Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Eur Heart J Case Rep ; 5(6): ytab128, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34222778

RESUMEN

BACKGROUND: Intracoronary imaging techniques have allowed characterizing atherosclerotic plaques morphologically in patients with the acute coronary syndrome (ACS). Although the main feature described is plaque rupture, the use of optical coherence tomography has made it possible to objectify that the eroded plaque is not uncommon in this setting. CASE SUMMARY: We presented a case of a 45-year-old man with active smoking and cocaine user, admitted to the emergency department for chest pain. The electrocardiogram showed ST-segment elevation myocardial infarction (STEMI) in the inferior leads. Emergent coronary angiography was performed, showing thrombotic occlusion of mid-distal right coronary artery. After successful thromboaspiration, no areas of significant angiographic stenosis were observed. Optical coherence tomography imaging at the occlusion site revealed an eroded plaque and a remaining small thrombusburden. Conservative management without stent implantation was decided. Treatments consisted of an acute phase glycoprotein IIb/IIIa inhibitor and subsequently dual antiplatelet therapy with Aspirin (ASA) and Ticagrelor 90 mg b.i.d. for 12 months. The patient remains asymptomatic and uneventful at 9-month follow-up. DISCUSSION: Young age, history of active smoking, and cocaine use are common clinical features in patients with ACS due to an eroded plaque. These patients frequently display a STEMI with the involvement of a single coronary vessel. Optical coherence tomography imaging aids to a precise diagnosis and to define a proper treatment.

2.
JACC Cardiovasc Interv ; 13(17): 1983-1996, 2020 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-32912458

RESUMEN

OBJECTIVES: This study aimed to evaluate the safety and mid-term efficacy of transcatheter aortic valve replacement (TAVR) in the setting of aortic valve (AV) infective endocarditis (IE) with residual lesion despite successful antibiotic treatment. BACKGROUND: Patients with AV-IE presenting residual lesion despite successful antibiotic treatment are often rejected for cardiac surgery due to high-risk. The use of TAVR following IE is not recommended. METHODS: This was a multicenter retrospective study across 10 centers, gathering baseline, in-hospital, and 1-year follow-up characteristics of patients with healed AV-IE treated with TAVR. Matched comparison according to sex, EuroSCORE, chronic kidney disease, left ventricular function, prosthesis type, and valve-in-valve procedure was performed with a cohort of patients free of prior IE treated with TAVR (46 pairs). RESULTS: Among 2,920 patients treated with TAVR, 54 (1.8%) presented with prior AV-IE with residual valvular lesion and healed infection. They had a higher rate of multivalvular disease and greater surgical risk scores. A previous valvular prosthesis was more frequent than a native valve (50% vs. 7.5%; p < 0.001). The in-hospital and 1-year mortality rates were 5.6% and 11.1%, respectively, comparable to the control cohort. After matching, the 1-year III to IV aortic regurgitation rate was 27.9% (vs. 10%; p = 0.08) and was independently associated with higher mortality. There was only 1 case of IE relapse (1.8%); however, 18% of patients were complicated with sepsis, and 43% were readmitted due to heart failure. CONCLUSIONS: TAVR is a safe therapeutic alternative for residual valvular lesion after successfully healed AV-IE. At 1-year follow-up, the risk of IE relapse was low and mortality rate did not differ from TAVR patients free of prior IE, but one-fourth presented with significant aortic regurgitation and >50% required re-admission.


Asunto(s)
Válvula Aórtica/cirugía , Endocarditis Bacteriana/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/microbiología , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/mortalidad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/microbiología , Enfermedades de las Válvulas Cardíacas/mortalidad , Prótesis Valvulares Cardíacas/efectos adversos , Mortalidad Hospitalaria , Humanos , Masculino , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA