Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38545321

RESUMEN

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

2.
J Cardiovasc Electrophysiol ; 35(5): 916-928, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38439119

RESUMEN

INTRODUCTION: Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12-lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case-control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy. MATERIALS AND METHODS: Cases in which system output was used were retrospectively enrolled according to IRB-approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time-stamped medical records. RESULTS: The study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation (n = 10), premature ventricular complexes (n = 8), and ventricular tachycardia (n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow-up, arrhythmia-free survival was 73.5% in the study group and 63.3% in the control group (p = 0.56). CONCLUSION: Use of forward-solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.


Asunto(s)
Potenciales de Acción , Arritmias Cardíacas , Inteligencia Artificial , Ablación por Catéter , Valor Predictivo de las Pruebas , Tiempo de Tratamiento , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Fluoroscopía , Frecuencia Cardíaca , Tempo Operativo , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estudios de Casos y Controles
3.
JACC Case Rep ; 15: 101870, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37283824

RESUMEN

In patients presenting with refractory ventricular tachycardia (VT) and aortic and mitral mechanical prosthetic valves, traditional catheter ablation is challenging. We describe a case in which a novel noninvasive computational electrocardiogram mapping algorithm localized VT sources originating from substrate near the mechanical valves, in which stereotactic ablative radiotherapy eliminated VT in 1.5-year follow-up. (Level of Difficulty: Advanced.).

4.
J Interv Card Electrophysiol ; 64(3): 715-722, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35169965

RESUMEN

BACKGROUND: The mechanisms for atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) catheter ablation are unclear. Non-PV organized atrial arrhythmias (PAC, AT, macro-reentrant AFL) are possible contributors; however the prevalence and effect of their ablation on recurrent AF are unknown. We hypothesize that the identification and ablation of non-PV organized atrial arrhythmias were associated with less AF recurrence. METHODS: Patients who underwent repeat ablation for recurrent AF after prior PVI were retrospectively enrolled. The prevalence and characteristics of PV reconnections and non-PV organized atrial arrhythmias were identified. The outcomes of time to clinical AF recurrence, heart failure (HF) hospitalization, and mortality were analyzed in patients using multivariable adjusted Cox regression. RESULTS: In 74 patients with recurrent AF (age 66 ± 9 years, left atrial volume index 38 ± 10 ml/m2, 59% persistent AF), PV reconnections were found in 46 patients (61%), macro-reentrant atrial flutter in 27 patients (36%), and focal tachycardia in 12 patients (16%). Mapping and ablation of non-PV organized atrial arrhythmias were associated with a reduced recurrence of late clinical AF (adjusted HR 0.26, CI 0.08-0.85, p = 0.03) and the composite outcome of recurrence of late AF, HF hospitalization, and mortality (adjusted HR 0.38, CI 0.17-0.85, p = 0.02), with median follow-up of 1.6 (IQR 0.7-6.3) years. The presence of PV reconnections or empiric linear ablation was not associated with reduction in clinical AF or composite endpoints. CONCLUSION: The ablation of non-PV organized atrial arrhythmias resulted in a reduction of late clinical AF recurrence and composite outcome. In this challenging population, alternate mechanisms beyond PV reconnections need to be considered. Prospective studies are needed.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/epidemiología , Ablación por Catéter/métodos , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
5.
Heart Rhythm O2 ; 2(5): 511-520, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34667967

RESUMEN

BACKGROUND: Stereotactic ablative radiotherapy (SAbR) is an emerging therapy for refractory ventricular tachycardia (VT). However, the current workflow is complicated, and the precision and safety in patients with significant cardiorespiratory motion and VT targets near the stomach may be suboptimal. OBJECTIVE: We hypothesized that automated 12-lead electrocardiogram (ECG) mapping and respiratory-gated therapy may improve the ease and precision of SAbR planning and facilitate safe radiation delivery in patients with refractory VT. METHODS: Consecutive patients with refractory VT were studied at 2 hospitals. VT exit sites were localized using a 3-D computational ECG algorithm noninvasively and compared to available prior invasive mapping. Radiotherapy (25 Gy) was delivered at end-expiration when cardiac respiratory motion was ≥0.6 cm or targets were ≤2 cm from the stomach. RESULTS: In 6 patients (ejection fraction 29% ± 13%), 4.2 ± 2.3 VT morphologies per patient were mapped. Overall, 7 out of 7 computational ECG mappings (100%) colocalized to the identical cardiac segment when prior invasive electrophysiology study was available. Respiratory gating was associated with smaller planning target volumes compared to nongated volumes (71 ± 7 vs 153 ± 35 cc, P < .01). In 2 patients with inferior wall VT targets close to the stomach (6 mm proximity) or significant respiratory motion (22 mm excursion), no GI complications were observed at 9- and 12-month follow-up. Implantable cardioverter-defibrillator shocks decreased from 23 ± 12 shocks/patient to 0.67 ± 1.0 (P < .001) post-SAbR at 6.0 ± 4.9 months follow-up. CONCLUSIONS: A workflow including computational ECG mapping and protocol-guided respiratory gating is feasible, is safe, and may improve the ease of SAbR planning. Studies to validate this workflow in larger populations are required.

6.
JACC Clin Electrophysiol ; 3(4): 393-402, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28596994

RESUMEN

INTRODUCTION: The role of atrial fibrillation (AF) substrates is unclear in patients with paroxysmal AF (PAF) that recurs after pulmonary vein isolation (PVI). We hypothesized that patients with recurrent post-ablation (redo) PAF despite PVI have electrical substrates marked by rotors and focal sources, and structural substrates that resemble persistent AF more than patients with (de novo) PAF at first ablation. METHODS: In 175 patients at 11 centers, we compared AF substrates in both atria using 64 pole-basket catheters and phase mapping, and indices of anatomical remodeling between patients with de novo or redo PAF and first ablation for persistent AF. RESULTS: Sources were seen in all patients. More patients with de novo PAF (78.0%) had sources near PVs than patients with redo PAF (47.4%, p=0.005) or persistent AF (46.9%, p=0.001). The total number of sources per patient (p=0.444), and number of non-PV sources (p=0.701) were similar between groups, indicating that redo PAF patients had residual non-PV sources after elimination of PV sources by prior PVI. Structurally, left atrial size did not separate de novo from redo PAF (49.5±9.5 vs. 49.0±7.1mm, p=0.956) but was larger in patients with persistent AF (55.2±8.4mm, p=0.001). CONCLUSIONS: Patients with paroxysmal AF despite prior PVI show electrical substrates that resemble persistent AF more closely than patients with paroxysmal AF at first ablation. Notably, these subgroups of paroxysmal AF are indistinguishable by structural indices. These data motivate studies of trigger versus substrate mechanisms for patients with recurrent paroxysmal AF after PVI.


Asunto(s)
Fibrilación Atrial/patología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Humanos , Recurrencia , Reoperación , Resultado del Tratamiento
7.
Europace ; 19(5): 769-774, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339546

RESUMEN

AIMS: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). METHODS AND RESULTS: We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). CONCLUSIONS: Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation.


Asunto(s)
Fibrilación Atrial/mortalidad , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/mortalidad , Ablación por Catéter/mortalidad , Ablación por Catéter/estadística & datos numéricos , Complicaciones Posoperatorias/mortalidad , Cirugía Asistida por Computador/mortalidad , Fibrilación Atrial/diagnóstico por imagen , Mapeo del Potencial de Superficie Corporal/métodos , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Ablación por Catéter/métodos , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Prevalencia , Factores de Riesgo , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/estadística & datos numéricos , Tasa de Supervivencia , Resultado del Tratamiento , Estados Unidos/epidemiología
8.
Pacing Clin Electrophysiol ; 39(11): 1254-1260, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27550834

RESUMEN

BACKGROUND: Radiofrequency (RF) technology has improved detection of retained surgical sponges with a reported 100% sensitivity and specificity. However, the potential for interactions of the RF signals emitted by the detection system with cardiac implantable electronic devices (CIEDs) or temporary pacemakers may limit its use in those patients with these devices. This study investigated whether RF detection technology causes interference or clinically significant changes in the programmed settings of implanted pacemakers and defibrillators or temporary epicardial pacemakers. METHODS: Fifty patients who were scheduled either for CIED removal or placement of a temporary epicardial pacemaker (at the time of open heart surgery) were recruited for this study. Device settings and measurements from separate interrogations before and after scanning with the RF detection system were compared. For the temporary pacemakers, we observed for any changes in hemodynamics or signs of pacing interference. RESULTS: Twenty (40%) pacemakers, 20 (40%) implantable cardioverter defibrillators, and 10 (20%) temporary pacemakers were analyzed in this study. During scanning, no signal interference was detected in any permanent device, and there were no significant changes in programmed settings after scanning with the RF detection system. However, pacing inhibition was detected with temporary pacing systems when programmed to a synchronous mode (DDD). CONCLUSIONS: RF detection technology can be safely used to scan for retained surgical sponges in patients with permanent CIEDs and temporary pacemakers set to asynchronous mode.


Asunto(s)
Desfibriladores Implantables , Cuerpos Extraños/diagnóstico , Marcapaso Artificial , Ondas de Radio , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
9.
J Cardiovasc Electrophysiol ; 26(10): 1117-26, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26179310

RESUMEN

INTRODUCTION: Recent work has suggested a role for organized sources in sustaining ventricular fibrillation (VF). We assessed whether ablation of rotor substrate could modulate VF inducibility in canines, and used this proof-of-concept as a foundation to suppress antiarrhythmic drug-refractory clinical VF in a patient with structural heart disease. METHODS AND RESULTS: In 9 dogs, we introduced 64-electrode basket catheters into one or both ventricles, used rapid pacing at a recorded induction threshold to initiate VF, and then defibrillated after 18±8 seconds. Endocardial rotor sites were identified from basket recordings using phase mapping, and ablation was performed at nonrotor (sham) locations (7 ± 2 minutes) and then at rotor sites (8 ± 2 minutes, P = 0.10 vs. sham); the induction threshold was remeasured after each. Sham ablation did not alter canine VF induction threshold (preablation 150 ± 16 milliseconds, postablation 144 ± 16 milliseconds, P = 0.54). However, rotor site ablation rendered VF noninducible in 6/9 animals (P = 0.041), and increased VF induction threshold in the remaining 3. Clinical proof-of-concept was performed in a patient with repetitive ICD shocks due to VF refractory to antiarrhythmic drugs. Following biventricular basket insertion, VF was induced and then defibrillated. Mapping identified 4 rotors localized at borderzone tissue, and rotor site ablation (6.3 ± 1.5 minutes/site) rendered VF noninducible. The VF burden fell from 7 ICD shocks in 8 months preablation to zero ICD therapies at 1 year, without antiarrhythmic medications. CONCLUSIONS: Targeted rotor substrate ablation suppressed VF in an experimental model and a patient with refractory VF. Further studies are warranted on the efficacy of VF source modulation.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Sistema de Conducción Cardíaco/cirugía , Cirugía Asistida por Computador/métodos , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/cirugía , Animales , Perros , Estudios de Factibilidad , Proyectos Piloto , Resultado del Tratamiento
10.
Circ Arrhythm Electrophysiol ; 5(6): 1149-59, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23027797

RESUMEN

BACKGROUND: Mechanisms of atrial fibrillation (AF) initiation are incompletely understood. We hypothesized that rate-dependent changes (restitution) in action potential duration (APD) and activation latency are central targets for clinical interventions that induce AF. We tested this hypothesis using clinical experiments and computer models. METHODS AND RESULTS: In 50 patients (20 persistent, 23 paroxysmal AF, 7 controls), we used monophasic action potential catheters to define left atrial APD restitution, activation latency, and AF incidence from premature extrastimuli. Isoproterenol (n=14), adenosine (n=10), or rapid pacing (n=36) was then initiated to determine impact on these parameters. Compared with baseline in AF patients, isoproterenol and rapid pacing decreased activation latency (64±14 versus 31±13 versus 24±14 ms; P<0.05), steepened maximum APD restitution slope (0.8±0.7 versus 1.7±0.5 versus 1.1±0.5; P<0.05), and increased AF incidence (12% versus 64% versus 84%; P<0.05). Conversely, adenosine shortened APD (P<0.05), yet increased activation latency (86±27 ms; P=0.002) so that maximum APD restitution slope did not steepen (1.0±0.5; P=NS), and AF incidence was unchanged (10%; P=NS). In controls, no intervention steepened APD restitution or initiated AF. Computational modeling revealed that isoproterenol steepened APD restitution by increased L-type calcium current and decreased activation latency via enhanced rapid delayed potassium reactifier current inactivation, whereas rapid pacing steepened APD restitution via increased cardiac inward potassium rectifier current. CONCLUSIONS: Steep APD restitution is a common pathway for AF initiation by isoproterenol and tachycardia via reduced activation latency that enables engagement of steep APD restitution at rapid rates. Modeling suggests that AF initiation from each intervention uses distinct ionic mechanisms. This insight may help design interventions to prevent AF.


Asunto(s)
Potenciales de Acción/fisiología , Fibrilación Atrial/fisiopatología , Simulación por Computador , Sistema de Conducción Cardíaco/fisiopatología , Tiempo de Reacción/fisiología , Adenosina/farmacología , Agonistas Adrenérgicos beta/farmacología , Adulto , Anciano , Antiarrítmicos/farmacología , Canales de Calcio Tipo L/fisiología , Femenino , Humanos , Isoproterenol/farmacología , Masculino , Persona de Mediana Edad , Canales de Potasio de Rectificación Interna/fisiología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA