Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Sci Rep ; 13(1): 19322, 2023 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-37935729

RESUMEN

The immune response in patients with Coronavirus Disease 2019 (COVID-19) is highly variable and is linked to disease severity and mortality. However, antibody and cytokine responses in the early disease stage and their association with disease course and outcome are still not completely understood. In this large, multi-centre cohort study, blood samples of 434 Belgian COVID-19 hospitalized patients with different disease severities (ranging from asymptomatic/mild to critically ill) from the first wave of the COVID-19 pandemic were obtained. Baseline antibody and cytokine responses were characterized and associations with several clinical outcome parameters were determined. Anti-spike immunoglobulin (Ig)G and IgM levels were elevated in patients with a more severe disease course. This increased baseline antibody response however was associated with decreased odds for hospital mortality. Levels of the pro-inflammatory cytokines IL-6, IP-10 and IL-8, the anti-inflammatory cytokine IL-10 and the antiviral cytokines IFN-α, IFN-ß and IFN-λ1 were increased with disease severity. Remarkably, we found significantly lower levels of IFN-λ2,3 in critically ill patients compared to patients of the moderate and severe disease category. Finally, levels of IL-8, IL-6, IP-10, IL-10, IFN-α, IFN-ß, IFN-γ and IFN-λ1 at baseline were positively associated with mortality, whereas higher IFN-λ2,3 levels were negatively associated with mortality.


Asunto(s)
COVID-19 , Humanos , Interleucina-10 , Interleucina-6 , Quimiocina CXCL10 , Interleucina-8 , Pandemias , Enfermedad Crítica , Bélgica/epidemiología , Estudios de Cohortes , Citocinas , Interferón-alfa , Inmunoglobulina G
2.
Acta Clin Belg ; 71(6): 458-461, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27368113

RESUMEN

OBJECTIVE AND IMPORTANCE: Suspected hemoglobin (Hb) variants, detected during HbA1C measurements should be further investigated, determining the extent of the interference with each method. CLINICAL PRESENTATION: This is the first report of Hb Melusine and Hb Athens-Georgia in Caucasian Belgian patients. Intervention & Technique: Since common CE-HPLC methods for HbA1C analysis or Hb variant screening are apparently unable to detect these Hb variants, their presence might be underestimated. HbA1C analysis using CZE, however, alerted for their presence. Moreover, in case of Hb Melusine, even Hb variant screening using CZE was unsuccessful in its detection. CONCLUSION: Fortunately, carriage of Hb Melusine or Hb Athens-Georgia variants has no clinical implications and, as shown in this report, no apparent difference in HbA1C should be expected.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Diabetes Mellitus/sangre , Hemoglobina Glucada/análisis , Hemoglobinas Anormales/análisis , Tamizaje Masivo/métodos , Anciano , Bélgica/epidemiología , Diabetes Mellitus/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia
3.
Acta Clin Belg ; 71(3): 167-70, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27098765

RESUMEN

INTRODUCTION: We present a case of an arterial blood gas sample analysis from a 33-year old woman where no oximetry results could be obtained using the Radiometer ABL800 FLEX device. Clinical history of this patient learned that she was carrier of a methemoglobin forming hemoglobin variant type Hyde Park (HbM Hyde Park) and raised the question whether or not this variant could be the cause of the errors obtained during analysis. MATERIALS AND METHODS: A literature search was performed, focusing on methemoglobin forming hemoglobin variants and their influence on oxygenation measurements. An overview of the currently described methemoglobin forming hemoglobin variants is also included. RESULTS AND DISCUSSION: In the presence of dyshemoglobins such as methemoglobin, techniques used to obtain parameters that reflect the patient oxygenation status, such as pulse oximetry and CO-oximetry can be influenced. In these cases, CO-oximetry is the preferred technique because it can compensate for this, in contrast to pulse oximetry. In case of the presence of methemoglobin originating from a hemoglobin variant, it is possible that CO-oximetry data cannot be calculated because the absorbance spectrum of this methemoglobin can differ from regular methemoglobin. Moreover, pulse oximetry devices are actually prone to erroneous results since pulse oximetry data will be calculated in these cases, but unreliable and should be avoided. CONCLUSION: Methemoglobin forming hemoglobin variants are rare genetic mutations. However, they can possibly interfere with the calculation of CO-oximetry values. In these cases, pulse oximetry data should be avoided because they could lead to incorrect medical decisions.


Asunto(s)
Análisis de los Gases de la Sangre , Hemoglobina M , Hemoglobinas , Metahemoglobina , Adulto , Errores Diagnósticos , Análisis de Falla de Equipo , Femenino , Hemoglobina M/análisis , Hemoglobina M/química , Hemoglobinas/análisis , Hemoglobinas/química , Humanos , Metahemoglobina/análisis , Metahemoglobina/química , Mutación , Oximetría
4.
J Pharm Biomed Anal ; 32(4-5): 669-78, 2003 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-12899957

RESUMEN

Due to the low concentrations in which 99mTc-radiopharmaceuticals are obtained (4-40 ng/ml), confirmation of the identity of these tracer agents in the European Pharmacopoeia is generally performed only indirectly by assessment of their retention times on RP-HPLC. We have investigated whether it is possible to obtain more direct proof of the identity of technetium-99m labelled radiopharmaceuticals using radio-LC-MS. As representative examples, negatively charged 99mTc-MAG3, positively charged 99mTc-Sestamibi and neutral 99mTc-ECD were used. The three technetium-99m radiopharmaceuticals were prepared in several conditions to obtain variable relative amounts of radiochemical impurities and variable concentrations of the complexes (pico- to nanomolar). The preparations were analyzed on a reversed phase C18 HPLC column using a radio-LC-MS system equipped with a time of flight mass spectrometer with electrospray ionization in positive (99mTc-Sestamibi, 99mTc-ECD) or negative (99mTc-MAG3, 99mTc-ECD) mode. For each of the studied complexes, the main peak in the radiometric channel coincided with the expected molecular ion mass of the corresponding technetium complex in the mass spectrometer channel. The relative error on the measured accurate mass was in the range of 10 ppm. The identity of several radiochemical impurities of the three technetium complexes was also confirmed or established. It is concluded that radio-LC-MS can be a sensitive aid in quality control of 'no carrier added' radiopharmaceuticals.


Asunto(s)
Cisteína/análogos & derivados , Cisteína/análisis , Compuestos de Organotecnecio/análisis , Tecnecio Tc 99m Mertiatida/análisis , Tecnecio Tc 99m Sestamibi/análisis , Tecnología Farmacéutica/métodos , Cromatografía Liquida/métodos , Cisteína/química , Espectrometría de Masas/métodos , Compuestos de Organotecnecio/química , Tecnecio Tc 99m Mertiatida/química , Tecnecio Tc 99m Sestamibi/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA