Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Int J Cardiol ; 248: 433-439, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28733074

RESUMEN

BACKGROUND: We aimed to evaluate the microvascular function in patients with microvascular angina (MVA) by assessing 1) the endothelial glycocalyx barrier properties using sublingual microscopy, and 2) the myocardial perfusion reserve using cardiovascular magnetic resonance (CMR) imaging. METHODS: Sublingual microscopy was performed in 13 MVA patients (angina pectoris, ST-depression on treadmill testing, normal coronary angiogram) and compared with 2 control groups of 13 volunteers and 14 patients with known obstructive coronary artery disease (CAD). To test the glycocalyx-mediated microvascular responsiveness, the erythrocyte perfused boundary region (PBR) was assessed at baseline and after nitroglycerin challenge. RESULTS: The baseline PBR of MVA patients was similar to controls with CAD (p=0.72), and larger than in volunteers (p=0.02). Only the volunteers demonstrated a significant increase in PBR after nitroglycerin (p=0.03). In the 13 MVA patients, adenosine stress CMR perfusion imaging was performed. Although a significant increase in myocardial perfusion was observed in both the subendocardium and subepicardium during stress, the subendocardial perfusion reserve was significantly lower (p=0.02). The PBR responsiveness of the sublingual microvasculature showed a strong correlation with the transmural myocardial perfusion reserve (r=0.86, p<0.001). CONCLUSIONS: Patients with MVA can be characterized by microvascular glycocalyx dysfunction using sublingual microscopy. The strong correlation between sublingual PBR responsiveness and myocardial perfusion reserve suggests that the glycocalyx may play an important role in the regulation of microvascular volume for myocardial perfusion and supports the concept of impaired glycocalyx barrier properties in MVA.


Asunto(s)
Circulación Coronaria/fisiología , Angina Microvascular/diagnóstico por imagen , Microvasos/diagnóstico por imagen , Anciano , Femenino , Humanos , Masculino , Angina Microvascular/fisiopatología , Microvasos/fisiopatología , Persona de Mediana Edad , Suelo de la Boca/irrigación sanguínea , Suelo de la Boca/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Estudios Prospectivos
2.
J Am Coll Cardiol ; 59(19): 1719-28, 2012 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-22554604

RESUMEN

OBJECTIVES: This study aimed to determine the diagnostic accuracy of the 3 most commonly used noninvasive myocardial perfusion imaging modalities, single-photon emission computed tomography (SPECT), cardiac magnetic resonance (CMR), and positron emission tomography (PET) perfusion imaging for the diagnosis of obstructive coronary artery disease (CAD). Additionally, the effect of test and study characteristics was explored. BACKGROUND: Accurate detection of obstructive CAD is important for effective therapy. Noninvasive myocardial perfusion imaging is increasingly being applied to gauge the severity of CAD. METHODS: Studies published between 1990 and 2010 identified by PubMed search and citation tracking were examined. A study was included if a perfusion imaging modality was used as a diagnostic test for the detection of obstructive CAD and coronary angiography as the reference standard (≥50% diameter stenosis). RESULTS: Of the 3,635 citations, 166 articles (n = 17,901) met the inclusion criteria: 114 SPECT, 37 CMR, and 15 PET articles. There were not enough publications on other perfusion techniques such as perfusion echocardiography and computed tomography to include these modalities into the study. The patient-based analysis per imaging modality demonstrated a pooled sensitivity of 88% (95% confidence interval [CI]: 88% to 89%), 89% (95% CI: 88% to 91%), and 84% (95% CI: 81% to 87%) for SPECT, CMR, and PET, respectively; with a pooled specificity of 61% (95% CI: 59% to 62%), 76% (95% CI: 73% to 78%), and 81% (95% CI: 74% to 87%). This resulted in a pooled diagnostic odds ratio (DOR) of 15.31 (95% CI: 12.66 to 18.52; I(2) 63.6%), 26.42 (95% CI: 17.69 to 39.47; I(2) 58.3%), and 36.47 (95% CI: 21.48 to 61.92; I(2) 0%). Most of the evaluated test and study characteristics did not affect the ranking of diagnostic performances. CONCLUSIONS: SPECT, CMR, and PET all yielded a high sensitivity, while a broad range of specificity was observed. SPECT is widely available and most extensively validated; PET achieved the highest diagnostic performance; CMR may provide an alternative without ionizing radiation and a similar diagnostic accuracy as PET. We suggest that referring physicians consider these findings in the context of local expertise and infrastructure.


Asunto(s)
Enfermedad de la Arteria Coronaria/metabolismo , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión Miocárdica/métodos , Miocardio/patología , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Humanos , Persona de Mediana Edad , Perfusión , Prevalencia , Estándares de Referencia , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA