Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
Front Cardiovasc Med ; 10: 1210725, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37876775

RESUMEN

Background: The aim of this study was to identify the predictive factors for adverse clinical events after surgery in patients with acute type A aortic dissection (AAAD), and to explore the predictive value of preoperative prognostic nutritional index (PNI) combined with D-dimer for these events. Methods: This study was a retrospective analysis of clinical data of 153 patients with AAAD who underwent emergency surgery at our center from January 2019 to January 2022. Patients were divided into adverse event group and non-adverse event group based on whether they experienced adverse clinical events after surgery. Univariate and multivariable logistic regression analyses were performed to identify the risk factors for adverse events, and the predictive efficacy was evaluated by the area under the receiver operating characteristic curve (ROC-AUC). Results: A total of 153 AAAD patients were included in the study, and were divided into the adverse event group (n = 46) and the non-adverse events group (n = 107) based on whether or not they experienced clinical adverse events after surgery. The optimal cutoff value was determined using ROC curves, and multivariate logistic regression analysis was performed. Ultimately, it was found that preoperative PNI < 42.45 and D-dimer > 15.05 were independent predictors of postoperative clinical adverse events in AAAD patients. The odd ratios (OR) value for preoperative PNI < 42.45 is 3.596 [95% Confidence Interval (CI): 1.508-8.923, p = 0.004], while the OR value for D-dimer > 15.05 is 7.572 [95% CI: 3.094-20.220, p < 0.001]. The combination of these two indicators has a high predictive value (AUC = 0.843, 95% CI: 0.774-0.912, p < 0.001) and is superior to using either variable alone. Conclusion: Preoperative PNI < 42.45 and D-dimer > 15.05 are independent predictive factors for postoperative adverse events during hospitalization in patients with AAAD. The combination of these two indicators can improve the predictive accuracy, which is superior to using either variable alone.

2.
Front Cardiovasc Med ; 10: 1086738, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36776260

RESUMEN

Background: Minimal research has been performed regarding total arch replacement through partial upper sternotomy in patients with acute type A aortic dissection who are obese, and the safety and feasibility of this procedure need to be further investigated. The present study investigated the potential clinical advantages of using a partial upper sternotomy versus a conventional full sternotomy for total arch replacement in patients who were obese. Methods: This was a retrospective study. From January 2017 to January 2020, a total of 65 acute type A aortic dissection patients who were obese underwent total arch replacement with triple-branched stent graft. Among them, 35 patients underwent traditional full sternotomy, and 30 patients underwent partial upper sternotomy. The perioperative clinical data and postoperative follow-up results of the two groups were collected, and the feasibility and clinical effect of partial upper sternotomy in total arch replacement were summarized. Results: The in-hospital mortality rates of the two groups were similar. The total operative time, cardiopulmonary bypass, aortic cross-clamp, cerebral perfusion, and deep hypothermic circulatory arrest times were also similar in both groups. The thoracic drainage and postoperative red blood cell transfusion volumes in the partial upper sternotomy group were significantly lower than those in the full sternotomy group. Mechanical ventilation time was shorter in the partial upper sternotomy group than that in the full sternotomy group. Additionally, the incidences of pulmonary infection, hypoxemia, and sternal diaphoresis were lower in the partial upper sternotomy group than those in the full sternotomy group. Conclusion: This study showed that total arch replacement surgery through a partial upper sternotomy in patients with acute type A aortic dissection who are obese is safe, effective, and superior to full sternotomy in terms of blood loss, postoperative blood transfusion, and respiratory complications.

3.
J Cardiothorac Surg ; 17(1): 179, 2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35922828

RESUMEN

OBJECTIVE: Controversial opinions exist for aortic valve replacement (AVR) through partial upper sternotomy in obese patients. Moreover, this study sought to investigate the potential clinical advantage of partial upper sternotomy aortic valve replacement (mini-AVR) over conventional full sternotomy aortic valve replacement (con-AVR) in obese patients. METHODS: This was a retrospective and observational study. From January 2015 to December 2020, a total of 184 obese [body mass index (BMI) ≥ 30 kg  m2] patients undergoing isolated primary AVR were included: 98 patients underwent conventional full sternotomy, and 86 patients underwent partial upper sternotomy. Propensity score (PS) matching was applied to eliminate the bassline imbalances in the mini-AVR and the con-AVR groups. RESULTS: After one-to-one propensity score matching, two groups of 60 patients were obtained. No in-hospital death occurred in the two groups. In addition, cardiopulmonary bypass time and total operative time were similar across the 2 groups, but the aortic cross-clamp time was significantly shorter in the con-AVR group (P = .0.022). The amount of mediastinal drainage at 48 h after surgery (P = 0.018) and postoperative blood transfusions (P = 0.014) were significantly lower in the mini-AVR group. There was no difference in ventilation time (P = .0.145), but a shorter intensive care unit stay time (P = 0.021) in the mini-AVR group. CONCLUSION: This study demonstrates that aortic valve replacement through a mini-AVR in obese patients is a safe and effective procedure. It outperformed con-AVR in terms of blood loss, blood product transfusion, and ICU stay.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Tiempo de Internación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Obesidad/complicaciones , Estudios Retrospectivos , Esternotomía/métodos , Resultado del Tratamiento
4.
J Thorac Cardiovasc Surg ; 164(4): 1045-1052, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-33223195

RESUMEN

BACKGROUND: Partial upper sternotomy (mini-ER) can be used in some adult cardiac surgeries but is seldom performed in the treatment of acute type A aortic dissection (AAAD). This study aimed to assess the feasibility and short-term outcomes of complete stent-graft replacement of the arch with triple-branched stent graft for AAAD through a mini-ER. METHODS: From 2015 to 2018, 254 patients with AAAD underwent complete stent-graft replacement of the arch with a triple-branched stent graft. Replacement was performed with conventional full sternotomy (con-ER) in 142 patients and with mini-ER in the other 112 patients. Using propensity score matching, the clinical data were compared between 100 patients in the mini-ER group and 100 patients in the con-ER group. RESULTS: After propensity score matching, there were no significant between-group differences in aortic cross-clamp time, cardiopulmonary bypass time, or total operative time. The amount of mediastinal drainage and number of red blood cell units were significantly lower in the mini-ER group compared with the con-ER group (P < .001). The intubation time was significantly shorter in the mini-ER group (P < .001). The treatment costs were also lower in the mini-ER group (P < .001). There were no significant between-group differences in 30-day mortality (9% vs 8%; P > .99) or postoperative complications. CONCLUSIONS: This study shows that extensive repair of AAAD through a mini-ER is feasible. It was superior to con-ER in terms of blood loss, postoperative ventilation time, and treatment costs.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Adulto , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Humanos , Estudios Retrospectivos , Stents , Esternotomía/efectos adversos , Resultado del Tratamiento
5.
J Interv Cardiol ; 2021: 5662697, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34456640

RESUMEN

PURPOSE: The objective of this investigation was to study the early efficacy of in situ fenestration with triple chimney technique for high-risk type A aortic dissection patients. METHODS: This study included 24 patients who were treated by in situ fenestration with TCT for high-risk TAAD between January 2018 and December 2019. Multiple comorbidities or preoperative critical conditions rendered patients ineligible for open surgery, but all patients that were evaluated and considered had to undergo operation. By analyzing the regular follow-up data, the early postoperative efficacy of the patients was evaluated. RESULTS: The average age of the 24 patients was 65.4 ± 9.3 years. The success rate of the operation was 100%, as all the patients were discharged successfully. There were no serious neurological complications or persistent endoleakage. The mean follow-up time was 21.4 ± 6.9 months. The patency rate of all branching stents was 100%, with no stent displacement, stenosis, or blockage observed. While none presented with type I endoleakage, one patient (4.2%) presented asymptomatic type II endoleakage around the left subclavian artery stent. Currently, 23 of the 24 patients remain alive. CONCLUSION: Initial results are encouraging with TCT for high-risk TAAD. However, due to its high selectivity and potential complexity related to surgical risks, the mid- and long-term efficacy of this technique remains unknown. For patients who are eligible for open heart surgery, we still recommend it be performed.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
6.
J Colloid Interface Sci ; 594: 812-823, 2021 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-33794403

RESUMEN

A novel and facile strategy is developed to tune parallel manganese dioxide (MnO2) to hollow parallel hydroxyl oxidize iron (FeOOH) replicas, which can exactly keep its original morphology. The key factors leading to the morphology-preserved transformation are the low-temperature and dropwise strategy via a serial of controlled experiments. Benefiting from the characteristics of parallel and hollow structures, the FeOOH replica delivers remarkable specific capacitance of 186.8F g-1 at 0.5 A g-1. The electrochemical performances delivered by the asymmetric supercapacitor (parallel MnO2//hollow parallel FeOOH) are much superior to those where conventional activated graphene or FeOOH nanoneedles are used as negative electrode materials. This can be attributed to the advantages of parallel nanostructure and high electrochemical matching effect of positive and negative electrode materials. The energy density is recorded up to 46.8 Wh kg-1 at the power density of 0.5 kW kg-1, while it still remains 20.7 Wh kg-1 with the maximum power density of 10 kW kg-1. Furthermore, this strategy shows great universality and can be broadened to almost all MnO2 related researches to synthesize ideal negative electrode materials with high structural and electrochemical matching effect, thus further enhances the electrochemical performances of as-prepared asymmetric supercapacitor devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA