2 patients (including the woman with Ehlers-Danlos syndrome) suddenly died half a year after procedure. The remaining patients were alive and well. Repeat CT during follow up showed that reduced lumen size and thrombosis in the false lumen. There was no aortic rupture, endoleak and stent migration during the follow-up period except descending aortic dissection distal of the stent-graft in 1 patient 1 year after procedure and the patient were successfully treated surgically without complication. CONCLUSIONS: Endovascular repair is a safe and effective treatment for patients with DeBakey III aortic dissection, suitable for old patients with high risk of surgery. Ehlers-Danlos syndrome should be considered in young DeBakey III aortic dissection patients without hypertension. Further studies are warranted on endovascular repair therapy for artery complication of Ehlers-Danlos syndrome.


Asunto(s)
Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Stents
10.
Nan Fang Yi Ke Da Xue Xue Bao ; 27(12): 1863-5, 2007 Dec.
Artículo en Chino | MEDLINE | ID: mdl-18159004

RESUMEN

OBJECTIVE: To assess the accuracy of 64-slice spiral CT in diagnosis of restenosis of coronary artery bypass grafts (CABG) and native coronary arteries in patients after bypass surgery. METHODS: Fifty-eight patients receiving bypass surgery with totally 140 CABG (43 arterial and 97 venous grafts) were examined using 64-slice spiral CT. CABG and all native coronary arteries with a diameter of >1.5 mm were evaluated for the presence of significant stenoses (>50% diameter reduction) in comparison with the results by coronary angiography as the golden standard. RESULTS: Of the 140 CABG examined, 38 were occluded and 104 remained patent, all of which were accurately identified by 64-slice spiral CT. The sensitivity of CT for restenosis detection in the patent graft was 100% (18/18) with a specificity of 95.2% (80/84). In the segmental evaluation of the native coronary arteries, the sensitivity of the CT in identifying significant stenosis in the evaluable segments (90%) was 84% (87/103) with a specificity of 74% (384/518). The accuracy of CT in detecting the presence of at least 1 stenosis in the CABG, distal runoff vessels or nongrafted arteries was 91% (53/58). CONCLUSION: CT allows noninvasive angiographic evaluation of both the native coronary arteries and bypass grafts after bypass surgery.


Asunto(s)
Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada Espiral , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA