Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
JACC Cardiovasc Interv ; 17(17): 2023-2037, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39260960

RESUMEN

BACKGROUND: Research on the role of transcatheter heart valve (THV) deformation and calcium distribution in patients with bicuspid aortic valves (BAVs) undergoing transcatheter aortic valve replacement (TAVR) remains limited. OBJECTIVES: The aim of this study was to evaluate the impact of THV deformation on clinical outcomes in individuals with BAVs undergoing TAVR and the influence of calcium on these outcomes. METHODS: In total, 229 consecutive patients with BAVs who underwent TAVR with balloon-expandable valves and had computed tomography (CT) performed 30 days post-TAVR were analyzed. Patients were stratified into 3 groups: group 1 (n = 125), with no THV underexpansion or eccentricity; group 2 (n = 69), with underexpansion or eccentricity; and group 3 (n = 35), with both. Calcium distribution was assessed using CT, and its associations with clinical outcomes, including all-cause mortality at 3 years and leaflet thrombosis at 30 days, were determined. A subgroup analysis of patients with type 1 BAVs was conducted. RESULTS: Group 3 exhibited higher rates of all-cause mortality than the other groups, along with the highest risk for hypoattenuated leaflet thickening at 30 days. Multivariate analysis identified annular and left ventricular outflow tract calcification as independent predictors of all-cause mortality and hypoattenuated leaflet thickening. In patients with type 1 BAVs, excessive calcification at the raphe and opposite leaflet were associated with all-cause mortality at 3 years. CONCLUSIONS: THV deformation post-TAVR was significantly linked to all-cause mortality in patients with BAVs. Annular and left ventricular outflow tract calcification correlated with increased risks for all-cause mortality and leaflet thrombosis. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Valvuloplastia con Balón , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Calcinosis/mortalidad , Valvuloplastia con Balón/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/mortalidad , Estudios Retrospectivos , Medición de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/etiología , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas
2.
Radiology ; 312(2): e240229, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-39136569

RESUMEN

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (r = 0.92; P < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; P = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm3 [95% LoA: -0.27 cm3, 0.19 cm3] and 0.02 cm3 [95% LoA: -0.14 cm3, 0.19 cm3], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almeida in this issue.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Angiografía por Tomografía Computarizada , Fibrosis , Humanos , Masculino , Estudios Prospectivos , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Persona de Mediana Edad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Fibrosis/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Anciano
3.
JACC Cardiovasc Interv ; 17(14): 1631-1651, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39048251

RESUMEN

Transcatheter aortic valve replacement (TAVR) has become more common than surgical aortic valve replacement since 2016, with over 200,000 procedures globally each year. As patients increasingly outlive their TAVR devices, managing these cases is a growing concern. Treatment options include surgical removal of the old TAVR device (transcatheter aortic valve [TAV] explant) or implantation of a new transcatheter aortic valve (redo TAV). Redo TAV is complex because of the unique designs of TAV devices; compatibility issues; and the need for individualized planning based on factors such as implant depth, shape, and coronary artery relationships. This review serves as a comprehensive guide for redo TAV, detailing the design characteristics of TAV devices, device compatibility, standardized terminology, and a structured approach for computed tomography analysis. It aims to facilitate decision making, risk identification, and achieving optimal outcomes in redo TAV procedures.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Riesgo , Toma de Decisiones Clínicas , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Terminología como Asunto , Valor Predictivo de las Pruebas
4.
Front Cardiovasc Med ; 11: 1374078, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38566964

RESUMEN

Introduction: Paravalvular leak (PVL) is a severe complication of transcatheter aortic valve replacement (TAVR) that can lead to poor outcomes. TAVR-in-TAVR is a promising treatment for PVL; however, reports on its safety or efficacy are limited. In this study, we aimed to investigate the clinical outcomes of TAVR-in-TAVR using balloon-expandable prostheses for PVLs after TAVR. Methods: We retrospectively analyzed data from patients who underwent TAVR-in-TAVR using balloon-expandable Sapien prostheses for PVL after an initial TAVR at our institution. The procedural success, in-hospital complications, all-cause mortality, and echocardiographic data for up to 2 years post-surgery were evaluated. Results: In total, 31 patients with a mean age of 81.1 ± 7.9 years and mean Society of Thoracic Surgeons score of 8.8 ± 5.4% were identified. The procedural success rate of TAVR-in-TAVR was 96.8% (30/31). No in-hospital deaths, cardiac tamponade, or conversion to sternotomy occurred. Re-intervention was performed in only one patient (3.2%) during hospitalization. The all-cause mortality rates at 30 days and 2 years were 0% and 16.1%, respectively. A significant reduction in the PVL rate was observed at 30 days compared with that at baseline (p < 0.01). Discussion: Our findings suggest that TAVR-in-TAVR using balloon-expandable prostheses is safe and effective for PVL after TAVR with low complication rates and acceptable long-term outcomes. Further studies with larger sample sizes are needed to confirm our findings.

5.
Am J Cardiol ; 207: 380-389, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37778227

RESUMEN

Few studies have compared the clinical outcomes between valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) with new-generation valves and re-operative surgical aortic valve replacement (Redo-SAVR). We compared the clinical outcomes of patients who underwent ViV-TAVR with those of patients who underwent Redo-SAVR at Cedars-Sinai Medical Center between 2015 and 2021. New-generation valves were used for ViV-TAVR. A propensity score-matched (PSM) analysis was performed to adjust for differences in baseline characteristics. The primary end point was all-cause mortality at 30 days and 2 years. In-hospital procedural and clinical outcomes were also compared between the groups. A total of 256 patients (140 who underwent ViV-TAVR and 116 who underwent Redo-SAVR) were eligible for PSM. In the unmatched cohort, patients in the ViV-TAVR group were older and had more co-morbidities than those in the Redo-SAVR group. After PSM, there were no significant differences in all-cause death between the ViV-TAVR and Redo-SAVR groups at 30 days (3.9% vs 2.6%, p = 0.65) or 2 years (6.5% vs 7.8%, p = 0.75). The incidences of stroke and heart failure rehospitalization were similar at 30 days and 2 years. The cumulative complication rates during hospitalization were significantly lower in the ViV-TAVR group than in the Redo-SAVR group (11.7% vs 28.6% p = 0.015). The long-term outcomes of ViV-TAVR using new-generation valves were similar to those of Redo-SAVR, although ViV-TAVR was associated with lower rates of in-hospital complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Reoperación , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Factores de Riesgo
6.
Am J Cardiol ; 208: 101-110, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37827014

RESUMEN

Multidetector computed tomography (MDCT) can provide valuable information for mitral assessment, but its role in transcatheter mitral edge-to-edge repair (TEER) planning has been poorly elucidated. We aimed to compare MDCT with 3-dimensional transesophageal echocardiography (3D-TEE) for TEER preprocedural evaluation. We analyzed the preprocedural MDCT and 3D-TEE of 108 consecutive patients with mitral regurgitation (MR) who underwent MitraClip implantation. The levels of agreement for the etiology and mechanism of MR, mitral calcification, mitral annulus, and mitral valve orifice area (MVOA) measurements were compared between MDCT and 3D-TEE data. Receiver-operating-characteristic curves were generated for mitral annulus area and MVOA using a low mean transmitral pressure gradient at discharge (<5 mm Hg) as the state variable, and the primary outcome of all-cause mortality or rehospitalization for heart failure at 1 year was compared between MDCT's and 3D-TEE's MVOA <4-cm2 cutoff. Good levels of agreement between MDCT and 3D-TEE were observed for determining the etiology (κ = 0.81) and mechanism (κ = 0.62) of MR but not for grading mitral calcification (κ = 0.31 to 0.35). The correlations between MDCT and 3D-TEE measurements were strong for mitral annulus area (r = 0.90) and good for MVOA (r = 0.73). Furthermore, no significant differences in the area under the receiver-operating-characteristic curve to predict low transmitral pressure gradient at discharge or the primary outcome at 1 year were detected between MDCT- and 3D-TEE-derived parameters (all p >0.05). In conclusion, in patients who underwent TEER with MitraClip, a high degree of agreement for comprehensive evaluation of MR and prediction of clinical outcomes between MDCT and 3D-TEE was observed.


Asunto(s)
Calcinosis , Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Tomografía Computarizada Multidetector , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Resultado del Tratamiento
7.
BMC Cardiovasc Disord ; 22(1): 445, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-36243693

RESUMEN

BACKGROUND: Success rate of transcatheter aortic valve replacement (TAVR) in aortic regurgitation (AR) patients is relatively low on account of the absence of calcified anchoring structures. Morphological classification and corresponding TAVR strategies for AR are lacking yet. METHODS: The AURORA study is a prospective, multicenter, single-arm cohort study to evaluate the safety and efficacy of transfemoral TAVR for severe AR in patients with high or prohibitive risk for surgery. Patients who are ≥ 65 years and diagnosed with severe pure AR as defined by the Echocardiographic Core Laboratory will be consecutively enrolled for further multidetector computed tomography (MDCT) scanning and multiplanar analyses. Based on a new anatomical classification and dual anchoring theory, patients will be classified into 4 types according to the level of the anchoring area. Types 1, 2 and 3 (at least 2 anchoring areas) will undergo the TAVR procedure with a domestic Chinese self-expanding valve (VitaFlow Valve, MicroPort, Shanghai, China), whereas type 4 (0 or 1 anchoring area) patients will be considered unsuitable for TAVR and will receive medical treatment. Our goal is to recruit 100 patients to account for 10% missing data or loss of patients to follow-up. Procedural, 30-day, 6-month and 12-month outcomes will be assessed according to Valve Academic Research Consortium-3 criteria. DISCUSSION: The AURORA study will establish a new AR anatomical classification based on dual anchoring theory through MDCT multiplanar measurement and assess the safety and efficacy of TAVR guided by this new classification and strategy in AR patients. TRIAL REGISTRATION: This Study was registered at Chinses Clinical Trial Registry. The registration number: ChiCTR2200055415; The date of registration: 9, January 2022; The URL of the registration: http://www.chictr.org.cn/showproj.aspx?proj=141209 .


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , China , Estudios de Cohortes , Humanos , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
J Invasive Cardiol ; 33(8): E586-E590, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34280891

RESUMEN

OBJECTIVES: To describe the use of orbital atherectomy to prepare iliofemoral vessels for large-bore access prior to transcatheter aortic valve replacement (TAVR). BACKGROUND: Transfemoral (TF)-TAVR has been shown to be at least equivalent to surgery. Nevertheless, many patients do not qualify for the TF approach due to severe iliofemoral occlusive disease. The use of an atherectomy device in order to facilitate TF-TAVR has only been reported in case reports. METHODS: We performed 1000 TAVR procedures from June 2017 to October 2019. Patient demographics, procedural characteristics, computed tomography characteristics, and short-term outcomes were recorded. Hostile access was defined as luminal size <5 mm, or <5.5 mm along with the presence of >270° calcification. The primary endpoint was the ability to successfully deliver a transcatheter valve via the intended pretreated access site. RESULTS: During the study period, 6 subjects (0.6%) required alternative access and 68 patients (6.8%) were considered to have a hostile iliofemoral anatomy that required vessel preparation prior to TAVR. Forty-eight patients (70.6%) had angioplasty only and 20 patients (29.4%) required atherectomy and angioplasty. Out of 20 patients treated with atherectomy, successful TF delivery of the valve was achieved in 19 patients (95%). There was no in-hospital mortality or stroke. There were no perforations. One subject required placement of a self-expandable stent due to severe dissection. CONCLUSION: Orbital atherectomy used for vessel preparation is a safe and very effective technique to facilitate TF-TAVR in patients with hostile peripheral anatomy.


Asunto(s)
Estenosis de la Válvula Aórtica , Aterectomía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
9.
J Am Coll Cardiol ; 75(24): 3003-3015, 2020 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-32553252

RESUMEN

BACKGROUND: Subclinical leaflet thrombosis, characterized by hypoattenuated leaflet thickening (HALT) and reduced leaflet motion observed on 4-dimensional computed tomography (CT), may represent a form of bioprosthetic valve dysfunction. OBJECTIVES: The U.S. Food and Drug Administration mandated CT studies to understand the natural history of this finding, differences between transcatheter and surgical valves, and its association with valve hemodynamics and clinical outcomes. METHODS: The PARTNER 3 (The Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low-Risk Patients With Aortic Stenosis) CT substudy randomized 435 patients with low-surgical-risk aortic stenosis to undergo transcatheter aortic valve replacement (n = 221) or surgery (n = 214). Serial 4-dimensional CTs were performed at 30 days and 1 year and were analyzed independently by a core laboratory. RESULTS: The incidence of HALT increased from 10% at 30 days to 24% at 1 year. Spontaneous resolution of 30-day HALT occurred in 54% of patients at 1 year, whereas new HALT appeared in 21% of patients at 1 year. HALT was more frequent in transcatheter versus surgical valves at 30 days (13% vs. 5%; p = 0.03), but not at 1 year (28% vs. 20%; p = 0.19). The presence of HALT did not significantly affect aortic valve mean gradients at 30 days or 1 year. Patients with HALT at both 30 days and 1 year, compared with those with no HALT at 30 days and 1 year, had significantly increased aortic valve gradients at 1 year (17.8 ± 2.2 mm Hg vs. 12.7. ± 0.3 mm Hg; p = 0.04). CONCLUSIONS: Subclinical leaflet thrombosis was more frequent in transcatheter compared with surgical valves at 30 days, but not at 1 year. The impact of HALT on thromboembolic complications and structural valve degeneration needs further assessment.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/epidemiología , Trombosis/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Canadá/epidemiología , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Trombosis/diagnóstico por imagen , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estados Unidos/epidemiología
10.
Circ Cardiovasc Interv ; 12(11): e007938, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31694412

RESUMEN

BACKGROUND: No data exist about the characteristics of infective endocarditis (IE) post-transcatheter aortic valve replacement (TAVR) according to transcatheter valve type. We aimed to determine the incidence, clinical characteristics, and outcomes of patients with IE post-TAVR treated with balloon-expandable valve (BEV) versus self-expanding valve (SEV) systems. METHODS: Data from the multicenter Infectious Endocarditis After TAVR International Registry was used to compare IE patients with BEV versus SEV. RESULTS: A total of 245 patients with IE post-TAVR were included (SEV, 47%; BEV, 53%). The timing between TAVR and IE was similar between groups (SEV, 5.5 [1.2-15] months versus BEV, 5.3 [1.7-11.4] months; P=0.89). Enterococcal IE was more frequent in the SEV group (36.5% versus 15.4%; P<0.01), and vegetation location differed according to valve type (stent frame, SEV, 18.6%; BEV, 6.9%; P=0.01; valve leaflet, SEV, 23.9%; BEV, 38.5%; P=0.01). BEV recipients had a higher rate of stroke/systemic embolism (20.0% versus 8.7%, adjusted OR: 2.46, 95% CI: 1.04-5.82, P=0.04). Surgical explant of the transcatheter valve (SEV, 8.7%; BEV, 13.8%; P=0.21), and in-hospital death at the time of IE episode (SEV, 35.6%; BEV, 37.7%; P=0.74) were similar between groups. After a mean follow-up of 13±12 months, 59.1% and 54.6% of the SEV and BEV recipients, respectively, had died (P=0.66). CONCLUSIONS: The characteristics of IE post-TAVR, including microorganism type, vegetation location, and embolic complications but not early or late mortality, differed according to valve type. These results may help to guide the diagnosis and management of IE and inform future research studies in the field.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón , Endocarditis Bacteriana/epidemiología , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Toma de Decisiones Clínicas , Remoción de Dispositivos , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/mortalidad , Endocarditis Bacteriana/cirugía , Femenino , Humanos , Incidencia , Masculino , Selección de Paciente , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Infecciones Relacionadas con Prótesis/cirugía , Sistema de Registros , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 94(6): 812-817, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-31062487

RESUMEN

BACKGROUND: Thrombocytopenia after transcatheter aortic valve replacement (TAVR) is associated with adverse clinical outcomes. Whether preprocedural P2Y12 inhibition prevents postprocedural thrombocytopenia is uncertain. METHODS: This retrospective analysis identified consecutive patients (n = 266) undergoing TAVR between November 2016 and July 2017. Preprocedure clopidogrel load ≥300 mg or maintenance P2Y12 inhibitor therapy defined preprocedural P2Y12 inhibition. Patients who did not consent for the registry (n = 8), with baseline severe thrombocytopenia (<90 × 103 platelets/µL; n = 14), or without baseline platelet count (n = 4) were excluded. The primary outcome was proportion of patients who developed >20% decrease in platelet count from baseline to day 1 post-TAVR. RESULTS: Patients with (n = 134) versus without (n = 106) preprocedural P2Y12 inhibition had no differences in platelet count at baseline. Patients with preprocedural P2Y12 inhibition had a significantly lower proportion of the primary outcome (34.3% vs. 57.5%, p = .001) and a lower absolute decrease in platelet count (32.8 × 103 vs. 45.8 × 103 platelet/µL, p = .01). Of patients without baseline thrombocytopenia (n = 198), a numerically lower rate of patients with versus without preprocedural P2Y12 inhibition developed thrombocytopenia on day 1 post-TAVR (25.5% vs. 36.4%, p = .1). CONCLUSION: Patients who received preprocedural P2Y12 inhibition prior to TAVR were less likely to demonstrate a decrease in platelet count after TAVR. Prospective studies to further understand the clinical implication of these findings are warranted.


Asunto(s)
Plaquetas/efectos de los fármacos , Clopidogrel/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Receptores Purinérgicos P2Y12/efectos de los fármacos , Trombocitopenia/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Plaquetas/metabolismo , Clopidogrel/efectos adversos , Femenino , Humanos , Masculino , Recuento de Plaquetas , Antagonistas del Receptor Purinérgico P2Y/efectos adversos , Receptores Purinérgicos P2Y12/sangre , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Trombocitopenia/sangre , Trombocitopenia/diagnóstico , Trombocitopenia/etiología , Resultado del Tratamiento
12.
JACC Cardiovasc Interv ; 12(2): 182-193, 2019 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-30678797

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the predictors of left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR). BACKGROUND: LVOT obstruction is a major concern with TMVR, but limited data exist regarding its predictors and impact on outcomes. METHODS: Patients with pre-procedural multidetector row computed tomography (MDCT) undergoing TMVR for failed mitral bioprosthetic valves (valve-in-valve), annuloplasty rings (valve-in-ring), and mitral annular calcification (valve-in-MAC) were included in this study. Echocardiographic and procedural characteristics were recorded, and comprehensive assessment with MDCT was performed to identify the predictors of LVOT obstruction (defined as an increment of mean LVOT gradient ≥10 mm Hg from baseline). The new LVOT (neo-LVOT) area left after TMVR was estimated by embedding a virtual valve into the mitral annulus on MDCT, simulating the procedure. RESULTS: Among 194 patients with pre-procedural MDCT undergoing TMVR (valve-in-valve, 107 patients; valve-in-ring, 50 patients; valve-in-MAC, 37 patients), LVOT obstruction was observed in 26 patients (13.4%), with a higher rate after valve-in-MAC than valve-in-ring and valve-in-valve (54.1% vs. 8.0% vs. 1.9%; p < 0.001). Patients with LVOT obstruction had significantly higher procedural mortality compared with those without LVOT obstruction (34.6% vs. 2.4%; p < 0.001). Receiver-operating characteristic curve analysis showed that an estimated neo-LVOT area ≤1.7 cm2 predicted LVOT obstruction with sensitivity of 96.2% and specificity of 92.3%. CONCLUSIONS: LVOT obstruction after TMVR was associated with higher procedural mortality. A small estimated neo-LVOT area was significantly associated with LVOT obstruction after TMVR and may help identify patients at high risk for LVOT obstruction.


Asunto(s)
Calcinosis/cirugía , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Obstrucción del Flujo Ventricular Externo/etiología , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/fisiopatología , Tomografía Computarizada Multidetector , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/mortalidad , Obstrucción del Flujo Ventricular Externo/fisiopatología
13.
J Invasive Cardiol ; 30(11): 421-427, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30373952

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in cases with left ventricular outflow tract calcification (LVOT-CA) remains a challenging procedure. The aim of this study was to compare the early outcomes of patients undergoing TAVR in LVOT-CA with new-generation devices vs early-generation devices. METHODS: Between January 2014 and December 2016, a total of 433 patients with severe aortic stenosis who had a preprocedural multidetector computed tomography underwent TAVR in a LVOT-CA. After propensity matching, data from 119 patients in each group were analyzed. TAVR endpoints and adverse events were defined according to the Valve Academic Research Consortium-2. RESULTS: Compared with early-generation devices (Edwards Sapien/Sapien XT/CoreValve), new-generation devices (Sapien 3/Evolut R) had significantly lower incidence of mild-moderate paravalvular leak (PVL) (1.7% new vs 7.6% early; P=.03), tended to have lower incidence of moderate or severe PVL (5.0% new vs 11.8% early; P=.06), had no significant difference in device success (89.1% new vs 83.2% early; P=.19), and had a significantly higher early safety rate at 30 days (93.3% new vs 84.9% early; P=.04). For cardiac conduction disturbances, new-generation and early-generation devices had similarly high rates of new permanent pacemaker implantation (16.8% new vs 15.1% early; P=.72), whereas the number of patients who developed new-onset left bundle-branch block (LBBB) were significantly higher in those with new-generation devices (16.0% new vs 6.7% early; P=.03). CONCLUSION: In the setting of LVOT-CA, patients with new-generation devices compared to those with early-generation devices had acceptable clinical outcomes except for cardiac conduction disturbances, especially in new-onset LBBB.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Obstrucción del Flujo Ventricular Externo/cirugía , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Calcinosis/complicaciones , Calcinosis/diagnóstico , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico , Obstrucción del Flujo Ventricular Externo/etiología
14.
Am J Cardiol ; 120(11): 2017-2024, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28941599

RESUMEN

Left ventricular outflow tract (LVOT) calcium is known to be associated with adverse procedural outcomes after transcatheter aortic valve implantation (TAVI), yet its effect on midterm outcomes has not been previously investigated. The aim of this study was to determine the influence of LVOT calcium on 2-year mortality after TAVI. A total of 537 consecutive patients underwent TAVI and 2 groups were established, stratified based on the severity of the LVOT calcium. The primary outcome was 2-year overall survival rate. The ≥moderate LVOT calcium group included 107 patients (19.9%) and the remaining 430 patients (80.1%) were included in the ≤mild LVOT calcium group. After a median follow-up of 717 days (interquartile range 484 to 828), the Kaplan-Meier analysis revealed that the 2-year overall survival probability was significantly lower in the ≥moderate LVOT calcium group than in the ≤mild LVOT calcium group (log-rank p = 0.001). On a Cox hazard model, ≥moderate LVOT calcium was associated with increased all-cause mortality after TAVI (hazard ratio 1.74, p = 0.009). In the subgroup analysis, based on valve designs, SAPIEN 3-TAVI done in the setting of ≥moderate LVOT calcium had a relatively similar survival probability as those of ≤mild LVOT calcium (log-rank p = 0.18), which is in contrast with older generation valves (log-rank p = 0.001). In conclusion, patients with ≥moderate LVOT calcium were shown to have a lower survival probability in the midterm follow-up after TAVI, compared with those with ≤mild LVOT calcium. Patients with high-grade LVOT calcium should be monitored with longer-term follow-ups after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Calcinosis/complicaciones , Calcio/metabolismo , Ventrículos Cardíacos/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Obstrucción del Flujo Ventricular Externo/etiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Calcinosis/diagnóstico , Calcinosis/mortalidad , Ecocardiografía Tridimensional , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Estados Unidos/epidemiología , Obstrucción del Flujo Ventricular Externo/diagnóstico , Obstrucción del Flujo Ventricular Externo/mortalidad
15.
Eur Heart J Cardiovasc Imaging ; 18(6): 639-647, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28369223

RESUMEN

AIMS: High aortic valve calcification (AVC) assessed with CT may be used to differentiate between severe and non-severe aortic stenosis (AS). Nonetheless, in some cases patients with low calcification are diagnosed with haemodynamically severe AS. The prevalence, mechanism of valve stenosis and implications for transcatheter aortic valve implantation (TAVI) of low AVC severe AS remain unclear. We assessed the clinical and haemodynamic characteristics and the outcome of patients with severe AS and low AVC that undergo TAVI. METHODS AND RESULTS: Ninety-three patients that had low CT aortic valve calcification score (AVCS) were compared to 470 patients with high AVCS. High gradient severe AS was found among 53.8% (50/93) of the patients with low AVCS vs. 86% (404/470) of the patients with high AVCS (P < 0.001). Device success rate was similar between both groups. There were significantly lower rates of postprocedural paravalvular regurgitation (PVR) in the low AVCS group (≥ mild PVR: 12.9% vs. 23.6%; P = 0.03). Overall, there were only two cases (0.4%) of valve embolization in patients with high AVCS and 1 (1.1%) in patients with low AVCS (P = 0.42). Thirty-day mortality and major complications were similar between groups. CONCLUSION: Balloon-expandable TAVI in patients with a mildly calcified aortic valve was not associated with increased risk of valve embolization or mortality. We demonstrated high device success and lower rates of PVR for these patients. These findings suggest that in patients with evidence of haemodynamically severe AS at echocardiography, the presence of low ACVS at CT should not preclude the consideration of TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Estudios de Cohortes , Ecocardiografía Doppler/métodos , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Modelos de Riesgos Proporcionales , Análisis de Regresión , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
16.
JACC Cardiovasc Imaging ; 10(10 Pt A): 1139-1147, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28412434

RESUMEN

OBJECTIVES: This study sought to develop a robust and definitive risk model for new permanent pacemaker implantation (PPMI) after SAPIEN 3 (third generation balloon expandable valve) (Edwards Lifesciences, Irvine, California) transcatheter aortic valve replacement (third generation balloon expandable valve TAVR), including calcification in the aortic-valvular complex (AVC). BACKGROUND: The association between calcium in the AVC and need for PPMI is poorly delineated after third generation balloon expandable valve TAVR. METHODS: At Cedars-Sinai Heart Institute in Los Angeles, California, a total of 240 patients with severe aortic stenosis underwent third generation balloon expandable valve TAVR and had contrast computed tomography. AVC was characterized precisely by leaflet sector and region. RESULTS: The total new PPMI rate was 14.6%. On multivariate analysis for predictors of PPMI, pre-procedure third generation balloon expandable valve TAVR, right bundle branch block (RBBB), shorter membranous septum (MS) length, and noncoronary cusp device-landing zone calcium volume (NCC-DLZ CA) were included. Predictive probabilities were generated using this logistic regression model. If 3 pre-procedural risk factors were present, the c-statistic of the model for PPMI was area under the curve of 0.88, sensitivity of 77.1%, and specificity of 87.1%; this risk model had high negative predictive value (95.7%). The addition of the procedural factor of device depth to the model, with the parameter of difference between implantation depth and MS length, combined with RBBB and NCC-DLZ CA increased the c-statistic to 0.92, sensitivity to 94.3%, specificity to 83.8%, and negative predictive value to 98.8% CONCLUSIONS: By using a precise characterization of distribution of calcification in the AVC in a single-center, retrospective study, NCC-DLZ CA was found to be an independent predictor of new PPMI post-third generation balloon expandable valve TAVR. The findings also reinforce the importance of short MS length, pre-existing RBBB, and ventricular implantation depth as important synergistic PPMI risk factors. This risk model will need validation by future prospective multicenter studies.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Calcinosis/cirugía , Estimulación Cardíaca Artificial , Técnicas de Apoyo para la Decisión , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Bases de Datos Factuales , Femenino , Humanos , Modelos Logísticos , Los Angeles , Masculino , Tomografía Computarizada Multidetector , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
17.
EuroIntervention ; 12(18): e2177-e2185, 2017 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-28117281

RESUMEN

AIMS: The impact of left ventricular outflow tract calcification (LVOT-CA) on SAPIEN 3 transcatheter aortic valve replacement (S3-TAVR) is not well understood. The aims of the present study were to determine optimal device sizing for S3-TAVR in patients with or without LVOT-CA and to evaluate the influence of residual paravalvular leak (PVL) on survival after S3-TAVR in these patients. METHODS AND RESULTS: This study analysed 280 patients (LVOT-CA=144, no LVOT-CA=136) undergoing S3-TAVR. Optimal annular area sizing was defined as % annular area sizing related to lower rates of ≥mild PVL. Annular area sizing was determined as follows: (prosthesis area/CT annulus area-1)×100. Overall, ≥mild PVL was present in 25.7%. Receiver operating characteristic curve analysis for prediction of ≥mild PVL in patients with LVOT-CA showed that 7.2% annular area sizing was identified as the optimal threshold (area under the curve [AUC] 0.71). Conversely, annular area sizing for no LVOT-CA appeared unrelated to PVL (AUC 0.58). Aortic annular injury was seen in four patients (average 15.5% annular area oversizing), three of whom had LVOT-CA. Although there was no difference in one-year survival between patients with ≥mild PVL and without PVL (log-rank p=0.91), subgroup analysis demonstrated that patients with ≥moderate LVOT-CA who had ≥mild PVL had lower survival compared to patients with ≥mild PVL and none or mild LVOT-CA (log-rank p=0.010). CONCLUSIONS: In the setting of LVOT-CA, an optimally sized S3 valve is required to reduce PVL and to increase survival following TAVR.


Asunto(s)
Válvula Aórtica/anatomía & histología , Calcinosis/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Obstrucción del Flujo Ventricular Externo
18.
Int Heart J ; 58(1): 56-62, 2017 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-28100877

RESUMEN

Severe device landing zone calcification (DLZ-CA) predicted paravalvular leak (PVL) and post-dilatation (PD) after transcatheter aortic valve implantation (TAVI). The aim of this study was to determine the influence of DLZ-CA on PVL or PD rates after SAPIEN XT (XT) versus CoreValve (CV).We analyzed patients undergoing TAVI who had severe DLZ-CA. Severe DLZ-CA defined the upper left ventricular outflow tract calcification; the cross-sectional region 2 mm inferior to the annular plane. PVL was evaluated at 30days using transthoracic echocardiography. Overall, 133 patients had XT-TAVI and the remaining 41 patients had CV-TAVI. Two patients had annulus injury in the XT group (oversizing 20.2% and 20.5% for two XT cases). PD was less frequently performed in the XT group (34.1% versus 12.8%; P = 0.002), but PVL rates were similar between both groups (42.1% versus 41.5% for the XT and CV groups, respectively; P = 0.94). Importantly, excessive oversizing or the degree of filling volume was not associated with decreased PVL after XT-TAVI (P = non-significant for all). On multivariate analysis, CV-TAVI was found to be one of the independent predictors of need for PD (Odds ratio 3.63, 95% confidence interval 1.55 to 8.53, P = 0.003).In the setting of severe DLZ-CA, XT and CV have similar rates of PVL but XT had less need for PD. Excessive oversizing with XT carries a risk of root injury which could be further increased by DLZ-CA.


Asunto(s)
Válvula Aórtica , Calcinosis/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Dilatación , Femenino , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Humanos , Masculino , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación
19.
Eur Heart J ; 38(16): 1194-1203, 2017 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-28039339

RESUMEN

AIMS: Calcified aortic stenosis (AS) and mitral annular calcification (MAC) have certain similar etiology and pathophysiological mechanisms. MAC is frequently encountered in pre-procedural computed tomography (CT) imaging of patients that undergo transcatheter aortic valve replacement (TAVR), but its prognostic implications for these patients have not been thoroughly investigated. This study sought to evaluate the prevalence of MAC among patients with severe AS and to assess the clinical implications of MAC on these patients during and following TAVR. METHODS AND RESULTS: Consecutive patients that underwent TAVR were compared according to the existence of MAC and its severity in pre-TAVR CT scans. From the entire cohort of 761 patients, 49.3% had MAC, and 50.7% did not have MAC. Mild MAC was present in 231 patients (30.4%), moderate MAC in 72 patients (9.5%), and severe MAC in 72 patients (9.5%). Thirty-day mortality and major complications were similar between patients with and without MAC. In a multivariable survival analysis, severe MAC was found to be an independent strong predictor of overall mortality following TAVR (all-cause mortality: hazards ratio [HR] 1.95, 95% confidence interval [CI] 1.24-3.07, P = 0.004; cardiovascular mortality: HR 2.35, 95% CI 1.19-4.66; P = 0.01). Severe MAC was also found to be an independent strong predictor of new permanent pacemaker implantation (PPI) after TAVR (OR 2.83, 95% CI 1.08-7.47; P = 0.03). CONCLUSION: Half of the patients with severe AS evaluated for TAVR were found to have MAC. Severe MAC is associated with increased all-cause and cardiovascular mortality and with conduction abnormalities following TAVR and should be included in future risk stratification models for TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Mitral/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/complicaciones , Calcinosis/mortalidad , Calcinosis/cirugía , Femenino , Humanos , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Calcificación Vascular/complicaciones , Calcificación Vascular/mortalidad , Calcificación Vascular/cirugía
20.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-27623462

RESUMEN

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Asunto(s)
Endocarditis Bacteriana/epidemiología , Endocarditis/etiología , Mortalidad Hospitalaria/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Edad , Anciano , Endocarditis Bacteriana/etiología , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca , Humanos , Masculino , Oportunidad Relativa , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/etiología , Staphylococcus aureus , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA