Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Am Coll Radiol ; 14(11S): S449-S455, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29101983

RESUMEN

Aortic stenosis is a common valvular condition with increasing prevalence in aging populations. When severe and symptomatic, the downstream prognosis is poor without surgical or transcatheter aortic valve replacement. Transcatheter aortic valve replacement is now considered a viable alternative to surgical aortic valve replacement in patients considered high and intermediate risk for surgery. Pre-intervention imaging with echocardiography and CT are essential for procedure planning and device selection to help optimize clinical outcomes with MR angiography playing largely a complementary role. Modern 3-D cross-sectional imaging has consistently shown to help reduce procedural complications from vascular access injury to paravalvular regurgitation and coronary obstruction. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diagnóstico por Imagen/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Medicina Basada en la Evidencia , Humanos , Pronóstico , Sociedades Médicas , Estados Unidos
2.
AJR Am J Roentgenol ; 209(6): 1396-1403, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28981350

RESUMEN

OBJECTIVE: The purpose of this study was to assess the noninferiority of dual-source high-pitch CT angiography (CTA) performed with high-concentration (iopamidol 370) low-volume (60 mL) iodinated contrast material at low voltage (100 kVp) in comparison with dual-source high-pitch CTA with standard-of-care low-concentration (iopamidol 300) standard-volume (75 mL) iodinated contrast material at high voltage (120 kVp) to determine whether use of the high-concentration low-volume method would afford a reduction in radiation dose and contrast volume without negatively affecting vascular opacification. SUBJECTS AND METHODS: This study had three arms. A phantom was used to assess vascular contrast enhancement at different iodine and saline solution dilutions with iopamidol 300 or 370 to compare lower-iodination (iopamidol 300) high-voltage (120 kVp) high-pitch (120 kVp, 250 mAs) imaging with higher-iodination (iopamidol 370) low-voltage (100 kVp) high-pitch (100 kVp, 100-240 mAs) acquisition. Metal-oxide-semiconductor field-effect transistors were placed in an anthropomorphic phantom to extract organ-based radiation profiles, and ANOVA was performed. The study prospectively enrolled 150 patients: 50 patients received 75 mL iopamidol 300, and image acquisition was performed at 120 kVp and 250 mAs; 50 patients received 75 mL iopamidol 370, and acquisition was performed at 100 kVp and 240 mAs; and 50 patients received 60 mL iopamidol, and acquisition was performed at 370 at 100 kVp and 240 mAs. Vascular signal-to-noise ratio was evaluated at 18 anatomic locations. Longitudinal signal-to-noise ratio was used to assess homogeneity of contrast enhancement. Size-specific dose estimates were calculated. Statistical analyses were performed by ANOVA. RESULTS: Noninferiority of high-concentration (iopamidol 370) low-voltage (100 kVp) high-pitch acquisitions compared with low-concentration (iopamidol 300) high-voltage (120 kVp) high-pitch acquisition was achieved at 170 mAs in vitro. Radiation assessment showed significant decreases in radiation dose for the 100-kVp 240-mAs protocol (p < 0.0001). Noninferior vascular contrast (p > 0.280) and luminal homogeneity (p > 0.191) were found for all high-pitch protocols. Significantly decreased radiation dose was observed for the two groups that received 60 and 75 mL of iopamidol 370 at 100 kVp and 240 mAs (p < 0.0001). CONCLUSION: Dual-source high-pitch CTA with high-concentration (iopamidol 370) low-volume (60 mL) iodinated contrast medium and low-voltage acquisition (100 kVp) is noninferior to dual-source high-pitch CTA with low-concentration (iopamidol 300) standard-volume (75 mL) iodinated contrast material at high voltage (120 kVp) and affords simultaneous reduction in radiation dose and contrast volume without negatively affecting vascular contrast enhancement.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Protección Radiológica/métodos , Imagen de Cuerpo Entero , Anciano , Anciano de 80 o más Años , Medios de Contraste/administración & dosificación , Femenino , Humanos , Yopamidol/administración & dosificación , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Dosis de Radiación
3.
Undersea Hyperb Med ; 44(1): 73-77, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28768088

RESUMEN

Arterial gas embolism (AGE) can be clinically devastating, and is most often associated with exposure to changes in ambient pressure, medical procedure or congenital malformation. Here we report a case of AGE in a 78-year-old male without these traditional risk factors. Rather, the patient's history included chronic obstructive pulmonary disease, necrotizing pneumonia, bullous disease and coughing. He was safely treated with hyperbaric oxygen (HBO2) therapy for AGE, with initial clinical improvement, but ultimately died from his underlying condition. Pathophysiology is discussed. This case illustrates the possibility that AGE can occur due to rupture of lung tissue in the absence of traditional risk factors. HBO2 therapy should be considered in the management of such patients.


Asunto(s)
Vesícula/complicaciones , Tos/complicaciones , Embolia Aérea/etiología , Neumonía Necrotizante/complicaciones , Anciano , Enfermedad Crónica , Embolia Aérea/diagnóstico por imagen , Embolia Aérea/terapia , Resultado Fatal , Humanos , Oxigenoterapia Hiperbárica , Masculino , Neumonía Necrotizante/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/complicaciones
4.
Radiology ; 283(2): 526-537, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27935766

RESUMEN

Purpose To develop, in a phantom environment, a method to obtain multidetector computed tomographic (CT) data sets at multiple radiation exposure levels within the same patient and to validate its use for potential dose reduction by using different image reconstruction algorithms for the detection of liver metastases. Materials and Methods The American College of Radiology CT accreditation phantom was scanned by using a dual-source multidetector CT platform. By adjusting the radiation output of each tube, data sets at six radiation exposure levels (100%, 75%, 50%, 37.5%, 25%, and 12.5%) were reconstructed from two consecutive dual-source single-energy (DSSE) acquisitions, as well as a conventional single-source acquisition. A prospective, HIPAA-compliant, institutional review board-approved study was performed by using the same DSSE strategy in 19 patients who underwent multidetector CT of the liver for metastatic colorectal cancer. All images were reconstructed by using conventional weighted filtered back projection (FBP) and sinogram-affirmed iterative reconstruction with strength level of 3 (SAFIRE-3). Objective image quality metrics were compared in the phantom experiment by using multiple linear regression analysis. Generalized linear mixed-effects models were used to analyze image quality metrics and diagnostic performance for lesion detection by readers. Results The phantom experiment showed comparable image quality between DSSE and conventional single-source acquisition. In the patient study, the mean size-specific dose estimates for the six radiation exposure levels were 13.0, 9.8, 5.8, 4.4, 3.2, and 1.4 mGy. For each radiation exposure level, readers' perception of image quality and lesion conspicuity was consistently ranked superior with SAFIRE-3 when compared with FBP (P ≤ .05 for all comparisons). Reduction of up to 62.5% in radiation exposure by using SAFIRE-3 yielded similar reader rankings of image quality and lesion conspicuity when compared with routine-dose FBP. Conclusion A method was developed and validated to synthesize multidetector CT data sets at multiple radiation exposure levels within the same patient. This technique may provide a foundation for future clinical trials aimed at estimating potential radiation dose reduction by using iterative reconstructions. © RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Tomografía Computarizada Multidetector/instrumentación , Fantasmas de Imagen , Exposición a la Radiación/análisis , Radiometría/instrumentación , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Atención Dirigida al Paciente/métodos , Dosis de Radiación , Exposición a la Radiación/prevención & control , Protección Radiológica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Radiometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Cardiovasc Interv Ther ; 32(1): 48-52, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26482076

RESUMEN

A 76-year-old woman presented with progressive heart failure and transfusion-dependent hemolytic anemia due to severe paravalvular aortic regurgitation 4 years after bioprosthetic aortic valve replacement. She was deemed not to be a candidate for redo cardiac surgery due to a porcelain aorta and multiple comorbid medical conditions. We describe the role of pre-procedure contrast-enhanced, ECG-gated computed tomographic angiography to characterize the anatomy of the paravalvular leak connection for appropriate occluder device selection leading to successful percutaneous closure and resolution of the paravalvular regurgitation and hemolytic anemia.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Angiografía por Tomografía Computarizada/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Dispositivo Oclusor Septal , Anciano , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico , Ecocardiografía Transesofágica , Femenino , Hemólisis , Humanos
6.
Ann Thorac Surg ; 103(3): 734-741, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27677566

RESUMEN

BACKGROUND: Current guidelines for imaging surveillance after proximal aortic repair are not evidence based. This study sought to characterize the incidence and causes of reintervention after proximal aortic operations to provide data to guide the frequency and duration of postoperative surveillance. METHODS: Data on all patients undergoing proximal aortic operations (ascending, with or without root, with or without aortic valve replacement, or with or without arch) during a 9-year period (n = 869) at a single institution were prospectively collected. Patients who required reintervention on the proximal or distal aorta were identified and causes for reintervention determined. Planned two-stage repairs and index procedures done at other hospitals were excluded. The primary end point was the time to the first reintervention, and competing-risk Cox regression was used to model reintervention risk. RESULTS: Reinterventions occurred in 4.3% of patients (n = 37), with 48.6% (n = 18) involving the proximal aorta and 51.4% (n = 19) the distal. Median time to reintervention was 2.8 years (interquartile range, 1.5 to 3.6 years). For index aneurysm cases, reintervention for aneurysm of the descending/thoracoabdominal aorta and root were most common. Of the 6 root aneurysms/pseudoaneurysms, 5 (83%) were due to degeneration of a stentless porcine aortic root. For index type A dissections, reintervention for aneurysm of the descending/thoracoabdominal aorta and arch were most common. The mean duration of follow up was 4.2 ± 2.5 years. The 9-year actuarial freedom from reintervention was 92.9%. Cox regression showed index type A dissection was a significant predictor of time to aortic reintervention (hazard ratio, 2.01; 95% confidence interval, 1.04 to 3.9; p = 0.038). CONCLUSIONS: Reinterventions after proximal aortic operations are uncommon; most occur within 3 years of the index operation and involve the proximal and distal aorta nearly equally. Patients with type A dissection or stentless porcine roots require aggressive surveillance, whereas a more liberal approach is suitable for patients without such risk factors. This strategy may reduce the lifetime radiation burden and health care costs.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
AJR Am J Roentgenol ; 206(2): 436-41, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26797375

RESUMEN

OBJECTIVE: The objective of our study was to assess whether the degree and distribution of iliac artery calcifications as determined by a CT-based calcium scoring system correlates with outcomes after renal transplant. MATERIALS AND METHODS: A retrospective review of renal transplant recipients who underwent CT of the pelvis within 2 years before surgery yielded 131 patients: 75 men and 56 women with a mean age of 52 years. Three radiologists assigned a separate semiquantitative score for calcification length, circumferential involvement, and morphology for the common iliac arteries and for the external iliac arteries. The operative and clinical notes were reviewed to determine which iliac arterial segment was used for anastomosis, the complexity of the operation, and whether delayed graft function (DGF) occurred. Renal allograft survival and patient survival were calculated using the Kaplan-Meier technique. RESULTS: Excellent interobserver agreement was noted for each calcification score category. The common iliac arteries showed significantly higher average calcification scores than the external iliac arteries for all categories. Advanced age and diabetes mellitus were independently predictive of higher scores in each category, whereas hypertension, cigarette smoking, hyperlipidemia, and sex were not. Based on multivariate analysis, only the calcification morphology score of the arterial segment used for anastomosis was independently predictive of a higher rate of surgical complexity and of DGF. None of the scores was predictive of graft or patient survival. However, patients with CT evidence of iliac arterial calcification had a lower 1-year survival after transplant than those who did not (92% vs 98%, respectively; p = 0.05). CONCLUSION: Only the calcification morphology score of the arterial segment used for anastomosis was significantly predictive of surgical complexity and of DGF. Routine pretransplant CT for calcification scoring in patients of advanced age or those with diabetes mellitus may enable selection of the optimal artery for anastomosis to optimize outcomes.


Asunto(s)
Supervivencia de Injerto , Arteria Ilíaca/diagnóstico por imagen , Fallo Renal Crónico/terapia , Trasplante de Riñón , Calcificación Vascular/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Fallo Renal Crónico/complicaciones , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Calcificación Vascular/complicaciones
8.
AJR Am J Roentgenol ; 205(4): 834-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26397333

RESUMEN

OBJECTIVE: The purpose of this study was to investigate, both in a phantom experiment and a within-patient clinical study the relationships among radiation dose, image noise, pitch, and body size in MDCT angiography of the thoracoabdominal aorta, with the use of high-pitch dual-source and standard-pitch single-source acquisitions. MATERIALS AND METHODS: A proprietary tapered phantom consisting of four ultrahigh-molecular-weight polyethylene cylinders was used to mimic the body size ranges (small, medium, large, and extra large) of patients in the United States. The phantom was imaged using both standard-pitch (0.8) and various high-pitch (range, 2.0-3.2 [in increments of 0.4]) settings. Standard-pitch and high-pitch acquisitions were also performed in 45 patients (27 men, 18 women; mean age, 67.6 years). RESULTS: At standard pitch, the volume CT dose index (CTDIvol) increased with phantom size, in a logistic sigmoid relationship. At high-pitch settings, the CTDIvol increased gradually in relation to phantom size, up to a threshold (denoted by tCTDI[pitch] ≈ 48.3-7.5 pitch), which linearly decreased (R(2) = 0.99) with pitch (maximum CTDIvol output at pitch [maxCTDI(pitch)] ≈ 18.9-3.9 pitch). A linear decrease in the size-specific dose estimate (SSDE) was observed beyond phantom size thresholds (tSSDE[pitch] ≈ 47.6-8.6 pitch) linearly decreasing (R(2) = 0.98) with pitch (maximum SSDE output at pitch [maxSSDE(pitch)] ≈ 15.5-1.3 pitch). Image noise was statistically significantly lower at standard pitch than at high-pitch settings (p = 0.01). In patients, statistically significant differences were noted between standard and high-pitch settings in the mean CTDIvol(10.8 ± 2.6 and 8.3 ± 0.7 mGy, respectively), SSDE (11.3 ± 2.1 and 8.8 ± 1.5 mGy, respectively), and noise (9.7 ± 2.2 and 14 ± 4.2, respectively) (p < .0001, for all comparisons). CONCLUSION: Lower radiation dose levels achieved with the use of a high-pitch technique reflect limitations in tube output occurring for medium to large body sizes, with an associated exponential increase in noise. The standard- and high-pitch techniques yield similar radiation dose levels for small body sizes.


Asunto(s)
Aorta/efectos de la radiación , Aortografía/métodos , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Anciano , Tamaño Corporal , Femenino , Humanos , Masculino , Fantasmas de Imagen , Estudios Retrospectivos
9.
Am J Cardiol ; 115(11): 1568-73, 2015 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-25846765

RESUMEN

This study sought to compare the accuracy of 2-dimensional transesophageal echocardiography (TEE) and computed tomography angiography (CTA) for noninvasive aortic annular sizing as required for transcatheter aortic valve implantation (TAVI). Direct intraoperative (OR) sizing is the gold standard for aortic annular measurement in surgical aortic valve replacement. Unlike surgical aortic valve replacement, TAVI requires noninvasive assessment of aortic annular dimensions for determining the size of prosthesis to be implanted and controversy exists regarding the best imaging technique for TAVI sizing. Preoperative CTA and OR TEE images of the aortic annulus in 227 patients who underwent proximal aortic surgery with OR annular sizing at the Duke University Medical Center were reviewed. Both imaging techniques were compared with direct OR measurements of aortic annulus diameter using metric sizers as the gold standard. CTA overestimated aortic annulus diameter in 72.2% of cases, with 46.3% >1 TAVI valve-size (>3 mm) overestimations, whereas TEE underestimated aortic annulus diameter in 51.1% of cases, with 16.7% >1 valve-size underestimations. Combining both techniques improved the estimation of aortic annular size. In conclusion, there are limitations to current imaging techniques for noninvasive determination of aortic annular dimensions compared with direct OR sizing. Undersizing by TEE and oversizing by CTA are common and may be related to differences in methods for sizing an elliptical structure. Combining measurements from both techniques would decrease the false exclusion rate for TAVI eligibility because of size mismatch.


Asunto(s)
Angiografía/métodos , Válvula Aórtica/anatomía & histología , Válvula Aórtica/cirugía , Ecocardiografía Transesofágica , Tomografía Computarizada por Rayos X , Válvula Aórtica/diagnóstico por imagen , Precisión de la Medición Dimensional , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Tamaño de los Órganos , Estudios Prospectivos
10.
Radiology ; 274(1): 276-86, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25325324

RESUMEN

PURPOSE: To determine the effectiveness of radiologists' search, recognition, and acceptance of lung nodules on computed tomographic (CT) images by using eye tracking. MATERIALS AND METHODS: This study was performed with a protocol approved by the institutional review board. All study subjects provided informed consent, and all private health information was protected in accordance with HIPAA. A remote eye tracker was used to record time-varying gaze paths while 13 radiologists interpreted 40 lung CT images with an average of 3.9 synthetic nodules (5-mm diameter) embedded randomly in the lung parenchyma. The radiologists' gaze volumes ( GV gaze volume s) were defined as the portion of the lung parenchyma within 50 pixels (approximately 3 cm) of all gaze points. The fraction of the total lung volume encompassed within the GV gaze volume s, the fraction of lung nodules encompassed within each GV gaze volume (search effectiveness), the fraction of lung nodules within the GV gaze volume detected by the reader (recognition-acceptance effectiveness), and overall sensitivity of lung nodule detection were measured. RESULTS: Detected nodules were within 50 pixels of the nearest gaze point for 990 of 992 correct detections. On average, radiologists searched 26.7% of the lung parenchyma in 3 minutes and 16 seconds and encompassed between 86 and 143 of 157 nodules within their GV gaze volume s. Once encompassed within their GV gaze volume , the average sensitivity of nodule recognition and acceptance ranged from 47 of 100 nodules to 103 of 124 nodules (sensitivity, 0.47-0.82). Overall sensitivity ranged from 47 to 114 of 157 nodules (sensitivity, 0.30-0.73) and showed moderate correlation (r = 0.62, P = .02) with the fraction of lung volume searched. CONCLUSION: Relationships between reader search, recognition and acceptance, and overall lung nodule detection rate can be studied with eye tracking. Radiologists appear to actively search less than half of the lung parenchyma, with substantial interreader variation in volume searched, fraction of nodules included within the search volume, sensitivity for nodules within the search volume, and overall detection rate.


Asunto(s)
Movimientos Oculares , Neoplasias Pulmonares/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Competencia Clínica , Toma de Decisiones , Femenino , Humanos , Masculino
11.
Case Rep Neurol Med ; 2014: 406106, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25197589

RESUMEN

Background. Nontraumatic cerebral air embolism cases are rare. We report a case of an air embolism resulting in cerebral infarction related to angioinvasive cavitary aspergillosis. To our knowledge, there have been no previous reports associating these two conditions together. Case Presentation. A 32-year-old female was admitted for treatment of acute lymphoblastic leukemia (ALL). Her hospital course was complicated by pulmonary aspergillosis. On hospital day 55, she acutely developed severe global aphasia with right hemiplegia. A CT and CT-angiogram of her head and neck were obtained demonstrating intravascular air emboli within the left middle cerebral artery (MCA) branches. She was emergently taken for hyperbaric oxygen therapy (HBOT). Evaluation for origin of the air embolus revealed an air focus along the left lower pulmonary vein. Over the course of 48 hours, her symptoms significantly improved. Conclusion. This unique case details an immunocompromised patient with pulmonary aspergillosis cavitary lesions that invaded into a pulmonary vein and caused a cerebral air embolism. With cerebral air embolisms, the acute treatment option differs from the typical ischemic stroke pathway and the provider should consider emergent HBOT. This case highlights the importance of considering atypical causes of acute ischemic stroke.

12.
J Thorac Cardiovasc Surg ; 147(1): 186-191.e1, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24183336

RESUMEN

OBJECTIVES: Although frailty has recently been examined in various populations as a predictor of morbidity and mortality, its effect on thoracic aortic surgery outcomes has not been studied. The objective of the present study was to evaluate the role of frailty in predicting postoperative morbidity and mortality in patients undergoing proximal aortic replacement surgery. METHODS: A retrospective analysis of a prospectively maintained database was performed for all patients undergoing elective and nonelective proximal aortic operations (root, ascending aorta, and/or arch) at a single-referral institution from June 2005 to December 2012. A total of 581 patients underwent proximal aortic surgery, of whom 574 (98.8%) were included in the present analysis; 7 were excluded because of incomplete data. Frailty was evaluated using an index consisting of age >70 years, body mass index <18.5 kg/m(2), anemia, history of stroke, hypoalbuminemia, and total psoas volume in the bottom quartile of the population. One point was given for each criterion met to determine a frailty score of 0 to 6. Frailty was defined as a score of ≥2. Risk models for length of stay >14 days, discharge to other than home, 30-day composite major morbidity, 30-day composite major morbidity/mortality, and 30-day and 1-year mortality were calculated using multivariate regression modeling. RESULTS: Of the 574 patients, 148 (25.7%) were defined as frail (frailty score ≥2). The unadjusted 30-day/in-hospital and long-term outcomes were significantly worse for the frail versus nonfrail patients in all but 1 of the outcomes analyzed; no difference was found in the 30-day readmission rates between the 2 groups. In the multivariate model, a frailty score of ≥2 was associated with discharge to other than home and 30-day and 1-year mortality. CONCLUSIONS: Frailty, as defined using a 6-component frailty index, can serve as an independent predictor of discharge disposition and early and late mortality risk in patients undergoing proximal aortic surgery. These frailty markers, all of which are easily assessed preoperatively, could provide valuable information for patient counseling and risk stratification before proximal aortic replacement.


Asunto(s)
Aorta Torácica/cirugía , Anciano Frágil , Evaluación Geriátrica , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Vasculares/efectos adversos , Adulto , Factores de Edad , Anciano , Implantación de Prótesis Vascular/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , North Carolina , Alta del Paciente , Readmisión del Paciente , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Curr Cardiol Rep ; 15(6): 367, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23658010

RESUMEN

Aortic stenosis affects many people worldwide with a significant impact on morbidity and mortality with uncorrected, symptomatic aortic valve stenosis carrying mortality of 50% at one year. Degenerative calcific pathology, the most common cause of aortic stenosis, increases in prevalence with age; estimated prevalence of 5% in individuals over 75 years of age. Despite the malignant prognosis without valve replacement, many patients are not offered surgery due to advanced age and co-existing medical conditions; reported to be a third of symptomatic patients. In the last several years, transcatheter aortic valve replacement has emerged as an alternative treatment in patients with high or prohibitive open surgical risk. The PARTNER cohort B data, employing the Sapien valve, demonstrated a 20% absolute mortality benefit at one year compared with medical therapy. In this review, we provide an update of this technology and discuss patient selection, procedural planning, complications, and look toward the future of transcatheter heart valves in the treatment of aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Calcinosis/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Anciano de 80 o más Años , Envejecimiento , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/mortalidad , Calcinosis/fisiopatología , Angiografía Coronaria , Femenino , Fluoroscopía , Guías como Asunto , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Selección de Paciente , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
14.
Radiographics ; 33(1): 73-85, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23322828

RESUMEN

Advances in computed tomography (CT) scanners and electrocardiographic gating techniques have resulted in superior image quality of the ascending aorta and increased the use of CT angiography for evaluating the postoperative ascending aorta. Several abnormalities of the ascending aorta and aortic arch often require surgery, and various open techniques may be used to reconstruct the aorta, such as the Wheat procedure, in which both an ascending aortic graft and an aortic valve prosthesis are implanted; the Cabrol and modified Bentall procedures, in which a composite synthetic ascending aorta and aortic valve graft are placed; the Ross procedure, in which the aortic valve and aortic root are replaced with the patient's native pulmonary valve and proximal pulmonary artery; valve-sparing procedures such as the T. David-V technique, which leaves the native aortic valve intact; and more extensive arch repair procedures such as the elephant trunk and arch-first techniques, in which interposition or inclusion grafts are implanted, with or without replacement of the aortic valve. Normal postoperative imaging findings, such as hyperattenuating felt pledgets, prosthetic conduits, and reanastomosis sites, may mimic pathologic processes. Postoperative complications seen at CT angiography that require further intervention include pseudoaneurysms, anastomotic stenoses, dissections, and aneurysms. Radiologists must be familiar with these procedures and their imaging features to identify normal postoperative appearances and complications.


Asunto(s)
Angiografía/métodos , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Técnicas de Imagen Sincronizada Cardíacas , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Procedimientos Quirúrgicos Vasculares/métodos , Humanos
15.
Clin Imaging ; 36(5): 515-21, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22920355

RESUMEN

The purpose of this study was to investigate gray-scale inversion in nodule detection on chest radiography. Simulated nodules were superimposed randomly onto normal chest radiographs. Six radiologists interpreted 144 chest radiographs during three reading sessions: traditional presentation, inverted gray-scale, and a choice session allowing use of traditional and gray-scale inverted views. Sensitivity and specificity were used to assess accuracy based on presence or absence of a nodule. Gray-scale inversion and choice display sessions resulted in significantly higher nodule detection specificity and decreased sensitivity compared to traditional display. Gray-scale inversion may decrease false-positive nodule findings during chest X-ray interpretation.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Radiografía Torácica/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Competencia Clínica , Diagnóstico Diferencial , Humanos , Neoplasias Pulmonares/patología , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad , Nódulo Pulmonar Solitario/patología
16.
AJR Am J Roentgenol ; 199(1): W65-73, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22733933

RESUMEN

OBJECTIVE: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT. MATERIALS AND METHODS: Organ doses were measured using an anthropomorphic adult female phantom containing 30 metal oxide semiconductor field-effect transistor detectors on a dual-source MDCT scanner with two protocols: standard tube current modulation thoracic CT and organ-based dose modulation using a 120° radial arc. Radiochromic film measured the relative axial dose. Noise was measured to evaluate image quality. Breast tissue location across the anterior aspect of the thorax was retrospectively assessed in 100 consecutive thoracic MDCT examinations. RESULTS: There was a 17-47% decrease (p = < 0.05) in anterior thoracic organ dose and a maximum 52% increase (p = < 0.05) in posterior thoracic organ dose using organ-based dose modulation compared with tube current modulation. Effective dose (SD) for tube current modulation and organ-based dose modulation were 5.25 ± 0.36 mSv and 4.42 ± 0.30 mSv, respectively. Radiochromic film analysis showed a 30% relative midline anterior-posterior gradient. There was no statistically significant difference in image noise. Adult female breast tissue was located within an average anterior angle of 155° (123-187°). CONCLUSION: Organ-based dose modulation CT using an anterior 120° arc can reduce the organ dose in the anterior aspect of the thorax with a compensatory organ dose increase posteriorly without impairment of image quality. Laterally located breast tissue will have higher organ doses than medially located breast tissue when using organ-based dose modulation. The benefit of this dose reduction must be clinically determined on the basis of the relationship of the irradiated organs to the location of the prescribed radial arc used in organ-based dose modulation.


Asunto(s)
Exposición a Riesgos Ambientales/análisis , Dosis de Radiación , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Mama , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica , Dosificación Radioterapéutica , Estudios Retrospectivos , Tórax , Adulto Joven
17.
AJR Am J Roentgenol ; 198(5): 1132-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22528904

RESUMEN

OBJECTIVE: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding. MATERIALS AND METHODS: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield. Image noise was evaluated quantitatively with the SD of the attenuation value, and subjectively by two neuroradiologists. RESULTS: Organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield protocols reduced the thyroid dose by 28%, 33%, and 45%, respectively, compared with the use of automatic tube current modulation alone (p ≤ 0.005). Organ-based dose modulation also reduced the radiation dose to the ocular lens (33-47%) compared with the use of automatic tube current modulation (p ≤ 0.04). There was no significant difference in measured noise and subjective image quality between the protocols. CONCLUSION: Both organ-based dose modulation and thyroid shields significantly reduce the thyroid organ dose without degradation of subjective image quality compared with automatic tube current modulation. Organ-based dose modulation has the additional benefit of dose reduction to the ocular lens.


Asunto(s)
Dosis de Radiación , Protección Radiológica/instrumentación , Glándula Tiroides/efectos de la radiación , Tomografía Computarizada por Rayos X , Carga Corporal (Radioterapia) , Femenino , Humanos , Cuello , Fantasmas de Imagen , Radiometría , Programas Informáticos
18.
AJR Am J Roentgenol ; 198(3): 621-7, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22358002

RESUMEN

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol. RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols. CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.


Asunto(s)
Cuello/diagnóstico por imagen , Tomografía Computarizada Espiral/métodos , Adulto , Humanos , Fantasmas de Imagen , Dosis de Radiación , Protección Radiológica , Interpretación de Imagen Radiográfica Asistida por Computador , Valores de Referencia
19.
Radiology ; 262(2): 635-46, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22282185

RESUMEN

BACKGROUND: Pulmonary embolism (PE) is a leading cause of maternal mortality in the developed world. Along with appropriate prophylaxis and therapy, prevention of death from PE in pregnancy requires a high index of clinical suspicion followed by a timely and accurate diagnostic approach. METHODS: To provide guidance on this important health issue, a multidisciplinary panel of major medical stakeholders was convened to develop evidence-based guidelines for evaluation of suspected pulmonary embolism in pregnancy using the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) system. In formulation of the recommended diagnostic algorithm, the important outcomes were defined to be diagnostic accuracy and diagnostic yield; the panel placed a high value on minimizing cumulative radiation dose when determining the recommended sequence of tests. RESULTS: Overall, the quality of the underlying evidence for all recommendations was rated as very low or low with some of the evidence considered for recommendations extrapolated from studies of the general population. Despite the low quality evidence, strong recommendations were made for three specific scenarios: performance of chest radiography (CXR) as the first radiation-associated procedure; use of lung scintigraphy as the preferred test in the setting of a normal CXR; and performance of computed-tomographic pulmonary angiography (CTPA) rather than digital subtraction angiography (DSA) in a pregnant woman with a nondiagnostic ventilation-perfusion (V/Q) result. DISCUSSION: The recommendations presented in this guideline are based upon the currently available evidence; availability of new clinical research data and development and dissemination of new technologies will necessitate a revision and update.

20.
Am J Respir Crit Care Med ; 184(10): 1200-8, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22086989

RESUMEN

BACKGROUND: Pulmonary embolism (PE) is a leading cause of maternal mortality in the developed world. Along with appropriate prophylaxis and therapy, prevention of death from PE in pregnancy requires a high index of clinical suspicion followed by a timely and accurate diagnostic approach. METHODS: To provide guidance on this important health issue, a multidisciplinary panel of major medical stakeholders was convened to develop evidence-based guidelines for evaluation of suspected pulmonary embolism in pregnancy using the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) system. In formulation of the recommended diagnostic algorithm, the important outcomes were defined to be diagnostic accuracy and diagnostic yield; the panel placed a high value on minimizing cumulative radiation dose when determining the recommended sequence of tests. RESULTS: Overall, the quality of the underlying evidence for all recommendations was rated as very low or low, with some of the evidence considered for recommendations extrapolated from studies of the general population. Despite the low-quality evidence, strong recommendations were made for three specific scenarios: performance of chest radiography (CXR) as the first radiation-associated procedure; use of lung scintigraphy as the preferred test in the setting of a normal CXR; and performance of computed-tomographic pulmonary angiography (CTPA) rather than digital subtraction angiography (DSA) in a pregnant woman with a nondiagnostic ventilation-perfusion (V/Q) result. DISCUSSION: The recommendations presented in this guideline are based upon the currently available evidence; availability of new clinical research data and development and dissemination of new technologies will necessitate a revision and update.


Asunto(s)
Complicaciones Cardiovasculares del Embarazo/diagnóstico , Embolia Pulmonar/diagnóstico , Medios de Contraste/efectos adversos , Femenino , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Humanos , Pierna/irrigación sanguínea , Pierna/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Embarazo , Complicaciones Cardiovasculares del Embarazo/diagnóstico por imagen , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Dosis de Radiación , Radiografía Torácica/efectos adversos , Cintigrafía , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA