Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Hip Int ; 27(1): 26-34, 2017 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-27515762

RESUMEN

INTRODUCTION: Periprosthetic bone loss may lead to major complications in total hip arthroplasty (THA), including loosening, migration, and even fracture. This study analysed the influence of femoral implant designs on periprosthetic bone mineral density (BMD) after THA. METHODS: The results of all previous published studies reporting periprosthetic femoral BMD following THA were compiled. Using these results, we compared percent changes in bone loss as a function of: femoral stem fixation, material, and geometry. RESULTS: The greatest bone loss was in the calcar region (Gruen Zone 7). Overall, cemented stems had more bone loss distally than noncemented stems, while noncemented stems had more proximal bone loss than cemented stems. Within noncemented stems, cobalt-chromium (CoCr) stems had nearly double the proximal bone loss compared to titanium (Ti) alloy stems. Finally, within noncemented titanium alloy group, straight stems had less bone loss than anatomical, tapered, and press-fit designs. DISCUSSION: The findings from the present study quantified percent changes in periprosthetic BMD as a function of fixation method, alloy, and stem design. While no one stem type was identified as ideal, we now have a clearer understanding of the influence of stem design on load transfer to the surrounding bone.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Densidad Ósea/fisiología , Prótesis de Cadera , Osteoporosis/cirugía , Falla de Prótesis , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/cirugía , Osteoporosis/diagnóstico por imagen , Fracturas Periprotésicas/diagnóstico por imagen , Fracturas Periprotésicas/cirugía , Pronóstico , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento
2.
Foot Ankle Surg ; 22(4): 278-285, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27810029

RESUMEN

BACKGROUND: The goal of this study was to evaluate the biomechanical performance of three distal fibula fracture fixation implants in a matched pair cadaveric fibula model: (1) a 5-hole compression plate with lag screw, (2) a 5-hole locking plate with lag screw, and (3) the 6-hole tabbed-plate with locking screws. METHODS: Three-dimensional motions between the proximal and distal fibular segments were measured under cyclic valgus bending, cyclic compressive axial loading, and cyclic torsional external-rotation loading. During loading, strains were measured on the surfaces of each fibula near the simulated fracture site, and on the plate, to assess load transfer. Bone quality was quantified globally for each donor using bone mineral density (BMD) measured using Dual X-ray absorptiometry (DEXA) and locally at the fracture site using bone mineral content (BMC) measured using peripheral quantitative computed tomography (pQCT). RESULTS: Mean failure loads were below 0.2Nm of valgus bending and below 4Nm of external-rotational torque. Mean failure angulation was below 1degree for valgus bending, and failure rotation was below 7degrees for external-rotation. In the compression plate group, significant correlations were observed between bone quality (global BMD and local BMC) and strain in every one of the five locations (Pearson correlation coefficients >0.95, p<0.05). In contrast, in the locking and tabbed-plate groups, BMD and BMC correlated with far fewer strain locations. CONCLUSIONS: Overall, the tabbed-plate had similar construct stability and strength to the compression and locking plates. However, the distribution of load with the locking and tabbed-plates was not as heavily dependent on bone quality.


Asunto(s)
Placas Óseas , Peroné/lesiones , Peroné/cirugía , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Fracturas Intraarticulares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas/métodos , Humanos , Fijadores Internos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Estrés Mecánico , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA