Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
PLoS One ; 17(11): e0277530, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36395120

RESUMEN

Adhesions formation after surgery for congenital heart defects can complicate follow-up procedures due to bleeding from detached adhesion bands, injury to cardiac structures or large vessels, all of which do prolong operation times. The problem is enhanced by the fact that detached adhesions are predilection sites for new adhesions setting off a downward spiral. 4DryField® PH gel barrier has demonstrated high efficacy in reducing postoperative adhesions in general surgical and gynecological studies. This retrospective controlled study of 22 patients evaluates whether these positive results can be confirmed in pediatric cardiac surgery. Adhesions were scored from photographs of follow-up interventions by an independent cardiac surgeon blinded to group assignment. The publication provides not only score numbers but also original photographs of all sites for better traceability and transparency. In addition, timesaving due to reduced adhesions was evaluated. Results show a significantly reduced adhesion score for the 4DryField® group. Importantly, this resulted in a significantly shorter period between skin incision and start of cardiopulmonary bypass. In addition, timesaving due reduced adhesion formation was evaluated. The use of 4DryField® was safe, although higher doses per kg were used than in adults.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Enfermedades Peritoneales , Procedimientos de Cirugía Plástica , Adulto , Humanos , Niño , Estudios Retrospectivos , Adherencias Tisulares/prevención & control , Adherencias Tisulares/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos
2.
Eur J Cardiothorac Surg ; 32(1): 102-7, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17419068

RESUMEN

OBJECTIVE: Orientation-related monoleaflet mechanical valve flow and velocity studies in the downstream are limited in mitral valve replacement studies. METHODS: In five sheep, ventricular blood flow was visualized prior to the implantation of a Medtronic Hall tilting valve model. In six sheep, the implant orientation was either anatomical (disc aligned with the anterior leaflet) or anti-anatomical. The mitral subvalvular apparatus was preserved. Sheep were positioned within an 1.5 T field strength MR scanner (Magnetom Sonata; Siemens) to assess time-dependent three dimensional blood flow. RESULTS: The preoperative ventricular velocity profiles presented negligible individual variances. Streamlines passed homogeneously without any spatial differences in flow velocities into the left ventricle. Starting from the anatomical position, blood entered mainly through the major orifice of the mechanical valve. The single artificial leaflet mimicked the rudder effect of the natural anterior mitral leaflet, preventing blood streaming directly towards the septum. The area with inhomogeneous blood velocities in the ventricle increased but not significantly from the preoperative status. The non-axial inflow not directed directly to the apex converted to a similar helix as observed in the preoperative cases. Anti-anatomical orientation of the prosthesis caused a significant increase in turbulence immediately after passing the mitral prosthesis. The main stream was changed so significantly that the blood flow shifted towards the septum and caused higher velocities of the stream profiles and turbulence apically. CONCLUSIONS: To achieve optimal hemodynamics, orientation of the mitral tilting valve has to be considered carefully, as has been long known from aortic valve replacement studies.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Función Ventricular Izquierda , Animales , Velocidad del Flujo Sanguíneo , Hemorreología , Imagen por Resonancia Magnética/métodos , Válvula Mitral/anatomía & histología , Válvula Mitral/fisiología , Ovinos
3.
Eur J Cardiothorac Surg ; 31(6): 1070-5; discussion 1075, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17337198

RESUMEN

OBJECTIVE: In an effort to minimize the effect of extracorporeal circulation (ECC), mini-bypass is gaining clinical acceptance in routine coronary artery bypass grafting (CABG). These small circuits target combine the clinical advantages of reduced prime, 100% bio-coating and suction blood separation. We demonstrate that the use of mini-bypass in routine CABG reduces homologous blood product use and postoperative bleeding. Our goal was to also demonstrate that these small systems are effective in gaseous microemboli (GME) management as compared to a conventional extracorporeal system. METHODS: Prospective, randomized study comparing 30 mini-bypass (Dideco ECC.O) to 30 conventional systems (n=30, Dideco 903 Avant). Study included CABG cases only, independent of preoperative coagulative status; clinic ethical committee approval and informed patient consent was obtained before initiating study. RESULTS: There were no statistical differences in terms of patient demographics. Statistically significant differences were seen in transfusion frequency (27% of the study group vs 43% in the control group, p=0.05), transfused volume (133.3+/-244.5 ml vs 325+/-483.1 ml, p<0.05), fresh frozen plasma (0 unit vs 3 units, p<0.001), postoperative bleeding (301.8+/-531.9 ml vs 785.5+/-1000.4 ml, p<0.05) and GME activity post-arterial filter (0.14 microl vs 5.32 microl, p<0.05). CONCLUSIONS: The adoption of mini-bypass significantly potentially reduces hemodilution, donor blood usage, postoperative bleeding and exposure to GME in routine CABG patients as compared to the use of conventional extracorporeal circulation circuits.


Asunto(s)
Pérdida de Sangre Quirúrgica/prevención & control , Transfusión de Sangre Autóloga , Puente de Arteria Coronaria/instrumentación , Embolia/prevención & control , Anciano , Puente Cardiopulmonar/instrumentación , Puente Cardiopulmonar/métodos , Puente de Arteria Coronaria/métodos , Cuidados Críticos/métodos , Embolia Aérea/prevención & control , Femenino , Humanos , Masculino , Persona de Mediana Edad , Plasma , Estudios Prospectivos , Tromboembolia/prevención & control
4.
Perfusion ; 20(3): 151-6, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-16038387

RESUMEN

Neurological complications remain an important cause of morbidity and mortality of patients following cardiopulmonary bypass (CPB). Microemboli, as well as cerebral hypoperfusion, are the main postulated mechanisms. This study demonstrates that the insertion of a dynamic bubble trap (DBT) into the curcuit reduces microbubbles in the arterial line and microembolic signals (MES) in the middle cerebral arteries (MCAs). We investigated 12 patients during coronary artery bypass grafting (CABG). The DBT was inserted between the arterial filter and the arterial cannula. For detection of microemboli before and after the DBT, a special ultrasound Doppler device was used. MES were detected by transcranial Doppler monitoring in both MCAs of the patients. Microbubbles and MES were counted during bypass. These data were compared to 12 patients who were operated in a previous period without the use of a DBT. There were no significant differences in both groups with respect to gender, age, crossclamp and bypass time and number of anastomoses. In the group without a DBT in the circuit, a mean of 6311 microbubbles per operation could be observed distal to the arterial filter, corresponding to 282 MES. After inclusion of a DBT, we could register, in the second group, 8496 microemboli proximal and 2915 distal of the DBT, corresponding to 89 MES per operation. The reduction rate of microbubbles in the tubing was 65.7%, corresponding to a reduction in MES of about 86.2%. We conclude that the insertion of a DBT in the arterial line of CPB circuit protects the cerebrovascular system from microembolic events, as demonstrated by lower MES counts.


Asunto(s)
Puente Cardiopulmonar/instrumentación , Embolia Aérea/diagnóstico , Microburbujas , Arteria Cerebral Media/diagnóstico por imagen , Monitoreo Intraoperatorio/métodos , Anciano , Puente Cardiopulmonar/efectos adversos , Puente Cardiopulmonar/métodos , Puente de Arteria Coronaria/instrumentación , Embolia Aérea/etiología , Embolia Aérea/prevención & control , Femenino , Filtración/instrumentación , Humanos , Masculino , Microburbujas/efectos adversos , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Ultrasonografía Doppler Transcraneal
5.
Perfusion ; 18(5): 325-9, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-14604252

RESUMEN

Microemboli during extracorporeal circulation (ECC) might be a reason for postoperative neuropsychological dysfunction. This case report shows that reduction of microbubbles in the arterial line, as well as high intensity transient signals (HITS) in the middle cerebral artery (MCA), could be accomplished by use of a dynamic bubble trap (DBT) during routine coronary artery bypass graft (CABG) surgery in a 63-year-old male. The DBT was placed after the arterial filter, an ultrasound Doppler device was used for detection of microemboli before and after the DBT. HITS were measured by a transcranial ultrasound Doppler in both MCAs. For first 32 min of ECC, the DBTwas excluded; 54 916 microbubbles and 507 HITS were counted. In the next 30 min, blood flow was directed through the DBT. This led to a significant reduction of microbubbles from 55 888 to 18 237; accordingly, only 120 HITS were registered. A DBT, integrated in ECC for routine CABG, effectively reduces air bubbles, thus protecting the cerebrovascular system from microembolization, as demonstrated by lower HITS counts.


Asunto(s)
Embolia Aérea/prevención & control , Circulación Extracorporea/efectos adversos , Arteria Cerebral Media/fisiopatología , Circulación Cerebrovascular , Puente de Arteria Coronaria , Embolia Aérea/diagnóstico , Diseño de Equipo , Equipos y Suministros , Humanos , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso/etiología , Enfermedades del Sistema Nervioso/prevención & control , Complicaciones Posoperatorias/prevención & control , Ultrasonido
6.
Eur J Cardiothorac Surg ; 23(1): 93-6, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12493511

RESUMEN

OBJECTIVE: High intensity transient signals (HITS) observed during extracorporeal circulation and following mechanical valve replacement are suspected of causing cognitive dysfunction (deterioration of episodic and working memory). This study evaluates the role played by valve design (bileaflet versus tilting disc) and other parameters in the incidence of HITS. METHODS: Thirty patients were selected for the study as follows: 18 males, 58-78 years of age; ten St. Jude Medical, ten CarboMedics, ten Medtronic Hall (MH); all size 23, in optimum orientation (Ann Thorac Surg 68 (1999) 1069); all in sinus rhythm; no coronary or carotid artery disease; all in sinus rhythm, international normalized ratio greater than 2.5 and all at least 9 months postoperative. All patients had bilateral HITS measurement in both middle cerebral arteries via transcranial doppler for 30 min. If five HITS or more were observed during the initial 10 min, patients were subjected to 100% oxygen breathing followed by 10 min of normal air breathing. Simultaneously, HITS were measured in the right radial and femoral arteries. RESULTS: Patients with bileaflet valve substitutes revealed HITS rates varying from 32 to 108 counts/h. There was only one HITS observed in the MH valve group during the 5h observation period (0.2 HITS/h). There were no HITS detected in either the radial or the femoral arteries in any patient. After breathing 100% oxygen, HITS significantly decreased or completely disappeared (0-30 HITS/h). When normal air breathing was resumed HITS reappeared or increased. With an intravenous infusion of 100 mg of lysine acetylsalicylate (Aspisol, Bayer Leverkusen, Germany), HITS decreased by 16 to 41%. CONCLUSIONS: We conclude that bileaflet mechanical valve prostheses produce HITS even in their optimum orientation. HITS following bileaflet valve replacement have an unstable nature and might be composed of nitrogen and platelets. Tilting disc valves in their optimum orientation provide almost physiological conditions with HITS measured in the same range as bioprosthesis.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Tromboembolia/diagnóstico por imagen , Anciano , Ecocardiografía Doppler , Electrocardiografía , Circulación Extracorporea , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Trastornos de la Memoria/etiología , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA