Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Eur Radiol Exp ; 8(1): 109, 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39377962

RESUMEN

BACKGROUND: Longitudinal T1 relaxation time is a key imaging biomarker. In addition, T1 values are modulated by the administration of T1 contrast agents used in patients with tumors and metastases. However, in clinical practice, dedicated T1 mapping sequences are often not included in brain MRI protocols. The aim of this study is to address the absence of dedicated T1 mapping sequences in imaging protocol by deriving T1 maps from standard T1-weighted sequences. METHODS: A phantom, composed of 144 solutions of paramagnetic agents at different concentrations, was imaged with a three-dimensional (3D) T1-weighed turbo spin-echo (TSE) sequence designed for brain imaging. The relationship between the T1 values and the signal intensities was established using this phantom acquisition. T1 mapping derived from 3D T1-weighted TSE acquisitions in four healthy volunteers and one patient with brain metastases were established and compared to reference T1 mapping technique. The concentration of Gd-based contrast agents in brain metastases were assessed from the derived T1 maps. RESULTS: Based on the phantom acquisition, the relationship between T1 values and signal intensity (SI) was found equal to T1 = 0.35 × SI-1.11 (R2 = 0.97). TSE-derived T1 values measured in white matter and gray matter in healthy volunteers were equal to 0.997 ± 0.096 s and 1.358 ± 0.056 s (mean ± standard deviation), respectively. Mean Gd3+ concentration value in brain metastases was 94.7 ± 30.0 µM. CONCLUSION: The in vivo results support the relevance of the phantom-based approach: brain T1 maps can be derived from T1-weighted acquisitions. RELEVANCE STATEMENT: High-resolution brain T1 maps can be generated, and contrast agent concentration can be quantified and imaged in brain metastases using routine 3D T1-weighted TSE acquisitions. KEY POINTS: Quantitative T1 mapping adds significant value to MRI diagnostics. T1 measurement sequences are rarely included in routine protocols. T1 mapping and concentration of contrast agents can be derived from routine standard scans. The diagnostic value of MRI can be improved without additional scan time.


Asunto(s)
Neoplasias Encefálicas , Medios de Contraste , Imagen por Resonancia Magnética , Fantasmas de Imagen , Prueba de Estudio Conceptual , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/secundario , Masculino , Femenino , Adulto , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Encéfalo/diagnóstico por imagen
2.
J Magn Reson Imaging ; 58(1): 313-323, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36315197

RESUMEN

BACKGROUND: The measurement of the concentration of theranostic agents in vivo is essential for the assessment of their therapeutic efficacy and their safety regarding healthy tissue. To this end, there is a need for quantitative T1 measurements that can be obtained as part of a standard clinical imaging protocol applied to tumor patients. PURPOSE: To generate T1 maps from MR images obtained with the magnetization-prepared rapid gradient echo (MPRAGE) sequence. To evaluate the feasibility of the proposed approach on phantoms, animal and patients with brain metastases. STUDY TYPE: Pilot. PHANTOM/ANIMAL MODEL/POPULATION: Solutions containing contrast agents (chelated Gd3+ and iron nanoparticles), male rat of Wistar strain, three patients with brain metastases. FIELD STRENGTH/SEQUENCE: A 3-T and 7-T, saturation recovery (SR), and MPRAGE sequences. ASSESSMENT: The MPRAGE T1 measurement was compared to the reference SR method on phantoms and rat brain at 7-T. The robustness of the in vivo method was evaluated by studying the impact of misestimates of tissue proton density. Concentrations of Gd-based theranostic agents were measured at 3-T in gray matter and metastases in patients recruited in NanoRad clinical trial. STATISTICAL TESTS: A linear model was used to characterize the relation between T1 measurements from the MPRAGE and the SR acquisitions obtained in vitro at 7-T. RESULTS: The slope of the linear model was 0.966 (R2  = 0.9934). MPRAGE-based T1 values measured in the rat brain were 1723 msec in the thalamus. MPRAGE-based T1 values measured in patients in white matter and gray matter amounted to 747 msec and 1690 msec. Mean concentration values of Gd3+ in metastases were 61.47 µmol. DATA CONCLUSION: The T1 values obtained in vitro and in vivo support the validity of the proposed approach. The concentrations of Gd-based theranostic agents may be assessed in patients with metastases within a standard clinical imaging protocol using the MPRAGE sequence. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Neoplasias Encefálicas , Encéfalo , Masculino , Animales , Ratas , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Medicina de Precisión , Ratas Wistar , Imagen por Resonancia Magnética/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA