Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
J Cardiothorac Surg ; 19(1): 329, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867224

RESUMEN

Iatrogenic aortic regurgitation secondary to leaflet injury is a rare complication of mitral valve surgery. For the first time, we report a patient who had progressive aortic regurgitation due to non-coronary leaflet perforation after robotic mitral valve repair and required aortic valve repair 18 months after this initial surgery. As in our case, aortic regurgitation after mitral valve surgery may remain undiagnosed on intraoperative transesophageal echocardiography or undetected until the patient's discharge due to gradual enlargement of very small perforations over the postoperative course.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Ecocardiografía Transesofágica , Enfermedad Iatrogénica , Insuficiencia de la Válvula Mitral , Válvula Mitral , Procedimientos Quirúrgicos Robotizados , Humanos , Válvula Mitral/cirugía , Procedimientos Quirúrgicos Robotizados/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Femenino
2.
J Vasc Surg Cases Innov Tech ; 7(2): 335-338, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34041423

RESUMEN

Fibrosing mediastinitis can lead to superior vena cava obstruction by generating a fibroinflammatory mass in the mediastinum. Surgical caval reconstruction with conduits could be indicated for cases of unsuccessful or technically unfeasible endovascular stenting and angioplasty. The use of cryopreserved vascular homografts seems to be better than prosthetic conduits for mid- and long-term patency, as was observed in the case we have described in the present report.

3.
Ann Thorac Surg ; 109(3): e219-e221, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31589855

RESUMEN

Repeat cardiac operations are common among patients with complex congenital heart disease. Inadvertent cardiotomy during redo sternotomy can increase intraoperative time and mortality. Establishing extracorporeal circulation before resternotomy may render redo congenital cardiac surgery cases safer and more expeditious. In the present report, we describe the technique of preemptive cannulation of the abdominal aorta (or right common iliac artery) and inferior vena cava. This approach may be a useful when femoral vessels are occluded owing to many catheterizations or prior cannulations. In our practice, no reentry injuries or other complications related to abdominal vessel cannulation have occurred.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Cardiopatías Congénitas/cirugía , Esternotomía , Aorta Abdominal , Cateterismo , Preescolar , Humanos , Arteria Ilíaca , Masculino , Cuidados Preoperatorios , Reoperación , Esternotomía/métodos , Vena Cava Inferior
4.
Pediatr Cardiol ; 40(6): 1105-1112, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31214731

RESUMEN

Tetralogy of Fallot (ToF) is one of the most common cyanotic congenital heart defects. We sought to summarize all available data regarding the epidemiology and perioperative outcomes of syndromic ToF patients. A PRISMA-compliant systematic literature review of PubMed and Cochrane Library was performed. Twelve original studies were included. The incidence of syndromic ToF was 15.3% (n = 549/3597). The most prevalent genetic syndromes were 22q11.2 deletion (47.8%; 95% CI 43.4-52.2) and trisomy 21 (41.9%; 95% CI 37.7-46.3). Complete surgical repair was performed in 75.2% of the patients (n = 161/214; 95% CI 69.0-80.1) and staged repair in 24.8% (n = 53/214; 95 CI 19.4-30.9). Relief of RVOT obstruction was performed with transannular patch in 64.7% (n = 79/122; 95% CI 55.9-72.7) of the patients, pulmonary valve-sparing technique in 17.2% (n = 21/122; 95% CI 11.5-24.9), and RV-PA conduit in 18.0% (n = 22/122; 95% CI 12.1-25.9). Pleural effusions were the most common postoperative complications (n = 28/549; 5.1%; 95% CI 3.5-7.3). Reoperations were performed in 4.4% (n = 24/549; 95% CI 2.9-6.4) of the patients. All-cause mortality rate was 9.8% (n = 51/521; 95% CI 7.5-12.7). Genetic syndromes are seen in approximately 15% of ToF patients. Long-term survival exceeds 90%, suggesting that surgical management should be dictated by anatomy regardless of genetics.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Tetralogía de Fallot/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Síndrome de DiGeorge/epidemiología , Síndrome de Down/epidemiología , Femenino , Humanos , Incidencia , Lactante , Recién Nacido , Masculino , Válvula Pulmonar/cirugía , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Tetralogía de Fallot/epidemiología , Tetralogía de Fallot/etiología , Tetralogía de Fallot/genética , Resultado del Tratamiento
5.
Q J Nucl Med Mol Imaging ; 62(2): 200-208, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25319041

RESUMEN

BACKGROUND: We sought to evaluate the potential role of positron emission tomography-computed tomography (PET-CT) for the detection and diagnosis of potential infections of vascular grafts using combining metabolic (i.e., radioactive fluorine-fluoro-D-deoxyglucose [18F-FDG]) PET with morphological (CT) information and investigate long-term capability. METHODS: Seventeen patients with suspected vascular-graft infection underwent thoracic-abdominal-pelvic FDG PET combined with contrast-enhanced CT using a hybrid PET-CT scanner providing co-registered PET and CT images. RESULTS: In this retrospect study, we suspected graft infection in 14 of 17 patients detected using PET-CT and increased the maximal uptake of 18F-FDG around the grafts. Other vascular localizations were not observed. All patients with positive PET-CT results underwent redo-surgery, and the infection was ultimately confirmed using microbiological testing in 12 of 14 patients. Follow-up time was median of 58 months (range 36-73 months) for all 17 patients. In these patients, there was no further evidence of graft infection found on clinical and imaging follow-up. CONCLUSIONS: This is first investigation presenting long-term follow-up, which confirmed that 18F-FDG-PET/CT is an excellent diagnostic modality for suspected vascular graft infection. 18F-FDG PET-CT exhibited a sensitivity of 100% and specificity of 71.4% for the detection of vascular-graft infection.


Asunto(s)
Prótesis Vascular/microbiología , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Radiofármacos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
6.
Eur Surg Res ; 58(3-4): 169-179, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28297697

RESUMEN

BACKGROUND: Biodegradable atrioventricular annuloplasty rings are theoretically more infection resistant due to their intra-annular implantation technique and nonporous structures (monofilament of poly-1,4-dioxanone). The aim of this study was to investigate the infection resistance of a biodegradable annuloplasty ring (Kalangos-Bioring®) in a rat subcutaneous implantation model and to compare it with a commonly used conventional annuloplasty ring (Edwards Physio II®). METHODS: This study included 32 Wistar albino rats which were divided into 2 groups according to the implantation of sterile or infected annuloplasty rings as control and study groups. Each animal had 2 implantation pockets (made on the right and left side of the dorsal median line) where 1 cm of the biodegradable annuloplasty ring was implanted into one pocket and 1 cm of the conventional annuloplasty ring was implanted into the other pocket. The infection model was created by topical inoculation of 1 mL Staphylococcus aureus strain (2 × 107 colony-forming units/mL) into the implantation pockets before skin closure. Each group was equally divided into 4 subgroups according to different follow-up schedules. The animals were inspected for local as well as systemic infection signs, and the rings were explanted at weeks 2, 4, 9, and 14 following implantation. Implantation pockets were evaluated macroscopically as well as by histopathological examinations. Microbiological analysis of the explanted implants with surrounding tissue was done by using quantitative sonication method. RESULTS: Conventional ring-implanted pockets showed a more prominent inflammation reaction than the biodegradable ring-implanted pockets, and this characteristic was found to be accentuated with bacterial contamination. The sterile rings did not reveal any positive cultures in either group. The number of positive cultures found in conventional rings contaminated with S. aureus was greater than in the biodegradable ring group (11/16 vs. 2/16 positive cultures, respectively; p = 0.0032). The amounts of growing bacteria in the culture environment were also statistically significantly higher in the conventional ring group (7,175 ± 5,936 vs. 181 ± 130 colony-forming units/mL, respectively; p < 0.0005). CONCLUSIONS: This is the first experimental study confirming the theoretical advantage of the infection resistance of the biodegradable annuloplasty ring (Kalangos-Bioring®) when implanted in an active infectious environment. Large animal models mimicking clinical scenarios and clinical comparative studies are needed to verify our results.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/instrumentación , Prótesis Valvulares Cardíacas/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Animales , Anuloplastia de la Válvula Cardíaca/efectos adversos , Masculino , Ensayo de Materiales , Infecciones Relacionadas con Prótesis/etiología , Ratas Wistar , Staphylococcus aureus
7.
Ann Vasc Surg ; 33: 230.e15-8, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26968368

RESUMEN

BACKGROUND: To report the case of a rapidly growing aortic false aneurysm because of Q fever infection that was managed by embolization. CASE REPORT: An 80-year-old man was admitted to our unit for an aortic false aneurysm from a chronic Q fever infection. During his stay, the aneurysm showed rapid progression necessitating urgent treatment. The patient was unfit for surgical repair; moreover, the location of the aneurysm at the level of the superior mesenteric artery prohibited the use of an endovascular graft. He was managed by coiling of the aneurysmal cavity with multiple detachable coils after positioning of a bare aortic stent to lock the coils and prevent their migration into the aortic lumen. The false aneurysm was successfully thrombosed with no complications. The patient was then put on doxycycline and hydroxychloroquine to target Coxiella burnetii. CONCLUSIONS: Aortic false aneurysm coiling is feasible in cases where an endograft is not possible or an open repair is contraindicated. The use of a bare metal stent may help as a barrier to prevent the coils from migrating into the aneurysm and thus avoiding embolization into the systemic circulation.


Asunto(s)
Aneurisma Falso/terapia , Aneurisma Infectado/terapia , Aneurisma de la Aorta/terapia , Coxiella burnetii/aislamiento & purificación , Embolización Terapéutica , Fiebre Q/microbiología , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Aneurisma Infectado/diagnóstico por imagen , Angiografía de Substracción Digital , Antibacterianos/uso terapéutico , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía/métodos , Técnicas Bacteriológicas , Angiografía por Tomografía Computarizada , Doxiciclina/uso terapéutico , Quimioterapia Combinada , Humanos , Hidroxicloroquina/uso terapéutico , Masculino , Fiebre Q/diagnóstico , Resultado del Tratamiento
8.
Innovations (Phila) ; 11(1): 70-2, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26901750

RESUMEN

A 65-year-old patient underwent double coronary artery bypass grafting using the left internal thoracic artery on the left anterior descending coronary artery and nitinol alloy mesh [external Saphenous Vein Support (eSVS)]-covered saphenous vein graft to the right posterior descending coronary artery. Transit-time flow measurements (TTFMs) were obtained on meshed and bare parts of the vein graft. There was no difference in TTFM parameters (flow, pulsatility index, and diastolic fraction values) obtained from the eSVS mesh-covered and the uncovered parts of the venous graft. This observation confirms that eSVS mesh does not interfere with TTFM on venous coronary bypass conduits.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Puente de Arteria Coronaria/métodos , Vena Safena/trasplante , Mallas Quirúrgicas , Anciano , Circulación Coronaria/fisiología , Humanos , Monitoreo Intraoperatorio/métodos , Vena Safena/fisiología
9.
Surg Radiol Anat ; 38(3): 361-7, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26553051

RESUMEN

PURPOSE: Many regions worldwide report difficulties in recruiting applicants to surgery. One strategy proposed to reverse this trend consists of early exposure of medical students to the field. Against this backdrop, the present study presents an innovative approach for anatomy teaching, integrating a surgically relevant trend: 3D printing. METHODS: Whole-body computed tomography (CT) was made of two cadavers. Twelve students performed measurements and 3D reconstructions of selected anatomical structures (Osirix, Mimics). 3D printed (3DP) models were obtained (ZPrinter 310 Plus), and the students completed the analogous measurements on these replicas. Finally, classical anatomical dissection was performed and the same parameters were measured. The differences between the values obtained by the three modalities were submitted to standard statistical analysis (Wilcoxon two-tail paired test). RESULTS: Qualitative comparison of the digital 3D reconstructions based on the students' manual CT segmentation and the anatomical reality showed excellent correlation. Quantitatively, the values measured on the CT images and the physical models created by 3D printing differed from those measured on the cadavers by less than 2 mm. Students were highly appreciative of the approach (CT, 3DP, cadaver). Their average satisfaction score was 5.8 on a 1-6 scale. CONCLUSIONS: This study shows that the approach proposed can be achieved. The results obtained also show that CT-based 3D printed models are close to the authentic anatomic reality. The program allows early and interactive exposure of medical students to a surgically relevant trend-in this case 3D printing.


Asunto(s)
Anatomía/educación , Impresión Tridimensional , Adulto , Anciano , Disección , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Masculino , Proyectos Piloto , Tomografía Computarizada por Rayos X , Imagen de Cuerpo Entero
10.
Heart Surg Forum ; 18(3): E114-5, 2015 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-26115157

RESUMEN

INTRODUCTION: Anomalies of the aortic arch are frequent congenital malformations, which rarely form partial or complete vascular rings. A rare form of vascular ring is the encircling, or circumflex, aortic arch. CASE REPORT: A 19-month-old boy, with no respiratory symptoms, was referred for ventricular septal defect (VSD) repair. Cardiac magnetic resonance imaging and echocardiography confirmed the perimembranous VSD, a bicuspid aortic valve with normal function, and showed a right-sided ascending aorta, bifurcating to the left behind the esophagus and trachea above the tracheal bifurcation, with a left-sided descending aorta, a left ligamentum arteriosum and aberrant left subclavian artery, realizing a circumflex aortic arch. The child underwent successful VSD repair and ligamentum arteriosum division, with an uneventful postoperative course. CONCLUSIONS: Previous reports have described the association of circumflex aortic arch with VSD, but there is no previous report of its association with VSD and bicuspid aortic valve. Patients are usually symptomatic either preoperatively, or after VSD repair. For this reason, division of the ligamentum arteriosum, to open the vascular ring and free the trachea and esophagus from compression, should be performed in patients undergoing cardiac surgery for associated malformations.


Asunto(s)
Aorta Torácica/anomalías , Válvula Aórtica/anomalías , Defectos del Tabique Interventricular/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Aorta Torácica/cirugía , Válvula Aórtica/cirugía , Enfermedades Asintomáticas , Enfermedad de la Válvula Aórtica Bicúspide , Procedimientos Quirúrgicos Cardíacos , Defectos del Tabique Interventricular/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Lactante , Masculino
11.
Cardiol Young ; 25(2): 295-300, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24382023

RESUMEN

INTRODUCTION: Patients with absent pulmonary valve syndrome often present early with airway compression from aneurysmal pulmonary arteries. This study reviews our experience in managing absent pulmonary valve syndrome in later presenting children, and techniques used for managing airway compression. METHODS: This study is a retrospective chart review of all patients who underwent repair of absent pulmonary valve syndrome from 2000 to 2012 at our institution. The primary endpoints were post-operative bronchoscopic and clinical evidence of persistent airway compression and need for reinterventions on the pulmonary arteries. RESULTS: A total of 19 patients were included during the study period. The mean age at repair was 4.1±3.0 years (range 10 months-11 years). In all, seven patients had pre-operative bronchoscopic evidence of airway compression, which was managed by pulmonary artery reduction plasty in four patients and Lecompte manoeuvre in three patients. There were no peri-operative deaths. In patients with pulmonary artery plasty, two had no post-operative airway compression, one patient had improved compression, and one patient had unchanged compression. In patients managed with a Lecompte manoeuvre, two patients had no or trivial airway compression and one had improved compression. There were six late reinterventions or reoperations on the pulmonary arteries - two out of four in the pulmonary artery plasty group and one out of three in the Lecompte group. CONCLUSIONS: Most late-presenting patients with absent pulmonary valve syndrome do not have airway compression. Either pulmonary artery reduction plasty or the Lecompte manoeuvre can relieve proximal airway compression, without a significantly different risk of pulmonary artery reintervention between techniques.


Asunto(s)
Obstrucción de las Vías Aéreas/etiología , Aneurisma/cirugía , Bronquios , Defectos del Tabique Interventricular/cirugía , Enfermedades de las Válvulas Cardíacas/congénito , Arteria Pulmonar/cirugía , Válvula Pulmonar/anomalías , Tráquea , Aneurisma/complicaciones , Broncoscopía , Niño , Preescolar , Estudios de Cohortes , Femenino , Defectos del Tabique Interventricular/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Lactante , Masculino , Reoperación , Estudios Retrospectivos , Síndrome
12.
Int Wound J ; 12(5): 595-7, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24684727

RESUMEN

A 56-year-old patient who underwent ascending aorta replacement postoperatively developed mediastinitis with atypical Mycoplasma hominis. We present the first successful treatment of M. hominis mediastinitis after cardiac surgery with vacuum-assisted closure (VAC)-Instill(®) therapy combined with dilute antiseptic irrigation for bacterial eradication.


Asunto(s)
Mediastinitis/microbiología , Infecciones por Mycoplasma/terapia , Mycoplasma hominis , Terapia de Presión Negativa para Heridas , Esternotomía/efectos adversos , Infección de la Herida Quirúrgica/terapia , Enfermedades de la Aorta/cirugía , Humanos , Mediastinitis/terapia , Persona de Mediana Edad , Infecciones por Mycoplasma/etiología , Infección de la Herida Quirúrgica/microbiología
13.
BMC Surg ; 14: 48, 2014 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-25087015

RESUMEN

BACKGROUND: One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, "vanishing" material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. DISCUSSION: Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. SUMMARY: These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or initial clinical results, however long-term outcomes are lacking and further data is necessary to validate this theoretically interesting approach to infective endocarditis.


Asunto(s)
Implantes Absorbibles , Endocarditis/cirugía , Prótesis e Implantes , Técnicas de Sutura/instrumentación , Suturas , Humanos , Diseño de Prótesis
14.
Ann Thorac Surg ; 98(1): 314-6, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24996710

RESUMEN

Extraanatomical bypass has been advocated as the primary technique in adolescents or adults presenting with aortic coarctation. This approach carries significant morbidity, and graft-related complications may be more important in the young patient population. A 52-year-old man who had previously undergone extraanatomical bypass of aortic coarctation was diagnosed with a distal anastomotic pseudoaneurysm and aortoesophageal fistula. This was managed by proximal bypass plugging with an occluder, endovascular exclusion with a stent-graft in the thoracic descending aorta covering the pseudoaneurysm, and coarctation balloon dilation. Aortoesophageal fistula is a late complication observed after extraanatomical bypass for coarctation. This case illustrates this rare complication.


Asunto(s)
Aorta Torácica/cirugía , Coartación Aórtica/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/métodos , Fístula Esofágica/cirugía , Fístula Vascular/cirugía , Aorta Torácica/diagnóstico por imagen , Coartación Aórtica/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/cirugía , Aortografía , Fístula Esofágica/diagnóstico por imagen , Fístula Esofágica/etiología , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Tomografía Computarizada por Rayos X , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología
16.
Ann Thorac Surg ; 97(4): e97-9, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24694457

RESUMEN

Chylopericardium after intrathoracic surgical procedures rarely occurs. Optimal guidelines for the management of chylopericardium are lacking. In this case report, we describe our experience in treating chylopericadium with somatostatin in a 47-year-old man who underwent replacement of the ascending aorta and aortic valvuloplasty after aortic rupture. Postoperatively, a late tamponade was drained, and microbiologic analyses confirmed chyle. Conservative treatment including total parental nutrition failed, so we initiated somatostatin treatment as a continuous perfusion, with good results.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta Torácica/cirugía , Derrame Pericárdico/tratamiento farmacológico , Complicaciones Posoperatorias/tratamiento farmacológico , Somatostatina/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Inducción de Remisión
17.
World J Pediatr Congenit Heart Surg ; 5(1): 128-30, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24403372

RESUMEN

Little data are available in late-presenting children with unobstructed totally anomalous pulmonary venous connection. Eleven patients underwent repair at a median age of 6.5 months using a modified transseptal approach to improve access and avoid circulatory arrest. There were no early or late deaths, and none of the patients presented pulmonary venous stenosis at a median follow-up of 8.7 years.


Asunto(s)
Anomalías Múltiples/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Atrios Cardíacos/cirugía , Cardiopatías Congénitas/cirugía , Venas Pulmonares/anomalías , Venas Pulmonares/cirugía , Procedimientos Quirúrgicos Vasculares/métodos , Anomalías Múltiples/diagnóstico , Puente Cardiopulmonar/métodos , Niño , Preescolar , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico , Hospitales Universitarios , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
18.
Ann Vasc Surg ; 28(4): 1036.e1-3, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24216405

RESUMEN

We report the case of an acute ischemia of the superior mesenteric artery (SMA) after endovascular fenestration of a complicated acute type B aortic dissection. An initial attempt for endovascular revascularization of the SMA failed, and an ascending aorto-superior mesenteric artery bypass was urgently performed to salvage the small bowel. Surgery of patients in these specific settings is more complex because an adequate, more distal inflow vessel is often not present due to the dissected aorta and iliac arteries. This surgical option could be lifesaving and should be part of the vascular surgeon's armamentarium.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Arteria Mesentérica Superior/cirugía , Isquemia Mesentérica/cirugía , Oclusión Vascular Mesentérica/cirugía , Disección Aórtica/diagnóstico , Aorta/fisiopatología , Aneurisma de la Aorta/diagnóstico , Aortografía/métodos , Femenino , Humanos , Arteria Mesentérica Superior/fisiopatología , Isquemia Mesentérica/diagnóstico , Isquemia Mesentérica/etiología , Isquemia Mesentérica/fisiopatología , Oclusión Vascular Mesentérica/diagnóstico , Oclusión Vascular Mesentérica/etiología , Oclusión Vascular Mesentérica/fisiopatología , Persona de Mediana Edad , Reoperación , Circulación Esplácnica , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
Kardiochir Torakochirurgia Pol ; 11(3): 311-20, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26336441

RESUMEN

AIM: To assess the safety and feasibility of use of a novel high vacuum chest drainage system (HVCDS) and its influence on the cardiovascular system compared to a conventional system (CCDS). MATERIAL AND METHODS: Five anesthetized pigs underwent a median sternotomy. Three drains were placed in retrocardiac, retrosternal and left pleural positions. The animals received a HVCDS (22 Fr with 180 2-mm holes, n = 2) or a CCDS (n = 2). In the fifth animal off pump coronary artery bypass graft (OPCABG) stabilizers were tested. After chest closure animals had three 30 min runs of artificial bleeding (5 ml/min) under different negative aspiration pressures (-2, -20, -40 kPa) for both groups, followed by standardized surgical bleeding (-40 kPa - HVCDS, - 2 kPa - CCDS). Hemodynamic parameters and each drain's output were registered every 5 minutes and the residual blood was assessed. All catheters, the heart and left lung underwent macroscopic and histopathological examination. RESULTS: The application of the different pressures showed neither hemodynamic changes nor differences in blood drainage with both systems in two bleeding models. The HVCDS enabled drainage comparable to the CCDS but showed relevant clotting. Application of -20 kPa and -40 kPa caused macroscopic epicardial and pulmonary lesions in all tested devices including OPCABG stabilizers consisting of sub-epicardial or sub-pleural hemorrhage without myocyte or alveolar damage. CONCLUSIONS: The novel and conventional chest drainage systems used at pressures up to 40 kPa induced no hemodynamic instability. Both systems showed adequate equal drainage, despite major HVCDS clotting. High negative pressure drainage with both systems showed focal sub-epicardial and subpleural hemorrhage. Thus, long-term assessment of high pressure drainage and potential interaction with fragile structures (coronary bypass graft) should be carried out.

20.
World J Pediatr Congenit Heart Surg ; 4(4): 385-91, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24327632

RESUMEN

Surgical management of aortic insufficiency in the young is problematic because of the lack of an ideal valve substitute. Potential advantages of aortic valve repair include low incidences of thromboembolism and endocarditis, avoiding conduit replacements, the maintenance of growth potential, and improved quality of life. Aortic valve repair is still far from fulfilling the three key factors that have allowed the phenomenal development of mitral valve repair (standardization, reproducibility, and stable long-term results); however, techniques of aortic valve repair have been refined, and subsets of patients amenable to repair have been identified. We have focused on the oldest technique of aortic valve repair, cusp extension, focusing on children with rheumatic aortic insufficiency. Among 77 children operated from 2003 to 2007, there was one early death from ventricular failure and one late death from sudden cardiac arrhythmia. During a mean follow-up of 12.8 ± 5.9 years, there were 16 (20.5%) reoperations on the aortic valve, at a median of 3.4 years (range, 2 months to 18.3 years) from repair. Freedom from aortic valve reoperation was 96.2% ± 2.2% at 1 year, 94.9% ± 2.5% at 2 years, 88.5% ± 3.6% at 5 years, 81.7% ± 4.4% at 10 years, 79.7% ± 4.8% at 15 years, and 76.2% ± 5.7% at 20 years. Although aortic cusp extension is technically more demanding, it remains particularly more suitable in the context of evolving rheumatic aortic insufficiency in children with a small aortic annulus as a bridge surgical approach to late aortic valve replacement with a larger valvular prosthesis.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Cardiopatía Reumática/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Niño , Humanos , Cardiopatía Reumática/complicaciones , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA